Possibilities of signal-averaged orthogonal and vector electrocardiography for locating and size evaluation of acute myocardial infarction with ST-elevation
The signal-averaged electrocardiography (SAECG) is known to be a useful tool for extraction and analysis of low-amplitude signal components. We found SAECG may be useful for precise location of the site of the myocardial necrosis and assessment of the severity of impaired left ventricular systolic f...
Saved in:
Published in | Anadolu kardiyoloji dergisi : AKD Vol. 7 Suppl 1; no. 1; p. 193 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
Turkey
KARE Publishing
01.07.2007
|
Subjects | |
Online Access | Get full text |
ISSN | 1302-8723 |
Cover
Abstract | The signal-averaged electrocardiography (SAECG) is known to be a useful tool for extraction and analysis of low-amplitude signal components. We found SAECG may be useful for precise location of the site of the myocardial necrosis and assessment of the severity of impaired left ventricular systolic function of patients with ST-elevation myocardial infarct (STEMI) in the acute phase.
High-resolution (1 MHz) ECG from 3 groups were collected: healthy controls (20), patients with anterior (17) and inferior STEMI (21). The three orthogonal leads X, Y, Z were synthesized from the 12 standard leads by known transformation. Synchronized averaging was carried out over hundred P-QRS-T intervals of each orthogonal lead. The resulting intervals of all subjects within a group were additionally averaged. The obtained X, Y and Z patterns, as well as the derived loops in the vectorcardiographic planes (VCG patterns) were studied for significant divergences.
The summarized analysis presenting the possibilities of QRS- and T-vector indicators for correct classification of patients with STEMI shows that the determined discriminators classify correctly 91.4% of the examined patients. The optimized set of QRS-vector indicators for discrimination between healthy controls and patients with inferior STEMI include angle alpha of the maximal vector in both the sagittal and the horizontal plane. These two indicators show as high predictive value as all QRS-vector indicators -82.9%. The optimized combination of QRS-vector indicators for discrimination between healthy controls and patients with anterior STEMI includes amplitude of the maximal vector in the frontal and sagittal planes, angle alpha of the maximal vector in the sagittal plane and the area of the loop in the frontal plane. This optimized combination has a common mean percentage of correctly classified patients of about 91.9%. The accuracy for infarct zone localization is improved with optimized combinations involving together QRS- and T-vector indicators. The achieved common mean percentages of correct classifications are 94.6% (healthy controls-anterior STEMI), 92.7% (healthy controls-inferior STEMI) and 97.4% (anterior STEMI-inferior STEMI). The set of all QRS-and T-vector indicators of patients with anterior STEMI regarding 2D-echocardiographic ejection fraction shows very high correlation coefficient, reaching about 0.99. In contrast, we did not find significantly high correlation in patients with inferior STEMI.
Both the signal-averaged orthogonal ECG and the synthesized on its basis VCG show markedly high sensitivity regarding location of ST-elevation myocardial infarct. The possibility for facilitated and fast performance of this examination in clinical conditions, including emergency, the lack of necessity of specially trained staff for carrying out the examination and interpretation of the results, as well as the very low prime cost, make this electrophysiological method very suitable for application in the routine clinical practice for qualitative and quantitative assessment of patients with acute coronary syndromes. |
---|---|
AbstractList | The signal-averaged electrocardiography (SAECG) is known to be a useful tool for extraction and analysis of low-amplitude signal components. We found SAECG may be useful for precise location of the site of the myocardial necrosis and assessment of the severity of impaired left ventricular systolic function of patients with ST-elevation myocardial infarct (STEMI) in the acute phase.OBJECTIVEThe signal-averaged electrocardiography (SAECG) is known to be a useful tool for extraction and analysis of low-amplitude signal components. We found SAECG may be useful for precise location of the site of the myocardial necrosis and assessment of the severity of impaired left ventricular systolic function of patients with ST-elevation myocardial infarct (STEMI) in the acute phase.High-resolution (1 MHz) ECG from 3 groups were collected: healthy controls (20), patients with anterior (17) and inferior STEMI (21). The three orthogonal leads X, Y, Z were synthesized from the 12 standard leads by known transformation. Synchronized averaging was carried out over hundred P-QRS-T intervals of each orthogonal lead. The resulting intervals of all subjects within a group were additionally averaged. The obtained X, Y and Z patterns, as well as the derived loops in the vectorcardiographic planes (VCG patterns) were studied for significant divergences.METHODSHigh-resolution (1 MHz) ECG from 3 groups were collected: healthy controls (20), patients with anterior (17) and inferior STEMI (21). The three orthogonal leads X, Y, Z were synthesized from the 12 standard leads by known transformation. Synchronized averaging was carried out over hundred P-QRS-T intervals of each orthogonal lead. The resulting intervals of all subjects within a group were additionally averaged. The obtained X, Y and Z patterns, as well as the derived loops in the vectorcardiographic planes (VCG patterns) were studied for significant divergences.The summarized analysis presenting the possibilities of QRS- and T-vector indicators for correct classification of patients with STEMI shows that the determined discriminators classify correctly 91.4% of the examined patients. The optimized set of QRS-vector indicators for discrimination between healthy controls and patients with inferior STEMI include angle alpha of the maximal vector in both the sagittal and the horizontal plane. These two indicators show as high predictive value as all QRS-vector indicators -82.9%. The optimized combination of QRS-vector indicators for discrimination between healthy controls and patients with anterior STEMI includes amplitude of the maximal vector in the frontal and sagittal planes, angle alpha of the maximal vector in the sagittal plane and the area of the loop in the frontal plane. This optimized combination has a common mean percentage of correctly classified patients of about 91.9%. The accuracy for infarct zone localization is improved with optimized combinations involving together QRS- and T-vector indicators. The achieved common mean percentages of correct classifications are 94.6% (healthy controls-anterior STEMI), 92.7% (healthy controls-inferior STEMI) and 97.4% (anterior STEMI-inferior STEMI). The set of all QRS-and T-vector indicators of patients with anterior STEMI regarding 2D-echocardiographic ejection fraction shows very high correlation coefficient, reaching about 0.99. In contrast, we did not find significantly high correlation in patients with inferior STEMI.RESULTSThe summarized analysis presenting the possibilities of QRS- and T-vector indicators for correct classification of patients with STEMI shows that the determined discriminators classify correctly 91.4% of the examined patients. The optimized set of QRS-vector indicators for discrimination between healthy controls and patients with inferior STEMI include angle alpha of the maximal vector in both the sagittal and the horizontal plane. These two indicators show as high predictive value as all QRS-vector indicators -82.9%. The optimized combination of QRS-vector indicators for discrimination between healthy controls and patients with anterior STEMI includes amplitude of the maximal vector in the frontal and sagittal planes, angle alpha of the maximal vector in the sagittal plane and the area of the loop in the frontal plane. This optimized combination has a common mean percentage of correctly classified patients of about 91.9%. The accuracy for infarct zone localization is improved with optimized combinations involving together QRS- and T-vector indicators. The achieved common mean percentages of correct classifications are 94.6% (healthy controls-anterior STEMI), 92.7% (healthy controls-inferior STEMI) and 97.4% (anterior STEMI-inferior STEMI). The set of all QRS-and T-vector indicators of patients with anterior STEMI regarding 2D-echocardiographic ejection fraction shows very high correlation coefficient, reaching about 0.99. In contrast, we did not find significantly high correlation in patients with inferior STEMI.Both the signal-averaged orthogonal ECG and the synthesized on its basis VCG show markedly high sensitivity regarding location of ST-elevation myocardial infarct. The possibility for facilitated and fast performance of this examination in clinical conditions, including emergency, the lack of necessity of specially trained staff for carrying out the examination and interpretation of the results, as well as the very low prime cost, make this electrophysiological method very suitable for application in the routine clinical practice for qualitative and quantitative assessment of patients with acute coronary syndromes.CONCLUSIONSBoth the signal-averaged orthogonal ECG and the synthesized on its basis VCG show markedly high sensitivity regarding location of ST-elevation myocardial infarct. The possibility for facilitated and fast performance of this examination in clinical conditions, including emergency, the lack of necessity of specially trained staff for carrying out the examination and interpretation of the results, as well as the very low prime cost, make this electrophysiological method very suitable for application in the routine clinical practice for qualitative and quantitative assessment of patients with acute coronary syndromes. The signal-averaged electrocardiography (SAECG) is known to be a useful tool for extraction and analysis of low-amplitude signal components. We found SAECG may be useful for precise location of the site of the myocardial necrosis and assessment of the severity of impaired left ventricular systolic function of patients with ST-elevation myocardial infarct (STEMI) in the acute phase. High-resolution (1 MHz) ECG from 3 groups were collected: healthy controls (20), patients with anterior (17) and inferior STEMI (21). The three orthogonal leads X, Y, Z were synthesized from the 12 standard leads by known transformation. Synchronized averaging was carried out over hundred P-QRS-T intervals of each orthogonal lead. The resulting intervals of all subjects within a group were additionally averaged. The obtained X, Y and Z patterns, as well as the derived loops in the vectorcardiographic planes (VCG patterns) were studied for significant divergences. The summarized analysis presenting the possibilities of QRS- and T-vector indicators for correct classification of patients with STEMI shows that the determined discriminators classify correctly 91.4% of the examined patients. The optimized set of QRS-vector indicators for discrimination between healthy controls and patients with inferior STEMI include angle alpha of the maximal vector in both the sagittal and the horizontal plane. These two indicators show as high predictive value as all QRS-vector indicators -82.9%. The optimized combination of QRS-vector indicators for discrimination between healthy controls and patients with anterior STEMI includes amplitude of the maximal vector in the frontal and sagittal planes, angle alpha of the maximal vector in the sagittal plane and the area of the loop in the frontal plane. This optimized combination has a common mean percentage of correctly classified patients of about 91.9%. The accuracy for infarct zone localization is improved with optimized combinations involving together QRS- and T-vector indicators. The achieved common mean percentages of correct classifications are 94.6% (healthy controls-anterior STEMI), 92.7% (healthy controls-inferior STEMI) and 97.4% (anterior STEMI-inferior STEMI). The set of all QRS-and T-vector indicators of patients with anterior STEMI regarding 2D-echocardiographic ejection fraction shows very high correlation coefficient, reaching about 0.99. In contrast, we did not find significantly high correlation in patients with inferior STEMI. Both the signal-averaged orthogonal ECG and the synthesized on its basis VCG show markedly high sensitivity regarding location of ST-elevation myocardial infarct. The possibility for facilitated and fast performance of this examination in clinical conditions, including emergency, the lack of necessity of specially trained staff for carrying out the examination and interpretation of the results, as well as the very low prime cost, make this electrophysiological method very suitable for application in the routine clinical practice for qualitative and quantitative assessment of patients with acute coronary syndromes. |
Audience | Academic |
Author | Matveev, Mikhail Naydenov, Stefan Donova, Temenuga Krasteva, Vessela |
Author_xml | – sequence: 1 givenname: Mikhail surname: Matveev fullname: Matveev, Mikhail email: mgm@clbme.bas.bg organization: Center of Biomedical Engineering, Bulgarian Academy of Sciences, Sofia, Bulgaria. mgm@clbme.bas.bg – sequence: 2 givenname: Vessela surname: Krasteva fullname: Krasteva, Vessela – sequence: 3 givenname: Stefan surname: Naydenov fullname: Naydenov, Stefan – sequence: 4 givenname: Temenuga surname: Donova fullname: Donova, Temenuga |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/17584723$$D View this record in MEDLINE/PubMed |
BookMark | eNptkc1q3DAURr1IaDJpXyEIAt05SJZseZZhaH4g0ELTtbmWrjwKsjWRZJfJs_Rhq8wki0LR4sLR-T4J7qo4mfyEJ8U547QqW1nxs2IV4zOltWyk-FScMVm3IvPz4s8PH6PtrbPJYiTekGiHCVwJCwYYUBMf0tYPPjMCkyYLquQDQZdn8AqCtn4IsNvuicncZZTsNBzcaF-R4AJuzsxPb-2g5oRk3B-TudNOBoI6XP-2aUt-PpW5ezkEPhenBlzEL-_zovh1--1pc18-fr972Nw8lkMlm1QaalRN2xolrJFKZtatUj3jqhIMGq2pEMJAXzWoK0RkvKLYi7VE3krNRMsviq_H3l3wLzPG1I02KnQOJvRz7CRt6rptWBavjuIADrv8dZ8CqDe5u2GNbEXFeZ2t6_9Y-WgcrcqrMTbzfwKX7-_P_Yi62wU7Qth3H2vifwGBJ5Ky |
ContentType | Journal Article |
Copyright | COPYRIGHT 2007 KARE Publishing |
Copyright_xml | – notice: COPYRIGHT 2007 KARE Publishing |
DBID | CGR CUY CVF ECM EIF NPM 7X8 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
DatabaseTitleList | MEDLINE - Academic MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
ExternalDocumentID | A167842335 17584723 |
Genre | Evaluation Studies Journal Article |
GeographicLocations | Bulgaria |
GeographicLocations_xml | – name: Bulgaria |
GroupedDBID | --- 23M 2WC 36B 53G 5GY 7X7 88E 8FI 8FJ 8G5 8R4 8R5 AAWTL ABUWG ADBBV AHMBA ALMA_UNASSIGNED_HOLDINGS AZQEC BAWUL BENPR BPHCQ BVXVI C1A CGR CUY CVF DIK DWQXO E3Z ECM EDSIH EIF EMB EMOBN F5P FYUFA GJB GNUQQ GUQSH GX1 IAO IHR INH INR ITC M1P M2O NPM OVT P2P PADUT PIMPY PQQKQ PROAC Q2X RNS SV3 7X8 |
ID | FETCH-LOGICAL-g276t-f0fc5085e7a9e071f98ccb13c241a6dd0444fab26ed2eee1320eb497e387d1483 |
ISSN | 1302-8723 |
IngestDate | Fri Jul 11 06:09:24 EDT 2025 Wed Mar 19 02:28:14 EDT 2025 Sat Mar 08 19:00:34 EST 2025 Mon Jul 21 05:53:45 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 1 |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-g276t-f0fc5085e7a9e071f98ccb13c241a6dd0444fab26ed2eee1320eb497e387d1483 |
Notes | ObjectType-Article-2 SourceType-Scholarly Journals-1 ObjectType-Undefined-1 ObjectType-Feature-3 content type line 23 |
PMID | 17584723 |
PQID | 70655861 |
PQPubID | 23479 |
ParticipantIDs | proquest_miscellaneous_70655861 gale_infotracmisc_A167842335 gale_infotracacademiconefile_A167842335 pubmed_primary_17584723 |
PublicationCentury | 2000 |
PublicationDate | 2007-Jul 20070701 |
PublicationDateYYYYMMDD | 2007-07-01 |
PublicationDate_xml | – month: 07 year: 2007 text: 2007-Jul |
PublicationDecade | 2000 |
PublicationPlace | Turkey |
PublicationPlace_xml | – name: Turkey |
PublicationTitle | Anadolu kardiyoloji dergisi : AKD |
PublicationTitleAlternate | Anadolu Kardiyol Derg |
PublicationYear | 2007 |
Publisher | KARE Publishing |
Publisher_xml | – name: KARE Publishing |
SSID | ssj0057674 |
Score | 1.7582196 |
Snippet | The signal-averaged electrocardiography (SAECG) is known to be a useful tool for extraction and analysis of low-amplitude signal components. We found SAECG may... |
SourceID | proquest gale pubmed |
SourceType | Aggregation Database Index Database |
StartPage | 193 |
SubjectTerms | Arrhythmias, Cardiac - complications Arrhythmias, Cardiac - diagnosis Arrhythmias, Cardiac - physiopathology Diagnosis Electrocardiogram Electrocardiography Heart attack Humans Methods Myocardial Infarction - complications Myocardial Infarction - diagnosis Myocardial Infarction - physiopathology Predictive Value of Tests Sensitivity and Specificity Severity of Illness Index |
Title | Possibilities of signal-averaged orthogonal and vector electrocardiography for locating and size evaluation of acute myocardial infarction with ST-elevation |
URI | https://www.ncbi.nlm.nih.gov/pubmed/17584723 https://www.proquest.com/docview/70655861 |
Volume | 7 Suppl 1 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
journalDatabaseRights | – providerCode: PRVBFR databaseName: Free Medical Journals issn: 1302-8723 databaseCode: DIK dateStart: 20010101 customDbUrl: isFulltext: true dateEnd: 99991231 titleUrlDefault: http://www.freemedicaljournals.com omitProxy: true ssIdentifier: ssj0057674 providerName: Flying Publisher – providerCode: PRVFQY databaseName: GFMER Free Medical Journals issn: 1302-8723 databaseCode: GX1 dateStart: 0 customDbUrl: isFulltext: true dateEnd: 99991231 titleUrlDefault: http://www.gfmer.ch/Medical_journals/Free_medical.php omitProxy: true ssIdentifier: ssj0057674 providerName: Geneva Foundation for Medical Education and Research |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9MwELa6e0Bc0PIuu4APSByqoCbO81jx0IpVV0h0UW-RYzul7NKgNqnU_QH8Cn4sM-M0SbsrBFyiKo4dNfNlPJ5885mxV7lIIKjVwlEqkA6svzIniYx0jB8PPalFKIhVOT4PTy_8j9Ng2uv97LCWqjJ7o65vrSv5H6vCObArVsn-g2WbQeEE_Ab7whEsDMe_svGnYlWzW-dWOxbZGPLKkfBPwE_oAX6UKWaU7MME-ZpS9IN66xtFVFSrWE1sQ5zXym3R4mp-bTpa4MQXUEgq-L6xPUmtI4f3hJopn_t54mC5emvsRqUZhaOqwSX224C7_TYfaLPEnAmlJEZnDe94LMu1gedAjP7Lrx0GyNlSAiLXFOx-QcXzq2ZGOZcbcJ_Fuqat5S3i3xW46SuBEvOg1UzupDmihhJbFw2MkAPSZOY6HluQS7dFy1uXHt1ArnXPrt2NcU9he-TCjA1hpQgO2AH4PywZnzZEoQDljmjZXt_o5uS9tySh0GRyxO7Vawo-sgC5z3pm8YDdGdesiYfs1w5OeJHzPZzwFiccbM8tTvgtOOGAE77FCV2LOOEtTnB0wglvccJbnHDECe_i5BG7-PB-8vbUqXflcGZeFJZOPswVRPWBiWRiIEDNk1ipzBUKYkEZao0ChLnMvNBozxiDJfom88EBiDjSsPgWj9nholiYp4z7MLsERri59j3fhDKORBj6bqyHbpxknumz1_ikU3wjy6VUsi4Zgd6oWpa2huuzk50rwUeqneaXW1ul2ITEwoUpqlWKX_mDOHT77Ik1YfrDqrykEFdD5OaJZ38e-pjdbeF6wg7LZWWeQ5xaZi8IRr8B28ejGQ |
linkProvider | Geneva Foundation for Medical Education and Research |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Possibilities+of+signal-averaged+orthogonal+and+vector+electrocardiography+for+locating+and+size+evaluation+of+acute+myocardial+infarction+with+ST-elevation&rft.jtitle=Anadolu+kardiyoloji+dergisi+%3A+AKD&rft.au=Matveev%2C+Mikhail&rft.au=Krasteva%2C+Vessela&rft.au=Naydenov%2C+Stefan&rft.au=Donova%2C+Temenuga&rft.date=2007-07-01&rft.pub=KARE+Publishing&rft.issn=1302-8723&rft.volume=7&rft.issue=1&rft.spage=193&rft.externalDocID=A167842335 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1302-8723&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1302-8723&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1302-8723&client=summon |