Transient noise in a CCD camera sensor induced by neutron and gamma irradiation
This paper presents the transient radiation sensitivity for a 512/spl times/512 CCD image sensor irradiated with both 14 MeV neutrons and gamma rays. We have investigated the different image degradations with a pulsed neutron source as a function of angle of incidence and CCD camera parameters. A co...
Saved in:
| Published in | 2001 6th European Conference on Radiation and Its Effects on Components and Systems pp. 186 - 191 |
|---|---|
| Main Authors | , , , |
| Format | Conference Proceeding |
| Language | English |
| Published |
IEEE
2001
|
| Subjects | |
| Online Access | Get full text |
| ISBN | 9780780373136 0780373138 |
| DOI | 10.1109/RADECS.2001.1159278 |
Cover
| Abstract | This paper presents the transient radiation sensitivity for a 512/spl times/512 CCD image sensor irradiated with both 14 MeV neutrons and gamma rays. We have investigated the different image degradations with a pulsed neutron source as a function of angle of incidence and CCD camera parameters. A complete analysis has been achieved for fluences from 10/sup 4/ to 10/sup 7/ n/cm/sup 2/ including neutron induced noise spectra. We have found a linear dependence of the number of bright and saturated pixels with fluence. The number and size of pixel clusters increase with fluence, particularly for grazing angle. In a second time, we have investigated gamma effects which only increase the background noise of the CCD. |
|---|---|
| AbstractList | This paper presents the transient radiation sensitivity for a 512/spl times/512 CCD image sensor irradiated with both 14 MeV neutrons and gamma rays. We have investigated the different image degradations with a pulsed neutron source as a function of angle of incidence and CCD camera parameters. A complete analysis has been achieved for fluences from 10/sup 4/ to 10/sup 7/ n/cm/sup 2/ including neutron induced noise spectra. We have found a linear dependence of the number of bright and saturated pixels with fluence. The number and size of pixel clusters increase with fluence, particularly for grazing angle. In a second time, we have investigated gamma effects which only increase the background noise of the CCD. |
| Author | Baggio, J. Musseau, O. D'hose, C. Martinez, M. |
| Author_xml | – sequence: 1 givenname: J. surname: Baggio fullname: Baggio, J. organization: CEA/DIF BP 12, Bruyeres-le-Chatel, France – sequence: 2 givenname: C. surname: D'hose fullname: D'hose, C. organization: CEA/DIF BP 12, Bruyeres-le-Chatel, France – sequence: 3 givenname: M. surname: Martinez fullname: Martinez, M. organization: CEA/DIF BP 12, Bruyeres-le-Chatel, France – sequence: 4 givenname: O. surname: Musseau fullname: Musseau, O. organization: CEA/DIF BP 12, Bruyeres-le-Chatel, France |
| BookMark | eNotT9FKAzEQDKig1vuCvuQHribZS-7yWK7VCoWC1ueyd9mTiJeT5PrQvzdgh4FlhmHYeWS3YQrE2FKKlZTCPr-vN9v2Y6WEkNnQVtXNDSts3YhMqEGCuWdFSt8io9JV1ZgHdjhGDMlTmHmYfCLuA0fethve40gReaKQpphtd-7J8e7CA53nOOVYcPwLxxG5jxGdx9lP4YndDfiTqLjeBft82R7bXbk_vL61633ppdBzaaCq8p9EdmhAoUQE3ake3ADODKrOWjkQFq0WsrJWg-mH3nZOA7i-MbBgy_9eT0Sn3-hHjJfTdTb8AZyBTzg |
| ContentType | Conference Proceeding |
| DBID | 6IE 6IL CBEJK RIE RIL |
| DOI | 10.1109/RADECS.2001.1159278 |
| DatabaseName | IEEE Electronic Library (IEL) Conference Proceedings IEEE Xplore POP ALL IEEE Xplore All Conference Proceedings IEEE Electronic Library (IEL) IEEE Proceedings Order Plans (POP All) 1998-Present |
| DatabaseTitleList | |
| Database_xml | – sequence: 1 dbid: RIE name: IEEE Electronic Library (IEL) url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
| DeliveryMethod | fulltext_linktorsrc |
| EndPage | 191 |
| ExternalDocumentID | 1159278 |
| GroupedDBID | 6IE 6IK 6IL AAJGR AAVQY AAWTH ALMA_UNASSIGNED_HOLDINGS BEFXN BFFAM BGNUA BKEBE BPEOZ CBEJK OCL RIE RIL |
| ID | FETCH-LOGICAL-i105t-6344001ee9f832a1aa35b2c3df3d6f27aa32d309a9501499536cfc9bd533dc863 |
| IEDL.DBID | RIE |
| ISBN | 9780780373136 0780373138 |
| IngestDate | Tue Aug 26 17:16:24 EDT 2025 |
| IsPeerReviewed | false |
| IsScholarly | false |
| Language | English |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-i105t-6344001ee9f832a1aa35b2c3df3d6f27aa32d309a9501499536cfc9bd533dc863 |
| PageCount | 6 |
| ParticipantIDs | ieee_primary_1159278 |
| PublicationCentury | 2000 |
| PublicationDate | 20010000 |
| PublicationDateYYYYMMDD | 2001-01-01 |
| PublicationDate_xml | – year: 2001 text: 20010000 |
| PublicationDecade | 2000 |
| PublicationTitle | 2001 6th European Conference on Radiation and Its Effects on Components and Systems |
| PublicationTitleAbbrev | RADECS |
| PublicationYear | 2001 |
| Publisher | IEEE |
| Publisher_xml | – name: IEEE |
| SSID | ssj0000454486 |
| Score | 1.3035681 |
| Snippet | This paper presents the transient radiation sensitivity for a 512/spl times/512 CCD image sensor irradiated with both 14 MeV neutrons and gamma rays. We have... |
| SourceID | ieee |
| SourceType | Publisher |
| StartPage | 186 |
| SubjectTerms | Charge coupled devices Charge-coupled image sensors Degradation Gamma ray detectors Laser fusion Laser noise Neutrons Optical imaging Protection X-ray lasers |
| Title | Transient noise in a CCD camera sensor induced by neutron and gamma irradiation |
| URI | https://ieeexplore.ieee.org/document/1159278 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3NS8MwFA_bTp5UNvGbHDzarmnaJjlXxxCmog52G2k-pMg66dqD_vXmtd1E8SDkkIQSkrw-3vcvCF3JmCtiwf8Vs8CLVOJ4LmbEs8YqQDenkYKI7uw-mc6ju0W86KHrXS2MMaZJPjM-dJtYvl6rGlxlY6e9iJDxPuoznrS1Wjt_CkDJRTxpLHMeUEYJ5R3AznacdKhDJBDjJ3fO9BnsQ-J3y_54X6URL5N9NNturM0qefPrKvPV5y_Mxv_u_ACNvgv58ONORB2inimG6KGRT1AHiYt1vjE4L7DEaXqDlQQXFd4403Zdumnt6K5x9oELU4PLHMtC41e5WkmclyWgGgBZR2g-uX1Jp173roKXO22q8hIaOc4lxgjr-FkSKWmchYpqS3ViQ-bGoaaBkAKCjgICvMoqkWmnGmrFE3qEBsW6MMcIO32JC27df0DdooJI674mJjQZs9xqdoKGcBnL9xY6Y9ndw-nf02dor03xgnaOBlVZmwsn86vssiH2F3lsppk |
| linkProvider | IEEE |
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3LT8MgGCdzHvSkZjO-5eDRdqPQFs7VZeo2jW7JbgvlYRqz1nTtQf96oe1mNB5MOABpCPD1y_f-AcAV96lA2vq__LDvEBEYnvND5GilhUU3x0TYiO54Egxn5H7uz1vgelMLo5Sqks-Ua7tVLF9morSusp7RXpgX0i2w7RNC_Lpaa-NRsWByhAaVbU77OMQI0wZiZz0OGtwh1Ge9Z3PS6MVaiMhtFv7xwkolYAZ7YLzeWp1X8uaWReyKz1-ojf_d-z7ofpfywaeNkDoALZV2wGMloWwlJEyzZKVgkkIOo-gGCm6dVHBljNssN9PSUF7C-AOmqrROc8hTCV_5cslhkucW18AStgtmg9tpNHSalxWcxOhThRNgYngXKcW04WiOOMd-7AksNZaB9kIz9iTuM85s2JHZEK_QgsXSKIdS0AAfgnaapeoIQKMxUUa1-ROwWZQhrs3XSHkqDjXVMjwGHXsZi_caPGPR3MPJ39OXYGc4HY8Wo7vJwynYrRO-bDsD7SIv1bnRAIr4oiL8F2jVqeY |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Abook&rft.genre=proceeding&rft.title=2001+6th+European+Conference+on+Radiation+and+Its+Effects+on+Components+and+Systems&rft.atitle=Transient+noise+in+a+CCD+camera+sensor+induced+by+neutron+and+gamma+irradiation&rft.au=Baggio%2C+J.&rft.au=D%27hose%2C+C.&rft.au=Martinez%2C+M.&rft.au=Musseau%2C+O.&rft.date=2001-01-01&rft.pub=IEEE&rft.isbn=9780780373136&rft.spage=186&rft.epage=191&rft_id=info:doi/10.1109%2FRADECS.2001.1159278&rft.externalDocID=1159278 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780780373136/lc.gif&client=summon&freeimage=true |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780780373136/mc.gif&client=summon&freeimage=true |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=9780780373136/sc.gif&client=summon&freeimage=true |