Reconstruction of knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model

Purpose: Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed tomography (CT) and magnetic resonance imaging (MRI) are used to obtain the patient anatomy as they are accurate imaging modalities. However,...

Full description

Saved in:
Bibliographic Details
Published inJournal of medical imaging (Bellingham, Wash.) Vol. 8; no. 1; p. 016001
Main Authors Wu, Jing, Mahfouz, Mohamed R
Format Journal Article
LanguageEnglish
Published United States Society of Photo-Optical Instrumentation Engineers 01.01.2021
Subjects
Online AccessGet full text
ISSN2329-4302
2329-4310
2329-4310
DOI10.1117/1.JMI.8.1.016001

Cover

Abstract Purpose: Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed tomography (CT) and magnetic resonance imaging (MRI) are used to obtain the patient anatomy as they are accurate imaging modalities. However, computing anatomical landmarks from the patient anatomy for PSIs requires either high-resolution CT, increasing time of scan and radiation exposure to the patient, or longer and more expensive MRI scans. As an alternative, reconstruction from single-plane fluoroscopic x-ray provides a cost-efficient tool to obtain patient anatomical structures while allowing capture of the patient’s joint dynamics, important clinical information for TJR. Approach: We present a three-dimensional (3D) reconstruction scheme that automatically and accurately reconstructs the 3D knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model called kernel principal component analysis. To increase robustness, we designed a hybrid energy function that integrated feature and intensity information as a similarity measure for the 3D reconstruction. Results: We evaluated the proposed method on five subjects during deep knee bending: the root-mean-square accuracy is 1.19  ±  0.36  mm for reconstructed femur and 1.15  ±  0.17  mm for reconstructed tibia. Conclusions: The proposed method demonstrates reliable 3D bone model reconstruction accuracy with successful elimination of prior 3D imaging and reduction of manual labor and radiation dose on patient as well as characterizing joints in motion. This method is promising for applications in medical interventions such as patient-specific arthroplasty design, surgical planning, surgical navigation, and understanding anatomical and dynamic characteristics of joints.
AbstractList Purpose: Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed tomography (CT) and magnetic resonance imaging (MRI) are used to obtain the patient anatomy as they are accurate imaging modalities. However, computing anatomical landmarks from the patient anatomy for PSIs requires either high-resolution CT, increasing time of scan and radiation exposure to the patient, or longer and more expensive MRI scans. As an alternative, reconstruction from single-plane fluoroscopic x-ray provides a cost-efficient tool to obtain patient anatomical structures while allowing capture of the patient's joint dynamics, important clinical information for TJR. Approach: We present a three-dimensional (3D) reconstruction scheme that automatically and accurately reconstructs the 3D knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model called kernel principal component analysis. To increase robustness, we designed a hybrid energy function that integrated feature and intensity information as a similarity measure for the 3D reconstruction. Results: We evaluated the proposed method on five subjects during deep knee bending: the root-mean-square accuracy is 1.19 ± 0.36    mm for reconstructed femur and 1.15 ± 0.17    mm for reconstructed tibia. Conclusions: The proposed method demonstrates reliable 3D bone model reconstruction accuracy with successful elimination of prior 3D imaging and reduction of manual labor and radiation dose on patient as well as characterizing joints in motion. This method is promising for applications in medical interventions such as patient-specific arthroplasty design, surgical planning, surgical navigation, and understanding anatomical and dynamic characteristics of joints.Purpose: Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed tomography (CT) and magnetic resonance imaging (MRI) are used to obtain the patient anatomy as they are accurate imaging modalities. However, computing anatomical landmarks from the patient anatomy for PSIs requires either high-resolution CT, increasing time of scan and radiation exposure to the patient, or longer and more expensive MRI scans. As an alternative, reconstruction from single-plane fluoroscopic x-ray provides a cost-efficient tool to obtain patient anatomical structures while allowing capture of the patient's joint dynamics, important clinical information for TJR. Approach: We present a three-dimensional (3D) reconstruction scheme that automatically and accurately reconstructs the 3D knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model called kernel principal component analysis. To increase robustness, we designed a hybrid energy function that integrated feature and intensity information as a similarity measure for the 3D reconstruction. Results: We evaluated the proposed method on five subjects during deep knee bending: the root-mean-square accuracy is 1.19 ± 0.36    mm for reconstructed femur and 1.15 ± 0.17    mm for reconstructed tibia. Conclusions: The proposed method demonstrates reliable 3D bone model reconstruction accuracy with successful elimination of prior 3D imaging and reduction of manual labor and radiation dose on patient as well as characterizing joints in motion. This method is promising for applications in medical interventions such as patient-specific arthroplasty design, surgical planning, surgical navigation, and understanding anatomical and dynamic characteristics of joints.
Purpose: Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed tomography (CT) and magnetic resonance imaging (MRI) are used to obtain the patient anatomy as they are accurate imaging modalities. However, computing anatomical landmarks from the patient anatomy for PSIs requires either high-resolution CT, increasing time of scan and radiation exposure to the patient, or longer and more expensive MRI scans. As an alternative, reconstruction from single-plane fluoroscopic x-ray provides a cost-efficient tool to obtain patient anatomical structures while allowing capture of the patient’s joint dynamics, important clinical information for TJR. Approach: We present a three-dimensional (3D) reconstruction scheme that automatically and accurately reconstructs the 3D knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model called kernel principal component analysis. To increase robustness, we designed a hybrid energy function that integrated feature and intensity information as a similarity measure for the 3D reconstruction. Results: We evaluated the proposed method on five subjects during deep knee bending: the root-mean-square accuracy is 1.19±0.36  mm for reconstructed femur and 1.15±0.17  mm for reconstructed tibia. Conclusions: The proposed method demonstrates reliable 3D bone model reconstruction accuracy with successful elimination of prior 3D imaging and reduction of manual labor and radiation dose on patient as well as characterizing joints in motion. This method is promising for applications in medical interventions such as patient-specific arthroplasty design, surgical planning, surgical navigation, and understanding anatomical and dynamic characteristics of joints.
Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed tomography (CT) and magnetic resonance imaging (MRI) are used to obtain the patient anatomy as they are accurate imaging modalities. However, computing anatomical landmarks from the patient anatomy for PSIs requires either high-resolution CT, increasing time of scan and radiation exposure to the patient, or longer and more expensive MRI scans. As an alternative, reconstruction from single-plane fluoroscopic x-ray provides a cost-efficient tool to obtain patient anatomical structures while allowing capture of the patient's joint dynamics, important clinical information for TJR. We present a three-dimensional (3D) reconstruction scheme that automatically and accurately reconstructs the 3D knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model called kernel principal component analysis. To increase robustness, we designed a hybrid energy function that integrated feature and intensity information as a similarity measure for the 3D reconstruction. We evaluated the proposed method on five subjects during deep knee bending: the root-mean-square accuracy is for reconstructed femur and for reconstructed tibia. The proposed method demonstrates reliable 3D bone model reconstruction accuracy with successful elimination of prior 3D imaging and reduction of manual labor and radiation dose on patient as well as characterizing joints in motion. This method is promising for applications in medical interventions such as patient-specific arthroplasty design, surgical planning, surgical navigation, and understanding anatomical and dynamic characteristics of joints.
Purpose: Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed tomography (CT) and magnetic resonance imaging (MRI) are used to obtain the patient anatomy as they are accurate imaging modalities. However, computing anatomical landmarks from the patient anatomy for PSIs requires either high-resolution CT, increasing time of scan and radiation exposure to the patient, or longer and more expensive MRI scans. As an alternative, reconstruction from single-plane fluoroscopic x-ray provides a cost-efficient tool to obtain patient anatomical structures while allowing capture of the patient’s joint dynamics, important clinical information for TJR. Approach: We present a three-dimensional (3D) reconstruction scheme that automatically and accurately reconstructs the 3D knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model called kernel principal component analysis. To increase robustness, we designed a hybrid energy function that integrated feature and intensity information as a similarity measure for the 3D reconstruction. Results: We evaluated the proposed method on five subjects during deep knee bending: the root-mean-square accuracy is 1.19  ±  0.36  mm for reconstructed femur and 1.15  ±  0.17  mm for reconstructed tibia. Conclusions: The proposed method demonstrates reliable 3D bone model reconstruction accuracy with successful elimination of prior 3D imaging and reduction of manual labor and radiation dose on patient as well as characterizing joints in motion. This method is promising for applications in medical interventions such as patient-specific arthroplasty design, surgical planning, surgical navigation, and understanding anatomical and dynamic characteristics of joints.
Author Wu, Jing
Mahfouz, Mohamed R
Author_xml – sequence: 1
  givenname: Jing
  surname: Wu
  fullname: Wu, Jing
  email: wujing065@gmail.com
  organization: University of Tennessee, Department of Mechanical, Aerospace, and Biomedical Engineering, Knoxville, Tennessee, United States
– sequence: 2
  givenname: Mohamed R
  surname: Mahfouz
  fullname: Mahfouz, Mohamed R
  email: mmahfouz@utk.edu
  organization: University of Tennessee, Department of Mechanical, Aerospace, and Biomedical Engineering, Knoxville, Tennessee, United States
BackLink https://www.ncbi.nlm.nih.gov/pubmed/33457444$$D View this record in MEDLINE/PubMed
BookMark eNp1ks1v1DAQxS1UREvpnRPykUuCHXvjzQUJVUCLipAQnK2JP1ovjh3sBNj_vg4ppaXiNJb8fvM8b_wUHYQYDELPKakppeIVrT98PK-3Na0JbQmhj9BRw5qu4oySg9szaQ7RSc47UhSUbBrKn6BDxvhGcM6P0PjZqBjylGY1uRhwtPhbMAZDgCkOe2xTHHB24dKbavQQDLZ-jilmFUen8K8qwR73kI3GhQZc3uhdMJBwnmByeXIKPM5XMBo8RG38M_TYgs_m5KYeo6_v3n45PasuPr0_P31zUSnO-FT1VG_6pmtZxzsmWs20aS2l2w3VHKAxRAulOekJgYZbUFbRxhLSamsoZ0ywY0TXvnMYYf8TvJdjcgOkvaRELgFKKneDk9tS1wAL83plxrkfjFYmTAn-chGcvH8T3JW8jD-kEJ0Q28X05U2DFL_PJk9ycFkZvwQX5ywbXlSC8d9eL-563Zr8WU0RtKtAlbRzMlYqt0QaF2vn70xRvsH9Kcg_4MPBHyDViuTRGbmLcwplN__XXwPMGMO-
CitedBy_id crossref_primary_10_1186_s42492_023_00142_7
crossref_primary_10_1109_TMI_2022_3218568
crossref_primary_10_1016_j_clinbiomech_2023_106091
crossref_primary_10_1088_1361_6560_ac508d
ContentType Journal Article
Copyright The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
2021 The Authors.
2021 The Authors 2021 The Authors
Copyright_xml – notice: The Authors. Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
– notice: 2021 The Authors.
– notice: 2021 The Authors 2021 The Authors
DBID AAYXX
CITATION
NPM
7X8
5PM
ADTOC
UNPAY
DOI 10.1117/1.JMI.8.1.016001
DatabaseName CrossRef
PubMed
MEDLINE - Academic
PubMed Central (Full Participant titles)
Unpaywall for CDI: Periodical Content
Unpaywall
DatabaseTitle CrossRef
PubMed
MEDLINE - Academic
DatabaseTitleList MEDLINE - Academic

PubMed

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: UNPAY
  name: Unpaywall
  url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/
  sourceTypes: Open Access Repository
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2329-4310
EndPage 016001
ExternalDocumentID 10.1117/1.jmi.8.1.016001
PMC7797787
33457444
10_1117_1_JMI_8_1_016001
Genre Journal Article
GroupedDBID 0R
ACGFS
ALMA_UNASSIGNED_HOLDINGS
EBS
FQ0
M4X
O9-
RPM
SPBNH
UT2
0R~
4.4
AAYXX
ABJNI
ADMLS
AKROS
CITATION
HYE
OK1
EJD
NPM
7X8
5PM
ADTOC
IAO
UNPAY
ID FETCH-LOGICAL-c434t-b1d5b2963949376d3de6f11851d4aa2e0d7cd40b00a24facfc12f006dfe143373
IEDL.DBID UNPAY
ISSN 2329-4302
2329-4310
IngestDate Sun Oct 26 03:37:29 EDT 2025
Tue Sep 30 16:33:06 EDT 2025
Fri Jul 11 13:32:39 EDT 2025
Wed Feb 19 02:26:36 EST 2025
Thu Apr 24 23:11:45 EDT 2025
Tue Jul 01 02:15:58 EDT 2025
Tue Mar 02 04:32:30 EST 2021
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 1
Keywords 2D–3D non-rigid registration
statistical shape model
3D shape reconstruction
kernel principal component analysis
total joint replacement
fluoroscopic x-ray
Language English
License 2021 The Authors.
Published by SPIE under a Creative Commons Attribution 4.0 Unported License. Distribution or reproduction of this work in whole or in part requires full attribution of the original publication, including its DOI.
cc-by
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c434t-b1d5b2963949376d3de6f11851d4aa2e0d7cd40b00a24facfc12f006dfe143373
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
OpenAccessLink https://proxy.k.utb.cz/login?url=https://www.spiedigitallibrary.org/journals/journal-of-medical-imaging/volume-8/issue-1/016001/Reconstruction-of-knee-anatomy-from-single-plane-fluoroscopic-x-ray/10.1117/1.JMI.8.1.016001.pdf
PMID 33457444
PQID 2478773401
PQPubID 23479
PageCount 1
ParticipantIDs pubmed_primary_33457444
pubmedcentral_primary_oai_pubmedcentral_nih_gov_7797787
unpaywall_primary_10_1117_1_jmi_8_1_016001
crossref_citationtrail_10_1117_1_JMI_8_1_016001
crossref_primary_10_1117_1_JMI_8_1_016001
proquest_miscellaneous_2478773401
spie_journals_10_1117_1_JMI_8_1_016001
ProviderPackageCode FQ0
SPBNH
UT2
CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2021-01-01
PublicationDateYYYYMMDD 2021-01-01
PublicationDate_xml – month: 01
  year: 2021
  text: 2021-01-01
  day: 01
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
PublicationTitle Journal of medical imaging (Bellingham, Wash.)
PublicationTitleAlternate J. Med. Imag
PublicationYear 2021
Publisher Society of Photo-Optical Instrumentation Engineers
Publisher_xml – name: Society of Photo-Optical Instrumentation Engineers
SSID ssj0001105214
Score 2.2160795
Snippet Purpose: Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed...
Reconstruction of patient anatomy is critical to patient-specific instrument (PSI) design in total joint replacement (TJR). Conventionally, computed tomography...
SourceID unpaywall
pubmedcentral
proquest
pubmed
crossref
spie
SourceType Open Access Repository
Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 016001
SubjectTerms Biomedical Applications in Molecular, Structural, and Functional Imaging
Title Reconstruction of knee anatomy from single-plane fluoroscopic x-ray based on a nonlinear statistical shape model
URI http://www.dx.doi.org/10.1117/1.JMI.8.1.016001
https://www.ncbi.nlm.nih.gov/pubmed/33457444
https://www.proquest.com/docview/2478773401
https://pubmed.ncbi.nlm.nih.gov/PMC7797787
https://www.spiedigitallibrary.org/journals/journal-of-medical-imaging/volume-8/issue-1/016001/Reconstruction-of-knee-anatomy-from-single-plane-fluoroscopic-x-ray/10.1117/1.JMI.8.1.016001.pdf
UnpaywallVersion publishedVersion
Volume 8
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVEBS
  databaseName: Inspec with Full Text
  customDbUrl:
  eissn: 2329-4310
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0001105214
  issn: 2329-4310
  databaseCode: ADMLS
  dateStart: 20140701
  isFulltext: true
  titleUrlDefault: https://www.ebsco.com/products/research-databases/inspec-full-text
  providerName: EBSCOhost
– providerCode: PRVAQN
  databaseName: PubMed Central
  customDbUrl:
  eissn: 2329-4310
  dateEnd: 20241102
  omitProxy: true
  ssIdentifier: ssj0001105214
  issn: 2329-4310
  databaseCode: RPM
  dateStart: 20140101
  isFulltext: true
  titleUrlDefault: https://www.ncbi.nlm.nih.gov/pmc/
  providerName: National Library of Medicine
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMw1V1Lb9QwELbKVuJx4E27PCojISSQnGxsJ9kcK0RVKm3FgZXKKXJiu126m432IVj-HH-Fn8KM8yBLUSWOnBIpY2cymrFn4plvCHkl0OvQhjMzMJJJnWg2THLOBOwFYWaNyVwd9-g0Oh7Lk7PwbIf8aGphMK1yWYL3NTnHphkt7sPi3K-Fu2xu2NyyWXWawSYz19PHr0yaDX3HNQt8BFAbBK5s4TciK468LIxhqoDIdrZhWMrBMDafGlZikimz0_Uc4STn5SRn39hCber1JfYD72T0wRt6gVdN7pXa3iC7UQjBQI_sjk8_Hn52Le14wqRwWY_1fTBoDkrdNF9mk8402xvjFW_3atJmD-V0h9xaF6XafAVZdTbGo3vkZyPSKh_m0luvMi___gfa5H8s8_vkbu2008PKyh6QHVM8JDdHdVrCI1JuM0HnliITtGaCIhO0ywTtMkEdExT9CU1htKJFhV-iFhTrvRyUNrx-eaFKQ13rosdkfPT-07tjVreyYLkUcsWyQIcZh8UukeAPRlpoE1mI7cJAS6W4Geg413IAa6Di0qrc5gG3sCBqa8ChFbF4QnrwbrNPqMwSxRMYoLmQNkwyKS3XIos4QidFuk_8Ro_SvMZ5x3Yj07SK9-I0SEGY6RCulTD75E07oqwwTq6hfdmoZgoLEZ4ugdTm62XKEeYpFhJp9ipVbWcTQoaxlLJP4i0lbgkQ5Hz7STG5cGDncQwRyjDuk9eoommjkNcw-LY1iL98Ddhch_jpvxA_I7c5JjS5_2_PSQ-UyrwAj3SVHbifhAe17f8CY2aQnA
linkProvider Unpaywall
linkToUnpaywall http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMw1V1LbxMxELZKKgE98Cw0vGQkhASSd7O293WsEFWplIoDkcpp5V3bbWiyWeUhCH-Ov8JPYcb7IKGoEkdOWSlj72Q0M56JZ74h5JXAqEMbzszASCZ1qlmSFpwJOAvC3BqTuz7u4Wl0PJInZ-HZDvnR9sJgWeWiguhrfI5DMzrch_m53wh30T6wmWXT-jaDjadupo9fmzRLfMc1C3wEUBsErm3hNyIrrrwsjWGqhMx2umbYysEwN58YVmGRKbOT1QzhJGfVuGDf2FytG_8S-4F3MvzgJV7g1Zt7lbY3yG4UQjLQI7uj04-Hn91IO54yKVzVY_McDNqLUrfNl-l4Y5vtg_FKtHu1aLOHctojt1ZlpdZfQVYbB-PRXfKzFWldD3PprZa5V3z_A23yP5b5PXKnCdrpYW1l98mOKR-Qm8OmLOEhqbaZoDNLkQnaMEGRCbrJBN1kgjomKMYTmsJqRcsav0TNKfZ7OShteP3iQlWGutFF-2R09P7Tu2PWjLJghRRyyfJAhzkHZ5dKiAcjLbSJLOR2YaClUtwMdFxoOQAfqLi0qrBFwC04RG0NBLQiFo9ID95tDgiVeap4Cgs0F9KGaS6l5VrkEUfopEj3id_qUVY0OO84bmSS1flenAUZCDNL4LMWZp-86VZUNcbJNbQvW9XMwBHh7RJIbbZaZBxhnmIhkeZxrardbkLIMJZS9km8pcQdAYKcb39Tji8c2HkcQ4aSxH3yGlU0axXyGgbfdgbxl18DNrdB_ORfiJ-S2xwLmtz_b89ID5TKPIeIdJm_aKz-FwTuj4w
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Reconstruction+of+knee+anatomy+from+single-plane+fluoroscopic+x-ray+based+on+a+nonlinear+statistical+shape+model&rft.jtitle=Journal+of+medical+imaging+%28Bellingham%2C+Wash.%29&rft.au=Wu%2C+Jing&rft.au=Mahfouz%2C+Mohamed+R&rft.date=2021-01-01&rft.issn=2329-4302&rft.volume=8&rft.issue=1&rft.spage=016001&rft_id=info:doi/10.1117%2F1.JMI.8.1.016001&rft.externalDBID=NO_FULL_TEXT
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2329-4302&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2329-4302&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2329-4302&client=summon