Shock wave overpressure testing system based on double external cavity fabry-perot interferometer

By using Double external cavity Fabry-Perot interferometer..DEFPI..to measure the shock wave overpressure generated during the explosion, Combined with Ansys/LS-dyna nonlinear finite element analysis, Simulation analysis of pressure cloud map of blast wave propagation in air and the pressure schedul...

Full description

Saved in:
Bibliographic Details
Published in2019 14th IEEE International Conference on Electronic Measurement & Instruments (ICEMI) pp. 1708 - 1713
Main Authors Hongyu, Zhang, Qi, Liu
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.11.2019
Subjects
Online AccessGet full text
DOI10.1109/ICEMI46757.2019.9101882

Cover

More Information
Summary:By using Double external cavity Fabry-Perot interferometer..DEFPI..to measure the shock wave overpressure generated during the explosion, Combined with Ansys/LS-dyna nonlinear finite element analysis, Simulation analysis of pressure cloud map of blast wave propagation in air and the pressure schedule with different explosion. Design sensor layout and accurately measure shock wave overpressure signals at various locations in the explosion field. The solution overcomes the instant, multi-point, electromagnetic interference, long distance transmission of the explosion process, can improve the Confidence level of weapon system damage effect assessment.