Output voltage and level control algorithm during submodule fault of modular multilevel converter for HVDC transmission system
This paper presents a new algorithm which automatically tracks submodule fault and on the basis of submodule fault reduces the number of level and output voltage of modular multilevel converter (MMC) in high-voltage DC transmission system. Carrier and Signal (reference) Magnitude Control Sinusoidal...
Saved in:
| Published in | 2016 IEEE International WIE Conference on Electrical and Computer Engineering (WIECON-ECE) pp. 126 - 129 |
|---|---|
| Main Authors | , , , |
| Format | Conference Proceeding |
| Language | English |
| Published |
IEEE
01.12.2016
|
| Subjects | |
| Online Access | Get full text |
| DOI | 10.1109/WIECON-ECE.2016.8009101 |
Cover
| Abstract | This paper presents a new algorithm which automatically tracks submodule fault and on the basis of submodule fault reduces the number of level and output voltage of modular multilevel converter (MMC) in high-voltage DC transmission system. Carrier and Signal (reference) Magnitude Control Sinusoidal Pulse Width Modulation (CSMC-SPWM) technique is used to generate gate pulses of the MMC converter. This CSMC-SPWM technique is used for running the converter under normal condition and also generates pulses for the faulty Sub-Modules (SM) to bypass the supply voltage to un-faulty SMs and decrease the level of operation as well as converter output voltage so the converter remains in operating conditions during the large number of submodule fault. The simulation results show that MMC operates well to any level of operation and faulty SMs are completely removed from any phase of the inverter with lower output voltage. |
|---|---|
| AbstractList | This paper presents a new algorithm which automatically tracks submodule fault and on the basis of submodule fault reduces the number of level and output voltage of modular multilevel converter (MMC) in high-voltage DC transmission system. Carrier and Signal (reference) Magnitude Control Sinusoidal Pulse Width Modulation (CSMC-SPWM) technique is used to generate gate pulses of the MMC converter. This CSMC-SPWM technique is used for running the converter under normal condition and also generates pulses for the faulty Sub-Modules (SM) to bypass the supply voltage to un-faulty SMs and decrease the level of operation as well as converter output voltage so the converter remains in operating conditions during the large number of submodule fault. The simulation results show that MMC operates well to any level of operation and faulty SMs are completely removed from any phase of the inverter with lower output voltage. |
| Author | Munjer, M. A. Khan, M. A. G. Alim, M. A. Kabir, Sumaiya |
| Author_xml | – sequence: 1 givenname: M. A. surname: Alim fullname: Alim, M. A. organization: Dept. of Electr. & Electron. Eng., Bangladesh Army Univ. of Eng. & Technol., Rajshahi, Bangladesh – sequence: 2 givenname: M. A. G. surname: Khan fullname: Khan, M. A. G. organization: Dept. of Electr. & Electron. Eng., Bangladesh Army Univ. of Eng. & Technol., Rajshahi, Bangladesh – sequence: 3 givenname: M. A. surname: Munjer fullname: Munjer, M. A. organization: Dept. of Electr. & Electron. Eng., Bangladesh Army Univ. of Eng. & Technol., Rajshahi, Bangladesh – sequence: 4 givenname: Sumaiya surname: Kabir fullname: Kabir, Sumaiya organization: Dept. of Electr. & Electron. Eng., Bangladesh Army Univ. of Eng. & Technol., Rajshahi, Bangladesh |
| BookMark | eNo9kLFOwzAURY0EA5R-AQPvB1LsOLHjEYVAK1V0qWCs7OS5WHLiynEqdeHbQbRiOjrDucO9I9dDGJCQR0YXjFH19Llq6s171tTNIqdMLCpKFaPsisyVrFhJFeWyKPNb8r2Z0mFKcAw-6T2CHjrweEQPbRhSDB6034fo0lcP3RTdsIdxMn3oJo9g9eQTBAt_riP0v-7-8yPGhBFsiLD8eKkhRT2MvRtHFwYYT2PC_p7cWO1HnF84I9vXZlsvs_XmbVU_rzOnaMryknayRGMralAK3VIhuMhR0VxbUeWFNBalbAtJc8W4rUyBXBhupDEobMtn5OE86xBxd4iu1_G0u5zCfwC45WCA |
| ContentType | Conference Proceeding |
| DBID | 6IE 6IL CBEJK RIE RIL |
| DOI | 10.1109/WIECON-ECE.2016.8009101 |
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
| DeliveryMethod | fulltext_linktorsrc |
| EISBN | 9781509037452 9781509037438 1509037454 1509037438 |
| EndPage | 129 |
| ExternalDocumentID | 8009101 |
| Genre | orig-research |
| GroupedDBID | 6IE 6IL CBEJK RIE RIL |
| ID | FETCH-LOGICAL-i90t-250d75ebf80be76ac066362e902af68247bfe77c4702913f8b4e36b3b7bbe6fc3 |
| IEDL.DBID | RIE |
| IngestDate | Thu Jun 29 18:37:55 EDT 2023 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-i90t-250d75ebf80be76ac066362e902af68247bfe77c4702913f8b4e36b3b7bbe6fc3 |
| PageCount | 4 |
| ParticipantIDs | ieee_primary_8009101 |
| PublicationCentury | 2000 |
| PublicationDate | 2016-Dec. |
| PublicationDateYYYYMMDD | 2016-12-01 |
| PublicationDate_xml | – month: 12 year: 2016 text: 2016-Dec. |
| PublicationDecade | 2010 |
| PublicationTitle | 2016 IEEE International WIE Conference on Electrical and Computer Engineering (WIECON-ECE) |
| PublicationTitleAbbrev | WIECON-ECE |
| PublicationYear | 2016 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| Score | 1.6394746 |
| Snippet | This paper presents a new algorithm which automatically tracks submodule fault and on the basis of submodule fault reduces the number of level and output... |
| SourceID | ieee |
| SourceType | Publisher |
| StartPage | 126 |
| SubjectTerms | Circuit faults Conferences csc csmc hvdc HVDC transmission igbt Inverters mmc Modular multilevel converters spwm Switches Voltage control vsc |
| Title | Output voltage and level control algorithm during submodule fault of modular multilevel converter for HVDC transmission system |
| URI | https://ieeexplore.ieee.org/document/8009101 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV09T8MwELVKJyZALeJbNzCSNB-uncylVUEqMBToVtnJGSpCUgVnYeC3YyehCMTAFke2Evmse2f7vTtCziMqQ6FC6QQiTh3KJHXiRFCHDzEWia-GqbRq5NkNm97T68Vw0SEXGy0MItbkM3TtY32XnxZJZY_KBia4Mehm9jpbPGKNVqulbPlePHi8srX_nPFobBlbzG17_yibUqPGZIfMvr7XkEVe3EpLN3n_lYrxvz-0S_rf-jy42yDPHulg3iMft5VeVxqMv9HGSYDIU8gsJQhaOjqI7KkoV_r5FRpxIrwZMCzSKkNQoso0FArqtiihJhpuhtuizViCCXBh-nA5Am0RzqwQe9QGTTLoPplPxvPR1GmrKzir2NOOCX1SYxCpIk8iZyKxsQcLMPYCoVgUUC4Vcp5Q7gWxH6pIUgyZDCWXEplKwn3SzYscDwgo4xd8KYQfq4hiisbqkUSzr2OcWmnwIenZqVuum_wZy3bWjv5-fUy2rfkaysgJ6eqywlMD_Fqe1Rb_BBj1tBk |
| linkProvider | IEEE |
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV09T8MwELVQGWAC1CK-uYGRpPlwnGQurVpoC0OBbpWdnKGiJFVxFgZ-O3YSikAMbEmUKJEvuvdsv3dHyEVEhc-lLyyPx6lFmaBWnHBqhQHGPHFlkArjRh6NWf-eXk-D6Qa5XHthELEUn6FtDsu9_DRPCrNU1tbkRqObnutsBpTSoHJr1aIt14nbjwPT_c_qdrpGs8Xs-v4fjVNK3OjtkNHXGyu5yItdKGEn77-KMf73k3ZJ69uhB3dr7NkjG5g1ycdtoZaFAp1xlE4TwLMUFkYUBLUgHfjiKV_N1fMrVPZEeNNwmKfFAkHyYqEgl1Ce8xWUUsP146ZtM65AU1zoP1x1QBmM0_-IWWyDqhx0i0x63Umnb9X9Fax57ChLk59Uh0TIyBEYMp4Y9sE8jB2PSxZ5NBQSwzChoePFri8jQdFnwhehEMhk4u-TRpZneEBA6szgCs7dWEYUU9RxjwTqmR0LqTEHH5KmGbrZsqqgMatH7ejvy-dkqz8ZDWfDwfjmmGybUFYCkhPSUKsCTzUNUOKsjP4nrlG3Zg |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2016+IEEE+International+WIE+Conference+on+Electrical+and+Computer+Engineering+%28WIECON-ECE%29&rft.atitle=Output+voltage+and+level+control+algorithm+during+submodule+fault+of+modular+multilevel+converter+for+HVDC+transmission+system&rft.au=Alim%2C+M.+A.&rft.au=Khan%2C+M.+A.+G.&rft.au=Munjer%2C+M.+A.&rft.au=Kabir%2C+Sumaiya&rft.date=2016-12-01&rft.pub=IEEE&rft.spage=126&rft.epage=129&rft_id=info:doi/10.1109%2FWIECON-ECE.2016.8009101&rft.externalDocID=8009101 |