Comparison of band and spot electrodes for the measurement of stroke volume by the bioelectric impedance technique
Conventional impedance cardiography uses a tetrapolar band electrode configuration to determine thoracic bioelectrical impedance changes and to quantify cardiovascular variables. The present study evaluated the effect of electrode type, band or electrocardiograph (spot), placed in the same anatomica...
Saved in:
| Published in | Critical care medicine Vol. 22; no. 3; p. 420 |
|---|---|
| Main Authors | , |
| Format | Journal Article |
| Language | English |
| Published |
United States
01.03.1994
|
| Subjects | |
| Online Access | Get more information |
| ISSN | 0090-3493 |
| DOI | 10.1097/00003246-199403000-00011 |
Cover
| Abstract | Conventional impedance cardiography uses a tetrapolar band electrode configuration to determine thoracic bioelectrical impedance changes and to quantify cardiovascular variables. The present study evaluated the effect of electrode type, band or electrocardiograph (spot), placed in the same anatomical location, on both the absolute value of cardiovascular variables and the percent change in the variable when the patient changed position from supine to standing.
Prospective, randomized studies using repeated-measures design.
Research laboratory.
Twenty-one adult volunteer subjects.
Subjects were studied while supine and again when standing, in random order as to first position.
Stroke volume and impedance-derived variables were measured. Values for stroke volume measured by the band electrode array were 85 +/- 7 and 49 +/- 3 mL for supine and standing, respectively. In contrast, stroke volume measured through the spot electrodes was 110 +/- 8 and 59 +/- 3 mL, respectively. These differences were due to a lower baseline thoracic bioelectrical impedance value measured through the spot electrodes. However, the percent changes for stroke volume with standing subjects were the same when measured through band (-41 +/- 3%) or spot (-44 +/- 3%) electrodes.
The comparison of cardiovascular values obtained by impedance cardiography should be accomplished only when the values are obtained using similar electrode configuration and type. While there may be a variation in the absolute value of the variable, the direction and magnitude of the change in the variable is relatively unaffected by the electrode types as used in this study. |
|---|---|
| AbstractList | Conventional impedance cardiography uses a tetrapolar band electrode configuration to determine thoracic bioelectrical impedance changes and to quantify cardiovascular variables. The present study evaluated the effect of electrode type, band or electrocardiograph (spot), placed in the same anatomical location, on both the absolute value of cardiovascular variables and the percent change in the variable when the patient changed position from supine to standing.
Prospective, randomized studies using repeated-measures design.
Research laboratory.
Twenty-one adult volunteer subjects.
Subjects were studied while supine and again when standing, in random order as to first position.
Stroke volume and impedance-derived variables were measured. Values for stroke volume measured by the band electrode array were 85 +/- 7 and 49 +/- 3 mL for supine and standing, respectively. In contrast, stroke volume measured through the spot electrodes was 110 +/- 8 and 59 +/- 3 mL, respectively. These differences were due to a lower baseline thoracic bioelectrical impedance value measured through the spot electrodes. However, the percent changes for stroke volume with standing subjects were the same when measured through band (-41 +/- 3%) or spot (-44 +/- 3%) electrodes.
The comparison of cardiovascular values obtained by impedance cardiography should be accomplished only when the values are obtained using similar electrode configuration and type. While there may be a variation in the absolute value of the variable, the direction and magnitude of the change in the variable is relatively unaffected by the electrode types as used in this study. |
| Author | Gotshall, R W Sexson, W R |
| Author_xml | – sequence: 1 givenname: R W surname: Gotshall fullname: Gotshall, R W organization: Department of Exercise and Sport Science, Colorado State University, Fort Collins 80523 – sequence: 2 givenname: W R surname: Sexson fullname: Sexson, W R |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/8124992$$D View this record in MEDLINE/PubMed |
| BookMark | eNotT8tqwzAQ1CElTdJ-QkE_4FbPyDoW0xcEemnPQbJXRK0luZJdyN_XabIwLLMzOzBrtIgpAkKYkntKtHog83AmthXVWhA-s2oGpQu0IkSTigvNr9G6lK_5KqTiS7SsKRNasxXKTQqDyb6kiJPD1sQOn1CGNGLooR1z6qBglzIeD4ADmDJlCBDHk7_M8jfg39RPAbA9_nusT-dP32IfBuhMbAGP0B6i_5ngBl050xe4vewN-nx--mheq937y1vzuKtaoTStpCOKOcW5dMpI1QkmJAPLudrymkjmmNTUOKepZC1xpgZqLFfKWApUOMI26O6cO0w2QLcfsg8mH_eX7uwPXmVeEQ |
| CitedBy_id | crossref_primary_10_1111_j_1469_8986_2010_01010_x crossref_primary_10_1177_009127009703700117 crossref_primary_10_3758_s13428_022_01817_4 crossref_primary_10_1097_00005768_199808000_00022 crossref_primary_10_1109_TBCAS_2019_2959437 crossref_primary_10_1016_S0304_3959_03_00300_2 crossref_primary_10_1027_0269_8803_19_3_195 |
| ContentType | Journal Article |
| DBID | CGR CUY CVF ECM EIF NPM |
| DOI | 10.1097/00003246-199403000-00011 |
| DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
| DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
| DatabaseTitleList | MEDLINE |
| Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
| DeliveryMethod | no_fulltext_linktorsrc |
| Discipline | Medicine |
| ExternalDocumentID | 8124992 |
| Genre | Comparative Study Clinical Trial Randomized Controlled Trial Journal Article |
| GroupedDBID | --- .-D .3C .55 .GJ .XZ .Z2 01R 0R~ 1J1 354 3O- 40H 4Q1 4Q2 4Q3 53G 5GY 5RE 5VS 6J9 6PF 71W 77Y 7O~ AAAAV AAAXR AAGIX AAHPQ AAIQE AAJCS AAMOA AAMTA AAQKA AAQQT AARTV AASCR AASOK AASXQ AAUEB AAWTL AAXQO AAYEP AAYOK ABASU ABBUW ABDIG ABJNI ABOCM ABPPZ ABVCZ ABXVJ ABZAD ACCJW ACDDN ACEWG ACGFO ACGFS ACIJW ACILI ACLDA ACOAL ACWDW ACWRI ACXJB ACXNZ ADFPA ADGGA ADHPY ADNKB AE3 AE6 AEBDS AEETU AENEX AFDTB AFEXH AFFNX AFSOK AFUWQ AGINI AHOMT AHQNM AHRYX AHVBC AI. AIJEX AINUH AJCLO AJIOK AJNWD AJNYG AJZMW AKCTQ AKULP ALKUP ALMA_UNASSIGNED_HOLDINGS ALMTX AMJPA AMKUR AMNEI AOHHW AWKKM BOYCO BQLVK BS7 BYPQX C45 CGR CS3 CUY CVF DIWNM DU5 DUNZO E.X EBS ECM EEVPB EIF EJD ERAAH EX3 F2K F2L F2M F2N F5P FCALG FL- FW0 GNXGY GQDEL H0~ HLJTE HZ~ IE0 IKREB IKYAY IN~ IPNFZ J5H JF9 JG8 JK3 JK8 K-A K-F K8S KD2 KMI L-C L7B M18 N4W N9A NEJ NPM N~7 N~B N~M O9- OAG OAH OB4 OBH OCUKA ODA ODMTH ODZKP OHH OHT OHYEH OJAPA OL1 OLB OLG OLH OLU OLV OLW OLY OLZ ONV OPUJH ORVUJ OUVQU OVD OVDNE OVIDH OVLEI OVOZU OWBYB OWU OWV OWW OWX OWY OWZ OXXIT P-K P2P PKN PONUX R58 RIG RLZ S4R S4S T8P TEORI TSPGW V2I VH1 VVN W3M WOQ WOW X3V X3W X7M XXN XYM YCJ YFH YOC YOJ ZCG ZFV ZGI ZXP ZY1 ZZMQN ~9M |
| ID | FETCH-LOGICAL-c4791-5f072f7335f7a57d42452eb337638052f2591aff9152c0fa8e1ab377ab1e14f02 |
| ISSN | 0090-3493 |
| IngestDate | Wed Feb 19 02:35:27 EST 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 3 |
| Language | English |
| LinkModel | OpenURL |
| MergedId | FETCHMERGED-LOGICAL-c4791-5f072f7335f7a57d42452eb337638052f2591aff9152c0fa8e1ab377ab1e14f02 |
| PMID | 8124992 |
| ParticipantIDs | pubmed_primary_8124992 |
| PublicationCentury | 1900 |
| PublicationDate | 1994-March |
| PublicationDateYYYYMMDD | 1994-03-01 |
| PublicationDate_xml | – month: 03 year: 1994 text: 1994-March |
| PublicationDecade | 1990 |
| PublicationPlace | United States |
| PublicationPlace_xml | – name: United States |
| PublicationTitle | Critical care medicine |
| PublicationTitleAlternate | Crit Care Med |
| PublicationYear | 1994 |
| SSID | ssj0014573 |
| Score | 1.5379456 |
| Snippet | Conventional impedance cardiography uses a tetrapolar band electrode configuration to determine thoracic bioelectrical impedance changes and to quantify... |
| SourceID | pubmed |
| SourceType | Index Database |
| StartPage | 420 |
| SubjectTerms | Adult Analysis of Variance Cardiography, Impedance - instrumentation Electrocardiography - instrumentation Electrodes Female Humans Male Middle Aged Posture Prospective Studies Random Allocation Reference Values Stroke Volume |
| Title | Comparison of band and spot electrodes for the measurement of stroke volume by the bioelectric impedance technique |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/8124992 |
| Volume | 22 |
| hasFullText | |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3NS8MwFA9OUXYRP_GbHLyVytomzXIU8QNBTxt6k6RNYMg2cTuof73vJVlb5hT10FKaLGz5_fbyXvI-CDk1nW4peVfFkossZooVsc5NGXOGuV6kya3P9nmf3_TZ7SN_rH1VXXTJVJ8VHwvjSv6DKrwDXDFK9g_IVoPCC3gGfOEOCMP9VxhfNIsIRjrkXY3AUp1Gob5NaSaVJ-Gw3g_E_hNofjaRl09ODYU-ejD2nxwUGEFpShdSUGV6beqyVZUE5z02f0h_PZ5OsFCLwzCqd3LMW4jxegi-imWIwWO1z9VMjEoQ3syXNpyJ0TRt0CVryETmot2-ymqfAxgXTFDqcvR4YSBxfKC7F8ANCF-GDkNUR6Qvnvdj41wO7dDSIi0hsL7HPW7phKMmxoMbQvhNwd1rltlz0Xdrk9Uw4pwx4pSS3gZZD9YEPffU2CRLZrRF1u4CFNvktWYIHVuKDKF4IUNozRAKDKGAPm0wBPt7hlA_9VS_uz4NhtCKIbRiyA7pX132Lm7iUGUjLpiQScxtR6RWZBm3QnFR4lF4anSGKw_Wu7BgICfKWgmaXtGxqmsSpTMhlE5Mwmwn3SXLo_HI7BGqLKytNuFWqi4zvJRlxlRuCqOZBsM03Se7fraeXnwqlacwjQffNRySdk3AI7Ji4Z9rjkENnOoTB-Mnh59aZA |
| linkProvider | National Library of Medicine |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Comparison+of+band+and+spot+electrodes+for+the+measurement+of+stroke+volume+by+the+bioelectric+impedance+technique&rft.jtitle=Critical+care+medicine&rft.au=Gotshall%2C+R+W&rft.au=Sexson%2C+W+R&rft.date=1994-03-01&rft.issn=0090-3493&rft.volume=22&rft.issue=3&rft.spage=420&rft_id=info:doi/10.1097%2F00003246-199403000-00011&rft_id=info%3Apmid%2F8124992&rft_id=info%3Apmid%2F8124992&rft.externalDocID=8124992 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0090-3493&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0090-3493&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0090-3493&client=summon |