A Voltammetry Potentiostat Design for Large Dynamic Range Current Measurement
In this paper, we design a voltammetry potentiostat for the signal processing of electrochemical biosensors. By means of a current range detector and multi-ratio current mirrors, the measured currents of biosensors can be scaled to a proper magnitude of currents. So, the proposed potentiostat can be...
Saved in:
| Published in | 2011 International Conference on Intelligent Computation and Bio-Medical Instrumentation pp. 260 - 263 |
|---|---|
| Main Authors | , , |
| Format | Conference Proceeding |
| Language | English |
| Published |
IEEE
01.12.2011
|
| Subjects | |
| Online Access | Get full text |
| ISBN | 9781457711527 1457711524 |
| DOI | 10.1109/ICBMI.2011.44 |
Cover
| Abstract | In this paper, we design a voltammetry potentiostat for the signal processing of electrochemical biosensors. By means of a current range detector and multi-ratio current mirrors, the measured currents of biosensors can be scaled to a proper magnitude of currents. So, the proposed potentiostat can be applied in the biosensors with large dynamic range current variation. The measured biosensor current is converted to a frequency-modulated pulse waveform, whose frequency is proportional to the magnitude of the biosensor current. The simulation results show that the detectable range of the biosensor's current is from 10 nA to 1 mA. |
|---|---|
| AbstractList | In this paper, we design a voltammetry potentiostat for the signal processing of electrochemical biosensors. By means of a current range detector and multi-ratio current mirrors, the measured currents of biosensors can be scaled to a proper magnitude of currents. So, the proposed potentiostat can be applied in the biosensors with large dynamic range current variation. The measured biosensor current is converted to a frequency-modulated pulse waveform, whose frequency is proportional to the magnitude of the biosensor current. The simulation results show that the detectable range of the biosensor's current is from 10 nA to 1 mA. |
| Author | Chun-Yueh Huang Bin-Da Liu Yi-Fan Liang |
| Author_xml | – sequence: 1 surname: Yi-Fan Liang fullname: Yi-Fan Liang email: jakelian@gmail.com organization: Dept. of Electr. Eng., Nat. Univ. of Tainan, Tainan, Taiwan – sequence: 2 surname: Chun-Yueh Huang fullname: Chun-Yueh Huang email: cyhun@ieee.org organization: Dept. of Electr. Eng., Nat. Univ. of Tainan, Tainan, Taiwan – sequence: 3 surname: Bin-Da Liu fullname: Bin-Da Liu email: bdliu@mail.ncku.edu.tw organization: Dept. of Electr. Eng., Nat. Cheng Kung Univ., Tainan, Taiwan |
| BookMark | eNpVjEtLw0AUhUdUUGuWrtzMH2icm3ndLGvqI9CiSHFbbpObEmkSmUwX_fcGdOPZfOeDw7kRF_3QsxB3oFIAlT-UxeO6TDMFkBpzJpLcIxjrPYAFdf7PM38lknH8UlOcy73y12K9kJ_DIVLXcQwn-T5E7mM7jJGiXPLY7nvZDEGuKOxZLk89dW0lP6ifrDiGMI3lmmk8Bu6mfisuGzqMnPxxJjbPT5vidb56eymLxWre5irOrSHtNFS6zp1FYzgnRoe7uq7QNAbrzGkNisntkFyWYeMsYYWqwRorxXom7n9vW2befoe2o3DaOtDgLeofqGtQWg |
| ContentType | Conference Proceeding |
| DBID | 6IE 6IL CBEJK RIE RIL |
| DOI | 10.1109/ICBMI.2011.44 |
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Xplore DIgital Library IEEE Proceedings Order Plans (POP All) 1998-Present |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
| DeliveryMethod | fulltext_linktorsrc |
| EISBN | 9781457711510 0769546234 9780769546230 1457711516 |
| EndPage | 263 |
| ExternalDocumentID | 6131758 |
| Genre | orig-research |
| GroupedDBID | 6IE 6IF 6IK 6IL 6IN AAJGR AAWTH ADFMO ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK IEGSK IERZE OCL RIE RIL |
| ID | FETCH-LOGICAL-i90t-54a3631c3d965844e9ae868bddc84f48d263310ea6b8a6228f65a8c80f8d8c0e3 |
| IEDL.DBID | RIE |
| ISBN | 9781457711527 1457711524 |
| IngestDate | Wed Aug 27 04:12:36 EDT 2025 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-i90t-54a3631c3d965844e9ae868bddc84f48d263310ea6b8a6228f65a8c80f8d8c0e3 |
| PageCount | 4 |
| ParticipantIDs | ieee_primary_6131758 |
| PublicationCentury | 2000 |
| PublicationDate | 2011-Dec. |
| PublicationDateYYYYMMDD | 2011-12-01 |
| PublicationDate_xml | – month: 12 year: 2011 text: 2011-Dec. |
| PublicationDecade | 2010 |
| PublicationTitle | 2011 International Conference on Intelligent Computation and Bio-Medical Instrumentation |
| PublicationTitleAbbrev | icbmi |
| PublicationYear | 2011 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| SSID | ssj0000669707 ssib026766923 |
| Score | 1.5076386 |
| Snippet | In this paper, we design a voltammetry potentiostat for the signal processing of electrochemical biosensors. By means of a current range detector and... |
| SourceID | ieee |
| SourceType | Publisher |
| StartPage | 260 |
| SubjectTerms | Biosensors Current measurement current mirror Detectors Electric potential electrochemical sensor Electrodes Frequency conversion Mirrors potentiostat |
| Title | A Voltammetry Potentiostat Design for Large Dynamic Range Current Measurement |
| URI | https://ieeexplore.ieee.org/document/6131758 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwGLTaTkyAWsRbHhhJmyb2Z2eElqpFBFWooG5V_IiEQA2qnAF-PbaTtAIxsCWZ4od8ly939yF0JYcqsUgnAqUVDYjMSZBYXuIK-YTGOdgt5LzD6SNMn8n9ki5b6HrrhdFae_GZ7rtL_y9fFbJ0pbKBhR6LdryN2oxD5dVq9k4EDKD5FKhOYUhYyLyXizJmiU9Emoin-p7tMjcHs9FtOqsSPQn50WnFA81kH6XNK1b6krd-aURffv1Kb_zvGA5Qb2fpw_MtWB2ill53UXqDX4p344rXZvOJ54Xx4kdnMsJjL-3AltPiB6cWx-Oqdz1-cnYEXOc64XRXY-yhxeRuMZoGdX-F4DUJTUBJFkM8lLFyATCE6CTTHLhQSnKSE64iiC350xkIntlF4znQjEse5lxxGer4CHXWxVofIyxopAjQSNjBESEibokbj4XMINShHqoT1HUzsfqoEjRW9SSc_v34DO35yq0XjZyjjtmU-sJCvxGXfs2_Abg_qFU |
| linkProvider | IEEE |
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NT8JAFHxBPOhJDRi_3YNHC6V9u90eFTSglBCDhhvpfjQxGjCkHPTXu7ttIRoP3tqeuh_Zmb7OzAO4kh0VG6QTntKKeigz9GLDS2whH2mYMbOFrHc4GbH-Mz5M6bQG12svjNbaic90y166f_lqIVe2VNY20GPQjm_BNkVEWri1qt0TsIix6mOgOIdZHPmRc3PRKDLUJ8Aq5Km8jzapm-1B9zYZFJmeiD96rTioud-DpHrJQmHy1lrloiW_fuU3_ncU-9DcmPrIeA1XB1DT8wYkN-Rl8Z7b8nW-_CTjRe7kj9ZmRHpO3EEMqyVDqxcnvaJ7PXmyhgRSJjuRZFNlbMLk_m7S7XtlhwXvNfZzj2IasrAjQ2UjYBB1nGrOuFBKcsyQq4CFhv7plAmemmXjGaMpl9zPuOLS1-Eh1OeLuT4CImigkNFAmMGhEAE31I2HQqbM177uqGNo2JmYfRQZGrNyEk7-fnwJO_1JMpwNB6PHU9h1dVwnITmDer5c6XNDBHJx4db_G783q6I |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2011+International+Conference+on+Intelligent+Computation+and+Bio-Medical+Instrumentation&rft.atitle=A+Voltammetry+Potentiostat+Design+for+Large+Dynamic+Range+Current+Measurement&rft.au=Yi-Fan+Liang&rft.au=Chun-Yueh+Huang&rft.au=Bin-Da+Liu&rft.date=2011-12-01&rft.pub=IEEE&rft.isbn=9781457711527&rft.spage=260&rft.epage=263&rft_id=info:doi/10.1109%2FICBMI.2011.44&rft.externalDocID=6131758 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781457711527/lc.gif&client=summon&freeimage=true |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781457711527/mc.gif&client=summon&freeimage=true |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9781457711527/sc.gif&client=summon&freeimage=true |