Automated pericardial fat quantification from coronary magnetic resonance angiography: feasibility study

Pericardial fat volume (PFV) is emerging as an important parameter for cardiovascular risk stratification. We propose a hybrid approach for automated PFV quantification from water/fat-resolved whole-heart noncontrast coronary magnetic resonance angiography (MRA). Ten coronary MRA datasets were acqui...

Full description

Saved in:
Bibliographic Details
Published inJournal of medical imaging (Bellingham, Wash.) Vol. 3; no. 1; p. 014002
Main Authors Ding, Xiaowei, Pang, Jianing, Ren, Zhou, Diaz-Zamudio, Mariana, Jiang, Chenfanfu, Fan, Zhaoyang, Berman, Daniel S, Li, Debiao, Terzopoulos, Demetri, Slomka, Piotr J, Dey, Damini
Format Journal Article
LanguageEnglish
Published United States Society of Photo-Optical Instrumentation Engineers 01.01.2016
Subjects
Online AccessGet full text
ISSN2329-4302
2329-4310
2329-4310
DOI10.1117/1.JMI.3.1.014002

Cover

More Information
Summary:Pericardial fat volume (PFV) is emerging as an important parameter for cardiovascular risk stratification. We propose a hybrid approach for automated PFV quantification from water/fat-resolved whole-heart noncontrast coronary magnetic resonance angiography (MRA). Ten coronary MRA datasets were acquired. Image reconstruction and phase-based water-fat separation were conducted offline. Our proposed algorithm first roughly segments the heart region on the original image using a simplified atlas-based segmentation with four cases in the atlas. To get exact boundaries of pericardial fat, a three-dimensional graph-based segmentation is used to generate fat and nonfat components on the fat-only image. The algorithm then selects the components that represent pericardial fat. We validated the quantification results on the remaining six subjects and compared them with manual quantifications by an expert reader. The PFV quantified by our algorithm was 62.78±27.85  cm3, compared to 58.66±27.05  cm3 by the expert reader, which were not significantly different (p=0.47) and showed excellent correlation (R=0.89,p<0.01). The mean absolute difference in PFV between the algorithm and the expert reader was 9.9±8.2  cm3. The mean value of the paired differences was −4.13  cm3 (95% confidence interval: −14.47 to 6.21). The mean Dice coefficient of pericardial fat voxels was 0.82±0.06. Our approach may potentially be applied in a clinical setting, allowing for accurate magnetic resonance imaging (MRI)-based PFV quantification without tedious manual tracing.