Automatic Motion Artifact Removal in ECG with Canonical Polyadic Decomposition

The electrocardiogram (ECG) is a reliable tool for monitoring cardiac conditions non-invasively. Its use is nowadays widespread and extends beyond purely medical purposes. Nevertheless, its application in residential settings comes with drawbacks. Non-stationary noise caused by motion reduces the si...

Full description

Saved in:
Bibliographic Details
Published in2021 29th European Signal Processing Conference (EUSIPCO) pp. 1291 - 1295
Main Authors Lilienthal, Jannis, Dargie, Waltenegus
Format Conference Proceeding
LanguageEnglish
Published EURASIP 23.08.2021
Subjects
Online AccessGet full text
ISSN2076-1465
DOI10.23919/EUSIPCO54536.2021.9616139

Cover

Abstract The electrocardiogram (ECG) is a reliable tool for monitoring cardiac conditions non-invasively. Its use is nowadays widespread and extends beyond purely medical purposes. Nevertheless, its application in residential settings comes with drawbacks. Non-stationary noise caused by motion reduces the signal's quality and alters the signal's characteristics. In this paper, we employ canonical polyadic decomposition (CPD) along with the measurements of a 3D accelerometer to characterize and remove artifacts. A CPD decomposes a noisy ECG into its constituting elements by examining multi-dimensional correlations. Its success, however, depends on how well the constituting elements are estimated to configure the model. The purpose of this paper is to achieve this task. We recorded data from ten healthy subjects undertaking different movement types: Standing up, bending forward, walking, running, jumping, and climbing stairs. In addition, we recorded isolated motion artifacts from the back of the subjects and mixed them with the ECG signals. To quantify the performance of the decomposition process, we compared the difference in the signal-to-noise ratio (SNR) and the root mean squared error (RMSE) between the actual and the estimated ECG. The proposed CPD model outperforms the adaptive filter and the wavelet denoising in terms of the SNR.
AbstractList The electrocardiogram (ECG) is a reliable tool for monitoring cardiac conditions non-invasively. Its use is nowadays widespread and extends beyond purely medical purposes. Nevertheless, its application in residential settings comes with drawbacks. Non-stationary noise caused by motion reduces the signal's quality and alters the signal's characteristics. In this paper, we employ canonical polyadic decomposition (CPD) along with the measurements of a 3D accelerometer to characterize and remove artifacts. A CPD decomposes a noisy ECG into its constituting elements by examining multi-dimensional correlations. Its success, however, depends on how well the constituting elements are estimated to configure the model. The purpose of this paper is to achieve this task. We recorded data from ten healthy subjects undertaking different movement types: Standing up, bending forward, walking, running, jumping, and climbing stairs. In addition, we recorded isolated motion artifacts from the back of the subjects and mixed them with the ECG signals. To quantify the performance of the decomposition process, we compared the difference in the signal-to-noise ratio (SNR) and the root mean squared error (RMSE) between the actual and the estimated ECG. The proposed CPD model outperforms the adaptive filter and the wavelet denoising in terms of the SNR.
Author Lilienthal, Jannis
Dargie, Waltenegus
Author_xml – sequence: 1
  givenname: Jannis
  surname: Lilienthal
  fullname: Lilienthal, Jannis
  email: jannis.lilienthal@tu-dresden.de
  organization: Technische Universität Dresden,Dresden,Germany,01062
– sequence: 2
  givenname: Waltenegus
  surname: Dargie
  fullname: Dargie, Waltenegus
  email: waltenegus.dargie@tu-dresden.de
  organization: Technische Universität Dresden,Dresden,Germany,01062
BookMark eNotj1FLwzAUhaMoOGd_gS_B986bpM1NHkft5mC64fR5pGmKgbUZbVT27624pwMHvo9zbslVFzpHyAODGRea6cfyY7faFps8y4WcceBspiWTTOgLkmhUGhRHjSDhkkw4oExZJvMbkgyDr4ArUMhATsjr_CuG1kRv6UuIPnR03kffGBvpm2vDtzlQ39GyWNIfHz9pYcYd3o7tNhxOph6xJ2dDewyD_6PvyHVjDoNLzjklu0X5Xjyn681yVczXqecgYoq1BeWsQVmjZoqbBqXKwfJG1xo5sxytES4TNddMMFllgJUyiJkyohFTcv9v9c65_bH3relP-_N_8Qspa1Ii
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.23919/EUSIPCO54536.2021.9616139
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 9789082797060
9082797062
EISSN 2076-1465
EndPage 1295
ExternalDocumentID 9616139
Genre orig-research
GrantInformation_xml – fundername: German Research Foundation (DFG)
  grantid: DA 1211/7-1
  funderid: 10.13039/501100001659
GroupedDBID 6IE
6IL
ALMA_UNASSIGNED_HOLDINGS
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i203t-7dc08eca76d79182af76850c2f9d9721c27ca3e43d291316b407b8a7748a3f3
IEDL.DBID RIE
IngestDate Wed Aug 27 05:11:14 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i203t-7dc08eca76d79182af76850c2f9d9721c27ca3e43d291316b407b8a7748a3f3
PageCount 5
ParticipantIDs ieee_primary_9616139
PublicationCentury 2000
PublicationDate 2021-Aug.-23
PublicationDateYYYYMMDD 2021-08-23
PublicationDate_xml – month: 08
  year: 2021
  text: 2021-Aug.-23
  day: 23
PublicationDecade 2020
PublicationTitle 2021 29th European Signal Processing Conference (EUSIPCO)
PublicationTitleAbbrev EUSIPCO
PublicationYear 2021
Publisher EURASIP
Publisher_xml – name: EURASIP
SSID ssib028087106
ssib025355106
Score 1.7708352
Snippet The electrocardiogram (ECG) is a reliable tool for monitoring cardiac conditions non-invasively. Its use is nowadays widespread and extends beyond purely...
SourceID ieee
SourceType Publisher
StartPage 1291
SubjectTerms Accelerometers
Electrocardiography
Feature extraction
inertial sensor
motion artifact
Noise measurement
tensor decomposition
Tensors
Three-dimensional displays
unsupervised machine learning
wireless electrocardiogram
Title Automatic Motion Artifact Removal in ECG with Canonical Polyadic Decomposition
URI https://ieeexplore.ieee.org/document/9616139
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NS8MwGA7bTp5UNvGbHDzark3aND2OujmFzeEc7DbS5A0MdRVpD_rrTdI6P_DgrbQ0DclL3488z_MidBGDLRrn1As5E16UCPMfBBp7gVKxjgAkuKZ9kykbL6LbZbxsocstFwYAHPgMfHvpzvJVIStbKuunzMQnNG2jdsJZzdX6tB0SG8f57cSQ8MCkAgGrdUYJTcO0P1zMb2bZnYkZqAUnkNBvBvzRWcU5ltEumnxOqcaTPPpVmfvy_Zda43_nvId6XxQ-PNs6p33Ugk0XTQdVWTiNVjxx3XvwwBiO5Tbge3gujNHh9QYPs2tsy7M4E5vC0SbxrHh6E8q8dgUWg94AvXpoPho-ZGOvaajgrUlASy9RMuAgRcJUkprEQmiTbMSBJDpVVsVHkkQKChFVJA1pyHKT7eVcmAiRC6rpAeqYz8IhwmCeExbHYMaJdBTkkeZaq1SBAK14eIS6diVWL7VixqpZhOO_b5-gHbsbtlJL6CnqlK8VnBlXX-bnbo8_AB6Hp3A
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1JT8JAFJ4gHvSkBoy7c_BooZ2ly5FUEJQiEUi4kWnnTUJUakx70F_vTFtwiQdvTZtOJzMvfct83_cQuuJgisYxtRzfFRbzhP4PAuWWLSVXDCCBomlfNHL7M3Y35_Maut5wYQCgAJ9By1wWZ_kyTXJTKmsHro5PaLCFtjljjJdsrbX1EK5d57czQ-LbOhmw3VJplNDACdrd2WQwDh901EANPIE4rWrIH71VCtfS20PRelIlouSplWdxK_n4pdf431nvo-YXiQ-PN-7pANVg1UCjTp6lhUorjor-PbijTcewG_AjvKTa7PByhbvhLTYFWhyKVVoQJ_E4fX4XUr92AwaFXkG9mmjS607DvlW1VLCWxKaZ5cnE9iERniu9QKcWQul0g9sJUYE0Oj4J8RJBgVFJAoc6bqzzvdgXOkb0BVX0ENX1Z-EIYdDPics56HGYYnbMlK-UDCQIUNJ3jlHDrMTitdTMWFSLcPL37Uu0059Gw8VwMLo_RbtmZ0zdltAzVM_ecjjXjj-LL4r9_gQU36q9
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2021+29th+European+Signal+Processing+Conference+%28EUSIPCO%29&rft.atitle=Automatic+Motion+Artifact+Removal+in+ECG+with+Canonical+Polyadic+Decomposition&rft.au=Lilienthal%2C+Jannis&rft.au=Dargie%2C+Waltenegus&rft.date=2021-08-23&rft.pub=EURASIP&rft.eissn=2076-1465&rft.spage=1291&rft.epage=1295&rft_id=info:doi/10.23919%2FEUSIPCO54536.2021.9616139&rft.externalDocID=9616139