The research & practice of the on line monitoring methods for the capacitance to ground & grounding fault resistance of the networks
Measuring of the single phase grounding fault resistance is a main subject in the fault management of the neutral non-effectively earthed system. And for the measuring of the grounding fault resistance, the important sector is the measuring of the capacitance to ground. Though there are some measure...
        Saved in:
      
    
          | Published in | 7th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2006) p. 241 | 
|---|---|
| Main Author | |
| Format | Conference Proceeding | 
| Language | English | 
| Published | 
        Stevenage
          IET
    
        2006
     | 
| Subjects | |
| Online Access | Get full text | 
| ISBN | 9780863412462 0863412467  | 
| DOI | 10.1049/cp:20062094 | 
Cover
| Abstract | Measuring of the single phase grounding fault resistance is a main subject in the fault management of the neutral non-effectively earthed system. And for the measuring of the grounding fault resistance, the important sector is the measuring of the capacitance to ground. Though there are some measures currently use but their accuracy are rather low. In this paper, we introduced two new different methods for measuring the capacitance to ground of the networks. Fornon-grounding neutral system and neutral compensating system. And on such base the grounding fault resistance can be finally calculated. (5 pages) | 
    
|---|---|
| AbstractList | Measuring of the single phase grounding fault resistance is a main subject in the fault management of the neutral non-effectively earthed system. And for the measuring of the grounding fault resistance, the important sector is the measuring of the capacitance to ground. Though there are some measures currently use but their accuracy are rather low. In this paper, we introduced two new different methods for measuring the capacitance to ground of the networks. Fornon-grounding neutral system and neutral compensating system. And on such base the grounding fault resistance can be finally calculated. (5 pages) | 
    
| Author | Xiao-Li Niu | 
    
| Author_xml | – sequence: 1 surname: Xiao-Li Niu fullname: Xiao-Li Niu  | 
    
| BookMark | eNo1kM1KQzEQhQMqqLUrXyArF0I1__fGnRT_oOCmri9JOmmjbXJJUnwBH9x7bV3NwHznzMy5RKcxRUDompI7SoS-d_0DI0QxosUJmuqmJa3igjKh2DmalvJJCKFaKd3oC_Sz3ADOUMBkt8E3uM_G1eAAJ4_rMEoRb0MEvEsx1JRDXOMd1E1aFexT_kOc6Y0L1cRBVRNe57SPq8Hq0IwKb_bbOm4J5YAdzSPU75S_yhU682ZbYHqsE_Tx_LScv84W7y9v88fFLFAi60wbq4VstWaNagxnnFFriZTSSWr0SnHLiJFcKxCWUWGFBTeQ3hNH2-FdPkG3B98AtXMpesgwnFM6Sroxus713X90_BedJWVU | 
    
| ContentType | Conference Proceeding | 
    
| DBID | 8ET | 
    
| DOI | 10.1049/cp:20062094 | 
    
| DatabaseName | IET Conference Publications by volume | 
    
| DatabaseTitleList | |
| DeliveryMethod | fulltext_linktorsrc | 
    
| Discipline | Engineering | 
    
| ExternalDocumentID | 10_1049_cp_20062094 | 
    
| GroupedDBID | 6IE 6IK 8ET AAJGR ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK OCL RIE  | 
    
| ID | FETCH-LOGICAL-i105t-9ab9458992767a32321bb0555c51a9d63b20a5396e4b214b4bec767ff0c186973 | 
    
| ISBN | 9780863412462 0863412467  | 
    
| IngestDate | Wed Apr 27 04:28:09 EDT 2022 | 
    
| IsPeerReviewed | false | 
    
| IsScholarly | false | 
    
| Keywords | fault management distribution networks neutral compensating system earthing computerised monitoring distribution network electrical faults grounding fault resistance capacitance measurement neutral noneffectively earthed system Fornon-grounding neutral system online monitoring  | 
    
| Language | English | 
    
| LinkModel | OpenURL | 
    
| MeetingName | 7th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2006), 30 Oct.-2 Nov. 2006, Hong Kong, China | 
    
| MergedId | FETCHMERGED-LOGICAL-i105t-9ab9458992767a32321bb0555c51a9d63b20a5396e4b214b4bec767ff0c186973 | 
    
| ParticipantIDs | iet_conferences_10_1049_cp_20062094 | 
    
| PublicationCentury | 2000 | 
    
| PublicationDate | 20060000 | 
    
| PublicationDateYYYYMMDD | 2006-01-01 | 
    
| PublicationDate_xml | – year: 2006 text: 20060000  | 
    
| PublicationDecade | 2000 | 
    
| PublicationPlace | Stevenage | 
    
| PublicationPlace_xml | – name: Stevenage | 
    
| PublicationTitle | 7th IET International Conference on Advances in Power System Control, Operation and Management (APSCOM 2006) | 
    
| PublicationYear | 2006 | 
    
| Publisher | IET | 
    
| Publisher_xml | – name: IET | 
    
| SSID | ssj0001966979 | 
    
| Score | 1.3571767 | 
    
| Snippet | Measuring of the single phase grounding fault resistance is a main subject in the fault management of the neutral non-effectively earthed system. And for the... | 
    
| SourceID | iet | 
    
| SourceType | Publisher | 
    
| StartPage | 241 | 
    
| SubjectTerms | Computerised instrumentation Distribution networks Impedance and admittance measurement Power system protection  | 
    
| Title | The research & practice of the on line monitoring methods for the capacitance to ground & grounding fault resistance of the networks | 
    
| URI | http://digital-library.theiet.org/content/conferences/10.1049/cp_20062094 | 
    
| hasFullText | 1 | 
    
| inHoldings | 1 | 
    
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnZ1La9wwEIDFJqf01DQpfSNIySW49UO2ot5CSElKHgvdwN4WSZaIIbWXRnvJOT-8o5e92SylzcUYI8ZG31iekeeB0Gee5XWq4f3WUpUJYYVOhKQ0oZrkkmValbWr9nlZnV6TH9NyOhrdL2eXGPFF3q_NK3kOVbgGXG2W7H-Q7YXCBTgHvnAEwnBcMX7XfmeouTk4O5ms7OoNOXz2R8CR_8fvol7HtiNaqFFuh9kYdTvFV3MV9MBHXcSAGGt9Ho1_Hl9d2MKDVb9pMChYKBV04xQoJlzFsAOQ52zYX27ZcHF-vl_1XR_bKOFTLRvj0hbACLYpJm3thPlTF-bJF7fG3slauu0gvvUB7L1PMG14l5w3oNuLv25lwIw98m7B2ypsc-ywXIcV1tfJerLyg6cDuOQcCFnReep7J68U03a_3AmbyfksjtpAG3Arn_k37M6BF8gocwVDw0PQUK6pf6iQ7Qnivsr5tygObJRGmSUbZfIS7Q7k8bjXl200Uu0r9GKp8OQOegB4OMLD-ziiw53GMLe4a7FFhwd0OKDDgM4NWUKHTYc9LxDVg8MOHB7AReER3C66_n4yOT5NQj-OpAEr3CSMC0ZKcNBzWlFegC2eCWELxsky46yuCpGnvCxYpYjIMyIIrA8wUutU2sZntHiNNtuuVW8QlrLQvJYqZzQn9SEXFRVSpIeCVVoxxd6iPZjFmezn7W62Bt27fxr1Hm0NyvYBbZrfC_URLEkjPjnofwAwO3NU | 
    
| linkProvider | IEEE | 
    
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=7th+IET+International+Conference+on+Advances+in+Power+System+Control%2C+Operation+and+Management+%28APSCOM+2006%29&rft.atitle=The+research+%26+practice+of+the+on+line+monitoring+methods+for+the+capacitance+to+ground+%26+grounding+fault+resistance+of+the+networks&rft.au=Xiao-Li+Niu&rft.date=2006-01-01&rft.pub=IET&rft.isbn=9780863412462&rft.spage=241&rft_id=info:doi/10.1049%2Fcp%3A20062094&rft.externalDocID=10_1049_cp_20062094 | 
    
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780863412462/lc.gif&client=summon&freeimage=true | 
    
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780863412462/mc.gif&client=summon&freeimage=true | 
    
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780863412462/sc.gif&client=summon&freeimage=true |