Load Frequency Control for Power System using Generalized Extended State Observer
This study investigates load frequency control based generalized extended state observer (GESO) for interconnected power systems subject to multi-kind of the power plant. First, the mathematical model of the interconnected power system is proposed based on the dynamic model of thermal power plant wi...
        Saved in:
      
    
          | Published in | Journal of Advanced Engineering and Computation Vol. 5; no. 1; p. 1 | 
|---|---|
| Main Authors | , , | 
| Format | Journal Article | 
| Language | English | 
| Published | 
          
        31.03.2021
     | 
| Online Access | Get full text | 
| ISSN | 1859-2244 2588-123X 2588-123X  | 
| DOI | 10.25073/jaec.202151.307 | 
Cover
| Abstract | This study investigates load frequency control based generalized extended state observer (GESO) for interconnected power systems subject to multi-kind of the power plant. First, the mathematical model of the interconnected power system is proposed based on the dynamic model of thermal power plant with reheat turbine and hydropower plant. Second, the GESO is designed to estimate the system states and disturbances. In addition, the problem of unmeasurable system states in the interconnected power network due to lack of sensor has been solved by using the proposed load frequency control based GESO. The numerical experiments are carried out by using MATLAB/ SIMULINK simulation. The simulation results point out that the proposed control approach has the capacity to handle the uncertainties and disturbances in the interconnected power system with better transient performances in comparison with the existing control approach. The relevant dynamic models have already been used for the simulation of the physical constraints of the governor dead band (GDB) and generation rate constraint (GRC) effect in the power plants. It is evident that the robustness of the suggested controller in terms of stability and effectiveness of the system. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium provided the original work is properly cited. | 
    
|---|---|
| AbstractList | This study investigates load frequency control based generalized extended state observer (GESO) for interconnected power systems subject to multi-kind of the power plant. First, the mathematical model of the interconnected power system is proposed based on the dynamic model of thermal power plant with reheat turbine and hydropower plant. Second, the GESO is designed to estimate the system states and disturbances. In addition, the problem of unmeasurable system states in the interconnected power network due to lack of sensor has been solved by using the proposed load frequency control based GESO. The numerical experiments are carried out by using MATLAB/ SIMULINK simulation. The simulation results point out that the proposed control approach has the capacity to handle the uncertainties and disturbances in the interconnected power system with better transient performances in comparison with the existing control approach. The relevant dynamic models have already been used for the simulation of the physical constraints of the governor dead band (GDB) and generation rate constraint (GRC) effect in the power plants. It is evident that the robustness of the suggested controller in terms of stability and effectiveness of the system. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium provided the original work is properly cited. | 
    
| Author | Huynh, Van Van Tran, Anh-Tuan Tran, Phong Thanh  | 
    
| Author_xml | – sequence: 1 givenname: Anh-Tuan surname: Tran fullname: Tran, Anh-Tuan – sequence: 2 givenname: Phong Thanh surname: Tran fullname: Tran, Phong Thanh – sequence: 3 givenname: Van Van surname: Huynh fullname: Huynh, Van Van  | 
    
| BookMark | eNqF0MFPwjAUx_HGYCIid4_9B4bt27q2R0MASZaggYO3peveDGS02A5x_vWiePf03uX7O3xuycB5h4TcczYBwWT6sDNoJ8CACz5JmbwiQxBKJRzS1wEZciV0ApBlN2Qc444xBppznYsheSm8qek84PsRne3p1Lsu-JY2PtBnf8JA133scE-Pceve6AIdBtNuv7Cms88OXX1-1p3pkK6qiOEDwx25bkwbcfx3R2Qzn22mT0mxWiynj0ViVSoTCcxapTBD26hUVzJXlUDM80qi4ACysVogt4DaKI0KweS8VkJqpiRkLB0Rfpk9uoPpT6Zty0PY7k3oS87KX5XyR6W8qJRnlXPDLo0NPsaAzf_JN_Q9Z2Y | 
    
| ContentType | Journal Article | 
    
| DBID | AAYXX CITATION ADTOC UNPAY  | 
    
| DOI | 10.25073/jaec.202151.307 | 
    
| DatabaseName | CrossRef Unpaywall for CDI: Periodical Content Unpaywall  | 
    
| DatabaseTitle | CrossRef | 
    
| DatabaseTitleList | CrossRef | 
    
| Database_xml | – sequence: 1 dbid: UNPAY name: Unpaywall url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/ sourceTypes: Open Access Repository  | 
    
| DeliveryMethod | fulltext_linktorsrc | 
    
| EISSN | 2588-123X | 
    
| ExternalDocumentID | 10.25073/jaec.202151.307 10_25073_jaec_202151_307  | 
    
| GroupedDBID | AAYXX ALMA_UNASSIGNED_HOLDINGS CITATION GROUPED_DOAJ ADTOC M~E UNPAY  | 
    
| ID | FETCH-LOGICAL-c837-720cc88e4ecf839b768b5ee66b7e51227fc95e1c2e9a89e8e2a61d85790872403 | 
    
| IEDL.DBID | UNPAY | 
    
| ISSN | 1859-2244 2588-123X  | 
    
| IngestDate | Tue Aug 19 19:41:19 EDT 2025 Tue Jul 01 03:57:08 EDT 2025  | 
    
| IsDoiOpenAccess | true | 
    
| IsOpenAccess | true | 
    
| IsPeerReviewed | true | 
    
| IsScholarly | true | 
    
| Issue | 1 | 
    
| Language | English | 
    
| License | http://creativecommons.org/licenses/by/4.0 cc-by  | 
    
| LinkModel | DirectLink | 
    
| MergedId | FETCHMERGED-LOGICAL-c837-720cc88e4ecf839b768b5ee66b7e51227fc95e1c2e9a89e8e2a61d85790872403 | 
    
| OpenAccessLink | https://proxy.k.utb.cz/login?url=https://jaec.vn/index.php/JAEC/article/download/307/148 | 
    
| ParticipantIDs | unpaywall_primary_10_25073_jaec_202151_307 crossref_primary_10_25073_jaec_202151_307  | 
    
| ProviderPackageCode | CITATION AAYXX  | 
    
| PublicationCentury | 2000 | 
    
| PublicationDate | 2021-03-31 | 
    
| PublicationDateYYYYMMDD | 2021-03-31 | 
    
| PublicationDate_xml | – month: 03 year: 2021 text: 2021-03-31 day: 31  | 
    
| PublicationDecade | 2020 | 
    
| PublicationTitle | Journal of Advanced Engineering and Computation | 
    
| PublicationYear | 2021 | 
    
| SSID | ssj0002911965 ssib059950757  | 
    
| Score | 2.141901 | 
    
| Snippet | This study investigates load frequency control based generalized extended state observer (GESO) for interconnected power systems subject to multi-kind of the... | 
    
| SourceID | unpaywall crossref  | 
    
| SourceType | Open Access Repository Index Database  | 
    
| StartPage | 1 | 
    
| Title | Load Frequency Control for Power System using Generalized Extended State Observer | 
    
| URI | https://jaec.vn/index.php/JAEC/article/download/307/148 | 
    
| UnpaywallVersion | publishedVersion | 
    
| Volume | 5 | 
    
| hasFullText | 1 | 
    
| inHoldings | 1 | 
    
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVHPJ databaseName: ROAD: Directory of Open Access Scholarly Resources customDbUrl: eissn: 2588-123X dateEnd: 99991231 omitProxy: true ssIdentifier: ssib059950757 issn: 1859-2244 databaseCode: M~E dateStart: 20140101 isFulltext: true titleUrlDefault: https://road.issn.org providerName: ISSN International Centre  | 
    
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1NS8NAEF20PXjyAxUrWvbgRSFJm2a_jqWklGJrhRbiKWw2E1FLWkqrtAd_u7vZVIoX0fuwLPOWzJvdyXsI3UipqAKROZnufpyAB-CIjKcOyWSTKz_IaOFDNhjS3iToRyQqry7MvzCvEpT7nnuFVqARiPD67bDjlWn0UqMgP5Opp4-mp5n8PqpSokl4BVUnw1H7yVjJEY29_h5H9lFSl3jWssv6RX1zW8Y6dqcIHazyuVx_yOl0p7J0j1C03ZMdKHlzV8vEVZsfco3_2PQxOizZJm7bkBO0B_kperzXUbi7sEPUa9yx0-pY01c8MqZp2MqYYzMT_4xLYeqXDaQ4LK_MccFR8UNi7nRhcYbG3XDc6Tmls4KjDCTMbyjFOQSgNEQi0S1HQgAoTRhoAuCzTAkCTeWDkFwAB1_SZsoJEw3OjIDfOarksxwuEA6oZEwo4UtlhHqENHY-AMX7Y0AaQQ3dbjMdz61-Rqz7jgKV2OQttqjEOjc1dPcNxa_Bl38JvkKV5WIF15o_LJM62h98hvXyxHwBrgHHoA | 
    
| linkProvider | Unpaywall | 
    
| linkToUnpaywall | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1NS8NAEF20PXjyAxVbVPbgRSFJm-7nsZSWUrRWaCGewmYzEbWkpbRK--vdzaZSvIjeh2WZt2Te7E7eQ-hGKc00yMzLTPfjEUHAk5lIPZqpptAhyVjhQ_YwZP0JGUQ0Kq8u7L8wbwq0_5EHhVagFYgIBu1uJyjTGKRWQX6m0sAczcAw-X1UZdSQ8AqqToaj9rO1kqMGe_M9jtyjpCnxvOWWDYv65resdexOETpY5XO1_lTT6U5l6R2haLsnN1Dy7q-Wia83P-Qa_7HpY3RYsk3cdiEnaA_yU_R0b6Jwb-GGqNe446bVsaGveGRN07CTMcd2Jv4Fl8LUrxtIcbe8MscFR8WPib3ThcUZGve6407fK50VPG0h4WFDayGAgDYQycS0HAkFYCzhYAhAyDMtKTR1CFIJCQJCxZqpoFw2BLcCfueoks9yuECYMMW51DJU2gr1SGXtfACK90dCG6SGbreZjudOPyM2fUeBSmzzFjtUYpObGrr7huLX4Ppfgi9RZblYwZXhD8vkujwrXwTbxm8 | 
    
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Load+Frequency+Control+for+Power+System+using+Generalized+Extended+State+Observer&rft.jtitle=Journal+of+Advanced+Engineering+and+Computation&rft.au=Tran%2C+Anh-Tuan&rft.au=Tran%2C+Phong+Thanh&rft.au=Huynh%2C+Van+Van&rft.date=2021-03-31&rft.issn=1859-2244&rft.eissn=2588-123X&rft.volume=5&rft.issue=1&rft.spage=1&rft_id=info:doi/10.25073%2Fjaec.202151.307&rft.externalDBID=n%2Fa&rft.externalDocID=10_25073_jaec_202151_307 | 
    
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1859-2244&client=summon | 
    
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1859-2244&client=summon | 
    
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1859-2244&client=summon |