Output voltage and level control algorithm during submodule fault of modular multilevel converter for HVDC transmission system

This paper presents a new algorithm which automatically tracks submodule fault and on the basis of submodule fault reduces the number of level and output voltage of modular multilevel converter (MMC) in high-voltage DC transmission system. Carrier and Signal (reference) Magnitude Control Sinusoidal...

Full description

Saved in:
Bibliographic Details
Published in2016 IEEE International WIE Conference on Electrical and Computer Engineering (WIECON-ECE) pp. 126 - 129
Main Authors Alim, M. A., Khan, M. A. G., Munjer, M. A., Kabir, Sumaiya
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.12.2016
Subjects
Online AccessGet full text
DOI10.1109/WIECON-ECE.2016.8009101

Cover

Abstract This paper presents a new algorithm which automatically tracks submodule fault and on the basis of submodule fault reduces the number of level and output voltage of modular multilevel converter (MMC) in high-voltage DC transmission system. Carrier and Signal (reference) Magnitude Control Sinusoidal Pulse Width Modulation (CSMC-SPWM) technique is used to generate gate pulses of the MMC converter. This CSMC-SPWM technique is used for running the converter under normal condition and also generates pulses for the faulty Sub-Modules (SM) to bypass the supply voltage to un-faulty SMs and decrease the level of operation as well as converter output voltage so the converter remains in operating conditions during the large number of submodule fault. The simulation results show that MMC operates well to any level of operation and faulty SMs are completely removed from any phase of the inverter with lower output voltage.
AbstractList This paper presents a new algorithm which automatically tracks submodule fault and on the basis of submodule fault reduces the number of level and output voltage of modular multilevel converter (MMC) in high-voltage DC transmission system. Carrier and Signal (reference) Magnitude Control Sinusoidal Pulse Width Modulation (CSMC-SPWM) technique is used to generate gate pulses of the MMC converter. This CSMC-SPWM technique is used for running the converter under normal condition and also generates pulses for the faulty Sub-Modules (SM) to bypass the supply voltage to un-faulty SMs and decrease the level of operation as well as converter output voltage so the converter remains in operating conditions during the large number of submodule fault. The simulation results show that MMC operates well to any level of operation and faulty SMs are completely removed from any phase of the inverter with lower output voltage.
Author Munjer, M. A.
Khan, M. A. G.
Alim, M. A.
Kabir, Sumaiya
Author_xml – sequence: 1
  givenname: M. A.
  surname: Alim
  fullname: Alim, M. A.
  organization: Dept. of Electr. & Electron. Eng., Bangladesh Army Univ. of Eng. & Technol., Rajshahi, Bangladesh
– sequence: 2
  givenname: M. A. G.
  surname: Khan
  fullname: Khan, M. A. G.
  organization: Dept. of Electr. & Electron. Eng., Bangladesh Army Univ. of Eng. & Technol., Rajshahi, Bangladesh
– sequence: 3
  givenname: M. A.
  surname: Munjer
  fullname: Munjer, M. A.
  organization: Dept. of Electr. & Electron. Eng., Bangladesh Army Univ. of Eng. & Technol., Rajshahi, Bangladesh
– sequence: 4
  givenname: Sumaiya
  surname: Kabir
  fullname: Kabir, Sumaiya
  organization: Dept. of Electr. & Electron. Eng., Bangladesh Army Univ. of Eng. & Technol., Rajshahi, Bangladesh
BookMark eNo9kLFOwzAURY0EA5R-AQPvB1LsOLHjEYVAK1V0qWCs7OS5WHLiynEqdeHbQbRiOjrDucO9I9dDGJCQR0YXjFH19Llq6s171tTNIqdMLCpKFaPsisyVrFhJFeWyKPNb8r2Z0mFKcAw-6T2CHjrweEQPbRhSDB6034fo0lcP3RTdsIdxMn3oJo9g9eQTBAt_riP0v-7-8yPGhBFsiLD8eKkhRT2MvRtHFwYYT2PC_p7cWO1HnF84I9vXZlsvs_XmbVU_rzOnaMryknayRGMralAK3VIhuMhR0VxbUeWFNBalbAtJc8W4rUyBXBhupDEobMtn5OE86xBxd4iu1_G0u5zCfwC45WCA
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/WIECON-ECE.2016.8009101
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 9781509037452
9781509037438
1509037454
1509037438
EndPage 129
ExternalDocumentID 8009101
Genre orig-research
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i90t-250d75ebf80be76ac066362e902af68247bfe77c4702913f8b4e36b3b7bbe6fc3
IEDL.DBID RIE
IngestDate Thu Jun 29 18:37:55 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i90t-250d75ebf80be76ac066362e902af68247bfe77c4702913f8b4e36b3b7bbe6fc3
PageCount 4
ParticipantIDs ieee_primary_8009101
PublicationCentury 2000
PublicationDate 2016-Dec.
PublicationDateYYYYMMDD 2016-12-01
PublicationDate_xml – month: 12
  year: 2016
  text: 2016-Dec.
PublicationDecade 2010
PublicationTitle 2016 IEEE International WIE Conference on Electrical and Computer Engineering (WIECON-ECE)
PublicationTitleAbbrev WIECON-ECE
PublicationYear 2016
Publisher IEEE
Publisher_xml – name: IEEE
Score 1.6394746
Snippet This paper presents a new algorithm which automatically tracks submodule fault and on the basis of submodule fault reduces the number of level and output...
SourceID ieee
SourceType Publisher
StartPage 126
SubjectTerms Circuit faults
Conferences
csc
csmc
hvdc
HVDC transmission
igbt
Inverters
mmc
Modular multilevel converters
spwm
Switches
Voltage control
vsc
Title Output voltage and level control algorithm during submodule fault of modular multilevel converter for HVDC transmission system
URI https://ieeexplore.ieee.org/document/8009101
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV09T8MwELVKJyZALeJbNzCSNB-uncylVUEqMBToVtnJGSpCUgVnYeC3YyehCMTAFke2Evmse2f7vTtCziMqQ6FC6QQiTh3KJHXiRFCHDzEWia-GqbRq5NkNm97T68Vw0SEXGy0MItbkM3TtY32XnxZJZY_KBia4Mehm9jpbPGKNVqulbPlePHi8srX_nPFobBlbzG17_yibUqPGZIfMvr7XkEVe3EpLN3n_lYrxvz-0S_rf-jy42yDPHulg3iMft5VeVxqMv9HGSYDIU8gsJQhaOjqI7KkoV_r5FRpxIrwZMCzSKkNQoso0FArqtiihJhpuhtuizViCCXBh-nA5Am0RzqwQe9QGTTLoPplPxvPR1GmrKzir2NOOCX1SYxCpIk8iZyKxsQcLMPYCoVgUUC4Vcp5Q7gWxH6pIUgyZDCWXEplKwn3SzYscDwgo4xd8KYQfq4hiisbqkUSzr2OcWmnwIenZqVuum_wZy3bWjv5-fUy2rfkaysgJ6eqywlMD_Fqe1Rb_BBj1tBk
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV09T8MwELVQGWAC1CK-uYGRpPlwnGQurVpoC0OBbpWdnKGiJFVxFgZ-O3YSikAMbEmUKJEvuvdsv3dHyEVEhc-lLyyPx6lFmaBWnHBqhQHGPHFlkArjRh6NWf-eXk-D6Qa5XHthELEUn6FtDsu9_DRPCrNU1tbkRqObnutsBpTSoHJr1aIt14nbjwPT_c_qdrpGs8Xs-v4fjVNK3OjtkNHXGyu5yItdKGEn77-KMf73k3ZJ69uhB3dr7NkjG5g1ycdtoZaFAp1xlE4TwLMUFkYUBLUgHfjiKV_N1fMrVPZEeNNwmKfFAkHyYqEgl1Ce8xWUUsP146ZtM65AU1zoP1x1QBmM0_-IWWyDqhx0i0x63Umnb9X9Fax57ChLk59Uh0TIyBEYMp4Y9sE8jB2PSxZ5NBQSwzChoePFri8jQdFnwhehEMhk4u-TRpZneEBA6szgCs7dWEYUU9RxjwTqmR0LqTEHH5KmGbrZsqqgMatH7ejvy-dkqz8ZDWfDwfjmmGybUFYCkhPSUKsCTzUNUOKsjP4nrlG3Zg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2016+IEEE+International+WIE+Conference+on+Electrical+and+Computer+Engineering+%28WIECON-ECE%29&rft.atitle=Output+voltage+and+level+control+algorithm+during+submodule+fault+of+modular+multilevel+converter+for+HVDC+transmission+system&rft.au=Alim%2C+M.+A.&rft.au=Khan%2C+M.+A.+G.&rft.au=Munjer%2C+M.+A.&rft.au=Kabir%2C+Sumaiya&rft.date=2016-12-01&rft.pub=IEEE&rft.spage=126&rft.epage=129&rft_id=info:doi/10.1109%2FWIECON-ECE.2016.8009101&rft.externalDocID=8009101