Body-Worn IMU-Based Human Hip and Knee Kinematics Estimation during Treadmill Walking
Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability condition...
Saved in:
| Published in | Sensors (Basel, Switzerland) Vol. 22; no. 7; p. 2544 |
|---|---|
| Main Authors | , |
| Format | Journal Article |
| Language | English |
| Published |
Switzerland
MDPI AG
26.03.2022
MDPI |
| Subjects | |
| Online Access | Get full text |
| ISSN | 1424-8220 1424-8220 |
| DOI | 10.3390/s22072544 |
Cover
| Abstract | Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated (N=12) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87∘ absolute root mean square error (RMSE)), hip flexion/extension angle (3.70∘ relative RMSE), and hip abduction/adduction angle (4.56∘ relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27∘ relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking). |
|---|---|
| AbstractList | Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated ( N=12 ) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87 ∘ absolute root mean square error (RMSE)), hip flexion/extension angle (3.70 ∘ relative RMSE), and hip abduction/adduction angle (4.56 ∘ relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27 ∘ relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking). Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated (N=12) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87∘ absolute root mean square error (RMSE)), hip flexion/extension angle (3.70∘ relative RMSE), and hip abduction/adduction angle (4.56∘ relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27∘ relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking).Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated (N=12) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87∘ absolute root mean square error (RMSE)), hip flexion/extension angle (3.70∘ relative RMSE), and hip abduction/adduction angle (4.56∘ relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27∘ relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking). Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore all of their degrees of freedom. Pure human walking, in contrast, limits the motion of human joints and may lead to unobservability conditions that confound magnetometer-free IMU-based methods. This work explores the unobservability conditions emergent during human walking and expands upon a previous IMU-based method for the human knee to also estimate human hip angles relative to an assumed vertical datum. The proposed method is evaluated (N=12) in a human subject study and compared against an optical motion capture system. Accuracy of human knee flexion/extension angle (7.87∘ absolute root mean square error (RMSE)), hip flexion/extension angle (3.70∘ relative RMSE), and hip abduction/adduction angle (4.56∘ relative RMSE) during walking are similar to current state-of-the-art self-calibrating IMU methods that use magnetometers. Larger errors of hip internal/external rotation angle (6.27∘ relative RMSE) are driven by IMU heading drift characteristic of magnetometer-free approaches and non-hinge kinematics of the hip during gait, amongst other error sources. One of these sources of error, soft tissue perturbations during gait, is explored further in the context of knee angle estimation and it was observed that the IMU method may overestimate the angle during stance and underestimate the angle during swing. The presented method and results provide a novel combination of observability considerations, heuristic correction methods, and validation techniques to magnetic-blind, kinematic-only IMU-based skeletal pose estimation during human tasks with degenerate kinematics (e.g., straight line walking). |
| Author | Stirling, Leia McGrath, Timothy |
| AuthorAffiliation | 3 Robotics Institute, University of Michigan, 2505 Hayward St, Ann Arbor, MI 48109, USA 1 Department of Aeronautics and Astronautics, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA 2 Industrial and Operations Engineering, University of Michigan, 1205 Beal Avenue, Ann Arbor, MI 48109, USA; leias@umich.edu |
| AuthorAffiliation_xml | – name: 3 Robotics Institute, University of Michigan, 2505 Hayward St, Ann Arbor, MI 48109, USA – name: 2 Industrial and Operations Engineering, University of Michigan, 1205 Beal Avenue, Ann Arbor, MI 48109, USA; leias@umich.edu – name: 1 Department of Aeronautics and Astronautics, Massachusetts Institute of Technology, 77 Massachusetts Avenue, Cambridge, MA 02139, USA |
| Author_xml | – sequence: 1 givenname: Timothy orcidid: 0000-0002-6582-0865 surname: McGrath fullname: McGrath, Timothy – sequence: 2 givenname: Leia orcidid: 0000-0002-0119-1617 surname: Stirling fullname: Stirling, Leia |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/35408159$$D View this record in MEDLINE/PubMed |
| BookMark | eNp9kVFrFDEUhYNUbLv64B-QgC9WGJtJMpmZF8GW6i6t-LKlj-FOklmzZpNtMmPZf2-6W5e2iBDI5eTL4dx7j9GBD94g9LYknxhryWmilNS04vwFOio55UWThYNH9SE6TmlJCGWMNa_QIas4acqqPULXZ0FvipsQPZ59vy7OIBmNp-MKPJ7aNQav8aU3Bl9ab1YwWJXwRRrsfRk81mO0foHn0YBeWefwDbhfWXmNXvbgknnzcE_Q_OvF_HxaXP34Njv_clWoilVD0ROhGQFGu1IAq5hSgiihesMpU0ITXveEqJqZRpU9dJywjOteZyyn79gEzXa2OsBSrmOOFTcygJVbIcSFhJgzOyNbISiHXkDbA--E6epWUMUZdKZrmlpnr487r9GvYXMHzu0NSyLvxyz3Y87w5x28HruV0cr4IYJ7kuDpi7c_5SL8li0hjJE2G3x4MIjhdjRpkCublHEOvAljklTwtmpLnjc2Qe-focswRp_HuqVIW7J8Jujd40T7KH83nYGTHaBiSCma_r_tnT5jlR22G8_NWPePH38AQgrGIg |
| CitedBy_id | crossref_primary_10_3390_s22155657 crossref_primary_10_3390_s23167053 crossref_primary_10_3390_s25010118 crossref_primary_10_1016_j_cobme_2023_100492 crossref_primary_10_3390_s23084000 crossref_primary_10_3390_s22134898 crossref_primary_10_3390_s23010348 crossref_primary_10_1016_j_knee_2024_10_006 crossref_primary_10_3390_s22249850 crossref_primary_10_1016_j_jbiomech_2024_112091 crossref_primary_10_1109_JSEN_2023_3325153 crossref_primary_10_3390_math11040970 crossref_primary_10_3390_s24134306 crossref_primary_10_3390_s25071976 crossref_primary_10_1016_j_jbiomech_2024_112225 crossref_primary_10_1186_s12984_024_01426_6 crossref_primary_10_3390_biomechanics5010002 crossref_primary_10_12688_openreseurope_16939_1 crossref_primary_10_12688_openreseurope_16939_2 crossref_primary_10_1016_j_gaitpost_2025_01_028 crossref_primary_10_3390_ijerph192013093 crossref_primary_10_3390_s23249801 crossref_primary_10_3390_s24041302 crossref_primary_10_1038_s41598_024_59949_w |
| Cites_doi | 10.3390/s18092759 10.23919/ACC.2017.7963159 10.1109/ICCA.2009.5410185 10.3390/s20123534 10.1109/EMBC.2019.8857535 10.1109/EMBC.2014.6944082 10.1371/journal.pone.0214008 10.1016/j.jbiomech.2020.109832 10.12720/ijsps.1.2.256-262 10.3390/s140406891 10.1109/10.102791 10.3390/s121012927 10.1371/journal.pone.0118723 10.1145/2829875.2829930 10.3390/diagnostics10060342 10.1109/MED.2009.5164574 10.3390/s19112474 10.1007/978-3-642-31567-1_11 10.4108/icst.bodynets.2014.257048 10.1016/j.jbiomech.2009.06.025 10.1016/j.jbiomech.2007.12.003 10.3233/THC-1999-7612 10.3182/20140824-6-ZA-1003.02252 10.3389/fpsyg.2017.00817 10.1371/journal.pone.0087640 10.1016/0141-1195(86)90098-7 10.1002/jor.1100080310 10.1016/j.jbiomech.2005.02.008 10.1016/j.gaitpost.2010.08.010 10.1016/j.ergon.2020.102937 10.1063/1.3528102 10.1109/ICORR.2017.8009375 10.3390/s18010302 10.1109/BSN.2013.6575461 10.1109/TNSRE.2005.847353 10.1109/TBME.2007.901024 10.4108/icst.bodynets.2013.253679 10.1016/S0021-9290(01)00231-7 10.3390/s16071132 10.1016/j.gaitpost.2017.06.019 10.1371/journal.pcbi.1006223 10.3390/s20236887 10.1115/1.1392310 10.1080/10255849908907988 10.1016/0167-9457(91)90046-Z 10.3357/AMHP.5123.2018 10.1016/j.procs.2014.07.009 10.1007/BFb0067700 10.1016/0021-9290(89)90179-6 10.3390/s19235143 10.23919/FUSION43075.2019.9011409 10.4108/eai.28-9-2015.2261522 10.1016/j.jbiomech.2005.11.011 10.1007/s11517-009-0545-x 10.1109/JBHI.2016.2639537 10.1016/0021-9290(92)90254-X 10.1115/1.3138397 10.3390/s18061882 10.23919/ECC.2019.8795846 10.1016/S0021-9290(01)00222-6 |
| ContentType | Journal Article |
| Copyright | 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. 2022 by the authors. 2022 |
| Copyright_xml | – notice: 2022 by the authors. Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License. – notice: 2022 by the authors. 2022 |
| DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 3V. 7X7 7XB 88E 8FI 8FJ 8FK ABUWG AFKRA AZQEC BENPR CCPQU DWQXO FYUFA GHDGH K9. M0S M1P PHGZM PHGZT PIMPY PJZUB PKEHL PPXIY PQEST PQQKQ PQUKI PRINS 7X8 5PM ADTOC UNPAY DOA |
| DOI | 10.3390/s22072544 |
| DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed ProQuest Central (Corporate) Health & Medical Collection ProQuest Central (purchase pre-March 2016) Medical Database (Alumni Edition) Hospital Premium Collection Hospital Premium Collection (Alumni Edition) ProQuest Central (Alumni) (purchase pre-March 2016) ProQuest Central (Alumni) ProQuest Central UK/Ireland ProQuest Central Essentials ProQuest Central ProQuest One Community College ProQuest Central Health Research Premium Collection Health Research Premium Collection (Alumni) ProQuest Health & Medical Complete (Alumni) Health & Medical Collection (Alumni Edition) Medical Database ProQuest Central Premium ProQuest One Academic Publicly Available Content Database ProQuest Health & Medical Research Collection ProQuest One Academic Middle East (New) ProQuest One Health & Nursing ProQuest One Academic Eastern Edition (DO NOT USE) ProQuest One Academic ProQuest One Academic UKI Edition ProQuest Central China MEDLINE - Academic PubMed Central (Full Participant titles) Unpaywall for CDI: Periodical Content Unpaywall DOAJ Directory of Open Access Journals |
| DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Publicly Available Content Database ProQuest One Academic Middle East (New) ProQuest Central Essentials ProQuest Health & Medical Complete (Alumni) ProQuest Central (Alumni Edition) ProQuest One Community College ProQuest One Health & Nursing ProQuest Central China ProQuest Central ProQuest Health & Medical Research Collection Health Research Premium Collection Health and Medicine Complete (Alumni Edition) ProQuest Central Korea Health & Medical Research Collection ProQuest Central (New) ProQuest Medical Library (Alumni) ProQuest One Academic Eastern Edition ProQuest Hospital Collection Health Research Premium Collection (Alumni) ProQuest Hospital Collection (Alumni) ProQuest Health & Medical Complete ProQuest Medical Library ProQuest One Academic UKI Edition ProQuest One Academic ProQuest One Academic (New) ProQuest Central (Alumni) MEDLINE - Academic |
| DatabaseTitleList | MEDLINE - Academic MEDLINE CrossRef Publicly Available Content Database |
| Database_xml | – sequence: 1 dbid: DOA name: DOAJ Directory of Open Access Journals url: https://www.doaj.org/ sourceTypes: Open Website – sequence: 2 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 3 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database – sequence: 4 dbid: UNPAY name: Unpaywall url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/ sourceTypes: Open Access Repository – sequence: 5 dbid: BENPR name: ProQuest Central url: http://www.proquest.com/pqcentral?accountid=15518 sourceTypes: Aggregation Database |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Engineering |
| EISSN | 1424-8220 |
| ExternalDocumentID | oai_doaj_org_article_96624af6a9fa4b6eb7962c43abeb887d 10.3390/s22072544 PMC9003309 35408159 10_3390_s22072544 |
| Genre | Journal Article |
| GrantInformation_xml | – fundername: National Science Foundation grantid: IIS-1453141 |
| GroupedDBID | --- 123 2WC 53G 5VS 7X7 88E 8FE 8FG 8FI 8FJ AADQD AAHBH AAYXX ABDBF ABUWG ACUHS ADBBV ADMLS AENEX AFKRA AFZYC ALMA_UNASSIGNED_HOLDINGS BENPR BPHCQ BVXVI CCPQU CITATION CS3 D1I DU5 E3Z EBD ESX F5P FYUFA GROUPED_DOAJ GX1 HH5 HMCUK HYE IAO ITC KQ8 L6V M1P M48 MODMG M~E OK1 OVT P2P P62 PHGZM PHGZT PIMPY PJZUB PPXIY PQQKQ PROAC PSQYO RNS RPM TUS UKHRP XSB ~8M 3V. ABJCF ALIPV ARAPS CGR CUY CVF ECM EIF HCIFZ KB. M7S NPM PDBOC 7XB 8FK AZQEC DWQXO K9. PKEHL PQEST PQUKI PRINS 7X8 PUEGO 5PM ADRAZ ADTOC IPNFZ RIG UNPAY |
| ID | FETCH-LOGICAL-c535t-f06d30a32b16a353cc60c6cfe423c6d047f00c73e8c1fab403d30dfdc60815b3 |
| IEDL.DBID | M48 |
| ISSN | 1424-8220 |
| IngestDate | Fri Oct 03 12:45:13 EDT 2025 Sun Oct 26 03:51:58 EDT 2025 Tue Sep 30 16:33:53 EDT 2025 Wed Oct 01 12:19:59 EDT 2025 Tue Oct 07 07:30:37 EDT 2025 Wed Feb 19 02:26:41 EST 2025 Thu Oct 16 04:29:54 EDT 2025 Thu Apr 24 23:08:19 EDT 2025 |
| IsDoiOpenAccess | true |
| IsOpenAccess | true |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 7 |
| Keywords | IMU knee gait walking joint angle biomechanics soft tissue artifacts human self-calibrating hip treadmill |
| Language | English |
| License | Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). cc-by |
| LinkModel | DirectLink |
| MergedId | FETCHMERGED-LOGICAL-c535t-f06d30a32b16a353cc60c6cfe423c6d047f00c73e8c1fab403d30dfdc60815b3 |
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 This author performed this work while employed by the Massachusetts Institute of Technology. The author is currently an employee of JES Tech, LLC, 16870 Royal Crest Dr, Houston, TX 77058, USA. |
| ORCID | 0000-0002-6582-0865 0000-0002-0119-1617 |
| OpenAccessLink | http://journals.scholarsportal.info/openUrl.xqy?doi=10.3390/s22072544 |
| PMID | 35408159 |
| PQID | 2649091391 |
| PQPubID | 2032333 |
| ParticipantIDs | doaj_primary_oai_doaj_org_article_96624af6a9fa4b6eb7962c43abeb887d unpaywall_primary_10_3390_s22072544 pubmedcentral_primary_oai_pubmedcentral_nih_gov_9003309 proquest_miscellaneous_2649591402 proquest_journals_2649091391 pubmed_primary_35408159 crossref_primary_10_3390_s22072544 crossref_citationtrail_10_3390_s22072544 |
| PublicationCentury | 2000 |
| PublicationDate | 20220326 |
| PublicationDateYYYYMMDD | 2022-03-26 |
| PublicationDate_xml | – month: 3 year: 2022 text: 20220326 day: 26 |
| PublicationDecade | 2020 |
| PublicationPlace | Switzerland |
| PublicationPlace_xml | – name: Switzerland – name: Basel |
| PublicationTitle | Sensors (Basel, Switzerland) |
| PublicationTitleAlternate | Sensors (Basel) |
| PublicationYear | 2022 |
| Publisher | MDPI AG MDPI |
| Publisher_xml | – name: MDPI AG – name: MDPI |
| References | Luinge (ref_26) 1999; 7 ref_50 Ahmad (ref_10) 2013; 1 Kok (ref_28) 2014; 19 ref_14 ref_13 ref_12 ref_56 ref_11 Vitali (ref_25) 2020; 106 ref_55 Seel (ref_35) 2014; 14 Chen (ref_65) 2020; 5 ref_52 ref_51 Lafortune (ref_63) 1992; 25 ref_19 ref_18 ref_16 ref_15 Delp (ref_5) 2007; 54 ref_61 Davis (ref_6) 1991; 10 Grood (ref_54) 1983; 105 ref_22 ref_21 Vienne (ref_1) 2017; 8 ref_20 Delp (ref_57) 1990; 37 Anderson (ref_60) 2001; 123 ref_29 Favre (ref_33) 2008; 41 Wu (ref_53) 2002; 35 Muller (ref_42) 2017; 21 Roetenberg (ref_48) 2005; 13 Dadashi (ref_17) 2012; 12 Desloovere (ref_62) 2010; 32 Caldas (ref_2) 2017; 57 Lim (ref_3) 2020; 76 ref_36 Yamaguchi (ref_58) 1989; 1 ref_30 Camomilla (ref_64) 2006; 39 ref_39 ref_38 ref_37 Luinge (ref_31) 2007; 40 Bayat (ref_23) 2014; 34 Favre (ref_34) 2009; 42 ref_47 ref_46 Cutti (ref_32) 2010; 48 ref_45 ref_44 Woltring (ref_8) 1986; 8 ref_43 ref_41 Mayagoitia (ref_27) 2002; 35 ref_40 Fineman (ref_24) 2018; 89 ref_49 ref_9 Anderson (ref_59) 1999; 2 ref_4 Kadaba (ref_7) 1990; 8 |
| References_xml | – ident: ref_39 doi: 10.3390/s18092759 – ident: ref_21 doi: 10.23919/ACC.2017.7963159 – ident: ref_9 doi: 10.1109/ICCA.2009.5410185 – ident: ref_41 doi: 10.3390/s20123534 – ident: ref_43 doi: 10.1109/EMBC.2019.8857535 – ident: ref_30 doi: 10.1109/EMBC.2014.6944082 – ident: ref_18 doi: 10.1371/journal.pone.0214008 – volume: 106 start-page: 109832 year: 2020 ident: ref_25 article-title: Determining anatomical frames via inertial motion capture: A survey of methods publication-title: J. Biomech. doi: 10.1016/j.jbiomech.2020.109832 – volume: 1 start-page: 256 year: 2013 ident: ref_10 article-title: Reviews on Various Inertial Measurement Unit (IMU) Sensor Applications publication-title: Int. J. Signal Process. Syst. doi: 10.12720/ijsps.1.2.256-262 – volume: 14 start-page: 6891 year: 2014 ident: ref_35 article-title: IMU-based joint angle measurement for gait analysis publication-title: Sensors doi: 10.3390/s140406891 – volume: 37 start-page: 757 year: 1990 ident: ref_57 article-title: An Interactive Graphics-Based Model of the Lower Extremity to Study Orthopaedic Surgical Procedures publication-title: IEEE Trans. Biomed. Eng. doi: 10.1109/10.102791 – ident: ref_16 – volume: 12 start-page: 12927 year: 2012 ident: ref_17 article-title: Front-crawl instantaneous velocity estimation using a wearable inertial measurement unit publication-title: Sensors doi: 10.3390/s121012927 – ident: ref_22 doi: 10.1371/journal.pone.0118723 – ident: ref_14 doi: 10.1145/2829875.2829930 – ident: ref_13 doi: 10.3390/diagnostics10060342 – ident: ref_20 doi: 10.1109/MED.2009.5164574 – ident: ref_61 doi: 10.3390/s19112474 – ident: ref_19 doi: 10.1007/978-3-642-31567-1_11 – ident: ref_12 doi: 10.4108/icst.bodynets.2014.257048 – ident: ref_56 – volume: 42 start-page: 2330 year: 2009 ident: ref_34 article-title: Functional calibration procedure for 3D knee joint angle description using inertial sensors publication-title: J. Biomech. doi: 10.1016/j.jbiomech.2009.06.025 – volume: 41 start-page: 1029 year: 2008 ident: ref_33 article-title: Ambulatory measurement of 3D knee joint angle publication-title: J. Biomech. doi: 10.1016/j.jbiomech.2007.12.003 – volume: 7 start-page: 455 year: 1999 ident: ref_26 article-title: Estimating orientation with gyroscopes and accelerometers publication-title: Technol. Health Care doi: 10.3233/THC-1999-7612 – volume: 19 start-page: 79 year: 2014 ident: ref_28 article-title: An optimization-based approach to human body motion capture using inertial sensors publication-title: IFAC Proc. Vol.-(IFAC-Pap.) doi: 10.3182/20140824-6-ZA-1003.02252 – volume: 8 start-page: 817 year: 2017 ident: ref_1 article-title: Inertial sensors to assess gait quality in patients with neurological disorders: A systematic review of technical and analytical challenges publication-title: Front. Psychol. doi: 10.3389/fpsyg.2017.00817 – ident: ref_4 doi: 10.1371/journal.pone.0087640 – volume: 8 start-page: 104 year: 1986 ident: ref_8 article-title: A Fortran package for generalized, cross-validatory spline smoothing and differentiation publication-title: Adv. Eng. Softw. (1978) doi: 10.1016/0141-1195(86)90098-7 – volume: 8 start-page: 383 year: 1990 ident: ref_7 article-title: Measurement of Lower-Extremity Kinematics during Level Walking publication-title: J. Orthop. Res. doi: 10.1002/jor.1100080310 – volume: 39 start-page: 1096 year: 2006 ident: ref_64 article-title: An optimized protocol for hip joint centre determination using the functional method publication-title: J. Biomech. doi: 10.1016/j.jbiomech.2005.02.008 – volume: 32 start-page: 597 year: 2010 ident: ref_62 article-title: Range of motion and repeatability of knee kinematics for 11 clinically relevant motor tasks publication-title: Gait Posture doi: 10.1016/j.gaitpost.2010.08.010 – volume: 76 start-page: 102937 year: 2020 ident: ref_3 article-title: A narrative review on contemporary and emerging uses of inertial sensing in occupational ergonomics publication-title: Int. J. Ind. Ergon. doi: 10.1016/j.ergon.2020.102937 – ident: ref_51 doi: 10.1063/1.3528102 – ident: ref_37 doi: 10.1109/ICORR.2017.8009375 – ident: ref_45 doi: 10.3390/s18010302 – ident: ref_15 doi: 10.1109/BSN.2013.6575461 – volume: 13 start-page: 395 year: 2005 ident: ref_48 article-title: Compensation of magnetic disturbances improves inertial and magnetic sensing of human body segment orientation publication-title: IEEE Trans. Neural Syst. Rehabil. Eng. doi: 10.1109/TNSRE.2005.847353 – volume: 54 start-page: 1940 year: 2007 ident: ref_5 article-title: OpenSim: Open source to create and analyze dynamic simulations of movement publication-title: IEEE Trans. Bio-Med. Eng. doi: 10.1109/TBME.2007.901024 – ident: ref_11 doi: 10.4108/icst.bodynets.2013.253679 – volume: 35 start-page: 537 year: 2002 ident: ref_27 article-title: Accelerometer and rate gyroscope measurement of kinematics: An inexpensive alternative to optical motion analysis systems publication-title: J. Biomech. doi: 10.1016/S0021-9290(01)00231-7 – ident: ref_29 doi: 10.3390/s16071132 – volume: 57 start-page: 204 year: 2017 ident: ref_2 article-title: A systematic review of gait analysis methods based on inertial sensors and adaptive algorithms publication-title: Gait Posture doi: 10.1016/j.gaitpost.2017.06.019 – ident: ref_52 doi: 10.1371/journal.pcbi.1006223 – ident: ref_47 doi: 10.3390/s20236887 – volume: 123 start-page: 381 year: 2001 ident: ref_60 article-title: Dynamic optimization of human walking publication-title: J. Biomech. Eng. doi: 10.1115/1.1392310 – volume: 2 start-page: 201 year: 1999 ident: ref_59 article-title: A dynamic optimization solution for vertical jumping in three dimensions publication-title: Comput. Methods Biomech. Biomed. Eng. doi: 10.1080/10255849908907988 – volume: 10 start-page: 575 year: 1991 ident: ref_6 article-title: A gait analysis data collection and reduction technique publication-title: Hum. Mov. Sci. doi: 10.1016/0167-9457(91)90046-Z – volume: 89 start-page: 985 year: 2018 ident: ref_24 article-title: Objective metrics quantifying fit and performance in spacesuit assemblies publication-title: Aerosp. Med. Hum. Perform. doi: 10.3357/AMHP.5123.2018 – volume: 34 start-page: 450 year: 2014 ident: ref_23 article-title: A study on human activity recognition using accelerometer data from smartphones publication-title: Procedia Comput. Sci. doi: 10.1016/j.procs.2014.07.009 – ident: ref_55 doi: 10.1007/BFb0067700 – volume: 1 start-page: 1 year: 1989 ident: ref_58 article-title: A planar model of the knee joint to characterize the knee extensor mechanism publication-title: J. Biomech. doi: 10.1016/0021-9290(89)90179-6 – ident: ref_44 – ident: ref_46 doi: 10.3390/s19235143 – ident: ref_40 doi: 10.23919/FUSION43075.2019.9011409 – ident: ref_50 – ident: ref_36 doi: 10.4108/eai.28-9-2015.2261522 – volume: 40 start-page: 78 year: 2007 ident: ref_31 article-title: Ambulatory measurement of arm orientation publication-title: J. Biomech. doi: 10.1016/j.jbiomech.2005.11.011 – volume: 48 start-page: 17 year: 2010 ident: ref_32 article-title: ‘Outwalk’: A protocol for clinical gait analysis based on inertial and magnetic sensors publication-title: Med. Biol. Eng. Comput. doi: 10.1007/s11517-009-0545-x – volume: 21 start-page: 312 year: 2017 ident: ref_42 article-title: Alignment-Free, Self-Calibrating Elbow Angles Measurement Using Inertial Sensors publication-title: IEEE J. Biomed. Health Inform. doi: 10.1109/JBHI.2016.2639537 – volume: 25 start-page: 347 year: 1992 ident: ref_63 article-title: Three-dimensional kinematics of the human knee during walking publication-title: J. Biomech. Eng. doi: 10.1016/0021-9290(92)90254-X – volume: 105 start-page: 136 year: 1983 ident: ref_54 article-title: A Joint Coordinate System for the Clinical Description of Three-Dimensional Motions: Application to the Knee publication-title: J. Biomech. Eng. doi: 10.1115/1.3138397 – volume: 5 start-page: 4671 year: 2020 ident: ref_65 article-title: Drift-Free and Self-Aligned IMU-Based Human Gait Tracking System with Augmented Precision and Robustness publication-title: IEEE Robot. Autom. Lett. – ident: ref_38 doi: 10.3390/s18061882 – ident: ref_49 doi: 10.23919/ECC.2019.8795846 – volume: 35 start-page: 543 year: 2002 ident: ref_53 article-title: ISB recommendation on definitions of joint coordinate system of various joints for the reporting of human joint motion—Part I: Ankle, hip, and spine publication-title: J. Biomech. doi: 10.1016/S0021-9290(01)00222-6 |
| SSID | ssj0023338 |
| Score | 2.4793732 |
| Snippet | Traditionally, inertial measurement unit (IMU)-based human joint angle estimation techniques are evaluated for general human motion where human joints explore... |
| SourceID | doaj unpaywall pubmedcentral proquest pubmed crossref |
| SourceType | Open Website Open Access Repository Aggregation Database Index Database Enrichment Source |
| StartPage | 2544 |
| SubjectTerms | Biomechanical Phenomena Biomechanics Fitness equipment Gait human Humans IMU joint angle Kinematics knee Knee Joint Methods Motion capture Range of Motion, Articular self-calibrating Sensors Walking |
| SummonAdditionalLinks | – databaseName: DOAJ Directory of Open Access Journals dbid: DOA link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV3Nb9MwFLfQLsABAWMQGJMHO-xizfFXkiNFmwrTOLXabpH97IhJVVqtrdD-e57jNGq1oV045BI_S9b7iN_P8fs9Qk4i55x1oJkGLZjyGlgFRWCYfEhvfQkqj4XCV7_MeKp-3uibrVZf8U5YogdOijvDdFwo2xhbNVY5E1xRGQFKWhccBoiPX19eVhsw1UMticgr8QhJBPVnSyF4Ecm4dnafjqT_sczy4QXJ5-t2Ye__2Nlsa_e5eE1e9Wkj_ZaW-4Y8C-1b8nKLTHCfTEdzf8-u53ct_XE1ZSPcnjztzujp-HZBbevpJQrTS5zS8bQu6TnGdypdpKlckU4wh_SxExG9trN4iv6OTC7OJ9_HrG-awEBLvWINN15yK4XLjZVaAhgOBpqAeRMYz1XRcA6FDCXkjXWKSxT3jUexMtdOHpC9dt6GD4Rq7oStEAAiRlTgTIlPyMGC80qjCTJyutFlDT2heOxrMasRWES114PaM_JlEF0kFo3HhEbRIINAJL7uXqA71L071E-5Q0YON-as-2hc1pj0VR3_aZ6R42EY4yj-HLFtmK-TjK4QboqMvE_WH1YSz8ZQOVVGih2_2Fnq7kh7-7vj6o4HxZLjzK-DB_1bAx__hwY-kRcilmhwyYQ5JHuru3X4jInTyh11MfIX1dMXQQ priority: 102 providerName: Directory of Open Access Journals – databaseName: ProQuest Central dbid: BENPR link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1Lb9QwEB6V7QE4VDxLoCDzOHCx6viVzQEhFm21UHWF0K7aW-RHApVWybIPVf33jPOiKwqHXOKxNBp7PA97vgF4FzDnjHWKKqc4lV45mrokp-h8CG_80Mk4FAqfTfVkLr9eqIs9mHa1MOFZZXcm1ge1r1zIkR-j4U5rDMv44_IXDV2jwu1q10LDtK0V_IcaYuwO7POAjDWA_dF4-u17H4IJjMgafCGBwf7xmnOWBJCuHatUg_ff5nH-_XDy7rZcmusrs1jcsEonD-CgdSfJp2b9H8JeXj6C-zdABh_DfFT5a3perUry5WxOR2i2PKlz92RyuSSm9OQUickpTqnxW9dkjHrflDSSpoyRzNC39KFDETk3i5BdfwKzk_Hs84S2zRSoU0JtaMG0F8wIbmNthBLOaea0K3L0p5z2TCYFYy4R-dDFhbGSCST3hUeyYayseAqDsirzZ0AUs9ykGBhi7Cid1UP88tgZZ71U3MkI3neyzFwLNB76XSwyDDiC2LNe7BG86UmXDbrGbUSjsCA9QQDErn9Uqx9Zq18ZRm1cmkKbtDAS-bFJqpEXYWxu8Rz1ERx1y5m1WrrO_uypCF73w6hf4dLElHm1bWhUimEoj-CwWf2ek5AzQ-GkESQ7-2KH1d2R8vJnjeEdEsiC4cy3_Q76twSe_5_5F3CPh6IMJijXRzDYrLb5S3SVNvZVu_9_A1YmFEw priority: 102 providerName: ProQuest – databaseName: Unpaywall dbid: UNPAY link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Lb9QwELbQ9gAcyhsCBZnHgYsbx68kJ9RFrRaqVhx21XIKfiSw6ipZ7QNUfj3jxBt1oUhIHHJIPI4m8dj-Zuz5jNAbzzmnjZVEWsmIcNKS3KYlAfDBnXaZFYlPFD45VaOJ-Hguz8M5p8uwrRJc8Wk7SPssLAIzGI0Zi9PYs2nFc1e9-x5CSQD1MyEF99nkO0oCGB-gncnpp4PPbU5RqNzxCXFw7uMl3Kb-NVuzUEvWfx3C_HOj5M11PdeXP_RsdmUWOrqDvmz07zafXOyvV2bf_vyN2vE_PvAu2g0IFR90JnUP3Sjr--j2Fd7CB2gybNwlOWsWNf5wMiFDmAkdbpcD8Gg6x7p2-BiE8TFUaSlhl_gQhpIuSxJ3mZF4DHDV-UOP8Jme-YD9QzQ-Ohy_H5FwPgOxkssVqahynGrOTKI0l9xaRa2yVQkQzSpHRVpRalNeZjaptBGUg7irHIhliTT8ERrUTV0-QVhSw3QOvia4o8IalcFVJlZb44RkVkTo7aa5Chu4y_0RGrMCfBjfskXfshF61YvOO8KO64SGvs17Ac-x3T5oFl-L0GULcASZ0JXSeaUF6GPSXIEuXJvSwNDsIrS3sZgidPxlAfgyb6lWkwi97Iuhy_p1GF2XzbqTkTl4tixCjzsD6zXxYTj4OXmE0i3T21J1u6SefmtpwX1MmlOo-bo30r__gaf_JPUM3WI-3YNywtQeGqwW6_I5gLCVeRE62i9RbCt0 priority: 102 providerName: Unpaywall |
| Title | Body-Worn IMU-Based Human Hip and Knee Kinematics Estimation during Treadmill Walking |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/35408159 https://www.proquest.com/docview/2649091391 https://www.proquest.com/docview/2649591402 https://pubmed.ncbi.nlm.nih.gov/PMC9003309 https://www.mdpi.com/1424-8220/22/7/2544/pdf?version=1648454307 https://doaj.org/article/96624af6a9fa4b6eb7962c43abeb887d |
| UnpaywallVersion | publishedVersion |
| Volume | 22 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVFSB databaseName: Free Full-Text Journals in Chemistry customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: HH5 dateStart: 20010101 isFulltext: true titleUrlDefault: http://abc-chemistry.org/ providerName: ABC ChemistRy – providerCode: PRVAFT databaseName: Open Access Digital Library customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: KQ8 dateStart: 20010101 isFulltext: true titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html providerName: Colorado Alliance of Research Libraries – providerCode: PRVAFT databaseName: Open Access Digital Library customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: KQ8 dateStart: 20030101 isFulltext: true titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html providerName: Colorado Alliance of Research Libraries – providerCode: PRVAON databaseName: DOAJ Directory of Open Access Journals customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: DOA dateStart: 20010101 isFulltext: true titleUrlDefault: https://www.doaj.org/ providerName: Directory of Open Access Journals – providerCode: PRVEBS databaseName: EBSCOhost Academic Search Ultimate customDbUrl: https://search.ebscohost.com/login.aspx?authtype=ip,shib&custid=s3936755&profile=ehost&defaultdb=asn eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: ABDBF dateStart: 20081201 isFulltext: true titleUrlDefault: https://search.ebscohost.com/direct.asp?db=asn providerName: EBSCOhost – providerCode: PRVEBS databaseName: Inspec with Full Text customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: ADMLS dateStart: 20081201 isFulltext: true titleUrlDefault: https://www.ebsco.com/products/research-databases/inspec-full-text providerName: EBSCOhost – providerCode: PRVFQY databaseName: GFMER Free Medical Journals customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: GX1 dateStart: 20010101 isFulltext: true titleUrlDefault: http://www.gfmer.ch/Medical_journals/Free_medical.php providerName: Geneva Foundation for Medical Education and Research – providerCode: PRVFQY databaseName: GFMER Free Medical Journals customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: GX1 dateStart: 0 isFulltext: true titleUrlDefault: http://www.gfmer.ch/Medical_journals/Free_medical.php providerName: Geneva Foundation for Medical Education and Research – providerCode: PRVHPJ databaseName: ROAD: Directory of Open Access Scholarly Resources customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: M~E dateStart: 20010101 isFulltext: true titleUrlDefault: https://road.issn.org providerName: ISSN International Centre – providerCode: PRVAQN databaseName: PubMed Central customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: RPM dateStart: 20030101 isFulltext: true titleUrlDefault: https://www.ncbi.nlm.nih.gov/pmc/ providerName: National Library of Medicine – providerCode: PRVPQU databaseName: Health & Medical Collection customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: 7X7 dateStart: 20010101 isFulltext: true titleUrlDefault: https://search.proquest.com/healthcomplete providerName: ProQuest – providerCode: PRVPQU databaseName: ProQuest Central customDbUrl: http://www.proquest.com/pqcentral?accountid=15518 eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: BENPR dateStart: 20010101 isFulltext: true titleUrlDefault: https://www.proquest.com/central providerName: ProQuest – providerCode: PRVPQU databaseName: ProQuest Technology Collection customDbUrl: eissn: 1424-8220 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: 8FG dateStart: 20010101 isFulltext: true titleUrlDefault: https://search.proquest.com/technologycollection1 providerName: ProQuest – providerCode: PRVFZP databaseName: Scholars Portal Journals: Open Access customDbUrl: eissn: 1424-8220 dateEnd: 20250930 omitProxy: true ssIdentifier: ssj0023338 issn: 1424-8220 databaseCode: M48 dateStart: 20030101 isFulltext: true titleUrlDefault: http://journals.scholarsportal.info providerName: Scholars Portal |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV1Lj9MwEB7t4wAcEG8CS2UeQlwMjh9Jc0Boi1oKq1Yr1Gq7p8iPBFaq0m4fgv57xkkabUXhkByccTQae-L5xvE3AG8855w2VlFlFafSKUsTG2cUgw_htGtbGfqDwoNh1B_LbxM1OYDtb821AZd7oZ2vJzVeTN__vt58Qof_6BEnQvYPS85Z7Km23s6vqa8n5fdd6-Iah3CMa1biizoMZLO_wAUis4pnaPcNO6tTSeK_L_L8-wfKW-tirje_9HR6Y3Xq3YO7dVhJTqt5cB8OsuIB3LlBNvgQxp2Z29CL2aIgXwdj2sHly5Eyh0_6V3OiC0fOUJicYZeSx3VJuuj_1dFGUh1nJCOMMZ2vVEQu9NRn2R_BqNcdfe7TuqgCtUqoFc1Z5ATTgpsw0kIJayNmI5tnGFfZyDEZ54zZWGRtG-baSCZQ3OUOxdqhMuIxHBWzInsKRDHDdYIAETGktCZq45WFVlvjpOJWBvBua8vU1oTjvu7FNEXg4c2eNmYP4FUjOq9YNvYJdfyANAKeGLtsmC1-pLWfpYjeuNR5pJNcS9THxEmEughtMoPfUxfAyXY40-1kSzEoTEp-1DCAl81j9DO_eaKLbLauZFSCcJQH8KQa_UYTnztD4yQBxDvzYkfV3SfF1c-Sy9snkgXDnq-bGfRvCzz7v_LP4Tb3hzOYoDw6gaPVYp29wJBpZVpwGE9ivLd7X1pw3OkOz7-3yvRDq_QLbBsPz08v_wCj4Ry9 |
| linkProvider | Scholars Portal |
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9NAEB6Vcig9IN4YCiwvicuq633Y8QEhAq0S0vSUqLlZ-7ChUmSneajKj-I_Mms7biMKtx58sWet0ezM7MzuzjcAHzzmnDZWUWUVp9IpSxMbZxSDD-G061gZ-kLh4WnUG8sfEzXZgd-bWhh_rXLjEytH7Urr98gPceFOKgzL8MvsgvquUf50ddNCo1aLQba-xJRt8bn_Hef3I-fHR6NvPdp0FaBWCbWkOYucYFpwE0ZaKGFtxGxk8wwDCxs5JuOcMRuLrGPDXBvJBJK73CFZJ1RG4G_vwF0p0JWg-cSTq_xOYLpXgxcJkbDDBecs9ghgW0te1RngpnD271uZe6tipteXejq9tuQdP4D7TaxKvtbK9RB2suIR7F9DMHwM427p1vSsnBekPxzTLq6JjlQHA6R3PiO6cGSAxGSAQypw2AU5QqdS10uSukaSjDBwdb79ETnTU791_wRGtyHTp7BblEX2HIhihusEs05MTKU1UQefLLTaGicVtzKATxtZprZBMffNNKYpZjNe7Gkr9gDetaSzGrrjJqKun5CWwKNtVy_K-c-0Md4UU0IudR7pJNcS-TFxEiEvQpvMoJN2ARxspjNtXMAivVLYAN62n9F4_YmMLrJyVdOoBHNcHsCzevZbTvyGHAonCSDe0ostVre_FOe_KoBwvzstGI5832rQvyXw4v_Mv4G93mh4kp70Twcv4R731R9MUB4dwO5yvspeYUy2NK8rSyCQ3rLl_QFTgkpf |
| linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9swDCa6DtjjMOxdb92mvYBehMiSZceHYVjWBsmyFjskaG6GHvZaILCzPFDkp-3fjfKrDdbt1oMvFm0QFEmRkvgR4IPDnFPaSCqN5DSw0tDYRCnF4ENYZbsm8F2h8PFJOJgE36ZyugO_m1oYd62y8Ymlo7aFcXvkHVy44xLD0u9k9bWIH4f9z_Nf1HWQcietTTuNSkVG6eYC07flp-EhzvVHzvtH468DWncYoEYKuaIZC61gSnDth0pIYUzITGiyFIMME1oWRBljJhJp1_iZ0gETSG4zi2RdX2qBv70FtyMhYnebMJpe5noCU78KyAgHWWfJOYscGtjW8ld2CbgutP37hubddT5Xmws1m11Z_voP4UEdt5IvlaI9gp00fwz3r6AZPoFJr7AbeloscjI8ntAero-WlIcEZHA-Jyq3ZITEZISflECxS3KEDqaqnSRVvSQZYxBrXSskcqpmbhv_KYxvQqbPYDcv8nQPiGSaqxgzUExSA6PDLj6pb5TRNpDcBB4cNLJMTI1o7hprzBLMbJzYk1bsHrxrSecVjMd1RD03IS2BQ94uXxSLn0ltyAmmhzxQWajiTAXIj47iEHkRSqcaHbb1YL-ZzqR2B8vkUnk9eNsOoyG70xmVp8W6opEx5rvcg-fV7LecuM05FE7sQbSlF1usbo_k52clWLjbqRYMv3zfatC_JfDi_8y_gTtoc8n34cnoJdzjrhCECcrDfdhdLdbpKwzPVvp1aQgEkhs2vD_GkE6i |
| linkToUnpaywall | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Lb9QwELbQ9gAcyhsCBZnHgYsbx68kJ9RFrRaqVhx21XIKfiSw6ipZ7QNUfj3jxBt1oUhIHHJIPI4m8dj-Zuz5jNAbzzmnjZVEWsmIcNKS3KYlAfDBnXaZFYlPFD45VaOJ-Hguz8M5p8uwrRJc8Wk7SPssLAIzGI0Zi9PYs2nFc1e9-x5CSQD1MyEF99nkO0oCGB-gncnpp4PPbU5RqNzxCXFw7uMl3Kb-NVuzUEvWfx3C_HOj5M11PdeXP_RsdmUWOrqDvmz07zafXOyvV2bf_vyN2vE_PvAu2g0IFR90JnUP3Sjr--j2Fd7CB2gybNwlOWsWNf5wMiFDmAkdbpcD8Gg6x7p2-BiE8TFUaSlhl_gQhpIuSxJ3mZF4DHDV-UOP8Jme-YD9QzQ-Ohy_H5FwPgOxkssVqahynGrOTKI0l9xaRa2yVQkQzSpHRVpRalNeZjaptBGUg7irHIhliTT8ERrUTV0-QVhSw3QOvia4o8IalcFVJlZb44RkVkTo7aa5Chu4y_0RGrMCfBjfskXfshF61YvOO8KO64SGvs17Ac-x3T5oFl-L0GULcASZ0JXSeaUF6GPSXIEuXJvSwNDsIrS3sZgidPxlAfgyb6lWkwi97Iuhy_p1GF2XzbqTkTl4tixCjzsD6zXxYTj4OXmE0i3T21J1u6SefmtpwX1MmlOo-bo30r__gaf_JPUM3WI-3YNywtQeGqwW6_I5gLCVeRE62i9RbCt0 |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Body-Worn+IMU-Based+Human+Hip+and+Knee+Kinematics+Estimation+during+Treadmill+Walking&rft.jtitle=Sensors+%28Basel%2C+Switzerland%29&rft.au=McGrath%2C+Timothy&rft.au=Stirling%2C+Leia&rft.date=2022-03-26&rft.pub=MDPI+AG&rft.eissn=1424-8220&rft.volume=22&rft.issue=7&rft.spage=2544&rft_id=info:doi/10.3390%2Fs22072544&rft.externalDBID=HAS_PDF_LINK |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1424-8220&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1424-8220&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1424-8220&client=summon |