Machine learning algorithm for ventilator mode selection, pressure and volume control

Mechanical ventilation techniques are vital for preserving individuals with a serious condition lives in the prolonged hospitalization unit. Nevertheless, an imbalance amid the hospitalized people demands and the respiratory structure could cause to inconsistencies in the patient’s inhalation. To ta...

Full description

Saved in:
Bibliographic Details
Published inPloS one Vol. 19; no. 3; p. e0299653
Main Authors T., Anitha, G., Gopu, P., Arun Mozhi Devan, Assaad, Maher
Format Journal Article
LanguageEnglish
Published United States Public Library of Science 13.03.2024
Subjects
Online AccessGet full text
ISSN1932-6203
1932-6203
DOI10.1371/journal.pone.0299653

Cover

More Information
Summary:Mechanical ventilation techniques are vital for preserving individuals with a serious condition lives in the prolonged hospitalization unit. Nevertheless, an imbalance amid the hospitalized people demands and the respiratory structure could cause to inconsistencies in the patient’s inhalation. To tackle this problem, this study presents an Iterative Learning PID Controller (ILC-PID), a unique current cycle feedback type controller that helps in gaining the correct pressure and volume. The paper also offers a clear and complete examination of the primarily efficient neural approach for generating optimal inhalation strategies. Moreover, machine learning-based classifiers are used to evaluate the precision and performance of the ILC-PID controller. These classifiers able to forecast and choose the perfect type for various inhalation modes, eliminating the likelihood that patients will require mechanical ventilation. In pressure control, the suggested accurate neural categorization exhibited an average accuracy rate of 88.2% in continuous positive airway pressure (CPAP) mode and 91.7% in proportional assist ventilation (PAV) mode while comparing with the other classifiers like ensemble classifier has reduced accuracy rate of 69.5% in CPAP mode and also 71.7% in PAV mode. An average accuracy of 78.9% rate in other classifiers compared to neutral network in CPAP. The neural model had an typical range of 81.6% in CPAP mode and 84.59% in PAV mode for 20 cm H 2 O of volume created by the neural network classifier in the volume investigation. Compared to the other classifiers, an average of 72.17% was in CPAP mode, and 77.83% was in PAV mode in volume control. Different approaches, such as decision trees, optimizable Bayes trees, naive Bayes trees, nearest neighbour trees, and an ensemble of trees, were also evaluated regarding the accuracy by confusion matrix concept, training duration, specificity, sensitivity, and F1 score.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
Competing Interests: The authors have declared that no competing interests exist.
ISSN:1932-6203
1932-6203
DOI:10.1371/journal.pone.0299653