Noninvasive Continuous Blood Pressure Estimation Algorithm Based on Features of Pulse Waves

Hypertension has become one of the main threats to human health. How to accurately and conveniently obtain the information of blood pressure (BP) continuously is the prerequisite for effective prevention and treatment of hypertension. In this paper, we develop a new algorithm to realize continuous n...

Full description

Saved in:
Bibliographic Details
Published in2019 12th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI) pp. 1 - 6
Main Authors Li, Xia, Li, Shuyin, Fang, Zhen, Zhou, Qinwu
Format Conference Proceeding
LanguageEnglish
Published IEEE 01.10.2019
Subjects
Online AccessGet full text
DOI10.1109/CISP-BMEI48845.2019.8965820

Cover

Abstract Hypertension has become one of the main threats to human health. How to accurately and conveniently obtain the information of blood pressure (BP) continuously is the prerequisite for effective prevention and treatment of hypertension. In this paper, we develop a new algorithm to realize continuous noninvasive BP estimation. Based on the pulse and BP waves in Medical Information Mart for Intensive Care (MIMIC) database, we exploit all available features (78 time-frequency features) of pulse waves extracted from different domains to build BP estimation model based on Elman neural network. In addition, to increase the accuracy of estimation, we use the Mean Impact Value (MIV) algorithm to select the features having the significant influence on BP prediction for each independent subject from the 78 features, and the Particle Swarm Optimization (PSO) algorithm is used to optimize network structure. The method complies with the Association for the Advancement of Medical Instrumentation (AAMI) standard in the estimation of systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. The results indicate that the proposed algorithm for the noninvasive estimation of the BP has certain significance for promoting continuous BP monitoring using mobile health-care gadgets.
AbstractList Hypertension has become one of the main threats to human health. How to accurately and conveniently obtain the information of blood pressure (BP) continuously is the prerequisite for effective prevention and treatment of hypertension. In this paper, we develop a new algorithm to realize continuous noninvasive BP estimation. Based on the pulse and BP waves in Medical Information Mart for Intensive Care (MIMIC) database, we exploit all available features (78 time-frequency features) of pulse waves extracted from different domains to build BP estimation model based on Elman neural network. In addition, to increase the accuracy of estimation, we use the Mean Impact Value (MIV) algorithm to select the features having the significant influence on BP prediction for each independent subject from the 78 features, and the Particle Swarm Optimization (PSO) algorithm is used to optimize network structure. The method complies with the Association for the Advancement of Medical Instrumentation (AAMI) standard in the estimation of systolic blood pressure (SBP) and diastolic blood pressure (DBP) values. The results indicate that the proposed algorithm for the noninvasive estimation of the BP has certain significance for promoting continuous BP monitoring using mobile health-care gadgets.
Author Li, Shuyin
Zhou, Qinwu
Li, Xia
Fang, Zhen
Author_xml – sequence: 1
  givenname: Xia
  surname: Li
  fullname: Li, Xia
  organization: School of Life Science and Technology, Xi'an Jiaotong University,Department of Biomedical Engineering,Xi'an,China
– sequence: 2
  givenname: Shuyin
  surname: Li
  fullname: Li, Shuyin
  organization: School of Life Science and Technology, Xi'an Jiaotong University,Department of Biomedical Engineering,Xi'an,China
– sequence: 3
  givenname: Zhen
  surname: Fang
  fullname: Fang, Zhen
  organization: School of Life Science and Technology, Xi'an Jiaotong University,Department of Biomedical Engineering,Xi'an,China
– sequence: 4
  givenname: Qinwu
  surname: Zhou
  fullname: Zhou, Qinwu
  organization: School of Life Science and Technology, Xi'an Jiaotong University,Department of Biomedical Engineering,Xi'an,China
BookMark eNotj8FLwzAYxSPowU3_Ai8Bz635vjY2OW6l08HUgYoHDyNrv2hgS6RJC_73Ftzp8R4_Hu_N2LkPnhi7BZEDCH1Xr1-32fKpWZdKlTJHATpX-l4qFGdsBhUqKJVEfck-n4N3fjTRjcTr4JPzQxgiXx5C6Pi2pxiHnngTkzua5ILni8NX6F36PvKlidTxKVqRSRMVebB8Oxwi8Q8zUrxiF9ZM7vqkc_a-at7qx2zz8rCuF5vMAaiUgZFlYdtKUCENtkLhHiWgBaw6VerWKFt2e5K60NhWIDuFaI1GIUEbLWwxZzf_vY6Idj_9tLT_3Z3-Fn9f41H9
ContentType Conference Proceeding
DBID 6IE
6IL
CBEJK
RIE
RIL
DOI 10.1109/CISP-BMEI48845.2019.8965820
DatabaseName IEEE Electronic Library (IEL) Conference Proceedings
IEEE Xplore POP ALL
IEEE Xplore All Conference Proceedings
IEEE Electronic Library (IEL)
IEEE Proceedings Order Plans (POP All) 1998-Present
DatabaseTitleList
Database_xml – sequence: 1
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
EISBN 1728148529
9781728148526
EndPage 6
ExternalDocumentID 8965820
Genre orig-research
GroupedDBID 6IE
6IL
CBEJK
RIE
RIL
ID FETCH-LOGICAL-i118t-1a543fc70e35a2c082b2512f127d849ca8f4dbe59392c715d822fa920519a90f3
IEDL.DBID RIE
IngestDate Thu Jun 29 18:38:10 EDT 2023
IsPeerReviewed false
IsScholarly false
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-i118t-1a543fc70e35a2c082b2512f127d849ca8f4dbe59392c715d822fa920519a90f3
PageCount 6
ParticipantIDs ieee_primary_8965820
PublicationCentury 2000
PublicationDate 2019-Oct.
PublicationDateYYYYMMDD 2019-10-01
PublicationDate_xml – month: 10
  year: 2019
  text: 2019-Oct.
PublicationDecade 2010
PublicationTitle 2019 12th International Congress on Image and Signal Processing, BioMedical Engineering and Informatics (CISP-BMEI)
PublicationTitleAbbrev CISP-BMEI
PublicationYear 2019
Publisher IEEE
Publisher_xml – name: IEEE
Score 1.7172567
Snippet Hypertension has become one of the main threats to human health. How to accurately and conveniently obtain the information of blood pressure (BP) continuously...
SourceID ieee
SourceType Publisher
StartPage 1
SubjectTerms Biomedical monitoring
Blood pressure
component
Current measurement
Elman neural network
Estimation
Feature extraction
Frequency-domain analysis
mean impact value
Particle Swarm Optimization
pulse wave
time-frequency features
Title Noninvasive Continuous Blood Pressure Estimation Algorithm Based on Features of Pulse Waves
URI https://ieeexplore.ieee.org/document/8965820
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3PS8MwFA5zB_Gksom_CejRbGvTLs3RjckmbAx0OPAw0uRFh9rK1u7gX-9LOyeKB28ltGnJD77vpd_3HiGXQoDmIY-ZJ23MgshYJkED4wgt0DbKtI0zJw9H7f4kuJ2G0wq52nhhAKAQn0HDXRb_8k2qc3dU1oxcphIfA_QtEbVLr9Y2uVinzWx2B3dj1hn2Brgmg9CptnAZlE_8KJ1SIMfNLhl-vbMUjLw08ixu6I9f6Rj_-1F7pP7t0aPjDfrskwokNfI4cqerK-U06dQlnponOYb2tOPk6bS0Ai6A9nBfl5ZFev36lC7m2fMb7SCeGYpNjhXiXUuaWjrOETrpg1rBsk4mN737bp-tyyewOUYNGfNUGHCrRQt4qHyNWB87MmM9X5gokFpFNjAxhBIpkhZeaJArWCV9R-qUbFl-QKpJmsAhobErSmysJwXwQFopBdfYJ5JL8F1JqyNScwMzey8zZMzWY3L8d_MJ2XGTU0riTkk1W-RwhtCexefFnH4CreWl6w
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1dT8IwFG2IJuqTGjB-20QfHbCtZeujEAgoIyRCJPGBbO2tEnUzsPHgr_d2Q4zGB9-WZuuWfuSc251zLyFXngfS5W5k2UJHFvOVtgRIsFyEFmioUDWUMScHg0Z3zG4nfFIi12svDADk4jOomsv8X75KZGaOymq-yVTiYIC-yRljvHBrbZHLVeLMWqt3P7SaQbuHq5Jxo9vChVA886N4So4dnV0SfL21kIy8VLM0qsqPXwkZ__tZe6Ty7dKjwzX-7JMSxGXyODDnq8vQqNKpST01izMM7mnTCNRpYQacA23jzi5Mi_Tm9SmZz9LnN9pERFMUmwwvxLsWNNF0mCF40odwCYsKGXfao1bXWhVQsGYYN6SWHXLmaunVweWhIxHtI0NntO14ymdChr5mKgIukCRJz-YK2YIOhWNoXSjq2j0gG3ESwyGhkSlLrLQtPHCZ0EJ4rsQ-kV6CY4paHZGyGZjpe5EjY7oak-O_my_IdncU9Kf93uDuhOyYiSoEcqdkI51ncIZAn0bn-fx-Ao2_qTg
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2019+12th+International+Congress+on+Image+and+Signal+Processing%2C+BioMedical+Engineering+and+Informatics+%28CISP-BMEI%29&rft.atitle=Noninvasive+Continuous+Blood+Pressure+Estimation+Algorithm+Based+on+Features+of+Pulse+Waves&rft.au=Li%2C+Xia&rft.au=Li%2C+Shuyin&rft.au=Fang%2C+Zhen&rft.au=Zhou%2C+Qinwu&rft.date=2019-10-01&rft.pub=IEEE&rft.spage=1&rft.epage=6&rft_id=info:doi/10.1109%2FCISP-BMEI48845.2019.8965820&rft.externalDocID=8965820