A new LMS based algorithm to suppress dead-time effects in PMSM V/f drives
This paper presents a new least-mean-square (LMS) based algorithm to suppress dead-time distortion in permanent-magnet synchronous motor (PMSM) V/f control schemes. The PMSM V/f control schemes are merited for their simple structure compared with sensorless field-oriented control (FOC) schemes. Howe...
        Saved in:
      
    
          | Published in | Conference proceedings - IEEE Applied Power Electronics Conference and Exposition pp. 3156 - 3162 | 
|---|---|
| Main Authors | , | 
| Format | Conference Proceeding | 
| Language | English | 
| Published | 
            IEEE
    
        01.03.2017
     | 
| Subjects | |
| Online Access | Get full text | 
| ISSN | 2470-6647 | 
| DOI | 10.1109/APEC.2017.7931148 | 
Cover
| Abstract | This paper presents a new least-mean-square (LMS) based algorithm to suppress dead-time distortion in permanent-magnet synchronous motor (PMSM) V/f control schemes. The PMSM V/f control schemes are merited for their simple structure compared with sensorless field-oriented control (FOC) schemes. However, among the proposed ones, there isn't any method developed specifically for dead-time compensation in V/f control schemes. In the proposed method, the LMS dead-time compensator can directly reduce the current harmonics induced by the dead time without depending on precise current sampling especially in the zero-crossing region. Unlike disturbance observer methods which are designed for FOC schemes, it can be applied to both FOC and V/f control schemes. It is also robust to parameter variations because of LMS algorithm's online adaptation capability. This method is tested on a 2.5 kW PMSM drive controlled by a V/f scheme and requires negligible extra CPU bandwidth. The fidelity is validated by experimental results and spectrum analysis. | 
    
|---|---|
| AbstractList | This paper presents a new least-mean-square (LMS) based algorithm to suppress dead-time distortion in permanent-magnet synchronous motor (PMSM) V/f control schemes. The PMSM V/f control schemes are merited for their simple structure compared with sensorless field-oriented control (FOC) schemes. However, among the proposed ones, there isn't any method developed specifically for dead-time compensation in V/f control schemes. In the proposed method, the LMS dead-time compensator can directly reduce the current harmonics induced by the dead time without depending on precise current sampling especially in the zero-crossing region. Unlike disturbance observer methods which are designed for FOC schemes, it can be applied to both FOC and V/f control schemes. It is also robust to parameter variations because of LMS algorithm's online adaptation capability. This method is tested on a 2.5 kW PMSM drive controlled by a V/f scheme and requires negligible extra CPU bandwidth. The fidelity is validated by experimental results and spectrum analysis. | 
    
| Author | Zhuangyao Tang Akin, Bilal  | 
    
| Author_xml | – sequence: 1 surname: Zhuangyao Tang fullname: Zhuangyao Tang email: zxt130030@utdallas.edu organization: Electr. & Comput. Sci. Dept., Univ. of Texas at Dallas, Richardson, TX, USA – sequence: 2 givenname: Bilal surname: Akin fullname: Akin, Bilal email: bilal.akin@utdallas.edu organization: Electr. & Comput. Sci. Dept., Univ. of Texas at Dallas, Richardson, TX, USA  | 
    
| BookMark | eNotj9tKw0AURUdRsKl-gPgyP5B0zlyTxxBqVRIsVH0tk8mJjjQXMlHx7y3Yp71gwYIdkYt-6JGQW2AJAMtW-XZdJJyBSUwmAGR6RiJQLGNKaM3PyYJLw2KtpbkiUQifjHFhQC_IU057_KFltaO1DdhQe3gfJj9_dHQeaPgaxwlDoA3aJp59hxTbFt0cqO_pttpV9G3V0mby3xiuyWVrDwFvTrskr_frl-IhLp83j0Vexh6MmmNUDefKZYI3aa1ZplwthZSSA3DL68xYwQS02jlQR-bMpSiUbi04VO7oluTuv-sRcT9OvrPT7_70W_wBH_NL0A | 
    
| ContentType | Conference Proceeding | 
    
| DBID | 6IE 6IH CBEJK RIE RIO  | 
    
| DOI | 10.1109/APEC.2017.7931148 | 
    
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan (POP) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP) 1998-present  | 
    
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher  | 
    
| DeliveryMethod | fulltext_linktorsrc | 
    
| Discipline | Engineering | 
    
| EISBN | 1509053662 9781509053667  | 
    
| EISSN | 2470-6647 | 
    
| EndPage | 3162 | 
    
| ExternalDocumentID | 7931148 | 
    
| Genre | orig-research | 
    
| GroupedDBID | 23M 29F 6IE 6IF 6IH 6IK 6IL 6IM 6IN AAJGR AAWTH ABLEC ACGFS ADZIZ ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK CHZPO IEGSK IJVOP IPLJI M43 OCL RIE RIL RIO RNS  | 
    
| ID | FETCH-LOGICAL-i175t-e5d225c932d8b6095cb434442112a2b97a3031f6cc157a320c8e356fa1ce5c303 | 
    
| IEDL.DBID | RIE | 
    
| IngestDate | Wed Aug 27 02:15:27 EDT 2025 | 
    
| IsPeerReviewed | false | 
    
| IsScholarly | true | 
    
| Language | English | 
    
| LinkModel | DirectLink | 
    
| MergedId | FETCHMERGED-LOGICAL-i175t-e5d225c932d8b6095cb434442112a2b97a3031f6cc157a320c8e356fa1ce5c303 | 
    
| PageCount | 7 | 
    
| ParticipantIDs | ieee_primary_7931148 | 
    
| PublicationCentury | 2000 | 
    
| PublicationDate | 2017-March | 
    
| PublicationDateYYYYMMDD | 2017-03-01 | 
    
| PublicationDate_xml | – month: 03 year: 2017 text: 2017-March  | 
    
| PublicationDecade | 2010 | 
    
| PublicationTitle | Conference proceedings - IEEE Applied Power Electronics Conference and Exposition | 
    
| PublicationTitleAbbrev | APEC | 
    
| PublicationYear | 2017 | 
    
| Publisher | IEEE | 
    
| Publisher_xml | – name: IEEE | 
    
| SSID | ssj0023716 | 
    
| Score | 2.0421727 | 
    
| Snippet | This paper presents a new least-mean-square (LMS) based algorithm to suppress dead-time distortion in permanent-magnet synchronous motor (PMSM) V/f control... | 
    
| SourceID | ieee | 
    
| SourceType | Publisher | 
    
| StartPage | 3156 | 
    
| SubjectTerms | Algorithm design and analysis Dead-time compensation Distortion Harmonic analysis Least-mean-square algorithm Noise cancellation Permanent-magnet synchronous motor (PMSM) Power harmonic filters Switches V/f control Voltage control  | 
    
| Title | A new LMS based algorithm to suppress dead-time effects in PMSM V/f drives | 
    
| URI | https://ieeexplore.ieee.org/document/7931148 | 
    
| hasFullText | 1 | 
    
| inHoldings | 1 | 
    
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1Lb4JAEJ6op_bShzZ9Zw89dlFgWeBojMaY0phYG2-GfdCaVjAWLv31nQVqH-mhtw1kgezsZr5hvvkG4EZx7oRe4lMhXEmZUDEVGNtSxRHM-75yqnRBdM_HczZZeIsG3O5qYbTWJflMW2ZY5vJVJgvzq6yLe8nA9yY0_YBXtVq74MpF4F9nLe1e2O1PhwND3PKtetKP7iml8xgdQPT52ooz8mIVubDk-y9Fxv9-1yF0vsr0yHTngI6godNj2P-mMNiGSZ8gbiZ30YwYf6VI_PqUbVf585rkGXkrNiUPlii0NDVt5knN7yCrlEyjWUQeuwlRW6NN24H5aPgwGNO6fQJdISbIqfYUHlaJAE0FwujKScFcxhiGfE7siNCP0X3ZCZfS9nDs9GSgXY8nsS21J_HeCbTSLNWnQGSgHKaTkNsqNE8IYl_YruoFsUwSxJhn0DarstxUChnLekHO_758AXvGMhWT6xJa-bbQV-jac3Fd2vQDpNGiBg | 
    
| linkProvider | IEEE | 
    
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEJ4gHtSLDzC-3YNHF-hj-zgSAkGkhAQw3Ej3USVqS7C9-OudbSs-4sHbps22zUyb-abzzTcAN9JxTJ9FLuXcEtTmMqQcc1sqHQTzrivNolwQjJz-zB7M2bwCt5teGKVUTj5TDb3Ma_kyEZn-VdbEd0nD9y3YZrZts6Jba5NeWQj9y7ql0fKb7XG3o6lbbqPc9mN-Sh4-evsQfN64YI08N7KUN8T7L03G_z7ZAdS_GvXIeBOCDqGi4iPY-6YxWINBmyByJsNgQnTEkiR8eUzWy_TplaQJectWOROWSPQ11YPmScnwIMuYjINJQB6aEZFrrU5bh1mvO-30aTlAgS4RFaRUMYmfq0CIJj2uleUEty20HCZ9Zmhy3w0xgBmRI4TBcG22hKcs5kShIRQTeO4YqnESqxMgwpOmrSLfMaSvr-CFLjcs2fJCEUWIMk-hpq2yWBUaGYvSIGd_H76Gnf40GC6Gd6P7c9jVXip4XRdQTdeZusRAn_Kr3L8fU-2lUw | 
    
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=proceeding&rft.title=Conference+proceedings+-+IEEE+Applied+Power+Electronics+Conference+and+Exposition&rft.atitle=A+new+LMS+based+algorithm+to+suppress+dead-time+effects+in+PMSM+V%2Ff+drives&rft.au=Zhuangyao+Tang&rft.au=Akin%2C+Bilal&rft.date=2017-03-01&rft.pub=IEEE&rft.eissn=2470-6647&rft.spage=3156&rft.epage=3162&rft_id=info:doi/10.1109%2FAPEC.2017.7931148&rft.externalDocID=7931148 |