Comparison of right ventricular volume measurements between axial and short axis orientation using steady-state free precession magnetic resonance imaging

Purpose To compare right ventricular (RV) volume measurements and their reproducibility between axial and short axis orientation acquisition techniques. Materials and Methods Measurements of RV volumes from data sets acquired in axial and short axis orientations were compared in 20 normal subjects....

Full description

Saved in:
Bibliographic Details
Published inJournal of magnetic resonance imaging Vol. 18; no. 1; pp. 25 - 32
Main Authors Alfakih, Khaled, Plein, Sven, Bloomer, Tim, Jones, Tim, Ridgway, John, Sivananthan, Mohan
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.07.2003
Subjects
Online AccessGet full text
ISSN1053-1807
1522-2586
DOI10.1002/jmri.10329

Cover

More Information
Summary:Purpose To compare right ventricular (RV) volume measurements and their reproducibility between axial and short axis orientation acquisition techniques. Materials and Methods Measurements of RV volumes from data sets acquired in axial and short axis orientations were compared in 20 normal subjects. The observer variabilities were assessed and the left ventricle (LV) and RV stroke volumes (SV) were compared. Results There was a significant and systematic difference in the EDV and ESV volumes between the axial and short axis methods. The latter method resulted in larger volumes (mean bias EDV 7.5 ± 13.2, 4.7% difference; ESV 7.2 ± 8.6, 10.7% difference). The axial method had lower intra‐ and interobserver variability than the short axis method. The standard deviation of the difference (SDD) and the limits of agreement were consistently lower for the axial method. The mean differences between LV and RV stroke volumes expressed as mean ± 1 SD (r2 =correlation coefficient) were: axial 7.6 ± 9.1 (r2 = 0.93); and short axis 7.4 ± 10.8 (r2 = 0.90). Conclusion There is a significant systematic difference between volumes measured using the two different orientations. The axial orientation resulted in better inter‐ and intraobserver reproducibility. J. Magn. Reson. Imaging 2003;18:25–32. © 2003 Wiley‐Liss, Inc.
Bibliography:ArticleID:JMRI10329
British Heart Foundation
istex:8A255A02FD11644EEFE57ECB3A2F8216E26AD625
ark:/67375/WNG-2TQXF513-S
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1053-1807
1522-2586
DOI:10.1002/jmri.10329