Development of failure detection system based on vibration signal for smart artificial heart: In vitro study

To realize safe and effective medical treatment for patients with implantable artificial hearts, we have developed a smart artificial heart (SAH). The SAH can grasp the mechanical condition of the artificial heart and the physiological condition of the patient. The purpose of this study is to develo...

Full description

Saved in:
Bibliographic Details
Published in2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society Vol. 2008; pp. 697 - 702
Main Authors Tsujimura, Shinichi, Kuwabara, Takashi, Koguchi, Harutoshi, Yamane, Takashi, Tsutsui, Tatsuo, Sankai, Yoshiyuki
Format Conference Proceeding Journal Article
LanguageEnglish
Published United States IEEE 01.01.2008
Subjects
Online AccessGet full text
ISBN9781424418145
1424418143
ISSN1094-687X
1557-170X
DOI10.1109/IEMBS.2008.4649248

Cover

Abstract To realize safe and effective medical treatment for patients with implantable artificial hearts, we have developed a smart artificial heart (SAH). The SAH can grasp the mechanical condition of the artificial heart and the physiological condition of the patient. The purpose of this study is to develop a failure detection system based on the vibration signal from artificial heart in order to enhance the ability of failure detection for the SAH. We suppose this vibration signal reflects not only the mechanical condition of the artificial heart but also a part of the physiological condition of the patient. The developed failure detection system is composed of a vibration sensor unit and a failure detection algorithm. The algorithm has a standard frequency pattern, which is made from the vibration signal of good condition of both the artificial heart and patient. Observing the difference from the standard frequency pattern, the algorithm detects failure conditions. Therefore, this algorithm does not need prior knowledge of vibration characteristics corresponding to failures. After confirming that the vibration signal are affected by pump speed and pulsation in two kinds of mock circulatory loops, we performed thrombogenesis detection by using the failure detection system in mock circulatory loop with sheep blood. As a result, this system indicated a possibility of detecting the initial sign of thrombogenesis earlier than current signal. In conclusion, we think that this failure detection system can cooperate with other sensor systems of the SAH and enhance the ability of failure detection for the SAH.
AbstractList To realize safe and effective medical treatment for patients with implantable artificial hearts, we have developed a smart artificial heart (SAH). The SAH can grasp the mechanical condition of the artificial heart and the physiological condition of the patient. The purpose of this study is to develop a failure detection system based on the vibration signal from artificial heart in order to enhance the ability of failure detection for the SAH. We suppose this vibration signal reflects not only the mechanical condition of the artificial heart but also a part of the physiological condition of the patient. The developed failure detection system is composed of a vibration sensor unit and a failure detection algorithm. The algorithm has a standard frequency pattern, which is made from the vibration signal of good condition of both the artificial heart and patient. Observing the difference from the standard frequency pattern, the algorithm detects failure conditions. Therefore, this algorithm does not need prior knowledge of vibration characteristics corresponding to failures. After confirming that the vibration signal are affected by pump speed and pulsation in two kinds of mock circulatory loops, we performed thrombogenesis detection by using the failure detection system in mock circulatory loop with sheep blood. As a result, this system indicated a possibility of detecting the initial sign of thrombogenesis earlier than current signal. In conclusion, we think that this failure detection system can cooperate with other sensor systems of the SAH and enhance the ability of failure detection for the SAH.
Author Takashi Yamane
Takashi Kuwabara
Harutoshi Koguchi
Shinichi Tsujimura
Tatsuo Tsutsui
Yoshiyuki Sankai
Author_xml – sequence: 1
  givenname: Shinichi
  surname: Tsujimura
  fullname: Tsujimura, Shinichi
  email: tujimura@golem.kz.tsukuba.ac.jp
  organization: Systems and Information Engineering, University of Tsukuba, 1-1-1 Tennoudai, Ibaraki, 305-8573, Japan. tujimura@golem.kz.tsukuba.ac.jp
– sequence: 2
  givenname: Takashi
  surname: Kuwabara
  fullname: Kuwabara, Takashi
– sequence: 3
  givenname: Harutoshi
  surname: Koguchi
  fullname: Koguchi, Harutoshi
– sequence: 4
  givenname: Takashi
  surname: Yamane
  fullname: Yamane, Takashi
– sequence: 5
  givenname: Tatsuo
  surname: Tsutsui
  fullname: Tsutsui, Tatsuo
– sequence: 6
  givenname: Yoshiyuki
  surname: Sankai
  fullname: Sankai, Yoshiyuki
BackLink https://www.ncbi.nlm.nih.gov/pubmed/19162751$$D View this record in MEDLINE/PubMed
BookMark eNpVUNtKAzEQjVixtfYHFCQ_sDX3zfpma9VCxQcVfCvZZqKRvZRNWujfG2kVHBiGM3POMGfOUK9pG0DogpIxpaS4ns-eJi9jRogeCyUKJvQRGhW5poIJQTWV7PgfFrKHBkkoMqXz9z4ahfBFUgjJlSanqE8Lqlgu6QBVd7CFql3X0ETcOuyMrzYdYAsRVtG3DQ67EKHGpQlgccJbX3ZmP_EfjamwazscatNFnNI7v_Kp-QkJ3OD5Dz92LQ5xY3fn6MSZKsDoUIfo7X72On3MFs8P8-ntIvOc6ZjxZFRSp52SyY9VmhkpLVW5UdLoUq-I4WXBnVSMANcuZyovrRIsqYwtBB-iq_3e9aaswS7XnU_37Za_thPhck_wAPA3PvyWfwPnm2o8
ContentType Conference Proceeding
Journal Article
DBID 6IE
6IH
CBEJK
RIE
RIO
CGR
CUY
CVF
ECM
EIF
NPM
DOI 10.1109/IEMBS.2008.4649248
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan (POP) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP) 1998-present
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
DatabaseTitle MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
DatabaseTitleList
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 3
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 9781424418152
1424418151
EndPage 702
ExternalDocumentID 19162751
4649248
Genre orig-research
Evaluation Studies
Journal Article
GroupedDBID 6IE
6IF
6IH
AAJGR
ACGFS
AFFNX
ALMA_UNASSIGNED_HOLDINGS
CBEJK
M43
RIE
RIO
RNS
29F
29G
6IK
6IM
CGR
CUY
CVF
ECM
EIF
IPLJI
NPM
ID FETCH-LOGICAL-i328t-300851f8f65244d682a55d167a65a8b8c0a3b93f5620e38f7267bd642851ad943
IEDL.DBID RIE
ISBN 9781424418145
1424418143
ISSN 1094-687X
1557-170X
IngestDate Thu Jan 02 22:05:46 EST 2025
Wed Sep 03 07:10:32 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i328t-300851f8f65244d682a55d167a65a8b8c0a3b93f5620e38f7267bd642851ad943
PMID 19162751
PageCount 6
ParticipantIDs pubmed_primary_19162751
ieee_primary_4649248
PublicationCentury 2000
PublicationDate 2008-01-01
PublicationDateYYYYMMDD 2008-01-01
PublicationDate_xml – month: 01
  year: 2008
  text: 2008-01-01
  day: 01
PublicationDecade 2000
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle 2008 30th Annual International Conference of the IEEE Engineering in Medicine and Biology Society
PublicationTitleAbbrev IEMBS
PublicationTitleAlternate Conf Proc IEEE Eng Med Biol Soc
PublicationYear 2008
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0000453680
ssj0020051
ssj0061641
Score 1.4656482
Snippet To realize safe and effective medical treatment for patients with implantable artificial hearts, we have developed a smart artificial heart (SAH). The SAH can...
SourceID pubmed
ieee
SourceType Index Database
Publisher
StartPage 697
SubjectTerms Algorithms
Artificial heart
Blood
Diagnosis, Computer-Assisted - instrumentation
Diagnosis, Computer-Assisted - methods
Equipment Failure Analysis - methods
Heart Auscultation - methods
Heart, Artificial
Humans
Impellers
Indexes
Physiology
Pumps
Reproducibility of Results
Reservoirs
Resonant frequency
Sensitivity and Specificity
Therapy, Computer-Assisted - instrumentation
Therapy, Computer-Assisted - methods
Vibration
Vibrations
Title Development of failure detection system based on vibration signal for smart artificial heart: In vitro study
URI https://ieeexplore.ieee.org/document/4649248
https://www.ncbi.nlm.nih.gov/pubmed/19162751
Volume 2008
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwELbaTrDwaIHykgdG0kf8iMMIatUiFSFBpW6VE9uoAhJUUgZ-PT47KVXFwBbLiSKfP-nu7O--Q-jKupW0J7UKpDYioKmGboBJGtjIPqTWA-k4hnrnyQMfTen9jM1q6HpdC6O1duQz3YFHd5ev8nQFR2VdyqlNF0Qd1SPBfa3W-jzFhiaEAxbLZAvQ5m46YxpwEc2qoi7r0SiptJ7KMauqaXpxdzyY3D55jmX5O6cr2gc1337ZgmUrBHWuaLiHJtUiPAPltbMqkk76vaXv-N9V7qPWb9Effly7swNU09kh2t3QK2yitw2KEc4NNnIBrHasdOEYXRn2wtAYfKPCdvwF2bifWbxYzGIbI-PPd4tXDJj18hUYumoXN3gM7xfLHDvN2xaaDgfPd6OgbNcQLEgoioC48M0Iw5m1q-IilIypPo8kZ1IkgAmSxMTYiKuniTBRyKNEQf7D-lLFlByhRpZn-gRhkyopQ2p6TNp0jVu8pIQpIVIiVBxGURs1wW7zD6_IMS9N1kbHfl_WE9XGnf79wRna8fwPOFI5R41iudIXNsgokkuHrh_sQMfC
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV07T8MwED4VGICFR3m_PDCS0saPOIwgUAsUIQFSt8qJbVQBLYKUgV-Pz05KVTGwxXKiyOdPujv7u-8Ajp1byZvK6EgZKyOWG-wGmOWRi-xj5jyQSVOsd-7eifYTu-7xXg1OJrUwxhhPPjMNfPR3-XqUj_Go7JQJ5tIFOQcLnDHGQ7XW5ETFBSdUIBrLdAvx5u86UxYJmfSqsi7n0xit1J7KMa_qaZrpaeeye_4QWJblD72yaAv1fFtlE5aZINQ7o6sV6FbLCByUl8a4yBr594zC43_XuQobv2V_5H7i0NagZobrsDylWFiH1ymSERlZYtUAee1Em8JzuoYkSEMT9I6auPEX5uNhZvDsUEtclEw-3xxiCaI2CFgQ7KtdnJEOvl98jIhXvd2Ap6vLx4t2VDZsiAY0lkVEfQBnpRXc2VULGSvOdUskSnAlM0QFzVJqXczVNFTaJBZJpjED4i2lU0Y3YX44GpptIDbXSsXMNrlyCZtwiMkp11LmVOo0TpIdqKPd-u9Bk6NfmmwHtsK-TCaqjdv9-4MjWGw_dm_7t527mz1YCmwQPGDZh_niY2wOXMhRZIceaT-WpssP
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2008+30th+Annual+International+Conference+of+the+IEEE+Engineering+in+Medicine+and+Biology+Society&rft.atitle=Development+of+failure+detection+system+based+on+vibration+signal+for+smart+artificial+heart%3A+In+vitro+study&rft.au=Shinichi+Tsujimura&rft.au=Takashi+Kuwabara&rft.au=Harutoshi+Koguchi&rft.au=Takashi+Yamane&rft.date=2008-01-01&rft.pub=IEEE&rft.isbn=9781424418145&rft.issn=1094-687X&rft.spage=697&rft.epage=702&rft_id=info:doi/10.1109%2FIEMBS.2008.4649248&rft_id=info%3Apmid%2F19162751&rft.externalDocID=4649248
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1094-687X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1094-687X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1094-687X&client=summon