Protection Coordination with Static Security Assessment

Protection coordination considering network security constraints is a challenging task. Power networks are designed to operate properly even under N −1 contingencies caused by the outage of some major components, such as power conductor, transformer, and generator. However, maintaining proper coordi...

Full description

Saved in:
Bibliographic Details
Published in2022 IEEE Delhi Section Conference (DELCON) pp. 1 - 6
Main Author Alam, Mahamad Nabab
Format Conference Proceeding
LanguageEnglish
Published IEEE 11.02.2022
Subjects
Online AccessGet full text
DOI10.1109/DELCON54057.2022.9753213

Cover

Abstract Protection coordination considering network security constraints is a challenging task. Power networks are designed to operate properly even under N −1 contingencies caused by the outage of some major components, such as power conductor, transformer, and generator. However, maintaining proper coordination among protective relays is difficult under such contingencies in interconnected power distribution networks. In this paper, the optimum protection coordination scheme of directional overcurrent relays, considering allowable N −1 contingencies, has been presented. This scheme provides a single setting-group of relays to provide proper protection coordination under all allowable contingencies in the system. This protection coordination problem has been formulated as a mixed-integer programming problem and solved using an interior-point method based algorithm. For selecting the allowable contingencies, a composite security index has been used. The effectiveness and suitability of the obtained settings have been demonstrated in the IEEE 14 bus test system.
AbstractList Protection coordination considering network security constraints is a challenging task. Power networks are designed to operate properly even under N −1 contingencies caused by the outage of some major components, such as power conductor, transformer, and generator. However, maintaining proper coordination among protective relays is difficult under such contingencies in interconnected power distribution networks. In this paper, the optimum protection coordination scheme of directional overcurrent relays, considering allowable N −1 contingencies, has been presented. This scheme provides a single setting-group of relays to provide proper protection coordination under all allowable contingencies in the system. This protection coordination problem has been formulated as a mixed-integer programming problem and solved using an interior-point method based algorithm. For selecting the allowable contingencies, a composite security index has been used. The effectiveness and suitability of the obtained settings have been demonstrated in the IEEE 14 bus test system.
Author Alam, Mahamad Nabab
Author_xml – sequence: 1
  givenname: Mahamad Nabab
  surname: Alam
  fullname: Alam, Mahamad Nabab
  email: mnalam@nitw.ac.in
  organization: National Institute of Technology Warangal,Department of Electrical Engineering,Warangal,India,506004
BookMark eNotj8tKAzEYhSPowlafwE1eYMbc_2RZxnqBwQpt1yUm_2DAJjITkb691XZ1-Djwcc6MXOaSkRDKWcs5c_cPy75bvWrFNLSCCdE60FJweUFm3BittLXSXBN4G0vFUFPJtCtljCn7f_hJ9YOu6xECXWP4HlM90MU04TTtMdcbcjX4zwlvzzkn28flpntu-tXTS7fom8S5rY0DpyV3YLxnVvJ3GKQIymjNACEoZ4OOEGGAaMFiDIopQOuO44T66-Sc3J28CRF3X2Pa-_GwO3-RvxEHQ-w
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/DELCON54057.2022.9753213
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 1665458836
9781665458832
EndPage 6
ExternalDocumentID 9753213
Genre orig-research
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i118t-979531976aa0831b7f32c465507e7c498c5d7d7f7d878edc4047e89588248c5d3
IEDL.DBID RIE
IngestDate Thu Jun 29 18:36:58 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i118t-979531976aa0831b7f32c465507e7c498c5d7d7f7d878edc4047e89588248c5d3
PageCount 6
ParticipantIDs ieee_primary_9753213
PublicationCentury 2000
PublicationDate 2022-Feb.-11
PublicationDateYYYYMMDD 2022-02-11
PublicationDate_xml – month: 02
  year: 2022
  text: 2022-Feb.-11
  day: 11
PublicationDecade 2020
PublicationTitle 2022 IEEE Delhi Section Conference (DELCON)
PublicationTitleAbbrev DELCON
PublicationYear 2022
Publisher IEEE
Publisher_xml – name: IEEE
Score 1.7878877
Snippet Protection coordination considering network security constraints is a challenging task. Power networks are designed to operate properly even under N −1...
SourceID ieee
SourceType Publisher
StartPage 1
SubjectTerms Coordination time interval
directional overcurrent relays
Generators
IEEE Sections
Network security
Network topology
Programming
protection coordination
Protective relaying
security assessment
Transformers
Title Protection Coordination with Static Security Assessment
URI https://ieeexplore.ieee.org/document/9753213
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFH7MnTypbOJvcvBouzZLm_Qoc2OImwMd7DbS5AWK0Il0F_9689puonjwVtJCmpTwfe_1ve8DuE0VJtoqDKzTNhAu9kfKE9fAZS4xkfEAwanBeTZPp0vxuEpWHbjb98IgYl18hiFd1v_y7cZsKVU2oCZQTha1B1KlTa_WrjgnygYP46fR87xmID7u4zxsH__hm1LDxuQIZrsJm2qRt3Bb5aH5_KXF-N83Oob-d4MeW-yh5wQ6WPZALhrNBb_TbLTxQWXRZPoY5VoZscrCsJfWr47d7yU5-7CcjF9H06D1RQgKHw5UQSYzOjky1Zp8wnLphtyQDlokURqRKZNYaaWTVkmF1ohISFRZ4sm0oHvDU-iWmxLPgHGlFfqQxnjWJnTsockZ4RLNdWTjPBXn0KNFr98b6Yt1u96Lv4cv4ZA2noqa4_gKutXHFq89Zlf5Tf2xvgCbS5e_
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFH6MedCTyib-NgePtmuzpEmPMjembnPgBruNND9gCKtId_GvN6_tJooHbyWlpGkI3_de3_s-gNtEWq6MtIFxygTMxf5IeeIauNRxHWkPEBQbnMeTZDhnTwu-aMDdrhfGWlsWn9kQL8t_-SbXG0yVdbAJlKJF7R5njPGqW2tbnhOlnYf-qPcyKTmIj_woDesHfjinlMAxOITxdsqqXuQt3BRZqD9_qTH-952OoP3dokemO_A5hoZdt0BMK9UF_61JL_dh5arK9RHMthLklStNXmvHOnK_E-Vsw3zQn_WGQe2MEKx8QFAEqUjx7IhEKXQKy4TrUo1KaJGwQrNUam6EEU4YKaQ1mkVMWJlyT6cZ3uueQHOdr-0pECqVtD6o0Z63MRV7cHKaOa6oikycJewMWrjo5XslfrGs13v-9_AN7A9n49Fy9Dh5voAD3AQscY7jS2gWHxt75RG8yK7LjfsCwWubDA
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2022+IEEE+Delhi+Section+Conference+%28DELCON%29&rft.atitle=Protection+Coordination+with+Static+Security+Assessment&rft.au=Alam%2C+Mahamad+Nabab&rft.date=2022-02-11&rft.pub=IEEE&rft.spage=1&rft.epage=6&rft_id=info:doi/10.1109%2FDELCON54057.2022.9753213&rft.externalDocID=9753213