Three-Tesla Magnetic Resonance Imaging of Patients With Deep Brain Stimulators: Results From a Phantom Study and a Pilot Study in Patients

Abstract BACKGROUND Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients wit...

Full description

Saved in:
Bibliographic Details
Published inNeurosurgery Vol. 88; no. 2; pp. 349 - 355
Main Authors Davidson, Benjamin, Tam, Fred, Yang, Benson, Meng, Ying, Hamani, Clement, Graham, Simon J, Lipsman, Nir
Format Journal Article
LanguageEnglish
Published United States Oxford University Press 01.02.2021
Wolters Kluwer Health, Inc
Subjects
Online AccessGet full text
ISSN0148-396X
1524-4040
1081-1281
1524-4040
DOI10.1093/neuros/nyaa439

Cover

Abstract Abstract BACKGROUND Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients with DBS devices in place because of safety concerns. 3T MRI could be used not only for structural imaging, but also for functional MRI to study the effects of DBS on neurocircuitry and optimize programming. OBJECTIVE To use an anthropomorphic phantom design to perform temperature and voltage safety testing on an activated DBS device during 3T imaging. METHODS An anthropomorphic 3D-printed human phantom was constructed and used to perform temperature and voltage testing on a DBS device during 3T MRI. Based on the phantom assessment, a cohort study was conducted in which 6 human patients underwent MRI with their DBS device in an activated (ON) state. RESULTS During the phantom study, temperature rises were under 2°C during all sequences, with the DBS in both the deactivated and activated states. Radiofrequency pulses from the MRI appeared to modulate the electrical discharge from the DBS, resulting in slight fluctuations of voltage amplitude. Six human subjects underwent MRI with their DBS in an activated state without any serious adverse events. One patient experienced stimulation-related side effects during T1-MPRAGE scanning with the DBS in an ON state because of radiofrequency-induced modulation of voltage amplitude. CONCLUSION Following careful phantom-based safety testing, 3T structural and functional MRI can be safely performed in subjects with activated deep brain stimulators.
AbstractList Abstract BACKGROUND Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients with DBS devices in place because of safety concerns. 3T MRI could be used not only for structural imaging, but also for functional MRI to study the effects of DBS on neurocircuitry and optimize programming. OBJECTIVE To use an anthropomorphic phantom design to perform temperature and voltage safety testing on an activated DBS device during 3T imaging. METHODS An anthropomorphic 3D-printed human phantom was constructed and used to perform temperature and voltage testing on a DBS device during 3T MRI. Based on the phantom assessment, a cohort study was conducted in which 6 human patients underwent MRI with their DBS device in an activated (ON) state. RESULTS During the phantom study, temperature rises were under 2°C during all sequences, with the DBS in both the deactivated and activated states. Radiofrequency pulses from the MRI appeared to modulate the electrical discharge from the DBS, resulting in slight fluctuations of voltage amplitude. Six human subjects underwent MRI with their DBS in an activated state without any serious adverse events. One patient experienced stimulation-related side effects during T1-MPRAGE scanning with the DBS in an ON state because of radiofrequency-induced modulation of voltage amplitude. CONCLUSION Following careful phantom-based safety testing, 3T structural and functional MRI can be safely performed in subjects with activated deep brain stimulators.
BACKGROUND: Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients with DBS devices in place because of safety concerns. 3T MRI could be used not only for structural imaging, but also for functional MRI to study the effects of DBS on neurocircuitry and optimize programming. OBJECTIVE: To use an anthropomorphic phantom design to perform temperature and voltage safety testing on an activated DBS device during 3T imaging. METHODS: An anthropomorphic 3D-printed human phantom was constructed and used to perform temperature and voltage testing on a DBS device during 3T MRI. Based on the phantom assessment, a cohort study was conducted in which 6 human patients underwent MRI with their DBS device in an activated (ON) state. RESULTS: During the phantom study, temperature rises were under 2[degrees]C during all sequences, with the DBS in both the deactivated and activated states. Radiofrequency pulses from the MRI appeared to modulate the electrical discharge from the DBS, resulting in slight fluctuations of voltage amplitude. Six human subjects underwent MRI with their DBS in an activated state without any serious adverse events. One patient experienced stimulation-related side effects during T1-MPRAGE scanning with the DBS in an ON state because of radiofrequency-induced modulation of voltage amplitude. CONCLUSION: Following careful phantom-based safety testing, 3T structural and functional MRI can be safely performed in subjects with activated deep brain stimulators. KEY WORDS: Deep brain stimulation, Magnetic resonance imaging, Phantom, Psychiatric surgery, Radiofrequency heating
Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients with DBS devices in place because of safety concerns. 3T MRI could be used not only for structural imaging, but also for functional MRI to study the effects of DBS on neurocircuitry and optimize programming. To use an anthropomorphic phantom design to perform temperature and voltage safety testing on an activated DBS device during 3T imaging. An anthropomorphic 3D-printed human phantom was constructed and used to perform temperature and voltage testing on a DBS device during 3T MRI. Based on the phantom assessment, a cohort study was conducted in which 6 human patients underwent MRI with their DBS device in an activated (ON) state. During the phantom study, temperature rises were under 2°C during all sequences, with the DBS in both the deactivated and activated states. Radiofrequency pulses from the MRI appeared to modulate the electrical discharge from the DBS, resulting in slight fluctuations of voltage amplitude. Six human subjects underwent MRI with their DBS in an activated state without any serious adverse events. One patient experienced stimulation-related side effects during T1-MPRAGE scanning with the DBS in an ON state because of radiofrequency-induced modulation of voltage amplitude. Following careful phantom-based safety testing, 3T structural and functional MRI can be safely performed in subjects with activated deep brain stimulators.
BACKGROUND Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients with DBS devices in place because of safety concerns. 3T MRI could be used not only for structural imaging, but also for functional MRI to study the effects of DBS on neurocircuitry and optimize programming. OBJECTIVE To use an anthropomorphic phantom design to perform temperature and voltage safety testing on an activated DBS device during 3T imaging. METHODS An anthropomorphic 3D-printed human phantom was constructed and used to perform temperature and voltage testing on a DBS device during 3T MRI. Based on the phantom assessment, a cohort study was conducted in which 6 human patients underwent MRI with their DBS device in an activated (ON) state. RESULTS During the phantom study, temperature rises were under 2°C during all sequences, with the DBS in both the deactivated and activated states. Radiofrequency pulses from the MRI appeared to modulate the electrical discharge from the DBS, resulting in slight fluctuations of voltage amplitude. Six human subjects underwent MRI with their DBS in an activated state without any serious adverse events. One patient experienced stimulation-related side effects during T1-MPRAGE scanning with the DBS in an ON state because of radiofrequency-induced modulation of voltage amplitude. CONCLUSION Following careful phantom-based safety testing, 3T structural and functional MRI can be safely performed in subjects with activated deep brain stimulators.
Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients with DBS devices in place because of safety concerns. 3T MRI could be used not only for structural imaging, but also for functional MRI to study the effects of DBS on neurocircuitry and optimize programming.BACKGROUNDDeep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has become the gold-standard modality for structural and functional imaging, most centers refrain from 3T imaging in patients with DBS devices in place because of safety concerns. 3T MRI could be used not only for structural imaging, but also for functional MRI to study the effects of DBS on neurocircuitry and optimize programming.To use an anthropomorphic phantom design to perform temperature and voltage safety testing on an activated DBS device during 3T imaging.OBJECTIVETo use an anthropomorphic phantom design to perform temperature and voltage safety testing on an activated DBS device during 3T imaging.An anthropomorphic 3D-printed human phantom was constructed and used to perform temperature and voltage testing on a DBS device during 3T MRI. Based on the phantom assessment, a cohort study was conducted in which 6 human patients underwent MRI with their DBS device in an activated (ON) state.METHODSAn anthropomorphic 3D-printed human phantom was constructed and used to perform temperature and voltage testing on a DBS device during 3T MRI. Based on the phantom assessment, a cohort study was conducted in which 6 human patients underwent MRI with their DBS device in an activated (ON) state.During the phantom study, temperature rises were under 2°C during all sequences, with the DBS in both the deactivated and activated states. Radiofrequency pulses from the MRI appeared to modulate the electrical discharge from the DBS, resulting in slight fluctuations of voltage amplitude. Six human subjects underwent MRI with their DBS in an activated state without any serious adverse events. One patient experienced stimulation-related side effects during T1-MPRAGE scanning with the DBS in an ON state because of radiofrequency-induced modulation of voltage amplitude.RESULTSDuring the phantom study, temperature rises were under 2°C during all sequences, with the DBS in both the deactivated and activated states. Radiofrequency pulses from the MRI appeared to modulate the electrical discharge from the DBS, resulting in slight fluctuations of voltage amplitude. Six human subjects underwent MRI with their DBS in an activated state without any serious adverse events. One patient experienced stimulation-related side effects during T1-MPRAGE scanning with the DBS in an ON state because of radiofrequency-induced modulation of voltage amplitude.Following careful phantom-based safety testing, 3T structural and functional MRI can be safely performed in subjects with activated deep brain stimulators.CONCLUSIONFollowing careful phantom-based safety testing, 3T structural and functional MRI can be safely performed in subjects with activated deep brain stimulators.
Audience Academic
Author Meng, Ying
Yang, Benson
Graham, Simon J
Tam, Fred
Davidson, Benjamin
Hamani, Clement
Lipsman, Nir
Author_xml – sequence: 1
  givenname: Benjamin
  surname: Davidson
  fullname: Davidson, Benjamin
– sequence: 2
  givenname: Fred
  surname: Tam
  fullname: Tam, Fred
– sequence: 3
  givenname: Benson
  surname: Yang
  fullname: Yang, Benson
– sequence: 4
  givenname: Ying
  surname: Meng
  fullname: Meng, Ying
– sequence: 5
  givenname: Clement
  surname: Hamani
  fullname: Hamani, Clement
– sequence: 6
  givenname: Simon J
  surname: Graham
  fullname: Graham, Simon J
– sequence: 7
  givenname: Nir
  surname: Lipsman
  fullname: Lipsman, Nir
  email: nir.lipsman@sunnybrook.ca
BackLink https://www.ncbi.nlm.nih.gov/pubmed/33045736$$D View this record in MEDLINE/PubMed
BookMark eNqFkl9PFDEUxRuDkQV99dE08UUfhu1MO_98IEEQJcFIZI2-NXc7d3ZLOu067WD2K_ip7WQXEKIhfWhze36nvafdIzvWWSTkZcoOUlbzqcWhd35q1wCC10_IJM0zkQgm2A6ZsFRUCa-LH7tkz_srxtJClNUzsss5E3nJiwn5PVv2iMkMvQH6GRYWg1b0K3pnwSqkZx0stF1Q19ILCBpt8PS7Dkt6grii73vQll4G3Q0Gguv9uxEdTBSd9q6jQC-WYENcXYahWVOwzVjTxoVtJeI3vs_J0xaMxxfbeZ98O_0wO_6UnH_5eHZ8dJ6oPK1DgsDLtslZC02WNyVgPQfVNhkv2qZgVZXlvEgrDkrN83nJGeQCq3queN2iEmXB98l04zvYFax_gTFy1esO-rVMmRxTlZtU5TbVSBxuiNUw77BR8bY93FEOtLy_Y_VSLty1LCvGBc-iwZutQe9-DuiD7LRXaAxYdIOXmchZIaoyE1H6-oH0yg29jYFEVVkVLBexw1vVAgxKbVsXz1WjqTwqymx85pxF1cE_VHE02GkVP1KrY_0e8OrvRm87vPkvd44q5uN7bB-PTjwAlA7xwd0YlDb_x95uMDesHjviD2z19-A
CitedBy_id crossref_primary_10_1109_LEMCPA_2022_3180974
crossref_primary_10_4028_p_b6Ix0E
crossref_primary_10_1007_s40430_025_05450_y
crossref_primary_10_1016_j_brs_2022_03_009
crossref_primary_10_1002_mp_16603
crossref_primary_10_1016_j_jocn_2024_110954
crossref_primary_10_1097_ACO_0000000000001296
crossref_primary_10_1002_mrm_28968
crossref_primary_10_1159_000525538
crossref_primary_10_1038_s41380_022_01677_6
crossref_primary_10_1017_cjn_2025_29
crossref_primary_10_1371_journal_pone_0316002
crossref_primary_10_1002_mrm_28818
Cites_doi 10.1007/s11910-019-0961-8
10.1227/01.NEU.0000186935.87971.2a
10.3171/2018.11.JNS181338
10.1088/0031-9155/57/17/5651
10.1002/mp.14214
10.1097/WCO.0000000000000679
10.1002/mrm.26535
10.3171/2016.9.JNS16908
10.1016/j.neuroimage.2018.09.034
10.1111/j.1540-8159.1992.tb02904.x
10.1088/0031-9155/50/18/001
10.1002/jmri.20103
10.3171/jns.2003.99.4.0772
10.1016/j.neuroimage.2007.04.058
10.1002/jmri.10069
10.1093/brain/awz239
10.1016/j.mri.2005.02.007
10.1016/j.brs.2019.11.008
10.1161/CIRCULATIONAHA.105.597013
10.1080/10976640600897237
ContentType Journal Article
Copyright Copyright © 2020 by the Congress of Neurological Surgeons 2020
Copyright © 2020 by the Congress of Neurological Surgeons.
COPYRIGHT 2021 Oxford University Press
Copyright © 2020 by the Congress of Neurological Surgeons
Copyright_xml – notice: Copyright © 2020 by the Congress of Neurological Surgeons 2020
– notice: Copyright © 2020 by the Congress of Neurological Surgeons.
– notice: COPYRIGHT 2021 Oxford University Press
– notice: Copyright © 2020 by the Congress of Neurological Surgeons
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
3V.
7X7
7XB
88E
8FI
8FJ
8FK
ABUWG
AFKRA
BENPR
CCPQU
FYUFA
GHDGH
K9.
M0S
M1P
PHGZM
PHGZT
PJZUB
PKEHL
PPXIY
PQEST
PQQKQ
PQUKI
PRINS
7X8
5PM
ADTOC
UNPAY
DOI 10.1093/neuros/nyaa439
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
ProQuest Central (Corporate)
Health & Medical Collection
ProQuest Central (purchase pre-March 2016)
Medical Database (Alumni Edition)
Hospital Premium Collection
Hospital Premium Collection (Alumni Edition)
ProQuest Central (Alumni) (purchase pre-March 2016)
ProQuest Central (Alumni Edition)
ProQuest Central UK/Ireland
ProQuest Central
ProQuest One Community College
Health Research Premium Collection
Health Research Premium Collection (Alumni)
ProQuest Health & Medical Complete (Alumni)
Health & Medical Collection (Alumni Edition)
Medical Database
ProQuest Central Premium
ProQuest One Academic (New)
ProQuest Health & Medical Research Collection
ProQuest One Academic Middle East (New)
ProQuest One Health & Nursing
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Academic
ProQuest One Academic UKI Edition
ProQuest Central China
MEDLINE - Academic
PubMed Central (Full Participant titles)
Unpaywall for CDI: Periodical Content
Unpaywall
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
ProQuest One Academic Middle East (New)
ProQuest One Academic Eastern Edition
ProQuest Health & Medical Complete (Alumni)
ProQuest Central (Alumni Edition)
ProQuest One Community College
ProQuest One Health & Nursing
ProQuest Hospital Collection
Health Research Premium Collection (Alumni)
ProQuest Central China
ProQuest Hospital Collection (Alumni)
ProQuest Central
ProQuest Health & Medical Complete
ProQuest Health & Medical Research Collection
Health Research Premium Collection
ProQuest Medical Library
ProQuest One Academic UKI Edition
Health and Medicine Complete (Alumni Edition)
Health & Medical Research Collection
ProQuest Central (New)
ProQuest One Academic
ProQuest One Academic (New)
ProQuest Medical Library (Alumni)
ProQuest Central (Alumni)
MEDLINE - Academic
DatabaseTitleList

MEDLINE
ProQuest One Academic Middle East (New)
MEDLINE - Academic
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 3
  dbid: UNPAY
  name: Unpaywall
  url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/
  sourceTypes: Open Access Repository
– sequence: 4
  dbid: BENPR
  name: ProQuest Central
  url: http://www.proquest.com/pqcentral?accountid=15518
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
EISSN 1524-4040
EndPage 355
ExternalDocumentID oai:pubmedcentral.nih.gov:7803432
PMC7803432
A672647850
33045736
10_1093_neuros_nyaa439
10.1093/neuros/nyaa439
Genre Research Support, Non-U.S. Gov't
Journal Article
GeographicLocations Canada
GeographicLocations_xml – name: Canada
GrantInformation_xml – fundername: CIHR
– fundername: ; ;
GroupedDBID ---
.-D
.3C
.55
.GJ
.Z2
01R
0R~
123
1TH
354
3O-
3V.
40H
48X
4Q1
4Q2
4Q3
53G
5RE
5VS
71W
77Y
7O~
7X7
88E
8FI
8FJ
A9M
AAAAV
AAAXR
AAGIX
AAHPQ
AAIQE
AAJQQ
AAKAS
AAPQZ
AAQKA
AAQOH
AAQQT
AARTV
AASCR
AASOK
AASXQ
AAUQX
AAVAP
AAYEP
ABASU
ABDIG
ABHFT
ABJNI
ABLJU
ABOCM
ABPPZ
ABPTD
ABSAR
ABUWG
ABZAD
ACDDN
ACFRR
ACGFO
ACGFS
ACILI
ACOAL
ACUTJ
ACWRI
ACXJB
ACXNZ
ADBBV
ADBIZ
ADFPA
ADGZP
ADHKW
ADHPY
ADRTK
ADZCM
AE3
AE6
AEETU
AEMDU
AENEX
AENZO
AETBJ
AEWNT
AFDTB
AFFZL
AFKRA
AFOFC
AFTRI
AFUWQ
AGINI
AGINJ
AGKRT
AHMBA
AHOMT
AHQNM
AHRYX
AHVBC
AIZYK
AJNWD
AJNYG
AJZMW
ALIPV
ALMA_UNASSIGNED_HOLDINGS
AMNEI
APIBT
AQDSO
AQKUS
ASAOO
ATDFG
AWKKM
BAYMD
BCRHZ
BENPR
BOYCO
BPHCQ
BS7
BTRTY
BVXVI
BYPQX
C45
CCPQU
CDBKE
CS3
DAKXR
E.X
EBS
EEVPB
EIHJH
EJD
ELUNK
ENERS
ERAAH
EX3
F2K
F2L
F2M
F2N
F5P
FCALG
FECEO
FL-
FLUFQ
FOEOM
FOTVD
FQBLK
FW0
FYUFA
GAUVT
GJXCC
H0~
H13
HLJTE
HMCUK
HZ~
IAO
IHR
INH
INR
IN~
IPNFZ
J5H
JF7
JF9
JG8
JK3
JK8
K8S
KD2
KMI
KOP
KSI
KSN
L-C
L7B
LMP
M18
M1P
MBLQV
MBTAY
MHKGH
N4W
N9A
NOYVH
NVLIB
N~7
N~B
N~M
O9-
OAG
OAH
OBH
OCUKA
ODA
ODMLO
OHH
OL1
OLB
OLG
OLH
OLU
OLV
OLY
OLZ
ORVUJ
OVD
OWU
OWV
OWW
OWX
OWY
OWZ
P-K
P2P
PAFKI
PEELM
PQQKQ
PROAC
PSQYO
R58
RIG
RLZ
ROX
ROZ
RUSNO
RXW
S4R
SJN
TEORI
TJX
UKHRP
V2I
VVN
W3M
WOQ
WOW
X3V
X3W
X7M
XXN
XYM
YAYTL
YCJ
YFH
YKOAZ
YOC
YXANX
ZCG
ZFV
ZGI
ZXP
ZY1
AAPXW
AAYXX
ABPXF
ABZZY
ACLDA
ACZKN
ADKSD
ADSXY
AFBFQ
AJCLO
AKCTQ
ALKUP
AOQMC
APJGH
CITATION
JXSIZ
PHGZM
PHGZT
PJZUB
PPXIY
PUEGO
ACIJW
CGR
CUY
CVF
ECM
EIF
NPM
PMFND
7XB
8FK
K9.
PKEHL
PQEST
PQUKI
PRINS
7X8
5PM
ADTOC
UNPAY
ID FETCH-LOGICAL-c519t-ea37fd50fad25d7ae9bacfd236fd60882536183accb5b730a54e89bc39fec4763
IEDL.DBID UNPAY
ISSN 0148-396X
1524-4040
1081-1281
IngestDate Tue Aug 19 23:59:49 EDT 2025
Tue Sep 30 17:00:52 EDT 2025
Sun Sep 28 09:46:08 EDT 2025
Fri Sep 19 20:54:11 EDT 2025
Tue Jun 17 21:23:36 EDT 2025
Tue Jun 10 20:28:55 EDT 2025
Wed Feb 19 02:28:05 EST 2025
Wed Oct 01 02:34:15 EDT 2025
Thu Apr 24 22:57:47 EDT 2025
Wed Aug 28 03:19:51 EDT 2024
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 2
Keywords Phantom
Radiofrequency heating
Magnetic resonance imaging
Deep brain stimulation
Psychiatric surgery
Language English
License This article is published and distributed under the terms of the Oxford University Press, Standard Journals Publication Model (https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model)
https://academic.oup.com/journals/pages/open_access/funder_policies/chorus/standard_publication_model
Copyright © 2020 by the Congress of Neurological Surgeons.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c519t-ea37fd50fad25d7ae9bacfd236fd60882536183accb5b730a54e89bc39fec4763
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
OpenAccessLink https://proxy.k.utb.cz/login?url=https://www.ncbi.nlm.nih.gov/pmc/articles/7803432
PMID 33045736
PQID 2478605425
PQPubID 2046368
PageCount 7
ParticipantIDs unpaywall_primary_10_1093_neuros_nyaa439
pubmedcentral_primary_oai_pubmedcentral_nih_gov_7803432
proquest_miscellaneous_2450648724
proquest_journals_2478605425
gale_infotracmisc_A672647850
gale_infotracacademiconefile_A672647850
pubmed_primary_33045736
crossref_primary_10_1093_neuros_nyaa439
crossref_citationtrail_10_1093_neuros_nyaa439
oup_primary_10_1093_neuros_nyaa439
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2021-02-01
PublicationDateYYYYMMDD 2021-02-01
PublicationDate_xml – month: 02
  year: 2021
  text: 2021-02-01
  day: 01
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
– name: Philadelphia
PublicationTitle Neurosurgery
PublicationTitleAlternate Neurosurgery
PublicationYear 2021
Publisher Oxford University Press
Wolters Kluwer Health, Inc
Publisher_xml – name: Oxford University Press
– name: Wolters Kluwer Health, Inc
References Golestanirad (bib11-20231012) 2017; 78
Horn (bib3-20231012) 2019; 142
Carmichael (bib18-20231012) 2007; 37
Boutet (bib4-20231012) 2019; 19
Golestanirad (bib12-20231012) 2019; 184
Rezai (bib8-20231012) 2005; 57
Spiegel (bib10-20231012) 2003; 99
Bhidayasiri (bib17-20231012) 2005; 23
Gleason (bib7-20231012) 1992; 15
Baker (bib22-20231012) 2004; 20
Harmsen (bib1-20231012) 2020; 13
Shrivastava (bib23-20231012) 2012; 57
Boutet (bib16-20231012) 2019; 132
Shellock (bib13-20231012) 2007; 9
Boutet (bib19-20231012)
Yang (bib20-20231012) 2020; 47
Horn (bib2-20231012) 2019; 32
Lazebnik (bib21-20231012) 2005; 50
Rezai (bib9-20231012) 2002; 15
Sammartino (bib15-20231012) 2017; 127
Sommer (bib14-20231012) 2006; 114
References_xml – volume: 19
  start-page: 42
  issue: 7
  year: 2019
  ident: bib4-20231012
  article-title: Neuroimaging technological advancements for targeting in functional neurosurgery
  publication-title: Curr Neurol Neurosci Rep
  doi: 10.1007/s11910-019-0961-8
– volume: 57
  start-page: 1056
  issue: 5
  year: 2005
  ident: bib8-20231012
  article-title: Is magnetic resonance imaging safe for patients with neurostimulation systems used for deep brain stimulation
  publication-title: Neurosurgery
  doi: 10.1227/01.NEU.0000186935.87971.2a
– volume: 132
  start-page: 586
  issue: 2
  year: 2019
  ident: bib16-20231012
  article-title: 3-Tesla MRI of deep brain stimulation patients: safety assessment of coils and pulse sequences
  publication-title: J Neurosurg
  doi: 10.3171/2018.11.JNS181338
– ident: bib19-20231012
  article-title: Safety assessment of spine MRI in deep brain stimulation patients
  publication-title: J Neurosurg Spine
– volume: 57
  start-page: 5651
  issue: 17
  year: 2012
  ident: bib23-20231012
  article-title: Heating induced near deep brain stimulation lead electrodes during magnetic resonance imaging with a 3 t transceive volume head coil
  publication-title: Phys Med Biol
  doi: 10.1088/0031-9155/57/17/5651
– volume: 47
  start-page: 745
  issue: 8
  year: 2020
  ident: bib20-20231012
  article-title: Technical note: an anthropomorphic phantom with implanted neurostimulator for investigation of MRI safety
  publication-title: Med Phys
  doi: 10.1002/mp.14214
– volume: 32
  start-page: 511
  issue: 4
  year: 2019
  ident: bib2-20231012
  article-title: The impact of modern-day neuroimaging on the field of deep brain stimulation
  publication-title: Curr Opin Neurol
  doi: 10.1097/WCO.0000000000000679
– volume: 78
  start-page: 1558
  issue: 4
  year: 2017
  ident: bib11-20231012
  article-title: Local SAR near deep brain stimulation (DBS) electrodes at 64 and 127 MHz: a simulation study of the effect of extracranial loops
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.26535
– volume: 127
  start-page: 892
  issue: 4
  year: 2017
  ident: bib15-20231012
  article-title: 3-Tesla MRI in patients with fully implanted deep brain stimulation devices: a preliminary study in 10 patients
  publication-title: J Neurosurg
  doi: 10.3171/2016.9.JNS16908
– volume: 184
  start-page: 566
  year: 2019
  ident: bib12-20231012
  article-title: RF-induced heating in tissue near bilateral DBS implants during MRI at 1.5T and 3T: the role of surgical lead management
  publication-title: Neuroimage
  doi: 10.1016/j.neuroimage.2018.09.034
– volume: 15
  start-page: 81
  issue: 1
  year: 1992
  ident: bib7-20231012
  article-title: The effect of magnetic resonance imagers on implanted neurostimulators
  publication-title: Pacing Clin Electrophysiol
  doi: 10.1111/j.1540-8159.1992.tb02904.x
– volume: 50
  start-page: 4245
  issue: 18
  year: 2005
  ident: bib21-20231012
  article-title: Tissue-mimicking phantom materials for narrowband and ultrawideband microwave applications
  publication-title: Phys Med Biol
  doi: 10.1088/0031-9155/50/18/001
– volume: 20
  start-page: 315
  issue: 2
  year: 2004
  ident: bib22-20231012
  article-title: Evaluation of specific absorption rate as a dosimeter of MRI-related implant heating
  publication-title: J Magn Reson Imaging
  doi: 10.1002/jmri.20103
– volume: 99
  start-page: 772
  issue: 4
  year: 2003
  ident: bib10-20231012
  article-title: Transient dystonia following magnetic resonance imaging in a patient with deep brain stimulation electrodes for the treatment of parkinson disease. Case report
  publication-title: J Neurosurg
  doi: 10.3171/jns.2003.99.4.0772
– volume: 37
  start-page: 508
  issue: 2
  year: 2007
  ident: bib18-20231012
  article-title: Functional MRI with active, fully implanted, deep brain stimulation systems: safety and experimental confounds
  publication-title: Neuroimage
  doi: 10.1016/j.neuroimage.2007.04.058
– volume: 15
  start-page: 241
  issue: 3
  year: 2002
  ident: bib9-20231012
  article-title: Neurostimulation systems for deep brain stimulation: in vitro evaluation of magnetic resonance imaging-related heating at 1.5 tesla
  publication-title: J Magn Reson Imaging
  doi: 10.1002/jmri.10069
– volume: 142
  start-page: 3129
  issue: 10
  year: 2019
  ident: bib3-20231012
  article-title: Deep brain stimulation induced normalization of the human functional connectome in parkinson's disease
  publication-title: Brain
  doi: 10.1093/brain/awz239
– volume: 23
  start-page: 549
  issue: 4
  year: 2005
  ident: bib17-20231012
  article-title: Bilateral neurostimulation systems used for deep brain stimulation: in vitro study of MRI-related heating at 1.5 T and implications for clinical imaging of the brain
  publication-title: Magn Reson Imaging
  doi: 10.1016/j.mri.2005.02.007
– volume: 13
  start-page: 378
  issue: 2
  year: 2020
  ident: bib1-20231012
  article-title: Clinical trials for deep brain stimulation: current state of affairs
  publication-title: Brain Stimul
  doi: 10.1016/j.brs.2019.11.008
– volume: 114
  start-page: 1285
  issue: 12
  year: 2006
  ident: bib14-20231012
  article-title: Strategy for safe performance of extrathoracic magnetic resonance imaging at 1.5 tesla in the presence of cardiac pacemakers in non-pacemaker-dependent patients: a prospective study with 115 examinations
  publication-title: Circulation
  doi: 10.1161/CIRCULATIONAHA.105.597013
– volume: 9
  start-page: 21
  issue: 1
  year: 2007
  ident: bib13-20231012
  article-title: Cardiac pacemakers and implantable cardioverter defibrillators: in vitro magnetic resonance imaging evaluation at 1.5-tesla
  publication-title: J Cardiovasc Magn Reson
  doi: 10.1080/10976640600897237
SSID ssj0016478
Score 2.4269185
Snippet Abstract BACKGROUND Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance...
Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging (MRI) has...
BACKGROUND: Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging...
BACKGROUND Deep brain stimulation (DBS) is a standard of care treatment for multiple neurologic disorders. Although 3-tesla (3T) magnetic resonance imaging...
SourceID unpaywall
pubmedcentral
proquest
gale
pubmed
crossref
oup
SourceType Open Access Repository
Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 349
SubjectTerms Aged
Anthropomorphism
Brain
Brain - physiology
Brain research
Care and treatment
Cohort Studies
Deep brain stimulation
Deep Brain Stimulation - methods
Diagnostic imaging
Electrodes
Electrodes, Implanted
Female
Health sciences
Humans
Magnetic resonance imaging
Magnetic Resonance Imaging - adverse effects
Magnetic Resonance Imaging - instrumentation
Magnetic Resonance Imaging - methods
Male
Medical equipment
Medical imaging equipment
Middle Aged
Nervous system diseases
Neural circuitry
Neurosurgery
Phantoms, Imaging
Pilot Projects
Printing, Three-Dimensional
Research centers
Research—Human—Clinical Studies
Temperature
SummonAdditionalLinks – databaseName: Health & Medical Collection
  dbid: 7X7
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwhV1Lj9MwELZgOcAFgXgFCjIICS5W29iOEy5oeVQL0qKV6IreIsce00ppUtpUqH-BX40ncUMrBHuNJ85jPo8nzvj7CHmpTZKNBQDzk4NmooAx02Azpt04Mw54rFsS1_Mvydml-DyTs7DgtglllfuY2AZqWxtcIx_GQqU-9fYQe7v6wVA1Cv-uBgmN6-TG2KcqiGo16z-4kCor7UoYU8azZNaTNvJhxxY5rHZaCxQKP5iUQmg-2u92kHb-XT15c1ut9O6nLsuDqWlyh9wOOSU97UBwl1yD6h75NfVeAjYF73N6rr9XuFuR4mo9UmwA_bRs9Ylo7ehFx626od8WzZx-AFjRd6gcQb82iyXKe9XrzRs8dVt6o8m6XlJNL-YoP7ykWIi4o7qyeGxR1k044k_f93ufXE4-Tt-fsSC8wIxP6BoGmitn5chpG0urNGSFNs7GPHE2wZxc8sSHAm1MIQsfIrQUkGaF4ZkDI3zEekBOqrqCR4TKVFn_yRIbp0bCKVUUCegMuOVcgihkRNj-zecmsJKjOEaZd3_Hed55Kg-eisir3n7V8XH82xIdmeNA9T0aHfYb-PtCyqv8NFExAkSOIjI4svQDzBw1v_BQuPJqgz1S8hAFNvkfzEbked-M3WNlWwX1Fm2QMjBVsYjIww5Y_aVwrUkqnkREHUGuN0Bu8OOWajFvOcJVOsItwxF53YPziid4_P8neEJuxVjO0xasD8hJs97CU5-PNcWzdtD9BiRzOyw
  priority: 102
  providerName: ProQuest
Title Three-Tesla Magnetic Resonance Imaging of Patients With Deep Brain Stimulators: Results From a Phantom Study and a Pilot Study in Patients
URI https://www.ncbi.nlm.nih.gov/pubmed/33045736
https://www.proquest.com/docview/2478605425
https://www.proquest.com/docview/2450648724
https://pubmed.ncbi.nlm.nih.gov/PMC7803432
https://www.ncbi.nlm.nih.gov/pmc/articles/7803432
UnpaywallVersion submittedVersion
Volume 88
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVPQU
  databaseName: Health & Medical Collection
  customDbUrl:
  eissn: 1524-4040
  dateEnd: 20211231
  omitProxy: true
  ssIdentifier: ssj0016478
  issn: 1524-4040
  databaseCode: 7X7
  dateStart: 20100101
  isFulltext: true
  titleUrlDefault: https://search.proquest.com/healthcomplete
  providerName: ProQuest
– providerCode: PRVPQU
  databaseName: ProQuest Central
  customDbUrl: http://www.proquest.com/pqcentral?accountid=15518
  eissn: 1524-4040
  dateEnd: 20211231
  omitProxy: true
  ssIdentifier: ssj0016478
  issn: 1524-4040
  databaseCode: BENPR
  dateStart: 20100101
  isFulltext: true
  titleUrlDefault: https://www.proquest.com/central
  providerName: ProQuest
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1Lj9MwEB7ttge48BCvQKkMQoKL-4jjuOHWha0WpK2qpSvKKXIch1bkUbWpUPkJ_Go8eakFoYWrPbZjeTwex998A_BKKtcbOlpTczhI6gR6SKUOPSqjoacizWxZkLheTt2La-fjgi9OYFjHwhSgfRWsemmc9NLVssBWrhPVr3FifTEaYDDkKbRdfFNqQft6Oht_KaGKI8o8d1GC6ocUX4kKvlTbMfckZ9CQNrJ-yRbZT_dSOpgo_OBQqkzzUbzbgdv5J3ry1i5dy_13GccHR9PkLlzVkyoRKd96uzzoqR-_8T3-16zvwZ3KUSXjsuo-nOj0Afycm6XXdK6NIpFL-TXFEEiCTwDI26HJh6RIekSyiMxKwtYt-bzKl-S91mtyhukoyKd8lWDOsGyzfYtNd7ERmmyyhEgyW2JO44QgunFPZBpi2SrO8qrENK_7fQjXk_P5uwtaZXOgyniJOdWSiSjkg0iGNg-F1F4gVRTazI1CFx19zlxjX6RSAQ-M3ZHc0SMvUMyLtHKMGXwErTRL9RMgfCRCcw-yVSQGTiREELhaepqFjHHtBNwCWi-nryqqc8y4Efvlkzvzy-X3q-W34HUjvy5JPv4uidrh4-43PSpZBTGY70IeLX_sChujd_nAgs6RpNm16qj6pdGvG0fr1OrnV6Zl69umvbmDGltrwYumGrtHuFyqsx3KIA_hSNiOBY9LbW2Gwh9YXDDXAnGkx40AEo4f1xiNLIjHKyW04E2j8TfM4Om_iz6D2zbihQpEfAda-WannxuHLw-6cCoWogvts_Pp7KpbbfhfZopdWg
linkProvider Unpaywall
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lj9MwELaW5bBcEIhXoIBBILhYbWM7TpAQWliqlt2uVqIress6zoRWapPSplr1L_Bj-I148qIVgj3tNZ44j_nGHtsz3xDyShsv6AoAZicHzUQEXaYhDphOuoFJgLu6IHEdnnr9c_FlLMd75FedC4NhlfWYWAzUcWZwj7ztCuVb19tC7MPiB8OqUXi6WpfQKGFxDJtLu2RbvR8cWf2-dt3e59GnPquqCjBjvZWcgeYqiWUn0bErY6UhiLRJYpd7Seyhwym5Z3GujYlkZPGvpQA_iAwPEjDCmqPt9wa5KXhHIFe_GjcLPKTm8suQSZ_xwBs3JJG8XbJTttON1gILk29NgtVUsJNft-Xm_h2tebBOF3pzqWezramwd4fcrnxYeliC7i7Zg_Qe-TmyqAA2AosxOtTfU8yOpHg6gJQeQAfzoh4SzRJ6VnK5rui3aT6hRwAL-hErVdCv-XSO5cSy5eod3rqeWaHeMptTTc8mWO54TjHwcUN1GuO16SzLqyv29rrf--T8WlTygOynWQqPCJW-iu0SyTWJ6ohEqSjyQAfAY84liEg6hNV_PjQVCzoW45iF5Wk8D0tNhZWmHPKmkV-U_B__lkRFhjgw2B6NrvIb7HshxVZ46CkXASI7DmntSFqDNjvNLy0Urnxaq0ZKWI06q_CPjTjkRdOM3WMkXQrZGmWQotBXrnDIwxJYzaNwb0sq7jlE7UCuEUAu8t2WdDopOMmV38EUZYe8bcB5xRc8_v8XPCcH_dHwJDwZnB4_IbdcDCUqguVbZD9fruGp9QXz6FlhgJRcXLfF_wZjTnnC
linkToUnpaywall http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1Zj9MwELaW7gO8cIhjAwUZhAQv7hHbccJbOaoFaVcVtKI8Rbbj0IocVZsIlZ_Ar8aTSy0ILbzaYzuWx-Nx_M03CD2X2gvGzBhiDwdJmDJjIk0UEBmPAx0b6sqKxPXi0jtfsA9LvjxB4zYWpgLta7UeZEk6yNarClu5SfWwxYkNhT-CYMhr6NSDN6UeOl1cziZfaqiiT2jgLWtQ_ZjAK1HFl-oye09io460kQ5rtshhtpeSQaLwg0OpMc1H8W4Hbuef6MnrZbaR--8ySQ6Opukt9LGdVI1I-TYoCzXQP37je_yvWd9GNxtHFU_qqjvoxGR30c-5XXpD5sYqEr6QXzMIgcTwBAC8HQa_T6ukRziP8awmbN3hz-tihd8as8GvIR0F_lSsU8gZlm93r6BpmVih6TZPscSzFeQ0TjGgG_dYZhGUrZO8aEps87bfe2gxfTd_c06abA5EWy-xIEZSEUd8FMvI5ZGQJlBSx5FLvTjywNHn1LP2RWqtuLJ2R3Jm_EBpGsRGM2sG76NelmfmDGHui8jeg1wdixGLhVDKMzIwNKKUG6a4g0i7nKFuqM4h40YS1k_uNKyXP2yW30EvOvlNTfLxd0nQjhB2v-1RyyaIwX4X8GiFE0-4EL3LRw7qH0naXauPqp9Z_bpytH6rfmFjWnaha9vbO6i1tQ562lVD9wCXy0xeggzwEPrCZQ56UGtrNxT8wOKCeg4SR3rcCQDh-HGN1ciKeLxRQge97DT-ihk8_HfRR-iGC3ihChHfR71iW5rH1uEr1JNmi_8CYy1a2Q
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Three-Tesla+Magnetic+Resonance+Imaging+of+Patients+With+Deep+Brain+Stimulators%3A+Results+From+a+Phantom+Study+and+a+Pilot+Study+in+Patients&rft.jtitle=Neurosurgery&rft.au=Davidson%2C+Benjamin&rft.au=Tam%2C+Fred&rft.au=Yang%2C+Benson&rft.au=Meng%2C+Ying&rft.date=2021-02-01&rft.issn=1524-4040&rft.eissn=1524-4040&rft.volume=88&rft.issue=2&rft.spage=349&rft_id=info:doi/10.1093%2Fneuros%2Fnyaa439&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0148-396X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0148-396X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0148-396X&client=summon