A new LMS based algorithm to suppress dead-time effects in PMSM V/f drives

This paper presents a new least-mean-square (LMS) based algorithm to suppress dead-time distortion in permanent-magnet synchronous motor (PMSM) V/f control schemes. The PMSM V/f control schemes are merited for their simple structure compared with sensorless field-oriented control (FOC) schemes. Howe...

Full description

Saved in:
Bibliographic Details
Published inConference proceedings - IEEE Applied Power Electronics Conference and Exposition pp. 3156 - 3162
Main Authors Zhuangyao Tang, Akin, Bilal
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.03.2017
Subjects
Online AccessGet full text
ISSN2470-6647
DOI10.1109/APEC.2017.7931148

Cover

Abstract This paper presents a new least-mean-square (LMS) based algorithm to suppress dead-time distortion in permanent-magnet synchronous motor (PMSM) V/f control schemes. The PMSM V/f control schemes are merited for their simple structure compared with sensorless field-oriented control (FOC) schemes. However, among the proposed ones, there isn't any method developed specifically for dead-time compensation in V/f control schemes. In the proposed method, the LMS dead-time compensator can directly reduce the current harmonics induced by the dead time without depending on precise current sampling especially in the zero-crossing region. Unlike disturbance observer methods which are designed for FOC schemes, it can be applied to both FOC and V/f control schemes. It is also robust to parameter variations because of LMS algorithm's online adaptation capability. This method is tested on a 2.5 kW PMSM drive controlled by a V/f scheme and requires negligible extra CPU bandwidth. The fidelity is validated by experimental results and spectrum analysis.
AbstractList This paper presents a new least-mean-square (LMS) based algorithm to suppress dead-time distortion in permanent-magnet synchronous motor (PMSM) V/f control schemes. The PMSM V/f control schemes are merited for their simple structure compared with sensorless field-oriented control (FOC) schemes. However, among the proposed ones, there isn't any method developed specifically for dead-time compensation in V/f control schemes. In the proposed method, the LMS dead-time compensator can directly reduce the current harmonics induced by the dead time without depending on precise current sampling especially in the zero-crossing region. Unlike disturbance observer methods which are designed for FOC schemes, it can be applied to both FOC and V/f control schemes. It is also robust to parameter variations because of LMS algorithm's online adaptation capability. This method is tested on a 2.5 kW PMSM drive controlled by a V/f scheme and requires negligible extra CPU bandwidth. The fidelity is validated by experimental results and spectrum analysis.
Author Zhuangyao Tang
Akin, Bilal
Author_xml – sequence: 1
  surname: Zhuangyao Tang
  fullname: Zhuangyao Tang
  email: zxt130030@utdallas.edu
  organization: Electr. & Comput. Sci. Dept., Univ. of Texas at Dallas, Richardson, TX, USA
– sequence: 2
  givenname: Bilal
  surname: Akin
  fullname: Akin, Bilal
  email: bilal.akin@utdallas.edu
  organization: Electr. & Comput. Sci. Dept., Univ. of Texas at Dallas, Richardson, TX, USA
BookMark eNotj9tKw0AURUdRsKl-gPgyP5B0zlyTxxBqVRIsVH0tk8mJjjQXMlHx7y3Yp71gwYIdkYt-6JGQW2AJAMtW-XZdJJyBSUwmAGR6RiJQLGNKaM3PyYJLw2KtpbkiUQifjHFhQC_IU057_KFltaO1DdhQe3gfJj9_dHQeaPgaxwlDoA3aJp59hxTbFt0cqO_pttpV9G3V0mby3xiuyWVrDwFvTrskr_frl-IhLp83j0Vexh6MmmNUDefKZYI3aa1ZplwthZSSA3DL68xYwQS02jlQR-bMpSiUbi04VO7oluTuv-sRcT9OvrPT7_70W_wBH_NL0A
ContentType Conference Proceeding
DBID 6IE
6IH
CBEJK
RIE
RIO
DOI 10.1109/APEC.2017.7931148
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Proceedings Order Plan (POP) 1998-present by volume
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP) 1998-present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISBN 1509053662
9781509053667
EISSN 2470-6647
EndPage 3162
ExternalDocumentID 7931148
Genre orig-research
GroupedDBID 23M
29F
6IE
6IF
6IH
6IK
6IL
6IM
6IN
AAJGR
AAWTH
ABLEC
ACGFS
ADZIZ
ALMA_UNASSIGNED_HOLDINGS
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CBEJK
CHZPO
IEGSK
IJVOP
IPLJI
M43
OCL
RIE
RIL
RIO
RNS
ID FETCH-LOGICAL-i175t-e5d225c932d8b6095cb434442112a2b97a3031f6cc157a320c8e356fa1ce5c303
IEDL.DBID RIE
IngestDate Wed Aug 27 02:15:27 EDT 2025
IsPeerReviewed false
IsScholarly true
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i175t-e5d225c932d8b6095cb434442112a2b97a3031f6cc157a320c8e356fa1ce5c303
PageCount 7
ParticipantIDs ieee_primary_7931148
PublicationCentury 2000
PublicationDate 2017-March
PublicationDateYYYYMMDD 2017-03-01
PublicationDate_xml – month: 03
  year: 2017
  text: 2017-March
PublicationDecade 2010
PublicationTitle Conference proceedings - IEEE Applied Power Electronics Conference and Exposition
PublicationTitleAbbrev APEC
PublicationYear 2017
Publisher IEEE
Publisher_xml – name: IEEE
SSID ssj0023716
Score 2.0421727
Snippet This paper presents a new least-mean-square (LMS) based algorithm to suppress dead-time distortion in permanent-magnet synchronous motor (PMSM) V/f control...
SourceID ieee
SourceType Publisher
StartPage 3156
SubjectTerms Algorithm design and analysis
Dead-time compensation
Distortion
Harmonic analysis
Least-mean-square algorithm
Noise cancellation
Permanent-magnet synchronous motor (PMSM)
Power harmonic filters
Switches
V/f control
Voltage control
Title A new LMS based algorithm to suppress dead-time effects in PMSM V/f drives
URI https://ieeexplore.ieee.org/document/7931148
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1Lb4JAEJ6op_bShzZ9Zw89dlFgWeBojMaY0phYG2-GfdCaVjAWLv31nQVqH-mhtw1kgezsZr5hvvkG4EZx7oRe4lMhXEmZUDEVGNtSxRHM-75yqnRBdM_HczZZeIsG3O5qYbTWJflMW2ZY5vJVJgvzq6yLe8nA9yY0_YBXtVq74MpF4F9nLe1e2O1PhwND3PKtetKP7iml8xgdQPT52ooz8mIVubDk-y9Fxv9-1yF0vsr0yHTngI6godNj2P-mMNiGSZ8gbiZ30YwYf6VI_PqUbVf585rkGXkrNiUPlii0NDVt5knN7yCrlEyjWUQeuwlRW6NN24H5aPgwGNO6fQJdISbIqfYUHlaJAE0FwujKScFcxhiGfE7siNCP0X3ZCZfS9nDs9GSgXY8nsS21J_HeCbTSLNWnQGSgHKaTkNsqNE8IYl_YruoFsUwSxJhn0DarstxUChnLekHO_758AXvGMhWT6xJa-bbQV-jac3Fd2vQDpNGiBg
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4gHtSLDzC-3YNHF-hj-zgSAkGkhAQw3Ej3USVqS7C9-OudbSs-4sHbps22zUyb-abzzTcAN9JxTJ9FLuXcEtTmMqQcc1sqHQTzrivNolwQjJz-zB7M2bwCt5teGKVUTj5TDb3Ma_kyEZn-VdbEd0nD9y3YZrZts6Jba5NeWQj9y7ql0fKb7XG3o6lbbqPc9mN-Sh4-evsQfN64YI08N7KUN8T7L03G_z7ZAdS_GvXIeBOCDqGi4iPY-6YxWINBmyByJsNgQnTEkiR8eUzWy_TplaQJectWOROWSPQ11YPmScnwIMuYjINJQB6aEZFrrU5bh1mvO-30aTlAgS4RFaRUMYmfq0CIJj2uleUEty20HCZ9Zmhy3w0xgBmRI4TBcG22hKcs5kShIRQTeO4YqnESqxMgwpOmrSLfMaSvr-CFLjcs2fJCEUWIMk-hpq2yWBUaGYvSIGd_H76Gnf40GC6Gd6P7c9jVXip4XRdQTdeZusRAn_Kr3L8fU-2lUw
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=Conference+proceedings+-+IEEE+Applied+Power+Electronics+Conference+and+Exposition&rft.atitle=A+new+LMS+based+algorithm+to+suppress+dead-time+effects+in+PMSM+V%2Ff+drives&rft.au=Zhuangyao+Tang&rft.au=Akin%2C+Bilal&rft.date=2017-03-01&rft.pub=IEEE&rft.eissn=2470-6647&rft.spage=3156&rft.epage=3162&rft_id=info:doi/10.1109%2FAPEC.2017.7931148&rft.externalDocID=7931148