Phase-based block matching applied to motion estimation with unconventional beamforming strategies

A phase-based block matching method adapted to motion estimation with unconventional beamforming strategies is presented. The unconventional beamforming technique used allows us to obtain 2-D RF images with axial and lateral modulations. Based on these images, we propose a method that uses phase ima...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on ultrasonics, ferroelectrics, and frequency control Vol. 56; no. 5; pp. 945 - 957
Main Authors Basarab, A., Gueth, P., Liebgott, H., Delachartre, P.
Format Journal Article
LanguageEnglish
Published New York, NY IEEE 01.05.2009
Institute of Electrical and Electronics Engineers
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text
ISSN0885-3010
1525-8955
1525-8955
DOI10.1109/TUFFC.2009.1127

Cover

Abstract A phase-based block matching method adapted to motion estimation with unconventional beamforming strategies is presented. The unconventional beamforming technique used allows us to obtain 2-D RF images with axial and lateral modulations. Based on these images, we propose a method that uses phase images instead of amplitude images. This way of proceeding allows us to provide an analytical solution to the local displacement estimation so that no minimization of a classical cost function is used for the local estimation. For this reason, the local estimator is directly applied to signals, without the need to process a complex cross-correlation function, as is done with most of the phase shift estimators. In this paper, the method is applied to elastography. Results with simulated data show that a downsampling of axial and lateral modulated signals leads to very little change in the accuracy and in the spatial resolution of the proposed method. For example, for decimation factors of 2 in the axial direction and of 4 in the lateral direction, the mean axial absolute error is 3 mum. The same estimation with original images provides a mean axial error of 0.7 mum. The accuracy of the lateral motion is unchanged in this case. The accuracy of our method with downsampled signals is an important issue in the purpose of a real-time implementation. With experimental data, for the same level of estimation error, classical block matching using the maximum of cross correlation as a local estimator requires images that are 36 times larger (in number of pixels) and consequently a computational time roughly 10 times longer. Our phase block matching is also shown to provide 10 percent less error than a motion estimation method based on seeking the zero of the complex correlation function phase. Finally, it is shown that given the separability of the local estimator that we propose, our method can be applied on both n-D signals and classical RF ultrasound images. The phase block matching method presented was implemented in real time on an ultrasound research scanner.
AbstractList A phase-based block matching method adapted to motion estimation with unconventional beamforming strategies is presented. The unconventional beamforming technique used allows us to obtain 2-D RF images with axial and lateral modulations. Based on these images, we propose a method that uses phase images instead of amplitude images. This way of proceeding allows us to provide an analytical solution to the local displacement estimation so that no minimization of a classical cost function is used for the local estimation. For this reason, the local estimator is directly applied to signals, without the need to process a complex cross-correlation function, as is done with most of the phase shift estimators. In this paper, the method is applied to elastography. Results with simulated data show that a downsampling of axial and lateral modulated signals leads to very little change in the accuracy and in the spatial resolution of the proposed method. For example, for decimation factors of 2 in the axial direction and of 4 in the lateral direction, the mean axial absolute error is 3 mum. The same estimation with original images provides a mean axial error of 0.7 microm. The accuracy of the lateral motion is unchanged in this case. The accuracy of our method with downsampled signals is an important issue in the purpose of a real-time implementation. With experimental data, for the same level of estimation error, classical block matching using the maximum of cross correlation as a local estimator requires images that are 36 times larger (in number of pixels) and consequently a computational time roughly 10 times longer. Our phase block matching is also shown to provide 10 percent less error than a motion estimation method based on seeking the zero of the complex correlation function phase. Finally, it is shown that given the separability of the local estimator that we propose, our method can be applied on both n-D signals and classical RF ultrasound images. The phase block matching method presented was implemented in real time on an ultrasound research scanner.
A phase-based block matching method adapted to motion estimation with unconventional beamforming strategies is presented. The unconventional beamforming technique used allows us to obtain 2-D RF images with axial and lateral modulations. Based on these images, we propose a method that uses phase images instead of amplitude images. This way of proceeding allows us to provide an analytical solution to the local displacement estimation so that no minimization of a classical cost function is used for the local estimation. For this reason, the local estimator is directly applied to signals, without the need to process a complex cross-correlation function, as is done with most of the phase shift estimators. In this paper, the method is applied to elastography. Results with simulated data show that a downsampling of axial and lateral modulated signals leads to very little change in the accuracy and in the spatial resolution of the proposed method. For example, for decimation factors of 2 in the axial direction and of 4 in the lateral direction, the mean axial absolute error is 3 mum. The same estimation with original images provides a mean axial error of 0.7 microm. The accuracy of the lateral motion is unchanged in this case. The accuracy of our method with downsampled signals is an important issue in the purpose of a real-time implementation. With experimental data, for the same level of estimation error, classical block matching using the maximum of cross correlation as a local estimator requires images that are 36 times larger (in number of pixels) and consequently a computational time roughly 10 times longer. Our phase block matching is also shown to provide 10 percent less error than a motion estimation method based on seeking the zero of the complex correlation function phase. Finally, it is shown that given the separability of the local estimator that we propose, our method can be applied on both n-D signals and classical RF ultrasound images. The phase block matching method presented was implemented in real time on an ultrasound research scanner.A phase-based block matching method adapted to motion estimation with unconventional beamforming strategies is presented. The unconventional beamforming technique used allows us to obtain 2-D RF images with axial and lateral modulations. Based on these images, we propose a method that uses phase images instead of amplitude images. This way of proceeding allows us to provide an analytical solution to the local displacement estimation so that no minimization of a classical cost function is used for the local estimation. For this reason, the local estimator is directly applied to signals, without the need to process a complex cross-correlation function, as is done with most of the phase shift estimators. In this paper, the method is applied to elastography. Results with simulated data show that a downsampling of axial and lateral modulated signals leads to very little change in the accuracy and in the spatial resolution of the proposed method. For example, for decimation factors of 2 in the axial direction and of 4 in the lateral direction, the mean axial absolute error is 3 mum. The same estimation with original images provides a mean axial error of 0.7 microm. The accuracy of the lateral motion is unchanged in this case. The accuracy of our method with downsampled signals is an important issue in the purpose of a real-time implementation. With experimental data, for the same level of estimation error, classical block matching using the maximum of cross correlation as a local estimator requires images that are 36 times larger (in number of pixels) and consequently a computational time roughly 10 times longer. Our phase block matching is also shown to provide 10 percent less error than a motion estimation method based on seeking the zero of the complex correlation function phase. Finally, it is shown that given the separability of the local estimator that we propose, our method can be applied on both n-D signals and classical RF ultrasound images. The phase block matching method presented was implemented in real time on an ultrasound research scanner.
A phase-based block matching method adapted to motion estimation with unconventional beamforming strategies is presented. The unconventional beamforming technique used allows us to obtain 2-D RF images with axial and lateral modulations. Based on these images, we propose a method that uses phase images instead of amplitude images. This way of proceeding allows us to provide an analytical solution to the local displacement estimation so that no minimization of a classical cost function is used for the local estimation. For this reason, the local estimator is directly applied to signals, without the need to process a complex cross-correlation function, as is done with most of the phase shift estimators. In this paper, the method is applied to elastography. Results with simulated data show that a downsampling of axial and lateral modulated signals leads to very little change in the accuracy and in the spatial resolution of the proposed method. For example, for decimation factors of 2 in the axial direction and of 4 in the lateral direction, the mean axial absolute error is 3 mum. The same estimation with original images provides a mean axial error of 0.7 mum. The accuracy of the lateral motion is unchanged in this case. The accuracy of our method with downsampled signals is an important issue in the purpose of a real-time implementation. With experimental data, for the same level of estimation error, classical block matching using the maximum of cross correlation as a local estimator requires images that are 36 times larger (in number of pixels) and consequently a computational time roughly 10 times longer. Our phase block matching is also shown to provide 10 percent less error than a motion estimation method based on seeking the zero of the complex correlation function phase. Finally, it is shown that given the separability of the local estimator that we propose, our method can be applied on both n-D signals and classical RF ultrasound images. The phase block matching- method presented was implemented in real time on an ultrasound research scanner.
A phase-based block matching method adapted to motion estimation with unconventional beamforming strategies is presented. The unconventional beamforming technique used allows us to obtain 2-D RF images with axial and lateral modulations. Based on these images, we propose a method that uses phase images instead of amplitude images. This way of proceeding allows us to provide an analytical solution to the local displacement estimation so that no minimization of a classical cost function is used for the local estimation. For this reason, the local estimator is directly applied to signals, without the need to process a complex cross-correlation function, as is done with most of the phase shift estimators. In this paper, the method is applied to elastography. Results with simulated data show that a downsampling of axial and lateral modulated signals leads to very little change in the accuracy and in the spatial resolution of the proposed method. For example, for decimation factors of 2 in the axial direction and of 4 in the lateral direction, the mean axial absolute error is 3 m. The same estimation with original images provides a mean axial error of 0.7 m. The accuracy of the lateral motion is unchanged in this case. The accuracy of our method with downsampled signals is an important issue in the purpose of a real-time implementation. With experimental data, for the same level of estimation error, classical block matching using the maximum of cross correlation as a local estimator requires images that are 36 times larger (in number of pixels) and consequently a computational time roughly 10 times longer. Our phase block matching is also shown to provide 10 percent less error than a motion estimation method based on seeking the zero of the complex correlation function phase. Finally, it is shown that given the separability of the local estimator that we propose, our method can be applied on both n-D signals and classical RF ultrasound images. The phase -.
[...] it is shown that given the separability of the local estimator that we propose, our method can be applied on both n-D signals and classical RF ultrasound images.
Author Liebgott, H.
Basarab, A.
Gueth, P.
Delachartre, P.
Author_xml – sequence: 1
  givenname: A.
  surname: Basarab
  fullname: Basarab, A.
  organization: CREATIS-LRMN, Univ. of Lyon, Villeurbanne
– sequence: 2
  givenname: P.
  surname: Gueth
  fullname: Gueth, P.
  organization: CREATIS-LRMN, Univ. of Lyon, Villeurbanne
– sequence: 3
  givenname: H.
  surname: Liebgott
  fullname: Liebgott, H.
  organization: CREATIS-LRMN, Univ. of Lyon, Villeurbanne
– sequence: 4
  givenname: P.
  surname: Delachartre
  fullname: Delachartre, P.
  organization: CREATIS-LRMN, Univ. of Lyon, Villeurbanne
BackLink http://pascal-francis.inist.fr/vibad/index.php?action=getRecordDetail&idt=21742072$$DView record in Pascal Francis
https://www.ncbi.nlm.nih.gov/pubmed/19473913$$D View this record in MEDLINE/PubMed
https://hal.science/hal-00443134$$DView record in HAL
BookMark eNqFkk1v1DAQhi1URLeFMwckFFWiiENa27Fjz7FadSnSSnBoz5bjTLouSbzESRH_Hqe77KEScPHH-HntGc97Qo760CMhbxm9YIzC5e3darW84JRC2nP1giyY5DLXIOURWVCtZV5QRo_JSYwPlDIhgL8ixwyEKoAVC1J929iIeZWGOqva4L5nnR3dxvf3md1uW5_CY8i6MPrQZxhHn47n5U8_brKpd6F_xH6O2Dar0HZNGLpZHMfBjnjvMb4mLxvbRnyzn0_J3er6dnmTr79-_rK8WudOlDDmqqCAILAEiapR2nKuNKBgTald3diUvbWM16y0Ep2wGkqqkJe0krqkUBen5NPu3o1tzXZIiQ6_TLDe3FytzRyjVIiCFeKRJfbjjt0O4ceUyjKdjw7b1vYYpmi0kpQBAE_k-T_JUnFdcgb_BQsBlGshE3j2DHwI05D-Lz2bSgHJpEjQ-z00VR3Wh3r-dC4BH_aAjc62zWB75-OB40wJTtWcv9xxbggxDtgY58enFqYG-dYwamYnmScnmdlJZnZS0l0-0x1S-Kvi3U7hEfFAC1Al17T4DaX80S8
CODEN ITUCER
CitedBy_id crossref_primary_10_1016_j_ultras_2009_11_001
crossref_primary_10_35848_1347_4065_acc112
crossref_primary_10_1118_1_4905376
crossref_primary_10_1109_TUFFC_2017_2710361
crossref_primary_10_1109_TBME_2018_2820384
crossref_primary_10_1177_0161734613476176
crossref_primary_10_1080_10589759_2023_2234554
crossref_primary_10_1109_TUFFC_2015_007320
crossref_primary_10_1016_j_phpro_2010_01_032
crossref_primary_10_1109_TUFFC_2009_1173
crossref_primary_10_1109_TUFFC_2013_2707
crossref_primary_10_1016_j_acha_2014_10_003
crossref_primary_10_1109_TMI_2014_2305846
crossref_primary_10_1109_TUFFC_2014_006910
crossref_primary_10_1016_j_bspc_2024_106181
crossref_primary_10_1016_j_ultrasmedbio_2020_06_006
crossref_primary_10_1109_TUFFC_2012_2370
crossref_primary_10_1088_1361_6560_ad7224
crossref_primary_10_1109_TUFFC_2015_007050
crossref_primary_10_1109_TUFFC_2016_2600763
crossref_primary_10_1109_TSP_2013_2295551
crossref_primary_10_1016_j_ultras_2018_07_012
crossref_primary_10_1109_TUFFC_2016_2622818
crossref_primary_10_1109_TUFFC_2015_007135
crossref_primary_10_1177_0161734614550659
crossref_primary_10_1109_TMI_2020_3005017
Cites_doi 10.1109/78.806066
10.1109/58.741427
10.1109/TUFFC.2008.614
10.1016/0161-7346(91)90079-W
10.1109/58.646923
10.1177/016173469701900303
10.1109/TMI.2007.897408
10.1109/TUFFC.2006.1632687
10.1016/j.media.2007.10.007
10.1109/TUFFC.2003.1197962
10.1109/78.960432
10.1016/0301-5629(94)90033-7
10.1016/S0301-5629(98)00109-4
10.1016/S0301-5629(96)00164-0
10.1109/10.133210
10.1109/TUFFC.2007.308
10.1155/ASP.2005.1212
10.1109/ULTSYM.2003.1293289
10.1109/TUFFC.902
10.1007/BF02480847
10.1109/58.677749
10.1109/TUFFC.2006.1642509
10.1109/TCSVT.2003.815168
10.1109/TMI.2005.852050
10.1016/S0301-5629(00)00316-1
10.1016/S0301-5629(96)00120-2
10.1109/TBME.2002.804587
10.1109/58.741527
10.1109/58.660156
10.1016/S0262-8856(99)00018-9
10.1109/TUFFC.2008.713
10.1109/58.796111
10.1117/3.831079.ch8
ContentType Journal Article
Copyright 2009 INIST-CNRS
Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2009
Distributed under a Creative Commons Attribution 4.0 International License
Copyright_xml – notice: 2009 INIST-CNRS
– notice: Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) 2009
– notice: Distributed under a Creative Commons Attribution 4.0 International License
DBID 97E
RIA
RIE
AAYXX
CITATION
IQODW
CGR
CUY
CVF
ECM
EIF
NPM
7SP
7U5
8FD
F28
FR3
L7M
7X8
1XC
DOI 10.1109/TUFFC.2009.1127
DatabaseName IEEE All-Society Periodicals Package (ASPP) 2005–Present
IEEE All-Society Periodicals Package (ASPP) 1998–Present
IEEE Electronic Library (IEL)
CrossRef
Pascal-Francis
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
Electronics & Communications Abstracts
Solid State and Superconductivity Abstracts
Technology Research Database
ANTE: Abstracts in New Technology & Engineering
Engineering Research Database
Advanced Technologies Database with Aerospace
MEDLINE - Academic
Hyper Article en Ligne (HAL)
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Solid State and Superconductivity Abstracts
Engineering Research Database
Technology Research Database
Advanced Technologies Database with Aerospace
ANTE: Abstracts in New Technology & Engineering
Electronics & Communications Abstracts
MEDLINE - Academic
DatabaseTitleList MEDLINE
MEDLINE - Academic
Engineering Research Database
Engineering Research Database
Solid State and Superconductivity Abstracts

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 3
  dbid: RIE
  name: IEEE Electronic Library (IEL)
  url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/
  sourceTypes: Publisher
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
Physics
Computer Science
EISSN 1525-8955
EndPage 957
ExternalDocumentID oai:HAL:hal-00443134v1
2302910461
19473913
21742072
10_1109_TUFFC_2009_1127
4976280
Genre orig-research
Research Support, Non-U.S. Gov't
Journal Article
GroupedDBID ---
-~X
.GJ
0R~
186
29I
3EH
4.4
53G
5GY
5RE
5VS
6IK
97E
AAJGR
AARMG
AASAJ
AAWTH
ABAZT
ABQJQ
ABVLG
ACGFO
ACGFS
ACIWK
AENEX
AETIX
AGQYO
AGSQL
AHBIQ
AI.
AIBXA
AKJIK
AKQYR
ALLEH
ALMA_UNASSIGNED_HOLDINGS
ATWAV
BEFXN
BFFAM
BGNUA
BKEBE
BPEOZ
CS3
DU5
EBS
EJD
F5P
HZ~
H~9
ICLAB
IFIPE
IFJZH
IPLJI
JAVBF
LAI
M43
O9-
OCL
P2P
RIA
RIE
RNS
TN5
TWZ
UKR
VH1
ZXP
ZY4
AAYXX
CITATION
IQODW
RIG
ABTAH
CGR
CUY
CVF
ECM
EIF
NPM
PKN
Z5M
7SP
7U5
8FD
F28
FR3
L7M
7X8
1XC
ID FETCH-LOGICAL-c469t-7309e94e695e7f78a22789e41f68cdfa001aa12d16a5ec4a89607e260b58609d3
IEDL.DBID RIE
ISSN 0885-3010
1525-8955
IngestDate Tue Oct 14 20:42:58 EDT 2025
Sun Sep 28 06:47:35 EDT 2025
Wed Oct 01 10:41:43 EDT 2025
Thu Oct 02 06:55:59 EDT 2025
Sun Jun 29 12:04:17 EDT 2025
Wed Feb 19 01:50:01 EST 2025
Mon Jul 21 09:13:59 EDT 2025
Wed Oct 01 01:21:48 EDT 2025
Thu Apr 24 23:06:47 EDT 2025
Wed Aug 27 03:07:17 EDT 2025
IsPeerReviewed true
IsScholarly true
Issue 5
Keywords Error estimation
Motion estimation
Phase shift
Minimization
Experimental study
Radiofrequency
Real time
Modeling
Beam forming
Image method
Block matching
Tissue
Modulation
Cross correlation
Displacement measurement
Medical imagery
Acoustic antenna
Acoustic image
Elastography
Spatial resolution
Language English
License https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html
CC BY 4.0
Distributed under a Creative Commons Attribution 4.0 International License: http://creativecommons.org/licenses/by/4.0
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c469t-7309e94e695e7f78a22789e41f68cdfa001aa12d16a5ec4a89607e260b58609d3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ORCID 0000-0003-0492-1846
0000-0002-7602-1452
0000-0002-5642-7244
PMID 19473913
PQID 858695154
PQPubID 23500
PageCount 13
ParticipantIDs crossref_citationtrail_10_1109_TUFFC_2009_1127
crossref_primary_10_1109_TUFFC_2009_1127
proquest_journals_858695154
pubmed_primary_19473913
pascalfrancis_primary_21742072
ieee_primary_4976280
proquest_miscellaneous_875019992
proquest_miscellaneous_67286219
hal_primary_oai_HAL_hal_00443134v1
proquest_miscellaneous_34902845
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2009-05-01
PublicationDateYYYYMMDD 2009-05-01
PublicationDate_xml – month: 05
  year: 2009
  text: 2009-05-01
  day: 01
PublicationDecade 2000
PublicationPlace New York, NY
PublicationPlace_xml – name: New York, NY
– name: United States
– name: New York
PublicationTitle IEEE transactions on ultrasonics, ferroelectrics, and frequency control
PublicationTitleAbbrev T-UFFC
PublicationTitleAlternate IEEE Trans Ultrason Ferroelectr Freq Control
PublicationYear 2009
Publisher IEEE
Institute of Electrical and Electronics Engineers
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Publisher_xml – name: IEEE
– name: Institute of Electrical and Electronics Engineers
– name: The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
References ref13
ref34
ref12
ref15
ref14
ref30
ref33
ref11
ref32
ref10
liebgott (ref31) 2005; 8
ref2
ref1
ref17
ref16
ref19
ref18
ref24
ref23
ref26
ref25
ref20
peyrin (ref35) 1986
ref22
ref21
ref28
ref27
ref29
ref8
ref7
ref4
ref3
ref6
ref5
brusseau (ref9) 2008; 27
IEEE Trans Ultrason Ferroelectr Freq Control. 2009 Jun;56(6):1289
References_xml – ident: ref12
  doi: 10.1109/78.806066
– ident: ref15
  doi: 10.1109/58.741427
– ident: ref20
  doi: 10.1109/TUFFC.2008.614
– ident: ref3
  doi: 10.1016/0161-7346(91)90079-W
– ident: ref7
  doi: 10.1109/58.646923
– ident: ref32
  doi: 10.1177/016173469701900303
– volume: 27
  start-page: 145
  year: 2008
  ident: ref9
  article-title: 2D locally regularized strain estimation algorithm: Theoretical developments and results on experimental data
  publication-title: IEEE Trans Med Imaging
  doi: 10.1109/TMI.2007.897408
– ident: ref19
  doi: 10.1109/TUFFC.2006.1632687
– ident: ref30
  doi: 10.1016/j.media.2007.10.007
– ident: ref4
  doi: 10.1109/TUFFC.2003.1197962
– ident: ref28
  doi: 10.1109/78.960432
– ident: ref13
  doi: 10.1016/0301-5629(94)90033-7
– ident: ref8
  doi: 10.1016/S0301-5629(98)00109-4
– ident: ref5
  doi: 10.1016/S0301-5629(96)00164-0
– ident: ref11
  doi: 10.1109/10.133210
– ident: ref25
  doi: 10.1109/TUFFC.2007.308
– volume: 8
  start-page: 1212
  year: 2005
  ident: ref31
  article-title: Beamforming scheme for 2D displacement estimation in ultrasound imaging
  publication-title: EURASIP J Appl Signal Process
  doi: 10.1155/ASP.2005.1212
– start-page: 677
  year: 1986
  ident: ref35
  publication-title: Signal Processing III Theories and Applications
– ident: ref21
  doi: 10.1109/ULTSYM.2003.1293289
– ident: ref26
  doi: 10.1109/TUFFC.902
– ident: ref22
  doi: 10.1007/BF02480847
– ident: ref24
  doi: 10.1109/58.677749
– ident: ref18
  doi: 10.1109/TUFFC.2006.1642509
– ident: ref1
  doi: 10.1109/10.133210
– ident: ref10
  doi: 10.1109/TCSVT.2003.815168
– ident: ref2
  doi: 10.1109/TMI.2005.852050
– ident: ref14
  doi: 10.1016/S0301-5629(00)00316-1
– ident: ref23
  doi: 10.1016/S0301-5629(96)00120-2
– ident: ref27
  doi: 10.1109/TBME.2002.804587
– ident: ref17
  doi: 10.1109/58.741527
– ident: ref6
  doi: 10.1109/58.660156
– ident: ref29
  doi: 10.1016/S0262-8856(99)00018-9
– ident: ref33
  doi: 10.1109/TUFFC.2008.713
– ident: ref16
  doi: 10.1109/58.796111
– ident: ref34
  doi: 10.1117/3.831079.ch8
– reference: - IEEE Trans Ultrason Ferroelectr Freq Control. 2009 Jun;56(6):1289
SSID ssj0014492
Score 2.126941
Snippet A phase-based block matching method adapted to motion estimation with unconventional beamforming strategies is presented. The unconventional beamforming...
[...] it is shown that given the separability of the local estimator that we propose, our method can be applied on both n-D signals and classical RF ultrasound...
SourceID hal
proquest
pubmed
pascalfrancis
crossref
ieee
SourceType Open Access Repository
Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 945
SubjectTerms Accuracy
Acoustic signal processing
Acoustics
Algorithms
Array signal processing
Bioengineering
Biological and medical sciences
Biomechanics
Blocking
Computer Science
Computer Simulation
Cost function
Elasticity Imaging Techniques - methods
Engineering Sciences
Errors
Estimation error
Estimators
Exact sciences and technology
Fluid mechanics
Fluids mechanics
Fundamental areas of phenomenology (including applications)
Humans
Image Processing
Imaging
Investigative techniques, diagnostic techniques (general aspects)
Life Sciences
Matching
Mathematical analysis
Mathematical models
Mechanics
Mechanics of materials
Medical Imaging
Medical sciences
Miscellaneous. Technology
Motion estimation
Optical modulation
Phase estimation
Physics
Radio frequency
Signal and Image Processing
Signal processing
Signal Processing, Computer-Assisted
Spatial resolution
Studies
Ultrasonic imaging
Ultrasonic investigative techniques
Title Phase-based block matching applied to motion estimation with unconventional beamforming strategies
URI https://ieeexplore.ieee.org/document/4976280
https://www.ncbi.nlm.nih.gov/pubmed/19473913
https://www.proquest.com/docview/858695154
https://www.proquest.com/docview/34902845
https://www.proquest.com/docview/67286219
https://www.proquest.com/docview/875019992
https://hal.science/hal-00443134
Volume 56
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVIEE
  databaseName: IEEE Electronic Library (IEL)
  customDbUrl:
  eissn: 1525-8955
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0014492
  issn: 0885-3010
  databaseCode: RIE
  dateStart: 19860101
  isFulltext: true
  titleUrlDefault: https://ieeexplore.ieee.org/
  providerName: IEEE
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1Nb9QwEB21lZDgUEoLNLQUC3HgQLa243z4WFWsVogiDl2pt8hxbFVq2UUky4Ffz4ydDW3VlVAuq2QsrT3jzJvM-A3Ah0p601jRpEKaLFWttKm2VqVGe9PS5QPP7MW3YjZXX67yqy34NJ6Fcc6F4jM3oZ8hl98u7Yo-lZ0q9J2ywgB9u6yKeFZrzBgoFRog46bJUzRaPtD4CK5PL-fT6XmkpkR0EdruaVVmWmT3nNH2NZVChh4rVCFpOlwkH7tbbIafwQ1Nn8PFegKx-uRmsuqbif3zgNvxf2e4B7sDHmVn0YBewJZb7MOzOyyF-_AkVIna7gCa79fo9FLyfC1r0A3eMAS8oRqTmQhnWb9ksTMQI_6OeDCS0ddehh70Tok7a5z5QYiZBnf9mrHiJcynny_PZ-nQpCG1GFn3Kb4htNPKFTp3pS8rE87WOiV8UdnWG1SNMUK2ojC5s8pUGDKVDqOoJq8KrtvsFewslgt3CEx7zg0Ok5p7jBpdJRuLy-EQw2a6NS6ByVpbtR0YzKmRxm0dIhmu66Bp6qypa9J0Ah_HAT8jecdm0feo_lGKSLdnZ19rukc570xk6rdI4IBUNkoN2krg5J61jM8p3JO8lAkcrc2nHl4RXV3h_BHe5iqBd-NT3NuUsDELt1x1daaIW0flmyWKUmJIKnQCbIMExqOcqCbwT7yOhvtvKYZd8ObxaR3B05g6o-rOY9jpf63cW0RgfXMStt5fVywr7Q
linkProvider IEEE
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3db9MwED-NIQQ88LENCIPNQjzwQDrbcT78OE1UBdqJh1baW-Q4jiYN2mlJeeCv585Ow4aohPJSJWep9p1zv8udfwfwvpCNqayoYiFNEqta2lhbq2KjG1PT1Xie2dl5NlmoLxfpxQ58HM7COOd88Zkb0U-fy69Xdk2fyk4U-k5ZYIB-P1VKpeG01pAzUMq3QMZtk8Zotrwn8hFcn8wX4_FZIKdEfOEb72mVJ1okd9zRvUsqhvRdVqhG0rS4TE3ob7EdgHpHNH4Ks80UQv3J1WjdVSP76y92x_-d4zN40iNSdhpM6DnsuOUePL7FU7gHD3ydqG33ofp2iW4vJt9Xswod4RVDyOvrMZkJgJZ1KxZ6AzFi8AhHIxl972XoQ28VubPKmR-EmWlw2204Kw5gMf40P5vEfZuG2GJs3cX4jtBOK5fp1OVNXhh_utYp0WSFrRuDqjFGyFpkJnVWmQKDptxhHFWlRcZ1nbyA3eVq6V4B0w3nBodJzRuMG10hK4vL4RDFJro2LoLRRlul7TnMqZXG99LHMlyXXtPUW1OXpOkIPgwDrgN9x3bRd6j-QYpotyen05LuUdY7EYn6KSLYJ5UNUr22Iji6Yy3Dcwr4JM9lBIcb8yn7l0RbFjh_BLipiuB4eIq7m1I2ZulW67ZMFLHrqHS7RJZLDEqFjoBtkcCIlBPZBP6Jl8Fw_yxFvwte_3tax_BwMp9Ny-nn86-H8Cgk0qjW8w3sdjdr9xbxWFcd-W34GyMWLzo
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Phase-Based+Block+Matching+Applied+to+Motion+Estimation+with+Unconventional+Beamforming+Strategies&rft.jtitle=IEEE+transactions+on+ultrasonics%2C+ferroelectrics%2C+and+frequency+control&rft.au=BASARAB%2C+Adrian&rft.au=GUETH%2C+Pierre&rft.au=LIEBGOTT%2C+Herv%C3%A9&rft.au=DELACHARTRE%2C+Philippe&rft.date=2009-05-01&rft.pub=Institute+of+Electrical+and+Electronics+Engineers&rft.issn=0885-3010&rft.volume=56&rft.issue=5&rft.spage=945&rft.epage=957&rft_id=info:doi/10.1109%2FTUFFC.2009.1127&rft.externalDBID=n%2Fa&rft.externalDocID=21742072
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0885-3010&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0885-3010&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0885-3010&client=summon