Recommended test methods and pass/fail criteria for a respirator fit capability test of half-mask air-purifying respirators
This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying particulate respirators. Using a 25-subject test panel, benchmark RFC data were collected for 101 National Institute for Occupational Safety and He...
Saved in:
Published in | Journal of occupational and environmental hygiene Vol. 14; no. 6; pp. 473 - 481 |
---|---|
Main Authors | , , , , |
Format | Journal Article |
Language | English |
Published |
England
Taylor & Francis
01.06.2017
|
Subjects | |
Online Access | Get full text |
ISSN | 1545-9624 1545-9632 |
DOI | 10.1080/15459624.2017.1296233 |
Cover
Abstract | This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying particulate respirators. Using a 25-subject test panel, benchmark RFC data were collected for 101 National Institute for Occupational Safety and Health-certified respirator models. These models were further grouped into 61 one-, two-, or three-size families. Fit testing was done using a PortaCount® Plus with N95-Companion accessory and an Occupational Safety and Health Administration-accepted quantitative fit test protocol. Three repeated tests (donnings) per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of the 25-subject panel achieving acceptable fit) was determined for each model using five different alternative criteria for determining acceptable fit.
When the 101 models are evaluated individually (i.e., not grouped by families), the percentages of models capable of fitting >75% (19/25 subjects) of the panel were 29% and 32% for subjects achieving a fit factor ≥100 for at least one of the first two donnings and at least one of three donnings, respectively. When the models are evaluated grouped into families and using >75% of panel subjects achieving a fit factor ≥100 for at least one of two donnings as the PPR pass/fail criterion, 48% of all models can pass. When >50% (13/25 subjects) of panel subjects was the PPR criterion, the percentage of passing models increased to 70%.
Testing respirators grouped into families and evaluating the first two donnings for each of two respirator sizes provided the best balance between meeting end user expectations and creating a performance bar for manufacturers. Specifying the test criterion for a subject obtaining acceptable fit as achieving a fit factor ≥100 on at least one out of the two donnings is reasonable because a majority of existing respirator families can achieve an PPR of >50% using this criterion. The different test criteria can be considered by standards development organizations when developing standards. |
---|---|
AbstractList | This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying particulate respirators. Using a 25-subject test panel, benchmark RFC data were collected for 101 National Institute for Occupational Safety and Health-certified respirator models. These models were further grouped into 61 one-, two-, or three-size families. Fit testing was done using a PortaCount® Plus with N95-Companion accessory and an Occupational Safety and Health Administration-accepted quantitative fit test protocol. Three repeated tests (donnings) per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of the 25-subject panel achieving acceptable fit) was determined for each model using five different alternative criteria for determining acceptable fit.
When the 101 models are evaluated individually (i.e., not grouped by families), the percentages of models capable of fitting >75% (19/25 subjects) of the panel were 29% and 32% for subjects achieving a fit factor ≥100 for at least one of the first two donnings and at least one of three donnings, respectively. When the models are evaluated grouped into families and using >75% of panel subjects achieving a fit factor ≥100 for at least one of two donnings as the PPR pass/fail criterion, 48% of all models can pass. When >50% (13/25 subjects) of panel subjects was the PPR criterion, the percentage of passing models increased to 70%.
Testing respirators grouped into families and evaluating the first two donnings for each of two respirator sizes provided the best balance between meeting end user expectations and creating a performance bar for manufacturers. Specifying the test criterion for a subject obtaining acceptable fit as achieving a fit factor ≥100 on at least one out of the two donnings is reasonable because a majority of existing respirator families can achieve an PPR of >50% using this criterion. The different test criteria can be considered by standards development organizations when developing standards. This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying particulate respirators. Using a 25-subject test panel, benchmark RFC data were collected for 101 National Institute for Occupational Safety and Health-certified respirator models. These models were further grouped into 61 one-, two-, or three-size families. Fit testing was done using a PortaCount® Plus with N95-Companion accessory and an Occupational Safety and Health Administration-accepted quantitative fit test protocol. Three repeated tests (donnings) per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of the 25-subject panel achieving acceptable fit) was determined for each model using five different alternative criteria for determining acceptable fit. When the 101 models are evaluated individually (i.e., not grouped by families), the percentages of models capable of fitting >75% (19/25 subjects) of the panel were 29% and 32% for subjects achieving a fit factor ≥100 for at least one of the first two donnings and at least one of three donnings, respectively. When the models are evaluated grouped into families and using >75% of panel subjects achieving a fit factor ≥100 for at least one of two donnings as the PPR pass/fail criterion, 48% of all models can pass. When >50% (13/25 subjects) of panel subjects was the PPR criterion, the percentage of passing models increased to 70%. Testing respirators grouped into families and evaluating the first two donnings for each of two respirator sizes provided the best balance between meeting end user expectations and creating a performance bar for manufacturers. Specifying the test criterion for a subject obtaining acceptable fit as achieving a fit factor ≥100 on at least one out of the two donnings is reasonable because a majority of existing respirator families can achieve an PPR of >50% using this criterion. The different test criteria can be considered by standards development organizations when developing standards. This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying particulate respirators. Using a 25-subject test panel, benchmark RFC data were collected for 101 National Institute for Occupational Safety and Health-certified respirator models. These models were further grouped into 61 one-, two-, or three-size families. Fit testing was done using a PortaCount ® Plus with N95-Companion accessory and an Occupational Safety and Health Administration-accepted quantitative fit test protocol. Three repeated tests (donnings) per subject/respirator model combination were performed. The panel passing rate (PPR) (number or percentage of the 25-subject panel achieving acceptable fit) was determined for each model using five different alternative criteria for determining acceptable fit. When the 101 models are evaluated individually (i.e., not grouped by families), the percentages of models capable of fitting >75% (19/25 subjects) of the panel were 29% and 32% for subjects achieving a fit factor ≥100 for at least one of the first two donnings and at least one of three donnings, respectively. When the models are evaluated grouped into families and using >75% of panel subjects achieving a fit factor ≥100 for at least one of two donnings as the PPR pass/fail criterion, 48% of all models can pass. When >50% (13/25 subjects) of panel subjects was the PPR criterion, the percentage of passing models increased to 70%. Testing respirators grouped into families and evaluating the first two donnings for each of two respirator sizes provided the best balance between meeting end user expectations and creating a performance bar for manufacturers. Specifying the test criterion for a subject obtaining acceptable fit as achieving a fit factor ≥100 on at least one out of the two donnings is reasonable because a majority of existing respirator families can achieve an PPR of >50% using this criterion. The different test criteria can be considered by standards development organizations when developing standards. |
Author | Shaffer, Ronald Lei, Zhipeng Niezgoda, George Zhuang, Ziqing Bergman, Michael |
Author_xml | – sequence: 1 givenname: Ziqing surname: Zhuang fullname: Zhuang, Ziqing email: zaz3@cdc.gov organization: National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory – sequence: 2 givenname: Michael surname: Bergman fullname: Bergman, Michael organization: National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory – sequence: 3 givenname: Zhipeng surname: Lei fullname: Lei, Zhipeng organization: National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory – sequence: 4 givenname: George surname: Niezgoda fullname: Niezgoda, George organization: National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory – sequence: 5 givenname: Ronald surname: Shaffer fullname: Shaffer, Ronald organization: National Institute for Occupational Safety and Health, National Personal Protective Technology Laboratory |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/28278067$$D View this record in MEDLINE/PubMed |
BookMark | eNqFkdtq3DAQhkVJaU59hAa9gDc62JZNoSSEniBQCMm1GMtSdhpbMpKSsPTla7PZkPYiudKMNN8npP-Q7PngLSGfOFtx1rBTXpVVW4tyJRhXKy7mWsp35GDZL9pair3nWpT75DCl34yJmsv6A9kXjVANq9UB-XNlTRhH63vb02xTpqPN69AnCr6nE6R06gAHaiJmGxGoC5ECjTZNGCHPjcNMDUzQ4YB5s3UER9cwuGKEdEcBYzHdR3Qb9LcvyHRM3jsYkv34tB6Rm29fry9-FJe_vv-8OL8sTNWIXDR1Z2TtwJZGKWecKdtKdqKSJbC6MQpc33K2NIIDzE_nquvKzrSqN0xYkEfky9Y73Xej7Y31OcKgp4gjxI0OgPrfE49rfRsedKWYaLmaBScvBc_k7hvngc_bARNDStE6bTBDxrD4cNCc6SU0vQtNL6Hpp9BmuvqP3l3wFne25dDPqYzwGOLQ6wybIUQXwRtMWr6u-AspFbIH |
CitedBy_id | crossref_primary_10_2807_1560_7917_ES_2022_27_11_2100119 crossref_primary_10_29392_001c_14598 crossref_primary_10_2486_indhealth_2019_0158 crossref_primary_10_1016_j_ajic_2022_02_009 crossref_primary_10_1038_s41598_021_00341_3 crossref_primary_10_1080_15459624_2019_1609006 crossref_primary_10_1080_15459624_2022_2063875 crossref_primary_10_1093_cid_ciaa1063 crossref_primary_10_1155_2022_1270106 crossref_primary_10_3390_su13020797 crossref_primary_10_4058_jsei_38_7 crossref_primary_10_1093_cid_ciab953 crossref_primary_10_3390_textiles5010009 |
Cites_doi | 10.1080/15459624.2011.585094 10.1080/15428119891011036 10.1080/15428110308984867 10.1371/journal.pone.0085299 10.1016/j.ajic.2013.03.293 10.1080/15459624.2013.843780 10.1080/15459624.2015.1047025 10.1080/15459620500391668 10.1080/15459620701497538 10.1080/15459624.2012.685838 10.1080/15459624.2016.1161198 10.1080/15459620490250026 10.1080/15459624.2012.733578 10.1080/15428119891011027 10.1080/15459620903120086 |
ContentType | Journal Article |
Copyright | This article not subject to U.S. copyright law 2017 |
Copyright_xml | – notice: This article not subject to U.S. copyright law 2017 |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 5PM |
DOI | 10.1080/15459624.2017.1296233 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed PubMed Central (Full Participant titles) |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1545-9632 |
EndPage | 481 |
ExternalDocumentID | PMC5702917 28278067 10_1080_15459624_2017_1296233 1296233 |
Genre | Article Journal Article |
GeographicLocations | United States |
GeographicLocations_xml | – name: United States |
GrantInformation_xml | – fundername: Intramural CDC HHS grantid: CC999999 |
GroupedDBID | --- -~X .7F .QJ 04C 0BK 0R~ 29L 30N 36B 4.4 4P2 53G 5GY 5RE 5VS 6PF 85S AAENE AAJMT AALDU AAMIU AAPUL AAQRR AAWTL ABCCY ABFIM ABLIJ ABPAQ ABPEM ABTAI ABXUL ABXYU ACGEJ ACGFS ACGOD ACIWK ACPRK ACTIO ADBBV ADCVX ADGTB ADOJX ADXPE AEISY AENEX AEOZL AEPSL AEYOC AFOSN AFRAH AGDLA AGMYJ AHDZW AHMBA AIJEM AJWEG AKBVH AKOOK ALMA_UNASSIGNED_HOLDINGS ALQZU AQRUH AVBZW AWYRJ BLEHA BMSDO CCCUG CE4 CS3 DGEBU DKSSO DU5 EBD EBS ECT EDH EIHBH EJD E~A E~B F5P GTTXZ H13 HF~ HZ~ H~P IPNFZ J.P KYCEM LJTGL M4Z NA5 O9- PQQKQ RIG RNANH ROSJB RTWRZ S-T SNACF TBQAZ TDBHL TEI TEN TFL TFT TFW TQWBC TTHFI TUROJ TWF TWQ UT5 UU3 ZE2 ZGOLN ~S~ AAGDL AAHIA AAYXX ADYSH AFRVT AIYEW AMPGV CITATION UT3 8WZ A6W AAGME ABFMO ACDHJ ACZPZ ADOPC AURDB BFWEY CAG CGR COF CUY CVF CWRZV ECM EIF H~9 NPM PCLFJ TASJS WHG 5PM |
ID | FETCH-LOGICAL-c582t-86bc36fae4c77fcfc4953b2534a068c7afd9104a0621aa96317bb4bc97dc02ea3 |
ISSN | 1545-9624 |
IngestDate | Thu Aug 21 13:48:02 EDT 2025 Mon Jul 21 06:02:38 EDT 2025 Thu Apr 24 22:52:45 EDT 2025 Tue Jul 01 03:37:10 EDT 2025 Wed Dec 25 09:03:26 EST 2024 |
IsDoiOpenAccess | false |
IsOpenAccess | true |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 6 |
Keywords | NIOSH-certified respirator Fit test respirator fit capability N95 respirator |
Language | English |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c582t-86bc36fae4c77fcfc4953b2534a068c7afd9104a0621aa96317bb4bc97dc02ea3 |
OpenAccessLink | https://www.ncbi.nlm.nih.gov/pmc/articles/5702917 |
PMID | 28278067 |
PageCount | 9 |
ParticipantIDs | informaworld_taylorfrancis_310_1080_15459624_2017_1296233 crossref_citationtrail_10_1080_15459624_2017_1296233 pubmed_primary_28278067 pubmedcentral_primary_oai_pubmedcentral_nih_gov_5702917 crossref_primary_10_1080_15459624_2017_1296233 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 20170601 |
PublicationDateYYYYMMDD | 2017-06-01 |
PublicationDate_xml | – month: 6 year: 2017 text: 20170601 day: 1 |
PublicationDecade | 2010 |
PublicationPlace | England |
PublicationPlace_xml | – name: England |
PublicationTitle | Journal of occupational and environmental hygiene |
PublicationTitleAlternate | J Occup Environ Hyg |
PublicationYear | 2017 |
Publisher | Taylor & Francis |
Publisher_xml | – name: Taylor & Francis |
References | Lofgren D. (cit0010) 2012; 9 cit0012 U.S Department of Health and Human Service (cit0019) 2010 Shaffer R. (cit0016) 2014; 13 cit0017 cit0015 Yu Y. (cit0025) 2014; 9 cit0013 cit0014 Han H.-S. (cit0022) 2012; 29 cit0001 cit0023 cit0020 Institute of Medicine (cit0009) 2011 cit0021 (cit0002) 1995 Richardson A. (cit0026) 2014; 31 Roberge R.J. (cit0007) 2006; 23 cit0008 cit0006 cit0028 Institute of Medicine (cit0018) 2007 cit0004 cit0005 Institute of Medicine (cit0011) 2011 cit0027 cit0024 cit0003 |
References_xml | – ident: cit0013 – volume: 13 start-page: 23 issue: 1 year: 2014 ident: cit0016 publication-title: J. Int. Soc. Resp. Protect – ident: cit0024 doi: 10.1080/15459624.2011.585094 – ident: cit0004 doi: 10.1080/15428119891011036 – ident: cit0005 doi: 10.1080/15428110308984867 – volume: 9 start-page: e85299 issue: 1 year: 2014 ident: cit0025 publication-title: PLoS One. doi: 10.1371/journal.pone.0085299 – ident: cit0015 doi: 10.1016/j.ajic.2013.03.293 – ident: cit0027 – volume-title: Preventing Transmission of Pandemic Influenza and Other Viral Respiratory Diseases: Personal Protective Equipment for Healthcare Workers: Update 2010 year: 2011 ident: cit0009 – ident: cit0020 doi: 10.1080/15459624.2013.843780 – start-page: 30336 year: 1995 ident: cit0002 publication-title: Code of Federal Regulations – ident: cit0021 doi: 10.1080/15459624.2015.1047025 – ident: cit0006 doi: 10.1080/15459620500391668 – volume-title: Assessment of the NIOSH Head-and-Face Anthropometric Survey of U.S. Respirator Users year: 2007 ident: cit0018 – ident: cit0017 doi: 10.1080/15459620701497538 – ident: cit0014 – volume-title: Certifying Personal Protective Technologies: Improving Worker Safety year: 2011 ident: cit0011 – ident: cit0012 – volume: 23 start-page: 44 year: 2006 ident: cit0007 publication-title: J. Int. Soc. Resp. Protect. – ident: cit0023 doi: 10.1080/15459624.2012.685838 – ident: cit0028 doi: 10.1080/15459624.2016.1161198 – volume: 31 start-page: 43 issue: 1 year: 2014 ident: cit0026 publication-title: J. Int. Soc. Resp. Protect. – ident: cit0008 doi: 10.1080/15459620490250026 – volume: 9 start-page: D191 issue: 12 year: 2012 ident: cit0010 publication-title: J. Occup. Environ. Hyg. doi: 10.1080/15459624.2012.733578 – volume: 29 start-page: 75 issue: 2 year: 2012 ident: cit0022 publication-title: J. Int. Soc. Resp. Protect. – ident: cit0003 doi: 10.1080/15428119891011027 – ident: cit0001 doi: 10.1080/15459620903120086 – volume-title: NIOSH Investigation of 3M Model 8000 Filtering Facepiece Respirators As Requested By The California Occupational Safety and Health Administration, Division of Occupational Safety and Health (Health Hazard Evaluation Report, HETA 2010-0044-3109) year: 2010 ident: cit0019 |
SSID | ssj0026136 |
Score | 2.1784372 |
Snippet | This study assessed key test parameters and pass/fail criteria options for developing a respirator fit capability (RFC) test for half-mask air-purifying... |
SourceID | pubmedcentral pubmed crossref informaworld |
SourceType | Open Access Repository Index Database Enrichment Source Publisher |
StartPage | 473 |
SubjectTerms | Equipment Design Fit test Humans Masks - standards Materials Testing - methods N95 respirator National Institute for Occupational Safety and Health, U.S NIOSH-certified respirator Occupational Exposure - prevention & control respirator fit capability Respiratory Protective Devices - standards United States |
Title | Recommended test methods and pass/fail criteria for a respirator fit capability test of half-mask air-purifying respirators |
URI | https://www.tandfonline.com/doi/abs/10.1080/15459624.2017.1296233 https://www.ncbi.nlm.nih.gov/pubmed/28278067 https://pubmed.ncbi.nlm.nih.gov/PMC5702917 |
Volume | 14 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lb5wwELa2G6nqpeo725d86A2x4WEwHKO20apSc0rUaC_IGJNF3VdZ9pD0Z_YPdfwATJs2TS9o1-DB7Hxrj4dvZhB65wmVhUy4VJDCJeolYZxyl5IilRHhYVAotsVpPDsnny6ii9Hoh8Va2jf5lF_fGFfyP1qFNtCrjJK9g2Y7odAAn0G_cAQNw_GfdCz3jquVcmI7YDI2ph60Tru8ZbIe-knJqqUDU4PMycw0Z9Kpu_frTlk1DocFU3Fkr7QUaT-yZemu2O6rw6ra3e7rSsdD9T13fzBrN3baYjkOK5ROxl1eXcJk0qFpvtgbh_W8-tauoipsqL40vlmb2K-YQ4p_MF9UW9Fff1qJa9hhs97Nb7szfNrTrtoZmEQAFx1YPRV2WzictokFT3sOJro2ilnOia4I89tKoamVUrK8meT40SnYPmANhv3S2NIBflkxOx6jbxKstmIyKSYzYu6hg4CCQTdGB8ezD_MvnR8ALCgV9NY-aRtYlnhHN45nYDINEupaZtOQ0mvZSGeP0EODAnyskfoYjcT6Cbr_2dA3nqLvFmCxhBo2gMUAFCwBeyThilu4YhgDZrgHHQa44h6uWsamxB1c8QCuVs_dM3R-8vHs_cw11T9cHiVB4yZxzsO4ZIJwSktecsmEzoMoJMyLE05ZWYCpK78EPmOADp_mOcl5SgvuBYKFz9F4vVmLQ4TzMBU8KlLY6ySE-xErOMth78G5CJJYpBNE2h844yY1vqzQssz-quAJmnbdtjo3zG0dUlt7WaOccqWuoJOFt_R9oTXc3SpIApqAsTlBdKD77gKZOX54Zl0tVAb5iHpB6tOXd32AV-hB_599jcZNvRdvwChv8rcG5D8BnB7f4Q |
linkProvider | Library Specific Holdings |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1LT9wwELYoSG0vQB-ULYX60KuXPJw4OVYItC2wJ5C4RfbEFhG7y2o3e2j584ztJEoqVRw45jF27NieGfubbwj5EWjHQqaZ0Lxk3B0SpjkwwcvcRoTHUenQFtN0cst_3yV3vVgYC6u0PrTxRBFurbaT225Gt5C4U6v28zSyWyKhGKPGQh0evyE7eDOwsL44mHZOF6orF2GEIszKtFE8_ytmoJ8G7KU9HTXET_YU0sUegbYpHofyMN7Uagx__2F5fF1b98luY6_Sn36AfSBbevGRvL1uTuQ_kSfrv87nbiOdotlaU5-Tek2xSrpE0_zUyGpGcXGyrNCSYkuppKvuhJ-aqqaAKtuhdP_4Mh4NvZczw-Zy_UBltWLLzapyEVk9yfVncntxfnM2YU1CBwZJFtUsSxXEqZGagxAGDFhwq4qSmMsgzUBIU6L1Yi-iUEpcGkKhFFeQixKCSMv4gGwvHhf6kFAV5xqSMkfzNeMQJrIEqdCcBNBRlup8RHj7Gwto2M5t0o1ZETakqG3HFrZji6ZjR2TciS093cdLAnl_jBS122cxPilKEb8g-8WPo64q9H9FhvbDiIjBCOtesGTgwyeL6t6RgiciiND1_vqK7_lO3k1urq-Kq1_TyyPy3j7yoLhvZLtebfQxml-1OnHz6xloPiNx |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Lb9QwELagSBUXKK-yUMAHrt4msRPHRwRdldeKA5W4RfbEVqPuble72QPw5xnbSbRBqnroMXLGjp2xZ8b-5jMh7xMbWMgsk1bUTIRDwkIBk6JWPiOcZ3VAW8yL8wvx5Vfeowm3HazSx9AuEkWEtdpP7nXtekTcqbf6qsj8jkgqp2iw0ITz--RBkXDl6fN5Mh9iLrRWIcEIRZiX6ZN4bqpmZJ5G5KV7JmoMn9yzR7PHxPQ9iTCUq-muNVP48x_J4526ekQedd4q_RDV6wm5Z1dPyeH37jz-Gfnro9flMmyjU3RaWxpvpN5SbJGu0TE_dbpZUFyaPCe0pthRqulmON-nrmkpoMEOGN3fsY5rRy_1wrGl3l5R3WzYerdpQj7WnuT2ObmYnf38eM666xwY5GXWsrIwwAunrQApHTjw0FaT5VzopChBalej7-IfslRrXBhSaYwwoGQNSWY1f0EOVtcr-5JQw5WFvFbovJYC0lzXoA06kwA2KwurJkT0f7GCjuvcX7mxqNKOErUf2MoPbNUN7IRMB7F1JPu4TUDtq0jVhl0WF69EqfgtssdRjYamMPqVJXoPEyJHCja84KnAxyWr5jJQgucyyTDwfnWH73lHDn98mlXfPs-_viYPfUlExJ2Qg3azs2_Q92rN2zC7_gHTniIe |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Recommended+test+methods+and+pass%2Ffail+criteria+for+a+respirator+fit+capability+test+of+half-mask+air-purifying+respirators&rft.jtitle=Journal+of+occupational+and+environmental+hygiene&rft.au=Zhuang%2C+Ziqing&rft.au=Bergman%2C+Michael&rft.au=Lei%2C+Zhipeng&rft.au=Niezgoda%2C+George&rft.date=2017-06-01&rft.issn=1545-9624&rft.eissn=1545-9632&rft.volume=14&rft.issue=6&rft.spage=473&rft.epage=481&rft_id=info:doi/10.1080%2F15459624.2017.1296233&rft.externalDBID=n%2Fa&rft.externalDocID=10_1080_15459624_2017_1296233 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1545-9624&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1545-9624&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1545-9624&client=summon |