Control of Reactive Power and Connection Voltage in Grid Connected Wind Turbine

Due to the development and progress of countries, with the passage of time, our need for electrical energy also increases, but electricity production relies on fossil energy sources, which are both running out and cause the production of greenhouse gases, but on the other hand, because energy is che...

Full description

Saved in:
Bibliographic Details
Published inInternational Symposium on Power Electronics, Electrical Drives, Automation and Motion pp. 503 - 508
Main Authors Karimi, Hamed, Tarassodi, Pouya, Siadatan, Alireza, Sepehrinour, Maryam
Format Conference Proceeding
LanguageEnglish
Published IEEE 19.06.2024
Subjects
Online AccessGet full text
ISSN2835-8457
DOI10.1109/SPEEDAM61530.2024.10609185

Cover

Abstract Due to the development and progress of countries, with the passage of time, our need for electrical energy also increases, but electricity production relies on fossil energy sources, which are both running out and cause the production of greenhouse gases, but on the other hand, because energy is cheap. Wind this renewable energy has been developed rapidly on a global scale. However, due to the fact that in wind power plants, wind speed will not always be constant and it is changing, this problem disturbs the balance of the power system and causes the voltage to always change, for this reason, the grids in which there is a wind turbine are different from each other. grids are different and many researches and studies have been done to solve this problem, and due to its many advantages, the Doubly Fed Induction Generator (DFIG) is considered to compensate for these problems, by using it, we will not need to compensate for additional reactive devices We had and can control the speed, active and reactive power.
AbstractList Due to the development and progress of countries, with the passage of time, our need for electrical energy also increases, but electricity production relies on fossil energy sources, which are both running out and cause the production of greenhouse gases, but on the other hand, because energy is cheap. Wind this renewable energy has been developed rapidly on a global scale. However, due to the fact that in wind power plants, wind speed will not always be constant and it is changing, this problem disturbs the balance of the power system and causes the voltage to always change, for this reason, the grids in which there is a wind turbine are different from each other. grids are different and many researches and studies have been done to solve this problem, and due to its many advantages, the Doubly Fed Induction Generator (DFIG) is considered to compensate for these problems, by using it, we will not need to compensate for additional reactive devices We had and can control the speed, active and reactive power.
Author Tarassodi, Pouya
Sepehrinour, Maryam
Siadatan, Alireza
Karimi, Hamed
Author_xml – sequence: 1
  givenname: Hamed
  surname: Karimi
  fullname: Karimi, Hamed
  email: h_karimi@sbu.ac.ir
  organization: Shahid Beheshti University,Department of Electrical Engineering,Tehran,Iran
– sequence: 2
  givenname: Pouya
  surname: Tarassodi
  fullname: Tarassodi, Pouya
  email: pouya.t@otaskies.com
  organization: OtaskiES Company,Gateshead,United Kingdom
– sequence: 3
  givenname: Alireza
  surname: Siadatan
  fullname: Siadatan, Alireza
  email: siadatan@yorku.ca
  organization: York University,Department of Electrical and Computer Science,Toronto,Canada
– sequence: 4
  givenname: Maryam
  surname: Sepehrinour
  fullname: Sepehrinour, Maryam
  email: maryam.sepehrinour@algomau.ca
  organization: Algoma University, Brampton Campus,Department of Computer Science and Technology,Ontario,Canada
BookMark eNo9UFtLwzAYjaLgnP0HPgTfW78kTdI8jrpNYbKhUx9Hsn6VSE0krYr_3oKXp8O5cOCcU3IUYkBCLhgUjIG5vN_M51ezW8WkgIIDLwsGCgyr5AHJjDaVkCAqLY05JBM-srwqpT4hWd-_AIAAMALkhKzrGIYUOxpbeod2P_gPpJv4iYna0NDRDTiKMdDH2A32GakPdJn8v4UNffJjcvuenA94Ro5b2_WY_eKUPCzm2_o6X62XN_VslXum1ZArLpxTjFfcSKsVtspawytWSi7HHS2CBKdRAyuFduDavTJt47SwRjglrJiS859ej4i7t-Rfbfra_X0gvgHYRFJZ
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/SPEEDAM61530.2024.10609185
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Xplore
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 9798350387599
EISSN 2835-8457
EndPage 508
ExternalDocumentID 10609185
Genre orig-research
GroupedDBID 6IE
6IF
6IH
6IK
6IL
6IN
AAJGR
ABLEC
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
IPLJI
M43
OCL
RIE
RIL
RNS
ID FETCH-LOGICAL-i176t-623bb6128295a76ef6aa92814525060fe050b7e701437b0bfc69fdb73a93b63a3
IEDL.DBID RIE
IngestDate Wed Aug 27 02:34:02 EDT 2025
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i176t-623bb6128295a76ef6aa92814525060fe050b7e701437b0bfc69fdb73a93b63a3
PageCount 6
ParticipantIDs ieee_primary_10609185
PublicationCentury 2000
PublicationDate 2024-June-19
PublicationDateYYYYMMDD 2024-06-19
PublicationDate_xml – month: 06
  year: 2024
  text: 2024-June-19
  day: 19
PublicationDecade 2020
PublicationTitle International Symposium on Power Electronics, Electrical Drives, Automation and Motion
PublicationTitleAbbrev SPEEDAM
PublicationYear 2024
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0003009305
Score 1.9010482
Snippet Due to the development and progress of countries, with the passage of time, our need for electrical energy also increases, but electricity production relies on...
SourceID ieee
SourceType Publisher
StartPage 503
SubjectTerms DC-DC Power Converters
Doubly-Fed Induction Generator
Generators
Maximum Power Point
Production
Reactive power
Reactive Power Control
Switches
Wind energy
Wind power generation
Wind speed
Wind Turbine
Wind turbines
Title Control of Reactive Power and Connection Voltage in Grid Connected Wind Turbine
URI https://ieeexplore.ieee.org/document/10609185
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwGA1uJ08qTvxNDl5b06ZJmqPMzSE4h26620jSLzCUVkZ78a83SbeJguAtNFBC0uZ9L_ne-xC6opkRBTMsKlLlCIoEEylgNBKaS2pdAJC0bp9jPppl93M2X4vVgxYGAELyGcS-Ge7yi8o0_qjM_eHcwVvOOqjjvrNWrLU9UKGenBO2NhZNiLx-ngwGtzcPPqQhjgmmWbx5wY9SKgFJhntovBlDm0DyFje1js3nL3vGfw9yH_W-RXt4soWjA7QD5SF67Lep6Liy-AlU2NzwxFdGw6oscEhzCcoG_FK9125vwcsS362W2y4o8Kuj7XjarByHhh6aDQfT_iha11CIlongdeSiG61dFJOnkinBwXKlZJon4TqTEwuEES1AeJs_oYm2hktbaEGVpJpTRY9Qt6xKOEZYW8uAc3CgJzMGVglgJpWQcpZlRpkT1POzsfhobTIWm4k4_eP5Gdr1i-LzrhJ5jrr1qoELh_C1vgwr-wVV96Qt
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFA46D3pSceJvc_Da2jZL0hxlbk7d5tBNvY0kfYGhtDLai3-9SbpNFARvpYUS8kje-5Lv-x5CF6SleUY1DbJEWoAiQAcSKAm4YoIYWwDEtdvnkPUmrbtX-roQq3stDAB48hmE7tHf5WeFrtxRmV3hzKa3lK6jDWphRVrLtVZHKsTB84gurEXjSFw-jTqd66uBK2oiiwWTVrj8xY9mKj6XdLfRcDmKmkLyFlalCvXnL4PGfw9zBzW_ZXt4tEpIu2gN8j300K7J6Lgw-BGk397wyPVGwzLPsCe6eG0Dfi7eS7u74FmOb-az1SfI8IsF7nhczS2KhiaadDvjdi9YdFEIZjFnZWDrG6VsHZMmgkrOwDApRZLG_kKTRQYiGikO3Bn9cRUpo5kwmeJECqIYkWQfNfIihwOElTEUGAOb9kSLgpEcqE4EJMyGQ0t9iJpuNqYftVHGdDkRR3-8P0ebvfGgP-3fDu-P0ZYLkGNhxeIENcp5Bac235fqzEf5Cyyjp4A
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=International+Symposium+on+Power+Electronics%2C+Electrical+Drives%2C+Automation+and+Motion&rft.atitle=Control+of+Reactive+Power+and+Connection+Voltage+in+Grid+Connected+Wind+Turbine&rft.au=Karimi%2C+Hamed&rft.au=Tarassodi%2C+Pouya&rft.au=Siadatan%2C+Alireza&rft.au=Sepehrinour%2C+Maryam&rft.date=2024-06-19&rft.pub=IEEE&rft.eissn=2835-8457&rft.spage=503&rft.epage=508&rft_id=info:doi/10.1109%2FSPEEDAM61530.2024.10609185&rft.externalDocID=10609185