Control of DSTATCOM using Sigmoidal Cost Based Logarithmic Algorithms in Grid Connected Distribution Systems
This paper presents simulation of control of DSTATCOM for the application of power quality improvement in grid connected system using Sigmoid Cost framework based Least Mean Logarithmic Square and Least Logarithmic Absolute Difference algorithms. The DSTATCOM is used for compensating harmonic curren...
        Saved in:
      
    
          | Published in | 2022 International Conference on Electronics and Renewable Systems (ICEARS) pp. 260 - 265 | 
|---|---|
| Main Authors | , | 
| Format | Conference Proceeding | 
| Language | English | 
| Published | 
            IEEE
    
        16.03.2022
     | 
| Subjects | |
| Online Access | Get full text | 
| DOI | 10.1109/ICEARS53579.2022.9752434 | 
Cover
| Abstract | This paper presents simulation of control of DSTATCOM for the application of power quality improvement in grid connected system using Sigmoid Cost framework based Least Mean Logarithmic Square and Least Logarithmic Absolute Difference algorithms. The DSTATCOM is used for compensating harmonic current and improving power factor at the point of common coupling. The performance of the algorithms is compared with the basic LMS algorithm. The results are shown under different loading conditions for settling time of DC bus voltage, THD in source voltage and current, weight convergence rate, oscillations under both steady state and dynamic conditions. The simulation, performance analysis and comparison are done using MATLAB/Simulink. | 
    
|---|---|
| AbstractList | This paper presents simulation of control of DSTATCOM for the application of power quality improvement in grid connected system using Sigmoid Cost framework based Least Mean Logarithmic Square and Least Logarithmic Absolute Difference algorithms. The DSTATCOM is used for compensating harmonic current and improving power factor at the point of common coupling. The performance of the algorithms is compared with the basic LMS algorithm. The results are shown under different loading conditions for settling time of DC bus voltage, THD in source voltage and current, weight convergence rate, oscillations under both steady state and dynamic conditions. The simulation, performance analysis and comparison are done using MATLAB/Simulink. | 
    
| Author | Bisht, Neeraj Singh Arora, Ankita  | 
    
| Author_xml | – sequence: 1 givenname: Neeraj Singh surname: Bisht fullname: Bisht, Neeraj Singh email: neerajsinghbisht4@gmail.com organization: Delhi Technological University,Department of Electrical Engineering,Delhi,India – sequence: 2 givenname: Ankita surname: Arora fullname: Arora, Ankita email: aroraankita985@gmail.com organization: Delhi Technological University,Department of Electrical Engineering,Delhi,India  | 
    
| BookMark | eNotkL1OwzAYRY0EAy08AYtfIMG_cTKGtJRKQZVIkNgqJ7HDJyU2it2hb08FXe65w9Ed7grdOu8MQpiSlFJSPO-rbfnRSC5VkTLCWFooyQQXN2hFs0yKXDD5dY-myru4-Al7izdNW7bV4R2fArgRNzDOHgY94cqHiF90MAOu_agXiN8z9LicRv_XAwaHdwsMF9M508eLuIEQF-hOEbzDzTlEM4cHdGf1FMzjlWv0-bptq7ekPuz2VVknQGkeE6G6rONUWcZzRmVXCCUMy7hRBc2INZZwLbgtek6yTkrGLpkPPR_UoGVPDF-jp_9dMMYcfxaY9XI-Xg_gvw6JVrE | 
    
| ContentType | Conference Proceeding | 
    
| DBID | 6IE 6IL CBEJK RIE RIL  | 
    
| DOI | 10.1109/ICEARS53579.2022.9752434 | 
    
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Proceedings Order Plan All Online (POP All Online) 1998-present by volume IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present  | 
    
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher  | 
    
| DeliveryMethod | fulltext_linktorsrc | 
    
| EISBN | 166548425X 9781665484251  | 
    
| EndPage | 265 | 
    
| ExternalDocumentID | 9752434 | 
    
| Genre | orig-research | 
    
| GroupedDBID | 6IE 6IL CBEJK RIE RIL  | 
    
| ID | FETCH-LOGICAL-i118t-47b6b317f238215b9474e263e79160fef03a43f9c306b55226b58dc3d7da5c0e3 | 
    
| IEDL.DBID | RIE | 
    
| IngestDate | Wed Aug 27 02:40:42 EDT 2025 | 
    
| IsPeerReviewed | false | 
    
| IsScholarly | false | 
    
| Language | English | 
    
| LinkModel | DirectLink | 
    
| MergedId | FETCHMERGED-LOGICAL-i118t-47b6b317f238215b9474e263e79160fef03a43f9c306b55226b58dc3d7da5c0e3 | 
    
| PageCount | 6 | 
    
| ParticipantIDs | ieee_primary_9752434 | 
    
| PublicationCentury | 2000 | 
    
| PublicationDate | 2022-March-16 | 
    
| PublicationDateYYYYMMDD | 2022-03-16 | 
    
| PublicationDate_xml | – month: 03 year: 2022 text: 2022-March-16 day: 16  | 
    
| PublicationDecade | 2020 | 
    
| PublicationTitle | 2022 International Conference on Electronics and Renewable Systems (ICEARS) | 
    
| PublicationTitleAbbrev | ICEARS | 
    
| PublicationYear | 2022 | 
    
| Publisher | IEEE | 
    
| Publisher_xml | – name: IEEE | 
    
| Score | 1.7915214 | 
    
| Snippet | This paper presents simulation of control of DSTATCOM for the application of power quality improvement in grid connected system using Sigmoid Cost framework... | 
    
| SourceID | ieee | 
    
| SourceType | Publisher | 
    
| StartPage | 260 | 
    
| SubjectTerms | Costs DSTATCOM Harmonic analysis Heuristic algorithms LMS algorithm Loading Power Quality Power System Power system harmonics Reactive power Sigmoid Steady-state  | 
    
| Title | Control of DSTATCOM using Sigmoidal Cost Based Logarithmic Algorithms in Grid Connected Distribution Systems | 
    
| URI | https://ieeexplore.ieee.org/document/9752434 | 
    
| hasFullText | 1 | 
    
| inHoldings | 1 | 
    
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PT8IwFG6Akyc1aPydHjy6Udpu3Y44QDSiRiDhRvpruAibgXHxr7fdBkbjwVvTNGnz3uH7Xt_33gPgmnJD2zjDDsE8dqiQ1AmobjtYyrZSmNtcjVVbPPmDCX2YetMauNnVwmitC_GZdu2yyOWrTG7sV1krZB6mhNZBnQV-Wau1FeegsHUf9TqvI494zBagYOxWx3_MTSlgo78PhtsLS7XIu7vJhSs_f_Vi_O-LDsDRd4EefNlBzyGo6bQJFlEpO4dZDLujcWccPQ-h1bXP4SiZL7NE8QWMsnUObw10KfiYzU2gnL8tEwk7i3lWrNcwSeHdKlGwkMBIQ0hh1zbXreZiwarF-RGY9HvjaOBUwxScxMQQuUOZ8IUhC7HBaAPzIqSMauwTzQxBRLGOEeGUxKE0MYTwLCsTXqAkUUxxTyJNjkEjzVJ9AqBmSCAVCIKwpFxrIYigNrQMtEREkFPQtJaafZT9MmaVkc7-3j4He9ZbVtfV9i9AI19t9KUB-lxcFR7-AphDqmY | 
    
| linkProvider | IEEE | 
    
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1LT8JAEN4gHvSkBoxv9-DRlrKPPo5YQFRAIyXhRrqP1kagBsrFX-9uWzAaD942m2x2M3P4vtn5ZgaAGxIq2hY6yMAojAzCODFcIpsG4rwpBAp1rkarLYZ2b0weJ3RSAbfbWhgpZS4-k6Ze5rl8kfK1_ipreA5FBJMdsEsJIbSo1trIcyyv8eB3Wq8jiqmjS1AQMssDPyan5MDRPQCDzZWFXuTdXGfM5J-_ujH-902HoP5dogdftuBzBCpyUQMzvxCewzSC7VHQCvznAdTK9hiOknieJiKcQT9dZfBOgZeA_TRWoXL2Nk84bM3iNF-vYLKA98tEwFwEwxUlhW3dXrecjAXLJud1MO52Ar9nlOMUjERFEZlBHGYzRRcihdIK6JlHHCKRjaWjKKIVycjCIcGRx1UUwajmZYy6gmPhiJByS-JjUF2kC3kCoHQsZgmXYQtxEkrJGGZEB5eu5BZm-BTUtKWmH0XHjGlppLO_t6_BXi8Y9Kf9h-HTOdjXntMqr6Z9AarZci0vFexn7Cr39hexca2z | 
    
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2022+International+Conference+on+Electronics+and+Renewable+Systems+%28ICEARS%29&rft.atitle=Control+of+DSTATCOM+using+Sigmoidal+Cost+Based+Logarithmic+Algorithms+in+Grid+Connected+Distribution+Systems&rft.au=Bisht%2C+Neeraj+Singh&rft.au=Arora%2C+Ankita&rft.date=2022-03-16&rft.pub=IEEE&rft.spage=260&rft.epage=265&rft_id=info:doi/10.1109%2FICEARS53579.2022.9752434&rft.externalDocID=9752434 |