Wearable Sensors Incorporating Compensatory Reserve Measurement for Advancing Physiological Monitoring in Critically Injured Trauma Patients

Vital signs historically served as the primary method to triage patients and resources for trauma and emergency care, but have failed to provide clinically-meaningful predictive information about patient clinical status. In this review, a framework is presented that focuses on potential wearable sen...

Full description

Saved in:
Bibliographic Details
Published inSensors (Basel, Switzerland) Vol. 20; no. 22; p. 6413
Main Authors Convertino, Victor A., Schauer, Steven G., Weitzel, Erik K., Cardin, Sylvain, Stackle, Mark E., Talley, Michael J., Sawka, Michael N., Inan, Omer T.
Format Journal Article
LanguageEnglish
Published Switzerland MDPI 10.11.2020
MDPI AG
Subjects
Online AccessGet full text
ISSN1424-8220
1424-8220
DOI10.3390/s20226413

Cover

Abstract Vital signs historically served as the primary method to triage patients and resources for trauma and emergency care, but have failed to provide clinically-meaningful predictive information about patient clinical status. In this review, a framework is presented that focuses on potential wearable sensor technologies that can harness necessary electronic physiological signal integration with a current state-of-the-art predictive machine-learning algorithm that provides early clinical assessment of hypovolemia status to impact patient outcome. The ability to study the physiology of hemorrhage using a human model of progressive central hypovolemia led to the development of a novel machine-learning algorithm known as the compensatory reserve measurement (CRM). Greater sensitivity, specificity, and diagnostic accuracy to detect hemorrhage and onset of decompensated shock has been demonstrated by the CRM when compared to all standard vital signs and hemodynamic variables. The development of CRM revealed that continuous measurements of changes in arterial waveform features represented the most integrated signal of physiological compensation for conditions of reduced systemic oxygen delivery. In this review, detailed analysis of sensor technologies that include photoplethysmography, tonometry, ultrasound-based blood pressure, and cardiogenic vibration are identified as potential candidates for harnessing arterial waveform analog features required for real-time calculation of CRM. The integration of wearable sensors with the CRM algorithm provides a potentially powerful medical monitoring advancement to save civilian and military lives in emergency medical settings.
AbstractList Vital signs historically served as the primary method to triage patients and resources for trauma and emergency care, but have failed to provide clinically-meaningful predictive information about patient clinical status. In this review, a framework is presented that focuses on potential wearable sensor technologies that can harness necessary electronic physiological signal integration with a current state-of-the-art predictive machine-learning algorithm that provides early clinical assessment of hypovolemia status to impact patient outcome. The ability to study the physiology of hemorrhage using a human model of progressive central hypovolemia led to the development of a novel machine-learning algorithm known as the compensatory reserve measurement (CRM). Greater sensitivity, specificity, and diagnostic accuracy to detect hemorrhage and onset of decompensated shock has been demonstrated by the CRM when compared to all standard vital signs and hemodynamic variables. The development of CRM revealed that continuous measurements of changes in arterial waveform features represented the most integrated signal of physiological compensation for conditions of reduced systemic oxygen delivery. In this review, detailed analysis of sensor technologies that include photoplethysmography, tonometry, ultrasound-based blood pressure, and cardiogenic vibration are identified as potential candidates for harnessing arterial waveform analog features required for real-time calculation of CRM. The integration of wearable sensors with the CRM algorithm provides a potentially powerful medical monitoring advancement to save civilian and military lives in emergency medical settings.
Vital signs historically served as the primary method to triage patients and resources for trauma and emergency care, but have failed to provide clinically-meaningful predictive information about patient clinical status. In this review, a framework is presented that focuses on potential wearable sensor technologies that can harness necessary electronic physiological signal integration with a current state-of-the-art predictive machine-learning algorithm that provides early clinical assessment of hypovolemia status to impact patient outcome. The ability to study the physiology of hemorrhage using a human model of progressive central hypovolemia led to the development of a novel machine-learning algorithm known as the compensatory reserve measurement (CRM). Greater sensitivity, specificity, and diagnostic accuracy to detect hemorrhage and onset of decompensated shock has been demonstrated by the CRM when compared to all standard vital signs and hemodynamic variables. The development of CRM revealed that continuous measurements of changes in arterial waveform features represented the most integrated signal of physiological compensation for conditions of reduced systemic oxygen delivery. In this review, detailed analysis of sensor technologies that include photoplethysmography, tonometry, ultrasound-based blood pressure, and cardiogenic vibration are identified as potential candidates for harnessing arterial waveform analog features required for real-time calculation of CRM. The integration of wearable sensors with the CRM algorithm provides a potentially powerful medical monitoring advancement to save civilian and military lives in emergency medical settings.Vital signs historically served as the primary method to triage patients and resources for trauma and emergency care, but have failed to provide clinically-meaningful predictive information about patient clinical status. In this review, a framework is presented that focuses on potential wearable sensor technologies that can harness necessary electronic physiological signal integration with a current state-of-the-art predictive machine-learning algorithm that provides early clinical assessment of hypovolemia status to impact patient outcome. The ability to study the physiology of hemorrhage using a human model of progressive central hypovolemia led to the development of a novel machine-learning algorithm known as the compensatory reserve measurement (CRM). Greater sensitivity, specificity, and diagnostic accuracy to detect hemorrhage and onset of decompensated shock has been demonstrated by the CRM when compared to all standard vital signs and hemodynamic variables. The development of CRM revealed that continuous measurements of changes in arterial waveform features represented the most integrated signal of physiological compensation for conditions of reduced systemic oxygen delivery. In this review, detailed analysis of sensor technologies that include photoplethysmography, tonometry, ultrasound-based blood pressure, and cardiogenic vibration are identified as potential candidates for harnessing arterial waveform analog features required for real-time calculation of CRM. The integration of wearable sensors with the CRM algorithm provides a potentially powerful medical monitoring advancement to save civilian and military lives in emergency medical settings.
Author Stackle, Mark E.
Convertino, Victor A.
Sawka, Michael N.
Weitzel, Erik K.
Inan, Omer T.
Schauer, Steven G.
Cardin, Sylvain
Talley, Michael J.
AuthorAffiliation 8 Georgia Institute of Technology, Atlanta, GA 30332, USA; michael.sawka@biosci.gatech.edu (M.N.S.); inan@gatech.edu (O.T.I.)
1 Battlefield Health & Trauma Center for Human Integrative Physiology, US Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA; steven.g.schauer.mil@mail.mil
5 Navy Medical Research Unit, JBSA Fort Sam Houston, San Antonio, TX 78234, USA; sylvain.cardin.civ@mail.mil
6 Commander, US Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA; mark.e.stackle.mil@mail.mil
7 Commanding General, US Army Medical Research and Development Command, Fort Detrick, Frederick, MD 21702, USA; michael.j.talley4.mil@mail.mil
3 Brooke Army Medical Center, JBSA Fort Sam Houston, San Antonio, TX 78234, USA
2 Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA; erik.k.weitzel.mil@mail.mil
4 59th Medical Wing, JBSA Lackland, San Antonio, TX 78236, USA
AuthorAffiliation_xml – name: 8 Georgia Institute of Technology, Atlanta, GA 30332, USA; michael.sawka@biosci.gatech.edu (M.N.S.); inan@gatech.edu (O.T.I.)
– name: 1 Battlefield Health & Trauma Center for Human Integrative Physiology, US Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA; steven.g.schauer.mil@mail.mil
– name: 2 Uniformed Services University of the Health Sciences, Bethesda, MD 20814, USA; erik.k.weitzel.mil@mail.mil
– name: 3 Brooke Army Medical Center, JBSA Fort Sam Houston, San Antonio, TX 78234, USA
– name: 4 59th Medical Wing, JBSA Lackland, San Antonio, TX 78236, USA
– name: 5 Navy Medical Research Unit, JBSA Fort Sam Houston, San Antonio, TX 78234, USA; sylvain.cardin.civ@mail.mil
– name: 7 Commanding General, US Army Medical Research and Development Command, Fort Detrick, Frederick, MD 21702, USA; michael.j.talley4.mil@mail.mil
– name: 6 Commander, US Army Institute of Surgical Research, JBSA Fort Sam Houston, San Antonio, TX 78234, USA; mark.e.stackle.mil@mail.mil
Author_xml – sequence: 1
  givenname: Victor A.
  orcidid: 0000-0001-9246-0554
  surname: Convertino
  fullname: Convertino, Victor A.
– sequence: 2
  givenname: Steven G.
  surname: Schauer
  fullname: Schauer, Steven G.
– sequence: 3
  givenname: Erik K.
  orcidid: 0000-0001-9155-3556
  surname: Weitzel
  fullname: Weitzel, Erik K.
– sequence: 4
  givenname: Sylvain
  surname: Cardin
  fullname: Cardin, Sylvain
– sequence: 5
  givenname: Mark E.
  surname: Stackle
  fullname: Stackle, Mark E.
– sequence: 6
  givenname: Michael J.
  surname: Talley
  fullname: Talley, Michael J.
– sequence: 7
  givenname: Michael N.
  surname: Sawka
  fullname: Sawka, Michael N.
– sequence: 8
  givenname: Omer T.
  surname: Inan
  fullname: Inan, Omer T.
BackLink https://www.ncbi.nlm.nih.gov/pubmed/33182638$$D View this record in MEDLINE/PubMed
BookMark eNp9Udtu1DAQjVARvcADP4D8SJGW-hY7fkGqVlxWakUFK_FoTZLJ1lViL3ayaP-Bj8bLllWLEE8ez5w554zOaXHkg8eieMnoWyEMvUiccq4kE0-KEya5nFWc06MH9XFxmtIdpVwIUT0rjoVgFVeiOil-fkOIUPdIvqJPISay8E2I6xBhdH5F5mFY5wGMIW7JF0wYN0iuEdIUcUA_ki5EctluwDc7-M3tNrnQh5VroCfXwbu8uBs4T-bRjbt2v80ad3m_JcsI0wDkJmtlrvS8eNpBn_DF_XtWLD-8X84_za4-f1zML69mjZRsnGluaCfq0oA2reiY6QRn3AipZVWBVjXS_DOmZsA1qI5X1OSCQSmBlbU4KxZ72jbAnV1HN0Dc2gDO_m6EuLIQs9UebYmsyUwKuTbSqLpGJpGJVjWtNEZi5nqz55r8GrY_8nUHQkbtLh17SCeD3-3B66kesG3yzRH6Rw4eT7y7tauwsVoZrTTNBK_vCWL4PmEa7eBSg30PHsOULJeKalXqUmXoq4daB5E_0WfA-R7QxJBSxO6_xi_-wjZuzKGFnU3X_2PjF9QJz2w
CitedBy_id crossref_primary_10_1111_trf_16958
crossref_primary_10_3390_jpm12071168
crossref_primary_10_3390_s22072642
crossref_primary_10_1111_trf_16972
crossref_primary_10_3390_bioengineering10050612
crossref_primary_10_1097_TA_0000000000004385
crossref_primary_10_3390_s22020442
crossref_primary_10_1111_trf_16494
crossref_primary_10_3390_math10091397
crossref_primary_10_1111_trf_16498
crossref_primary_10_1097_SHK_0000000000002260
crossref_primary_10_3390_bios14020061
crossref_primary_10_1007_s10877_024_01166_x
crossref_primary_10_2196_27466
crossref_primary_10_1016_j_burnso_2022_06_003
crossref_primary_10_1063_5_0148820
crossref_primary_10_1093_milmed_usad130
crossref_primary_10_1371_journal_pone_0318290
crossref_primary_10_3390_bioengineering10101226
crossref_primary_10_1097_JTN_0000000000000608
crossref_primary_10_1109_JBHI_2021_3068619
crossref_primary_10_3389_fphys_2021_784413
crossref_primary_10_1038_s41598_021_96640_w
crossref_primary_10_3390_s21175877
crossref_primary_10_3390_s21237803
crossref_primary_10_3390_bios12020133
crossref_primary_10_1016_j_injury_2022_09_036
Cites_doi 10.1109/MEMB.2003.1213624
10.1007/s11906-017-0769-3
10.1097/TA.0b013e31829246c7
10.1109/JSSC.2011.2179451
10.1016/j.ajem.2020.05.012
10.1097/TA.0b013e3182aa811a
10.1213/ANE.0b013e3182124c0e
10.1007/s10286-011-0151-5
10.3357/ASEM.3204.2012
10.1109/IEMBS.2006.260359
10.14814/phy2.13895
10.1002/admt.201901122
10.1109/TBME.2016.2600945
10.1097/BCR.0000000000000178
10.1080/10903120500255891
10.1016/S0039-6109(01)80006-2
10.1097/01.ta.0000196663.34175.33
10.1093/milmed/149.2.55
10.1016/j.bpa.2014.08.002
10.1016/j.cardfail.2020.05.014
10.1109/JBHI.2019.2931348
10.1097/TA.0000000000001837
10.1097/TA.0000000000001511
10.1002/adma.201502535
10.1097/SHK.0000000000000077
10.1097/SHK.0000000000000178
10.1016/S0008-6363(98)00067-4
10.1097/TA.0000000000000423
10.1038/s41551-018-0287-x
10.1186/s13613-018-0436-0
10.1038/ncomms11650
10.1097/ALN.0000000000002374
10.3357/AMHP.5460.2019
10.1097/TA.0000000000002586
10.1097/SHK.0000000000000480
10.1056/NEJM199410273311701
10.1152/ajpheart.00420.2018
10.1097/TA.0b013e31829b01db
10.1088/0967-3334/33/9/1491
10.1016/j.ajem.2018.04.068
10.1038/s41591-020-0792-9
10.1007/s10439-014-1037-1
10.1097/SHK.0000000000000559
10.1152/japplphysiol.00264.2017
10.1002/admt.201900117
10.1152/japplphysiol.00640.2013
10.1097/01.ede.0000147512.81966.ba
10.1109/JSEN.2016.2573269
10.1109/IEMBS.2007.4352596
10.1109/JBHI.2014.2327194
10.1016/j.amjsurg.2006.08.034
10.1115/1.4033833
10.1097/ALN.0b013e31816c89e1
10.1109/JBHI.2014.2361732
10.1016/j.wem.2017.02.001
10.3390/s20030680
10.1093/milmed/usaa197
10.5772/7848
10.1213/ANE.0b013e31822773ec
10.1152/japplphysiol.00668.2013
10.1097/SHK.0000000000000632
10.1097/SHK.0000000000000647
10.1126/sciadv.1601185
10.1177/1535370217694099
10.1097/SHK.0000000000001034
10.1152/japplphysiol.00298.2017
10.1038/s41746-019-0117-x
10.1213/01.ane.0000269512.82836.c9
10.1109/TBME.2020.3014040
10.1364/AO.46.001754
10.1109/TITB.2010.2042607
10.1097/TA.0000000000002649
10.1097/TA.0000000000002605
10.1126/sciadv.abb1708
10.1002/admt.202000347
10.1002/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO;2-3
10.1002/cphy.c200016
10.14814/phy2.12705
10.1109/TBME.2009.2018831
10.1111/trf.15632
10.1038/s41598-019-46823-3
10.1161/01.HYP.13.6.647
10.3390/s140101039
10.1097/TA.0000000000002648
10.1016/j.ccc.2014.08.007
10.1038/ncomms2832
10.1097/SHK.0000000000000323
10.1109/TBCAS.2011.2167717
10.1007/s10916-010-9505-0
10.55460/DPOC-JWIY
10.1007/s00068-019-01140-2
10.1109/JBHI.2020.3021532
10.55460/SFRB-RGN9
10.1152/ajpregu.00304.2015
10.1097/SHK.0000000000000959
10.1097/00003246-199302000-00012
10.1097/TA.0000000000001430
10.3390/electronics3020282
10.1109/TBME.2012.2186809
10.1097/ALN.0000000000002300
10.1097/MCC.0b013e32836091ae
10.1186/s13049-018-0567-1
10.1161/CIRCHEARTFAILURE.117.004313
10.1097/TA.0000000000001474
10.1007/s10115-004-0154-9
10.55460/B3NN-SY8Y
10.1097/MBP.0000000000000155
10.1097/CNQ.0b013e318255d6b3
10.1097/SHK.0000000000001367
10.1093/milmed/usy252
10.1166/sl.2007.225
10.1109/TBCAS.2020.2995810
10.1213/ANE.0000000000004121
ContentType Journal Article
Copyright 2020 by the authors. 2020
Copyright_xml – notice: 2020 by the authors. 2020
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
5PM
ADTOC
UNPAY
DOA
DOI 10.3390/s20226413
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
PubMed Central (Full Participant titles)
Unpaywall for CDI: Periodical Content
Unpaywall
DOAJ Directory of Open Access Journals
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList
MEDLINE - Academic
MEDLINE
CrossRef

Database_xml – sequence: 1
  dbid: DOA
  name: DOAJ Directory of Open Access Journals
  url: https://www.doaj.org/
  sourceTypes: Open Website
– sequence: 2
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 3
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
– sequence: 4
  dbid: UNPAY
  name: Unpaywall
  url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/
  sourceTypes: Open Access Repository
DeliveryMethod fulltext_linktorsrc
Discipline Engineering
EISSN 1424-8220
ExternalDocumentID oai_doaj_org_article_5e1c3996e279496bbe14e13d6cd4994e
10.3390/s20226413
PMC7697670
33182638
10_3390_s20226413
Genre Journal Article
Review
GrantInformation_xml – fundername: U.S. Army Medical Research and Development Command and the Congressionally Directed Medical Research Program
  grantid: DM180240
GroupedDBID ---
123
2WC
53G
5VS
7X7
88E
8FE
8FG
8FI
8FJ
AADQD
AAHBH
AAYXX
ABDBF
ABUWG
ACUHS
ADBBV
ADMLS
AENEX
AFKRA
AFZYC
ALMA_UNASSIGNED_HOLDINGS
BENPR
BPHCQ
BVXVI
CCPQU
CITATION
CS3
D1I
DU5
E3Z
EBD
ESX
F5P
FYUFA
GROUPED_DOAJ
GX1
HH5
HMCUK
HYE
KQ8
L6V
M1P
M48
MODMG
M~E
OK1
OVT
P2P
P62
PHGZM
PHGZT
PIMPY
PJZUB
PPXIY
PQQKQ
PROAC
PSQYO
RNS
RPM
TUS
UKHRP
XSB
~8M
ALIPV
CGR
CUY
CVF
ECM
EIF
NPM
7X8
PUEGO
5PM
ADRAZ
ADTOC
IAO
IPNFZ
ITC
RIG
UNPAY
ID FETCH-LOGICAL-c441t-7290f3b59a79d3f19f32129347488a76be029399b1a27a6f280927a1a54a15b3
IEDL.DBID M48
ISSN 1424-8220
IngestDate Fri Oct 03 12:53:29 EDT 2025
Sun Oct 26 03:44:03 EDT 2025
Tue Sep 30 16:56:00 EDT 2025
Fri Sep 05 07:35:28 EDT 2025
Mon Jul 21 05:52:13 EDT 2025
Thu Oct 16 04:43:25 EDT 2025
Thu Apr 24 23:09:40 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 22
Keywords physiology
vital signs
compensatory reserve
wearable sensors
medical monitoring
Language English
License Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
cc-by
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c441t-7290f3b59a79d3f19f32129347488a76be029399b1a27a6f280927a1a54a15b3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
ObjectType-Review-3
content type line 23
ORCID 0000-0001-9155-3556
0000-0001-9246-0554
OpenAccessLink http://journals.scholarsportal.info/openUrl.xqy?doi=10.3390/s20226413
PMID 33182638
PQID 2460765756
PQPubID 23479
ParticipantIDs doaj_primary_oai_doaj_org_article_5e1c3996e279496bbe14e13d6cd4994e
unpaywall_primary_10_3390_s20226413
pubmedcentral_primary_oai_pubmedcentral_nih_gov_7697670
proquest_miscellaneous_2460765756
pubmed_primary_33182638
crossref_primary_10_3390_s20226413
crossref_citationtrail_10_3390_s20226413
PublicationCentury 2000
PublicationDate 20201110
PublicationDateYYYYMMDD 2020-11-10
PublicationDate_xml – month: 11
  year: 2020
  text: 20201110
  day: 10
PublicationDecade 2020
PublicationPlace Switzerland
PublicationPlace_xml – name: Switzerland
PublicationTitle Sensors (Basel, Switzerland)
PublicationTitleAlternate Sensors (Basel)
PublicationYear 2020
Publisher MDPI
MDPI AG
Publisher_xml – name: MDPI
– name: MDPI AG
References ref_93
Liu (ref_96) 2016; 2
Booth (ref_2) 1977; 70
ref_14
Kendale (ref_46) 2018; 129
Koons (ref_66) 2020; 89
Moulton (ref_30) 2013; 75
Thiele (ref_48) 2011; 113
Spigulis (ref_103) 2007; 46
ref_95
Imani (ref_98) 2016; 7
Li (ref_116) 2012; 33
Wo (ref_27) 1993; 21
ref_15
Inan (ref_94) 2018; 11
Maeda (ref_79) 2011; 35
Digiglio (ref_106) 2014; 42
Muniz (ref_67) 2013; 75
Mulder (ref_127) 2019; 90
Parks (ref_29) 2006; 192
Li (ref_78) 2012; 6
Bruijns (ref_28) 2013; 74
Griggs (ref_10) 2018; 26
Schauer (ref_123) 2019; 37
Howard (ref_38) 2016; 46
Shelley (ref_77) 2007; 105
Carter (ref_37) 2016; 4
Inan (ref_91) 2015; 19
Craven (ref_125) 2015; 19
Schisterman (ref_62) 2005; 16
Bickell (ref_9) 1994; 331
Holder (ref_51) 2015; 31
Janak (ref_39) 2015; 44
Howard (ref_31) 2016; 310
Butler (ref_126) 2014; 14
Thiele (ref_19) 2011; 113
ref_75
Convertino (ref_36) 1999; 6
Convertino (ref_23) 2017; 82
Benov (ref_69) 2020; 89
Schiller (ref_54) 2018; 50
ref_82
Convertino (ref_55) 2018; 124
Wang (ref_88) 2018; 2
Schwartz (ref_87) 2013; 4
Boutry (ref_97) 2015; 27
Asada (ref_80) 2003; 22
ref_86
ref_85
Zia (ref_90) 2020; 6
Wenner (ref_58) 2018; 85
Chen (ref_124) 2012; 47
Holcomb (ref_5) 2005; 59
Kaisti (ref_105) 2019; 2
Inan (ref_114) 2010; 57
Biswas (ref_83) 2020; 5
Engelke (ref_35) 1996; 271
Benov (ref_68) 2017; 83
Johnson (ref_60) 2018; 49
Chew (ref_40) 2013; 19
Tamura (ref_104) 2014; 3
Eastridge (ref_13) 2011; 71
Convertino (ref_21) 2013; 115
Bellamy (ref_12) 1984; 149
Convertino (ref_25) 2015; 44
Tavakolian (ref_89) 2014; 41
Schlotman (ref_57) 2019; 316
Schauer (ref_3) 2019; 184
Parati (ref_74) 1989; 13
Convertino (ref_41) 2012; 83
Karmer (ref_120) 2008; 64
Chung (ref_81) 2020; 26
Libert (ref_121) 2018; 8
Convertino (ref_20) 2020; 89
Shade (ref_32) 2014; 116
Keogh (ref_118) 2005; 7
Stewart (ref_71) 2016; 46
Etemadi (ref_92) 2017; 124
Teichmann (ref_100) 2014; 14
Reisner (ref_53) 2008; 108
Yang (ref_112) 2016; 16
Youden (ref_33) 1950; 3
Wenner (ref_59) 2018; 85
Charlari (ref_1) 2013; 35
Convertino (ref_34) 2012; 22
Javaid (ref_111) 2017; 64
ref_117
Kim (ref_47) 2016; 21
ref_119
Bighamian (ref_122) 2016; 138
Poh (ref_108) 2010; 14
Moulton (ref_65) 2017; 83
Convertino (ref_24) 2011; 71
Ball (ref_8) 2015; 15
Hametner (ref_44) 2017; 19
Eastridge (ref_16) 2007; 63
ref_110
Huang (ref_11) 2017; 7
Schiller (ref_56) 2017; 242
Stewart (ref_72) 2015; 36
Schlotman (ref_63) 2020; 89
Stewart (ref_70) 2016; 16
Wang (ref_76) 2007; 5
Sel (ref_99) 2020; 14
Keenan (ref_7) 2017; 28
Hossein (ref_107) 2019; 9
Koons (ref_17) 2020; 53
Davies (ref_43) 2020; 130
McManus (ref_6) 2005; 9
Imholz (ref_73) 1998; 38
ref_109
Convertino (ref_18) 2020; 60
Orlinsky (ref_26) 2001; 81
Hatib (ref_45) 2018; 129
ref_102
Convertino (ref_22) 2016; 45
ref_101
Orphanidou (ref_115) 2014; 19
Nadler (ref_64) 2014; 42
Stewart (ref_61) 2014; 77
Convertino (ref_42) 2006; 61
ref_49
Westerhof (ref_50) 2018; 6
Han (ref_84) 2020; 5
ref_4
Esper (ref_52) 2014; 28
Inan (ref_113) 2012; 59
References_xml – volume: 22
  start-page: 28
  year: 2003
  ident: ref_80
  article-title: Mobile monitoring with wearable photoplethysmographic biosensors
  publication-title: IEEE Eng. Med. Biol. Mag.
  doi: 10.1109/MEMB.2003.1213624
– volume: 19
  start-page: 73
  year: 2017
  ident: ref_44
  article-title: Pulse Waveform Analysis: Is it ready for prime time?
  publication-title: Curr. Hypertens. Rep.
  doi: 10.1007/s11906-017-0769-3
– volume: 74
  start-page: 1432
  year: 2013
  ident: ref_28
  article-title: The value of traditional vital signs, shock index, and age-based markers in predicting trauma mortality
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0b013e31829246c7
– volume: 47
  start-page: 744
  year: 2012
  ident: ref_124
  article-title: Design and analysis of a hardware-efficient compressed sensing architecture for data compression in wireless sensors
  publication-title: IEEE J. Solid State Circuits
  doi: 10.1109/JSSC.2011.2179451
– ident: ref_15
  doi: 10.1016/j.ajem.2020.05.012
– volume: 75
  start-page: 1053
  year: 2013
  ident: ref_30
  article-title: Running on empty? The compensatory reserve index
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0b013e3182aa811a
– volume: 113
  start-page: 284
  year: 2011
  ident: ref_19
  article-title: The physiologic implications of isolated alpha(1) adrenergic stimulation
  publication-title: Anesth. Analg.
  doi: 10.1213/ANE.0b013e3182124c0e
– volume: 22
  start-page: 123
  year: 2012
  ident: ref_34
  article-title: Autonomic mechanisms associated with heart rate and vasoconstrictor reserves
  publication-title: Clin. Auton. Res.
  doi: 10.1007/s10286-011-0151-5
– volume: 83
  start-page: 614
  year: 2012
  ident: ref_41
  article-title: Blood pressure measurement for accurate assessment of patient status in emergency medical settings
  publication-title: Aviat. Space Environ. Med.
  doi: 10.3357/ASEM.3204.2012
– ident: ref_110
  doi: 10.1109/IEMBS.2006.260359
– volume: 71
  start-page: S25
  year: 2011
  ident: ref_24
  article-title: Use of advanced machine-learning techniques for non-invasive monitoring of hemorrhage
  publication-title: J. Trauma
– volume: 6
  start-page: e13895
  year: 2018
  ident: ref_50
  article-title: Detecting central hypovolemia in simulated hypovolemic shock by automated feature extraction with principal component analysis
  publication-title: Physiol. Rep.
  doi: 10.14814/phy2.13895
– volume: 5
  start-page: 1901122
  year: 2020
  ident: ref_84
  article-title: Pulse oximetry using organic optoelectronics under ambient light
  publication-title: Adv. Mater. Technol.
  doi: 10.1002/admt.201901122
– volume: 64
  start-page: 1277
  year: 2017
  ident: ref_111
  article-title: Quantifying and reducing Motion artifacts in wearable seismocardiogram measurements during walking to assess left ventricular health
  publication-title: IEEE Trans. Biomed. Eng.
  doi: 10.1109/TBME.2016.2600945
– volume: 36
  start-page: 145
  year: 2015
  ident: ref_72
  article-title: A noninvasive computational method for fluid resuscitation monitoring in pediatric burns: A preliminary report
  publication-title: J. Burn Care Res.
  doi: 10.1097/BCR.0000000000000178
– volume: 9
  start-page: 423
  year: 2005
  ident: ref_6
  article-title: Radial pulse character relationships to systolic blood pressure and trauma outcomes
  publication-title: Prehospital Emerg. Care
  doi: 10.1080/10903120500255891
– volume: 81
  start-page: 1217
  year: 2001
  ident: ref_26
  article-title: Current controversies in shock and resuscitation
  publication-title: Surg. Clin. N. Am.
  doi: 10.1016/S0039-6109(01)80006-2
– volume: 61
  start-page: 629
  year: 2006
  ident: ref_42
  article-title: Arterial pulse pressure and its association with reduced stroke volume during progressive central hypovolemia
  publication-title: J. Trauma
  doi: 10.1097/01.ta.0000196663.34175.33
– volume: 70
  start-page: 793
  year: 1977
  ident: ref_2
  article-title: A short history of blood pressure measurement
  publication-title: Proc. R. Soc. Med.
– volume: 149
  start-page: 55
  year: 1984
  ident: ref_12
  article-title: The causes of death in conventional land warfare: Implications for combat casualty care research
  publication-title: Mil. Med.
  doi: 10.1093/milmed/149.2.55
– volume: 28
  start-page: 363
  year: 2014
  ident: ref_52
  article-title: Arterial waveform analysis
  publication-title: Best Pract. Res. Clin. Anaesthesiol.
  doi: 10.1016/j.bpa.2014.08.002
– ident: ref_95
  doi: 10.1016/j.cardfail.2020.05.014
– ident: ref_117
  doi: 10.1109/JBHI.2019.2931348
– volume: 85
  start-page: S77
  year: 2018
  ident: ref_59
  article-title: Measurement of compensatory reserve predicts racial differences in tolerance to simulated hemorrhage in women
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000001837
– volume: 83
  start-page: S104
  year: 2017
  ident: ref_65
  article-title: Validation of a noninvasive monitor to continuously trend individual responses to hypovolemia
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000001511
– volume: 27
  start-page: 6954
  year: 2015
  ident: ref_97
  article-title: A sensitive and biodegradable pressure sensor array for cardiovascular monitoring
  publication-title: Adv. Mater.
  doi: 10.1002/adma.201502535
– volume: 6
  start-page: 73
  year: 1999
  ident: ref_36
  article-title: G-Factor as a tool in basic research: Mechanisms of orthostatic tolerance
  publication-title: J. Gravit. Physiol.
– volume: 41
  start-page: 91
  year: 2014
  ident: ref_89
  article-title: Precordial vibrations provide noninvasive detection of early-stage hemorrhage
  publication-title: Shock
  doi: 10.1097/SHK.0000000000000077
– volume: 42
  start-page: 93
  year: 2014
  ident: ref_64
  article-title: The value of non-invasive mesurement of the compensatory reserve index in monitoring and triage of patients experiencing minimal blood loss
  publication-title: Shock
  doi: 10.1097/SHK.0000000000000178
– volume: 85
  start-page: S77
  year: 2018
  ident: ref_58
  article-title: Differences in compensatory response to progressive reductions in central blood volume of African American and Caucasian women
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000001837
– volume: 38
  start-page: 605
  year: 1998
  ident: ref_73
  article-title: Fifteen years experience with finger arterial pressure monitoring
  publication-title: Cardiovasc. Res.
  doi: 10.1016/S0008-6363(98)00067-4
– volume: 59
  start-page: 821
  year: 2005
  ident: ref_5
  article-title: Manual vital signs reliably predict need for life-saving intervention in trauma patients
  publication-title: J. Trauma
– volume: 77
  start-page: 892
  year: 2014
  ident: ref_61
  article-title: Detection of low-volume blood loss: The compensatory reserve index versus traditional vital signs
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000000423
– volume: 19
  start-page: 832
  year: 2014
  ident: ref_115
  article-title: Signal-quality indices for the electrocardiogram and photoplethysmogram: Derivation and applications to wireless monitoring
  publication-title: IEEE J. Biomed. Health Inform.
– volume: 2
  start-page: 687
  year: 2018
  ident: ref_88
  article-title: Monitoring of the central blood pressure waveform via a conformal ultrasonic device
  publication-title: Nat. Biomed. Eng.
  doi: 10.1038/s41551-018-0287-x
– volume: 8
  start-page: 89
  year: 2018
  ident: ref_121
  article-title: Performance of closed-loop resuscitation of haemorrhagic shock with fluid alone or in combination with norepinephrine: An experimental study
  publication-title: Ann. Intensive Care
  doi: 10.1186/s13613-018-0436-0
– volume: 7
  start-page: 1
  year: 2016
  ident: ref_98
  article-title: A wearable chemical–electrophysiological hybrid biosensing system for real-time health and fitness monitoring
  publication-title: Nat. Commun.
  doi: 10.1038/ncomms11650
– volume: 129
  start-page: 675
  year: 2018
  ident: ref_46
  article-title: Supervised machine-learning predictive analytics for prediction of postinduction hypotension
  publication-title: Anesthesiology
  doi: 10.1097/ALN.0000000000002374
– volume: 90
  start-page: 1009
  year: 2019
  ident: ref_127
  article-title: Exercise-induced changes in compensatory reserve and heart rate complexity
  publication-title: Aerosp. Med. Hum. Perform.
  doi: 10.3357/AMHP.5460.2019
– volume: 89
  start-page: S169
  year: 2020
  ident: ref_20
  article-title: Validating clinical threshold values for a dashboard view of the compensatory reserve measurement for hemorrhage detection
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000002586
– volume: 44
  start-page: 548
  year: 2015
  ident: ref_39
  article-title: Predictors of the onset of hemodynamic decompensation during progressive central hypovolemia: Comparison of the peripheral perfusion index, pulse pressure variability, and compensatory reserve index
  publication-title: Shock
  doi: 10.1097/SHK.0000000000000480
– ident: ref_86
– volume: 331
  start-page: 1105
  year: 1994
  ident: ref_9
  article-title: Immediate versus delayed fluid resuscitation for hypotensive patients with penetrating torso injuries
  publication-title: N. Engl. J. Med.
  doi: 10.1056/NEJM199410273311701
– volume: 316
  start-page: H609
  year: 2019
  ident: ref_57
  article-title: Differentiating compensatory mechanisms associated with low tolerance to central hypovolemia in women
  publication-title: Am. J. Physiol. Heart Circ. Physiol.
  doi: 10.1152/ajpheart.00420.2018
– volume: 64
  start-page: S333
  year: 2008
  ident: ref_120
  article-title: Closed-loop control of fluid therapy for treatment of hypovolemia
  publication-title: J. Trauma
– volume: 75
  start-page: S184
  year: 2013
  ident: ref_67
  article-title: Promoting early diagnosis of hemodynamic instability during simulated hemorrhage with the use of a real-time decision-assist algorithm
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0b013e31829b01db
– volume: 33
  start-page: 1491
  year: 2012
  ident: ref_116
  article-title: Dynamic time warping and machine learning for signal quality assessment of pulsatile signals
  publication-title: Physiol. Meas.
  doi: 10.1088/0967-3334/33/9/1491
– volume: 7
  start-page: 17
  year: 2017
  ident: ref_11
  article-title: Mortality outcomes in trauma patients undergoing prehospital red blood cell transfusion: A systematic literature review
  publication-title: Int. J. Burns Trauma
– volume: 37
  start-page: 94
  year: 2019
  ident: ref_123
  article-title: An analysis of casualties presenting to military emergency departments in Iraq and Afghanistan
  publication-title: Am. J. Emerg. Med.
  doi: 10.1016/j.ajem.2018.04.068
– volume: 26
  start-page: 418
  year: 2020
  ident: ref_81
  article-title: Skin-interfaced biosensors for advanced wireless physiological monitoring in neonatal and pediatric intensive-care units
  publication-title: Nat. Med.
  doi: 10.1038/s41591-020-0792-9
– volume: 42
  start-page: 2278
  year: 2014
  ident: ref_106
  article-title: Microflotronic arterial tonometry for continuous wearable non-invasive hemodynamic monitoring
  publication-title: Ann. Biomed. Eng.
  doi: 10.1007/s10439-014-1037-1
– volume: 45
  start-page: 580
  year: 2016
  ident: ref_22
  article-title: The compensatory reserve for early and accurate prediction of hemodynamic compromise: A review of the underlying physiology
  publication-title: Shock
  doi: 10.1097/SHK.0000000000000559
– volume: 124
  start-page: 442
  year: 2018
  ident: ref_55
  article-title: Wearable compensatory reserve measurement for hypovolemia sensing
  publication-title: J. Appl. Physiol.
  doi: 10.1152/japplphysiol.00264.2017
– ident: ref_82
  doi: 10.1002/admt.201900117
– volume: 116
  start-page: 406
  year: 2014
  ident: ref_32
  article-title: Validation of lower body negative pressure as an experimental model of hemorrhage
  publication-title: J. Appl. Physiol.
  doi: 10.1152/japplphysiol.00640.2013
– volume: 16
  start-page: 73
  year: 2005
  ident: ref_62
  article-title: Optimal cut-point and its corresponding Youden Index to discriminate individuals using pooled blood samples
  publication-title: Epidemiology
  doi: 10.1097/01.ede.0000147512.81966.ba
– volume: 16
  start-page: 5702
  year: 2016
  ident: ref_112
  article-title: Motion artifact cancellation of seismocardiographic recording from moving subjects
  publication-title: IEEE Sens. J.
  doi: 10.1109/JSEN.2016.2573269
– ident: ref_109
  doi: 10.1109/IEMBS.2007.4352596
– volume: 19
  start-page: 529
  year: 2015
  ident: ref_125
  article-title: Compressed sensing for bioelectric signals: A review
  publication-title: IEEE J. Biomed. Health Inform.
  doi: 10.1109/JBHI.2014.2327194
– volume: 63
  start-page: 291
  year: 2007
  ident: ref_16
  article-title: Hypotension begins at 110 mm Hg: Redefining “hypotension” with data
  publication-title: J. Trauma
– volume: 192
  start-page: 727
  year: 2006
  ident: ref_29
  article-title: Systemic hypotension is a late marker of shock after trauma: A validation study of advanced trauma life support principles in a large national sample
  publication-title: Am. J. Surg.
  doi: 10.1016/j.amjsurg.2006.08.034
– volume: 138
  start-page: 111005
  year: 2016
  ident: ref_122
  article-title: Closed-loop fluid resuscitation control via blood volume estimation
  publication-title: J. Dyn. Syst. Meas. Control
  doi: 10.1115/1.4033833
– volume: 108
  start-page: 950
  year: 2008
  ident: ref_53
  article-title: Utility of the photoplethysmogram in circulatory monitoring
  publication-title: Anesthesiology
  doi: 10.1097/ALN.0b013e31816c89e1
– volume: 19
  start-page: 1414
  year: 2015
  ident: ref_91
  article-title: Ballistocardiography and seismocardiography: A review of recent advances
  publication-title: IEEE J. Biomed. Health Inform.
  doi: 10.1109/JBHI.2014.2361732
– volume: 28
  start-page: S135
  year: 2017
  ident: ref_7
  article-title: Prolonged field care: Beyond the “Golden Hour”
  publication-title: Wilderness Environ. Med.
  doi: 10.1016/j.wem.2017.02.001
– ident: ref_93
  doi: 10.3390/s20030680
– ident: ref_4
  doi: 10.1093/milmed/usaa197
– ident: ref_75
  doi: 10.5772/7848
– volume: 113
  start-page: 766
  year: 2011
  ident: ref_48
  article-title: Arterial waveform analysis for the anesthesiologist: Past, present, and future concepts
  publication-title: Anesth. Analg.
  doi: 10.1213/ANE.0b013e31822773ec
– volume: 115
  start-page: 1196
  year: 2013
  ident: ref_21
  article-title: Estimation of individual-specific progression to impending cardiovascular instability using arterial waveforms
  publication-title: J. Appl. Physiol.
  doi: 10.1152/japplphysiol.00668.2013
– volume: 46
  start-page: 68
  year: 2016
  ident: ref_38
  article-title: Specificity of compensatory reserve and tissue oxygenation as early predictors of tolerance to progressive reductions in central blood volume
  publication-title: Shock
  doi: 10.1097/SHK.0000000000000632
– volume: 46
  start-page: 61
  year: 2016
  ident: ref_71
  article-title: The Compensatory reserve index following injury: Results of a prospective clinical trial
  publication-title: Shock
  doi: 10.1097/SHK.0000000000000647
– volume: 2
  start-page: e1601185
  year: 2016
  ident: ref_96
  article-title: Epidermal mechano-acoustic sensing electronics for cardiovascular diagnostics and human-machine interfaces
  publication-title: Sci. Adv.
  doi: 10.1126/sciadv.1601185
– volume: 242
  start-page: 874
  year: 2017
  ident: ref_56
  article-title: The physiology of blood loss and shock: New insights from a human laboratory model of hemorrhage
  publication-title: Exp. Biol. Med.
  doi: 10.1177/1535370217694099
– volume: 50
  start-page: 71
  year: 2018
  ident: ref_54
  article-title: Comparisons of traditional metabolic markers and compensatory reserve as early predictors of tolerance to central hypovolemia in humans
  publication-title: Shock
  doi: 10.1097/SHK.0000000000001034
– volume: 124
  start-page: 452
  year: 2017
  ident: ref_92
  article-title: Wearable ballistocardiogram and seismocardiogram systems for health and performance
  publication-title: J. Appl. Physiol.
  doi: 10.1152/japplphysiol.00298.2017
– volume: 2
  start-page: 39
  year: 2019
  ident: ref_105
  article-title: Clinical assessment of a non-invasive wearable MEMS pressure sensor array for monitoring of arterial pulse waveform, heart rate and detection of atrial fibrillation
  publication-title: NPJ Digit. Med.
  doi: 10.1038/s41746-019-0117-x
– volume: 105
  start-page: S31
  year: 2007
  ident: ref_77
  article-title: Photoplethysmography: Beyond the calculation of arterial oxygen saturation and heart rate
  publication-title: Anesth. Analg.
  doi: 10.1213/01.ane.0000269512.82836.c9
– ident: ref_119
  doi: 10.1109/TBME.2020.3014040
– volume: 46
  start-page: 1754
  year: 2007
  ident: ref_103
  article-title: Simultaneous recording of skin blood pulsations at different vascular depths by multiwavelength photoplethysmography
  publication-title: Appl. Opt.
  doi: 10.1364/AO.46.001754
– volume: 14
  start-page: 786
  year: 2010
  ident: ref_108
  article-title: Motion-tolerant magnetic earring sensor and wireless earpiece for wearable photoplethysmography
  publication-title: IEEE Trans. Inf. Technol. Biomed.
  doi: 10.1109/TITB.2010.2042607
– volume: 89
  start-page: S146
  year: 2020
  ident: ref_66
  article-title: Compensatory reserve: A novel monitoring capability for early detection of hemorrhage by combat medics
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000002649
– volume: 89
  start-page: S161
  year: 2020
  ident: ref_63
  article-title: Comparisons of measures of compensatory reserve and heart rate variability as early indicators of hemodynamic decompensation in progressive hypovolemia
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000002605
– volume: 6
  start-page: eabb1708
  year: 2020
  ident: ref_90
  article-title: Enabling the assessment of trauma-induced hemorrhage via smart wearable systems
  publication-title: Sci. Adv.
  doi: 10.1126/sciadv.abb1708
– volume: 5
  start-page: 2000347
  year: 2020
  ident: ref_83
  article-title: Integrated soft optoelectronics for wearable health monitoring
  publication-title: Adv. Mater. Technol.
  doi: 10.1002/admt.202000347
– volume: 3
  start-page: 32
  year: 1950
  ident: ref_33
  article-title: Index for rating diagnostic tests
  publication-title: Cancer
  doi: 10.1002/1097-0142(1950)3:1<32::AID-CNCR2820030106>3.0.CO;2-3
– ident: ref_14
  doi: 10.1002/cphy.c200016
– volume: 4
  start-page: e12705
  year: 2016
  ident: ref_37
  article-title: Variability in integration of mechanisms associated with high tolerance to progressive reductions in central blood volume: The compensatory reserve
  publication-title: Physiol. Rep.
  doi: 10.14814/phy2.12705
– volume: 57
  start-page: 722
  year: 2010
  ident: ref_114
  article-title: Adaptive cancellation of floor vibrations in standing ballistocardiogram measurements using a seismic sensor as a noise reference
  publication-title: IEEE Trans. Biomed. Eng.
  doi: 10.1109/TBME.2009.2018831
– volume: 60
  start-page: S150
  year: 2020
  ident: ref_18
  article-title: The compensatory reserve: Potential for accurate individualized goal-directed whole blood resuscitation
  publication-title: Transfusion
  doi: 10.1111/trf.15632
– volume: 271
  start-page: R837
  year: 1996
  ident: ref_35
  article-title: Application of acute maximal exercise to protect orthostatic tolerance after simulated microgravity
  publication-title: Am. J. Physiol.
– volume: 9
  start-page: 10479
  year: 2019
  ident: ref_107
  article-title: Accurate detection of dobutamine-induced haemodynamic changes by kino-cardiography: A randomised double-blind placebo-controlled validation study
  publication-title: Sci. Rep.
  doi: 10.1038/s41598-019-46823-3
– volume: 13
  start-page: 647
  year: 1989
  ident: ref_74
  article-title: Comparison of finger and intra-arterial blood pressure monitoring at rest and during laboratory testing
  publication-title: Hypertension
  doi: 10.1161/01.HYP.13.6.647
– volume: 14
  start-page: 1039
  year: 2014
  ident: ref_100
  article-title: The MAIN Shirt: A textile-integrated magnetic induction sensor array
  publication-title: Sensors
  doi: 10.3390/s140101039
– volume: 89
  start-page: S153
  year: 2020
  ident: ref_69
  article-title: Evaluation of sepsis using compensatory reserve measurement: A prospective clinical trial
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000002648
– volume: 31
  start-page: 133
  year: 2015
  ident: ref_51
  article-title: Using what you get: Dynamic physiologic signatures of critical illness
  publication-title: Crit. Care Clin.
  doi: 10.1016/j.ccc.2014.08.007
– volume: 4
  start-page: 1859
  year: 2013
  ident: ref_87
  article-title: Flexible polymer transistors with high pressure sensitivity for application in electronic skin and health monitoring
  publication-title: Nat. Commun.
  doi: 10.1038/ncomms2832
– volume: 44
  start-page: 27
  year: 2015
  ident: ref_25
  article-title: A novel measurement for accurate assessment of clinical status in patients with significant blood loss: The compensatory reserve
  publication-title: Shock
  doi: 10.1097/SHK.0000000000000323
– volume: 6
  start-page: 269
  year: 2012
  ident: ref_78
  article-title: A wireless reflectance pulse oximeter with digital baseline control for unfiltered photoplethysmograms
  publication-title: IEEE Trans. Biomed. Circuits Syst.
  doi: 10.1109/TBCAS.2011.2167717
– ident: ref_102
– volume: 35
  start-page: 969
  year: 2011
  ident: ref_79
  article-title: Relationship between measurement site and motion artifacts in wearable reflected photoplethysmography
  publication-title: J. Med. Syst.
  doi: 10.1007/s10916-010-9505-0
– volume: 14
  start-page: 30
  year: 2014
  ident: ref_126
  article-title: Fluid resuscitation for hemorrhagic shock in tactical combat casualty care: TCCC Guidelines Change 14-01-2 June 2014
  publication-title: J. Spec. Oper. Med.
  doi: 10.55460/DPOC-JWIY
– ident: ref_49
  doi: 10.1007/s00068-019-01140-2
– ident: ref_101
  doi: 10.1109/JBHI.2020.3021532
– volume: 16
  start-page: 6
  year: 2016
  ident: ref_70
  article-title: The Compensatory Reserve for Early and Accurate Prediction of Hemodynamic Compromise: Case Studies for Clinical Utility in Acute Care and Physical Performance
  publication-title: J. Spec. Oper. Med.
  doi: 10.55460/SFRB-RGN9
– volume: 310
  start-page: R1154
  year: 2016
  ident: ref_31
  article-title: Comparison of comensatory reserve during lower-body negative pressure and hemorrhage in nonhuman primates
  publication-title: Am. J. Physiol. Regul. Integr. Comp. Physiol.
  doi: 10.1152/ajpregu.00304.2015
– volume: 49
  start-page: 295
  year: 2018
  ident: ref_60
  article-title: Compensatory reserve index: Performance of a novel monitoring technology to identify the bleeding trauma patient
  publication-title: Shock
  doi: 10.1097/SHK.0000000000000959
– volume: 21
  start-page: 218
  year: 1993
  ident: ref_27
  article-title: Unreliability of blood pressure and heart rate to evaluate cardiac output in emergency resuscitation and critical illness
  publication-title: Crit. Care Med.
  doi: 10.1097/00003246-199302000-00012
– volume: 82
  start-page: S57
  year: 2017
  ident: ref_23
  article-title: Measuring the compensatory reserve to identify shock
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000001430
– volume: 3
  start-page: 282
  year: 2014
  ident: ref_104
  article-title: Wearable photoplethysmographic sensors—past and present
  publication-title: Electronics
  doi: 10.3390/electronics3020282
– volume: 59
  start-page: 2137
  year: 2012
  ident: ref_113
  article-title: Noninvasive measurement of physiological signals on a modified home bathroom scale
  publication-title: IEEE Trans. Biomed. Eng.
  doi: 10.1109/TBME.2012.2186809
– volume: 129
  start-page: 663
  year: 2018
  ident: ref_45
  article-title: Machine-learning algorithm to predict hypotension based on high-fidelity arterial pressure waveform analysis
  publication-title: Anesthesiology
  doi: 10.1097/ALN.0000000000002300
– volume: 19
  start-page: 234
  year: 2013
  ident: ref_40
  article-title: Haemodynamic monitoring using arterial waveform analysis
  publication-title: Curr. Opin. Crit. Care
  doi: 10.1097/MCC.0b013e32836091ae
– ident: ref_85
– volume: 26
  start-page: 100
  year: 2018
  ident: ref_10
  article-title: Mortality of civilian patients with suspected traumatic haemorrhage receiving pre-hospital transfusion of packed red blood cells compared to pre-hospital crystalloid
  publication-title: Scand. J. Trauma Resusc. Emerg. Med.
  doi: 10.1186/s13049-018-0567-1
– volume: 11
  start-page: e004313
  year: 2018
  ident: ref_94
  article-title: Novel Wearable Seismocardiography and Machine Learning Algorithms Can Assess Clinical Status of Heart Failure Patients
  publication-title: Circ. Heart Fail.
  doi: 10.1161/CIRCHEARTFAILURE.117.004313
– volume: 83
  start-page: S71
  year: 2017
  ident: ref_68
  article-title: The effect of blood transfusion on compensatory reserve: A prospective clinical trial
  publication-title: J. Trauma Acute Care Surg.
  doi: 10.1097/TA.0000000000001474
– volume: 7
  start-page: 358
  year: 2005
  ident: ref_118
  article-title: Exact indexing of dynamic time warping
  publication-title: Knowl. Inf. Syst.
  doi: 10.1007/s10115-004-0154-9
– volume: 15
  start-page: 76
  year: 2015
  ident: ref_8
  article-title: Prolonged field care working group position paper: Prolonged field care capabilities
  publication-title: J. Spec. Oper. Med.
  doi: 10.55460/B3NN-SY8Y
– volume: 21
  start-page: 9
  year: 2016
  ident: ref_47
  article-title: Prediction of hyperdynamic circulation by arterial diastolic reflected waveform analysis in patients undergoing liver transplantation
  publication-title: Blood Press. Monit.
  doi: 10.1097/MBP.0000000000000155
– volume: 71
  start-page: S4
  year: 2011
  ident: ref_13
  article-title: Died of wounds on the battlefield: Causation and implications for improving combat casualty care
  publication-title: J. Trauma
– volume: 35
  start-page: 292
  year: 2013
  ident: ref_1
  article-title: The importance of vital signs in the triage of injured patients
  publication-title: Crit. Care Nurs. Q.
  doi: 10.1097/CNQ.0b013e318255d6b3
– volume: 53
  start-page: 327
  year: 2020
  ident: ref_17
  article-title: Tracking DO2 with compensatory reserve during whole blood resuscitation in baboons
  publication-title: Shock
  doi: 10.1097/SHK.0000000000001367
– volume: 184
  start-page: e154
  year: 2019
  ident: ref_3
  article-title: Prehospital resuscitation performed on hypotensive trauma patients in afghanistan: The prehospital trauma registry experience
  publication-title: Mil. Med.
  doi: 10.1093/milmed/usy252
– volume: 5
  start-page: 450
  year: 2007
  ident: ref_76
  article-title: Design and optimization of an ultra-sensitive piezoresistive accelerometer for continuous respiratory sound monitoring
  publication-title: Sens. Lett.
  doi: 10.1166/sl.2007.225
– volume: 14
  start-page: 757
  year: 2020
  ident: ref_99
  article-title: ImpediBands: Body coupled bio-impedance patches for physiological sensing proof of concept
  publication-title: IEEE Trans. Biomed. Circuits Syst.
  doi: 10.1109/TBCAS.2020.2995810
– volume: 130
  start-page: 352
  year: 2020
  ident: ref_43
  article-title: Ability of an arterial waveform analysis-derived hypotension prediction index to predict future hypotensive events in surgical patients
  publication-title: Anesth. Analg.
  doi: 10.1213/ANE.0000000000004121
SSID ssj0023338
Score 2.476547
SecondaryResourceType review_article
Snippet Vital signs historically served as the primary method to triage patients and resources for trauma and emergency care, but have failed to provide...
SourceID doaj
unpaywall
pubmedcentral
proquest
pubmed
crossref
SourceType Open Website
Open Access Repository
Aggregation Database
Index Database
Enrichment Source
StartPage 6413
SubjectTerms Algorithms
compensatory reserve
Hemodynamics
Hemorrhage - diagnosis
Humans
Hypovolemia - diagnosis
medical monitoring
Monitoring, Physiologic - instrumentation
physiology
Review
vital signs
Wearable Electronic Devices
wearable sensors
Wounds and Injuries - diagnosis
SummonAdditionalLinks – databaseName: DOAJ Directory of Open Access Journals
  dbid: DOA
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwrV1Jj9UwDLbQXIADYqdsCsuBSzXZmrwcATEakAYhMYi5VUmbiEGPvtFbQPMf-NHY6cJ7YhAXbl1cpa3t-nPifgZ4jiBeKx1EaRO3pU4qlp7LWIZopaq4TCnRPOTRe3P4Sb87qU62Wn1RTVhPD9y_uP0qigaDqIkSLceZEKLQUajWNC2CdR3p68tnbkymhlRLYebV8wgpTOr3V5jiY-QXaif6ZJL-i5DlnwWSlzfdmT__4efzrehzcB2uDbCRvexv9wZcit1NuLpFJngLfn5Go6UfodhHTE0XyxV7SxyVmacYBRh5Pp7Iq-qMCu6W3yM7-j1FyBC-stxkuSHxXBo6fhlZ7_o0EDvt2NgfYX6OY3zF61uGMW_zzbMPPU3r6jYcH7w5fn1YDr0WygYB0Zo62vKkQuW8da1KwiUlCQpoix7urQmR455zQXhpvUlyxh1uCF9pL6qg7sBet-jiPWBWNla1ETXlopbJ-GA8dSbiLW-JLK-AF6MK6mbgIad2GPMa8xHSVj1pq4Cnk-hZT75xkdAr0uMkQHzZ-QBaUT1YUf0vKyrgyWgFNfoXLZr4Li42q1pqwy2tTpkC7vZWMQ2lFGVnalaA3bGXnXvZPdOdfskc3tYgDrS8gGeTZf39Ee__j0d8AFckzRXkEsaHsLdebuIjBFTr8Dj7zi-J-iC4
  priority: 102
  providerName: Directory of Open Access Journals
– databaseName: Unpaywall
  dbid: UNPAY
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Zb9QwELbQ9gF44D7CJXM88JKur9ibJ1QQVUFqVYlWlKfITmxYWLKrPYrKb-BHM-Mc7EKRkJDykGMS28p4_I09_oaQZwDilVSOpyYwk6ogfWqZ8KnzRsiMiRACzkPuH-i9Y_X2JDtZ28WPYZXgio-jkcZdWCmMYGyIhxhqsLjDWRVenLZzSRzAONf5SIPTvqUzQOMDsnV8cLjzIW4qat9uCIUkePfDBfj6Aj-zMQxFtv7zIOafkZIXV_XMnn2zk8naMLR7ldiuAU30yZft1dJtl99_43b8nxZeI1dajEp3GqW6Ti74-ga5vMZceJP8eA89BHdd0XfgB0_nC_oGCTEjKTIIUDQz8CAu4VOM7puferr_az6SAlamMaNzieIxDrUzw7SxM1gQHde0S8YwOYMyPsP7FYUBdvXV0sOGE3Zxixztvj56tZe2iR3SEtDXEtPnsiBdlluTVzLwPEiBuEMZMCfWaOcZXOW541YYq4MYsRxOuM2U5ZmTt8mgntb-LqFGlEZWXjuXeyWCtk5bTIPEKlYhM19Cnne_uShb0nPMvTEpwPlBjSh6jUjIk1501jB9nCf0EnWlF0By7nhjOv9YtH29yDwvofbaCzB2OdTNc-W5rHRZgX-pfEIed5pWQGfGFRpb--lqUQilmcGlMJ2QO43m9UVJia6gHCXEbOjkRl02n9TjT5Ew3GgAnYYl5GmvvX9v4r1_krpPLgmceYgBkQ_IYDlf-YcAz5buUdsDfwL3ajZN
  priority: 102
  providerName: Unpaywall
Title Wearable Sensors Incorporating Compensatory Reserve Measurement for Advancing Physiological Monitoring in Critically Injured Trauma Patients
URI https://www.ncbi.nlm.nih.gov/pubmed/33182638
https://www.proquest.com/docview/2460765756
https://pubmed.ncbi.nlm.nih.gov/PMC7697670
https://www.mdpi.com/1424-8220/20/22/6413/pdf?version=1605169860
https://doaj.org/article/5e1c3996e279496bbe14e13d6cd4994e
UnpaywallVersion publishedVersion
Volume 20
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVFSB
  databaseName: Free Full-Text Journals in Chemistry
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: HH5
  dateStart: 20010101
  isFulltext: true
  titleUrlDefault: http://abc-chemistry.org/
  providerName: ABC ChemistRy
– providerCode: PRVAFT
  databaseName: Open Access Digital Library
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: KQ8
  dateStart: 20010101
  isFulltext: true
  titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html
  providerName: Colorado Alliance of Research Libraries
– providerCode: PRVAFT
  databaseName: Open Access Digital Library
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: KQ8
  dateStart: 20030101
  isFulltext: true
  titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html
  providerName: Colorado Alliance of Research Libraries
– providerCode: PRVAON
  databaseName: DOAJ Directory of Open Access Journals
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: DOA
  dateStart: 20010101
  isFulltext: true
  titleUrlDefault: https://www.doaj.org/
  providerName: Directory of Open Access Journals
– providerCode: PRVEBS
  databaseName: Academic Search Ultimate
  customDbUrl: https://search.ebscohost.com/login.aspx?authtype=ip,shib&custid=s3936755&profile=ehost&defaultdb=asn
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: ABDBF
  dateStart: 20081201
  isFulltext: true
  titleUrlDefault: https://search.ebscohost.com/direct.asp?db=asn
  providerName: EBSCOhost
– providerCode: PRVEBS
  databaseName: Inspec with Full Text
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: ADMLS
  dateStart: 20081201
  isFulltext: true
  titleUrlDefault: https://www.ebsco.com/products/research-databases/inspec-full-text
  providerName: EBSCOhost
– providerCode: PRVFQY
  databaseName: GFMER Free Medical Journals
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: GX1
  dateStart: 20010101
  isFulltext: true
  titleUrlDefault: http://www.gfmer.ch/Medical_journals/Free_medical.php
  providerName: Geneva Foundation for Medical Education and Research
– providerCode: PRVFQY
  databaseName: GFMER Free Medical Journals
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: GX1
  dateStart: 0
  isFulltext: true
  titleUrlDefault: http://www.gfmer.ch/Medical_journals/Free_medical.php
  providerName: Geneva Foundation for Medical Education and Research
– providerCode: PRVHPJ
  databaseName: ROAD: Directory of Open Access Scholarly Resources
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: M~E
  dateStart: 20010101
  isFulltext: true
  titleUrlDefault: https://road.issn.org
  providerName: ISSN International Centre
– providerCode: PRVAQN
  databaseName: PubMed Central
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: RPM
  dateStart: 20030101
  isFulltext: true
  titleUrlDefault: https://www.ncbi.nlm.nih.gov/pmc/
  providerName: National Library of Medicine
– providerCode: PRVPQU
  databaseName: Health & Medical Collection
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: 7X7
  dateStart: 20010101
  isFulltext: true
  titleUrlDefault: https://search.proquest.com/healthcomplete
  providerName: ProQuest
– providerCode: PRVPQU
  databaseName: ProQuest Central
  customDbUrl: http://www.proquest.com/pqcentral?accountid=15518
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: BENPR
  dateStart: 20010101
  isFulltext: true
  titleUrlDefault: https://www.proquest.com/central
  providerName: ProQuest
– providerCode: PRVPQU
  databaseName: ProQuest Technology Collection
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: 8FG
  dateStart: 20010101
  isFulltext: true
  titleUrlDefault: https://search.proquest.com/technologycollection1
  providerName: ProQuest
– providerCode: PRVFZP
  databaseName: Scholars Portal Open Access Journals
  customDbUrl:
  eissn: 1424-8220
  dateEnd: 20250930
  omitProxy: true
  ssIdentifier: ssj0023338
  issn: 1424-8220
  databaseCode: M48
  dateStart: 20030101
  isFulltext: true
  titleUrlDefault: http://journals.scholarsportal.info
  providerName: Scholars Portal
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Lj9MwEB4tuxIsB8Sb8KjM48AlkNiOvTkgtIu2LEitKtiKcoqcxIFFIV2SFuh_4EczkxetKBcuVZtMYjcz45mxne8DeIJJvBQy9l2dedqVmbCu8bh1Y6u5CDyeZRnNQ47G6mQq386C2Q50HJvtA6y2lnbEJzUt82c_v61eosO_oIoTS_bnFRbwGNeJu3YPA1RIDA4j2S8mcIFlWAMqtCm-DxeFoPyaXk5Zi0o1eP-2jPPvjZOXlsW5Wf0web4WlYZX4UqbTrLDRv_XYMcW1-HyGsjgDfj1AY2ZXpBi77FknZcVe0PYlTV-MQowGhHwRL3azmgjXvndstGfqUOGaS2ryZcTEq-3jHYjJmuGBGqInRWs403IV9jGF7w-ZRgLl18NmzTwrdVNOB0en746cVsOBjfBRGlBTLdeJuIgNDpMReaHmeCUIkiNnm-0iq2Hv8Iw9g3XRmX8wAvxi28CafwgFrdgt5gX9g4wzRMtUqviOLSSZ8rEyhBjkZd6KYHoOfC0U0GUtPjkRJORR1inkOKiXnEOPOpFzxtQjm1CR6THXoBwtOsD8_JT1LplFFg_wd4ry3FcCrFv1pfWF6lKUiwFpXXgYWcFEfodLaaYws6XVcSl8jStWikHbjdW0TfVWZUDesNeNvqyeaY4-1xje2uF-aH2HHjcW9a__-Ld_77_PdjnNHFQ72e8D7uLcmkfYHa1iAdwQc80fh4MXw9g7-h4PHk3qGcqBrVX4bHpeHL48TfFli0T
linkProvider Scholars Portal
linkToUnpaywall http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Zb9QwELbQ9gF44D7CJXM88JKur9ibJ1QQVUFqVYlWlKfITmxYWLKrPYrKb-BHM-Mc7EKRkJDykGMS28p4_I09_oaQZwDilVSOpyYwk6ogfWqZ8KnzRsiMiRACzkPuH-i9Y_X2JDtZ28WPYZXgio-jkcZdWCmMYGyIhxhqsLjDWRVenLZzSRzAONf5SIPTvqUzQOMDsnV8cLjzIW4qat9uCIUkePfDBfj6Aj-zMQxFtv7zIOafkZIXV_XMnn2zk8naMLR7ldiuAU30yZft1dJtl99_43b8nxZeI1dajEp3GqW6Ti74-ga5vMZceJP8eA89BHdd0XfgB0_nC_oGCTEjKTIIUDQz8CAu4VOM7puferr_az6SAlamMaNzieIxDrUzw7SxM1gQHde0S8YwOYMyPsP7FYUBdvXV0sOGE3Zxixztvj56tZe2iR3SEtDXEtPnsiBdlluTVzLwPEiBuEMZMCfWaOcZXOW541YYq4MYsRxOuM2U5ZmTt8mgntb-LqFGlEZWXjuXeyWCtk5bTIPEKlYhM19Cnne_uShb0nPMvTEpwPlBjSh6jUjIk1501jB9nCf0EnWlF0By7nhjOv9YtH29yDwvofbaCzB2OdTNc-W5rHRZgX-pfEIed5pWQGfGFRpb--lqUQilmcGlMJ2QO43m9UVJia6gHCXEbOjkRl02n9TjT5Ew3GgAnYYl5GmvvX9v4r1_krpPLgmceYgBkQ_IYDlf-YcAz5buUdsDfwL3ajZN
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Wearable+Sensors+Incorporating+Compensatory+Reserve+Measurement+for+Advancing+Physiological+Monitoring+in+Critically+Injured+Trauma+Patients&rft.jtitle=Sensors+%28Basel%2C+Switzerland%29&rft.au=Convertino%2C+Victor+A.&rft.au=Schauer%2C+Steven+G.&rft.au=Weitzel%2C+Erik+K.&rft.au=Cardin%2C+Sylvain&rft.date=2020-11-10&rft.pub=MDPI&rft.eissn=1424-8220&rft.volume=20&rft.issue=22&rft_id=info:doi/10.3390%2Fs20226413&rft_id=info%3Apmid%2F33182638&rft.externalDocID=PMC7697670
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1424-8220&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1424-8220&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1424-8220&client=summon