High-resolution local field potentials measured with deep brain stimulation arrays

Objective. Local field potential (LFP) recordings along a deep brain stimulation (DBS) lead can provide useful feedback for titrating DBS therapy. However, conventional DBS leads with four cylindrical macroelectrodes likely undersample the spatial distribution of sinks and sources in a given brain r...

Full description

Saved in:
Bibliographic Details
Published inJournal of neural engineering Vol. 15; no. 4; pp. 46019 - 46031
Main Authors Zhang, Simeng, Connolly, Allison T, Madden, Lauren R, Vitek, Jerrold L, Johnson, Matthew D
Format Journal Article
LanguageEnglish
Published England IOP Publishing 01.08.2018
Subjects
Online AccessGet full text
ISSN1741-2560
1741-2552
1741-2552
DOI10.1088/1741-2552/aabdf5

Cover

More Information
Summary:Objective. Local field potential (LFP) recordings along a deep brain stimulation (DBS) lead can provide useful feedback for titrating DBS therapy. However, conventional DBS leads with four cylindrical macroelectrodes likely undersample the spatial distribution of sinks and sources in a given brain region. In this study, we investigated the spectral power and spatial feature sizes of LFP activity in non-human primate subthalamic nucleus and globus pallidus using chronically implanted 32-channel directional DBS arrays. Approach. Subthalamic nucleus and globus pallidus LFP signals were recorded from directional DBS arrays in the resting state and during a reach-and-retrieval task in two non-human primates in naïve and parkinsonian conditions. LFP recordings were compared amongst bipolar pairs of electrodes using individual and grouped electrode configurations, with the latter mimicking the cylindrical macroelectrode configurations used in current clinical LFP recordings. Main results. Recordings from these DBS arrays showed that (1) beta oscillations have spatial 'fingerprints' in the subthalamic nucleus and globus pallidus, and (2) that these oscillations were muted when grouping electrode contacts together to create cylindrical macroelectrodes similar in relative dimension to those used clinically. Further, these maps depended on parkinsonian condition and whether the subject was resting or performing a motor task. Significance. Development of future closed-loop DBS therapies that rely on LFP feedback will benefit from implanting DBS arrays with electrode sizes and spacings that are more consistent with the dimensions of oscillatory sinks and sources within the brain.
Bibliography:JNE-102156.R1
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Authors contributed equally to the work
ISSN:1741-2560
1741-2552
1741-2552
DOI:10.1088/1741-2552/aabdf5