Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity
Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to esta...
Saved in:
Published in | Acta ophthalmologica (Oxford, England) Vol. 93; no. 2; pp. 154 - 161 |
---|---|
Main Authors | , , , |
Format | Journal Article |
Language | English |
Published |
England
Wiley Subscription Services, Inc
01.03.2015
|
Subjects | |
Online Access | Get full text |
ISSN | 1755-375X 1755-3768 1755-3768 |
DOI | 10.1111/aos.12487 |
Cover
Abstract | Purpose
This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods.
Methods
Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18–25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV‐1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland–Altman technique was used to analyse the agreement between ICS obtained by the different test methods.
Results
A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was −0.15 (95% percentile 0.45), compared with −0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV‐1000E. The mean difference between ICSFACT85 and ICSCSV was −0.43 (95% CI −0.56 to −0.30, p < 0.00) with limits of agreement (LoA) within −2.10 and 1.22. The regression line on the difference of average was near to zero (R2 = 0.03).
Conclusion
The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes. |
---|---|
AbstractList | This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods.
Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods.
A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03).
The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes. Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Methods Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18–25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV‐1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland–Altman technique was used to analyse the agreement between ICS obtained by the different test methods. Results A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was −0.15 (95% percentile 0.45), compared with −0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV‐1000E. The mean difference between ICSFACT85 and ICSCSV was −0.43 (95% CI −0.56 to −0.30, p < 0.00) with limits of agreement (LoA) within −2.10 and 1.22. The regression line on the difference of average was near to zero (R2 = 0.03). Conclusion The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes. This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods.PURPOSEThis study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods.Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods.METHODSMilitary recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods.A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03).RESULTSA total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03).The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.CONCLUSIONThe results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes. Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Methods Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. Results A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p < 0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2 = 0.03). Conclusion The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes. |
Author | Baste, Valborg Høvding, Gunnar Roumes, Corinne Koefoed, Vilhelm F. |
Author_xml | – sequence: 1 givenname: Vilhelm F. orcidid: 0000-0001-7844-4881 surname: Koefoed fullname: Koefoed, Vilhelm F. organization: University of Bergen – sequence: 2 givenname: Valborg surname: Baste fullname: Baste, Valborg organization: University of Bergen – sequence: 3 givenname: Corinne surname: Roumes fullname: Roumes, Corinne organization: Institut de Recherche Biomédicale des Armées – sequence: 4 givenname: Gunnar surname: Høvding fullname: Høvding, Gunnar organization: University of Bergen |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/25056525$$D View this record in MEDLINE/PubMed |
BookMark | eNp90U1r3DAQBmBRUrrJtof-gSDoJYFuItv6sI9hSdJCIIek0JuRrVFWiy2l-sjifx9tdpvDQqvL6PDMMMx7go6ss4DQ14JcFPldShcuipLW4gM6LgRji0rw-uj9z37P0EkIa0J4wTn9hGYlI4yzkh0ju3Q2ehkiDmCDiebFxAmPIEPyoHA34bhxWBmtwYONOEKmI8SVUwEbi1cgh7iavuPJJfuEpUpDDHhj4gpb50c54BcTUi6yT3nyZ_RRyyHAl32do18314_LH4u7-9ufy6u7RU_LSixqDaKuCJVKqErIThBWaNJ1De2Z5I2mGkpeA5eK8qakoOqKU626hhFCaEmrOTrbzX327k_KO7ejCT0Mg7TgUmgLzkRVUtbwTL8d0LVL3ubttopRxishsjrdq9SNoNpnb0bpp_bvJTM434HeuxA86HdSkHabUptTat9SyvbywPYmymjeojDD_zo2ZoDp36Pbq_uHXccrrqSj2g |
CitedBy_id | crossref_primary_10_1038_s41598_024_52836_4 crossref_primary_10_1111_opo_13037 crossref_primary_10_1177_14771535211049816 crossref_primary_10_1186_s12886_022_02621_6 crossref_primary_10_1002_1348_9585_12279 crossref_primary_10_3928_1081597X_20240723_04 crossref_primary_10_1016_j_ajo_2019_07_001 crossref_primary_10_3758_s13414_016_1219_z crossref_primary_10_1038_srep46706 crossref_primary_10_1093_milmed_usab071 crossref_primary_10_3341_jkos_2021_62_5_638 crossref_primary_10_1186_s12886_020_01549_z crossref_primary_10_3389_fpsyg_2021_772661 crossref_primary_10_1097_ICL_0000000000000371 crossref_primary_10_4103_joco_joco_147_21 crossref_primary_10_3389_fpsyg_2018_00899 crossref_primary_10_3390_diagnostics14131377 crossref_primary_10_3390_technologies12070108 crossref_primary_10_1038_s41598_022_17448_w crossref_primary_10_1111_aos_13673 |
Cites_doi | 10.1111/j.1475-1313.1992.tb00397.x 10.1136/bjo.88.1.11 10.1371/journal.pone.0040239 10.1097/OPX.0b013e318264097b 10.1016/j.visres.2010.05.021 10.1016/S0042-6989(02)00038-X 10.1097/01.opx.0000216100.93302.2d 10.1177/001872088502700602 10.1111/j.1475-1313.2010.00815.x 10.1097/00006324-199503000-00006 10.1177/096228029900800204 10.1016/j.ajo.2008.09.032 10.1007/s00417-007-0662-x 10.3928/1081-597X-19980701-14 10.1016/S0039-6257(02)00350-8 10.1111/j.1475-1313.2011.00851.x 10.1080/13882350802632401 10.1016/j.jcrs.2009.10.048 10.1097/00006324-198201000-00020 10.1016/0042-6989(83)90210-9 10.1111/j.1755-3768.2011.02379.x 10.1097/00004397-200343020-00004 10.1016/j.neuro.2010.06.004 10.1097/00004397-200343020-00006 10.1111/j.1755-3768.2011.02323.x |
ContentType | Journal Article |
Copyright | 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd. Copyright © 2015 Acta Ophthalmologica Scandinavica Foundation |
Copyright_xml | – notice: 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd – notice: 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd. – notice: Copyright © 2015 Acta Ophthalmologica Scandinavica Foundation |
DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 7TK 7X8 |
DOI | 10.1111/aos.12487 |
DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed Neurosciences Abstracts MEDLINE - Academic |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) Neurosciences Abstracts MEDLINE - Academic |
DatabaseTitleList | MEDLINE MEDLINE - Academic Neurosciences Abstracts |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1755-3768 |
EndPage | 161 |
ExternalDocumentID | 3592872901 25056525 10_1111_aos_12487 AOS12487 |
Genre | article Research Support, Non-U.S. Gov't Journal Article |
GrantInformation_xml | – fundername: Norwegian Centre of Maritime Medicine – fundername: Royal Norwegian Navy |
GroupedDBID | --- .3N .55 .GA .Y3 05W 0R~ 10A 1OC 23M 24P 31~ 33P 36B 3SF 4.4 50Y 50Z 51W 51X 52M 52N 52O 52P 52R 52S 52T 52U 52V 52W 52X 53G 5GY 5HH 5LA 5VS 66C 702 7PT 8-0 8-1 8-3 8-4 8-5 8UM 930 A01 A03 AAESR AAEVG AAHHS AAHQN AAIPD AAMNL AANLZ AAONW AASGY AAXRX AAYCA AAZKR ABCUV ABDBF ABEML ABJNI ABPVW ABQWH ABXGK ACAHQ ACCFJ ACCZN ACGFS ACGOF ACMXC ACNCT ACPOU ACPRK ACSCC ACUHS ACXBN ACXQS ADBBV ADBTR ADEOM ADIZJ ADKYN ADMGS ADOZA ADXAS ADZMN ADZOD AEEZP AEIGN AEIMD AENEX AEQDE AEUQT AEUYR AFBPY AFFPM AFGKR AFPWT AFRAH AFWVQ AFZJQ AHBTC AHMBA AIACR AITYG AIURR AIWBW AJBDE ALAGY ALMA_UNASSIGNED_HOLDINGS ALUQN ALVPJ AMBMR AMYDB ASPBG ATUGU AVWKF AZBYB AZFZN AZVAB BAFTC BAWUL BFHJK BHBCM BMXJE BROTX BRXPI BY8 C45 CAG COF CS3 D-6 D-7 D-E D-F DCZOG DIK DPXWK DR2 DRFUL DRMAN DRSTM E3Z EAD EAP EBC EBD EBS EJD EMB EMK EMOBN ESX EX3 F00 F01 F04 F5P FIJ FUBAC G-S GODZA H.X HF~ HGLYW HZI HZ~ IPNFZ IX1 J0M K48 KBYEO LATKE LC2 LC3 LEEKS LH4 LITHE LOXES LP6 LP7 LUTES LW6 LYRES MEWTI MK4 MRFUL MRMAN MRSTM MSFUL MSMAN MSSTM MXFUL MXMAN MXSTM N04 N05 N9A NF~ O66 O9- OIG OK1 OVD P2W P2X P2Z P4B P4D P6G PQQKQ Q.N Q11 QB0 R.K RIWAO RJQFR ROL RX1 SUPJJ SV3 TEORI TR2 TUS UB1 V9Y W8V W99 WBKPD WHWMO WIH WIJ WIK WIN WOHZO WOW WQJ WRC WVDHM WXI WXSBR X7M XG1 ~IA ~WT AAYXX AEYWJ AGHNM AGYGG CITATION AAMMB AEFGJ AGXDD AIDQK AIDYY CGR CUY CVF ECM EIF NPM 1OB 7TK 7X8 |
ID | FETCH-LOGICAL-c4237-8fe78304ad7d37ab7051f0bb94c5a69f4fe268e6ad46924ed8364fdb950004243 |
IEDL.DBID | DR2 |
ISSN | 1755-375X 1755-3768 |
IngestDate | Thu Sep 04 21:02:23 EDT 2025 Wed Aug 13 07:04:45 EDT 2025 Mon Jul 21 05:49:31 EDT 2025 Tue Jul 01 00:24:39 EDT 2025 Thu Apr 24 23:06:20 EDT 2025 Wed Jan 22 16:55:35 EST 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 2 |
Keywords | photopic vision visual quality mesopic vision contrast sensitivity medical selection visual function |
Language | English |
License | 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd. |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c4237-8fe78304ad7d37ab7051f0bb94c5a69f4fe268e6ad46924ed8364fdb950004243 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 content type line 23 |
ORCID | 0000-0001-7844-4881 |
PMID | 25056525 |
PQID | 1655456377 |
PQPubID | 1036384 |
PageCount | 8 |
ParticipantIDs | proquest_miscellaneous_1657324596 proquest_journals_1655456377 pubmed_primary_25056525 crossref_primary_10_1111_aos_12487 crossref_citationtrail_10_1111_aos_12487 wiley_primary_10_1111_aos_12487_AOS12487 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | March 2015 |
PublicationDateYYYYMMDD | 2015-03-01 |
PublicationDate_xml | – month: 03 year: 2015 text: March 2015 |
PublicationDecade | 2010 |
PublicationPlace | England |
PublicationPlace_xml | – name: England – name: Malden |
PublicationTitle | Acta ophthalmologica (Oxford, England) |
PublicationTitleAlternate | Acta Ophthalmol |
PublicationYear | 2015 |
Publisher | Wiley Subscription Services, Inc |
Publisher_xml | – name: Wiley Subscription Services, Inc |
References | 2004; 88 1995; 72 2010; 31 1982; 59 2007; 245 2010; 36 2002; 73 2011; 31 2013; 91 2008 2008; 10 1999; 8 1992; 12 1985; 27 2002; 47 2006; 83 2002; 42 2002; 46 1994; 35 2012; 7 2012; 89 2003; 43 2009; 148 2010; 50 1998; 14 1983; 23 e_1_2_6_10_1 e_1_2_6_19_1 e_1_2_6_13_1 e_1_2_6_14_1 e_1_2_6_11_1 e_1_2_6_12_1 e_1_2_6_18_1 e_1_2_6_15_1 e_1_2_6_16_1 Grimson JM (e_1_2_6_17_1) 2002; 73 Pomerance GN (e_1_2_6_27_1) 1994; 35 e_1_2_6_21_1 e_1_2_6_20_1 Swamy S (e_1_2_6_29_1) 2002; 46 e_1_2_6_9_1 e_1_2_6_8_1 e_1_2_6_5_1 e_1_2_6_4_1 Miller M (e_1_2_6_23_1) 2008 e_1_2_6_7_1 e_1_2_6_6_1 e_1_2_6_25_1 e_1_2_6_24_1 e_1_2_6_3_1 e_1_2_6_2_1 e_1_2_6_22_1 Wachler BSB (e_1_2_6_30_1) 1998; 14 e_1_2_6_28_1 e_1_2_6_26_1 |
References_xml | – volume: 7 start-page: e40239 year: 2012 article-title: Night myopia studied with an adaptive optics visula analyzer publication-title: PLoS One – volume: 27 start-page: 637 year: 1985 end-page: 642 article-title: Contrast sensitivity predicts age‐related differences in highway‐sign discriminability publication-title: Hum Factors – volume: 8 start-page: 135 year: 1999 end-page: 160 article-title: Measuring agreement in method comparison studies publication-title: Stat Methods Med Res – volume: 47 start-page: 533 year: 2002 end-page: 546 article-title: Night vision disturbances after corneal refractive surgery publication-title: Surv Ophthalmol – volume: 23 start-page: 689 year: 1983 end-page: 699 article-title: Contrast sensitivity throughout adulthood publication-title: Vision Res – volume: 88 start-page: 11 year: 2004 end-page: 16 article-title: The usefulness of Vistech and FACT contrast sensitivity charts for cataract and refractive surgery outcomes research publication-title: Br J Ophthalmol – volume: 83 start-page: 290 year: 2006 end-page: 298 article-title: Measuring contrast sensitivity under different lighting conditions: comparison of three tests publication-title: Optom Vis Sci – volume: 72 start-page: 186 year: 1995 end-page: 191 article-title: Visual acuity changes throughout adulthood in normal, healthy eyes: seeing beyond 6/6 publication-title: Optom Vis Sci – volume: 50 start-page: 2348 year: 2010 end-page: 2361 article-title: Vision and driving publication-title: Vision Res – volume: 31 start-page: 330 year: 2011 end-page: 338 article-title: Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology publication-title: Ophthalmic Physiol Opt – volume: 12 start-page: 275 year: 1992 end-page: 280 article-title: Clinical contrast sensitivity chart evaluation publication-title: Ophthalmic Physiol Opt – volume: 89 start-page: 1172 year: 2012 end-page: 1181 article-title: Reliability of the CSV‐1000 in adults and children publication-title: Optom Vis Sci – volume: 148 start-page: 4 year: 2009 end-page: 6 article-title: Correlation, agreement, and Bland‐Altman analysis: statistical analysis of method comparison studies publication-title: Am J Ophthalmol – volume: 43 start-page: 5 year: 2003 end-page: 15 article-title: Contrast sensitivity and functional vision publication-title: Int Ophthalmol Clin – volume: 59 start-page: 105 year: 1982 end-page: 109 article-title: Contrast sensitivity predicts pilots' performance in aircraft simulators publication-title: Am J Optom Physiol Opt – volume: 14 start-page: 463 year: 1998 end-page: 466 article-title: Normalized contrast sensitivity values publication-title: J Refract Surg – volume: 31 start-page: 758 year: 2010 end-page: 761 article-title: Comparison of the VCTS‐6500 and the CSV‐1000 tests for visual contrast sensitivity testing publication-title: Neurotoxicology – year: 2008 – volume: 10 start-page: 57 year: 2008 end-page: 66 article-title: The historical evolution of visual acuity measurement publication-title: Vis Impair Res – volume: 73 start-page: 28 year: 2002 end-page: 35 article-title: Contrast sensitivity: establishing normative data for use in screening prospective naval pilots publication-title: Aviat Space Environ Med – volume: 31 start-page: 123 year: 2011 end-page: 136 article-title: Statistical guidelines for clinical studies of human vision publication-title: Ophthalmic Physiol Opt – volume: 91 start-page: 312 year: 2013 end-page: 317 article-title: Age‐related change in contrast sensitivity among Australian male adults: Florey Adult Male Ageing Study publication-title: Acta Ophthalmol – volume: 36 start-page: 547 year: 2010 end-page: 552 article-title: Contrast sensitivity measurement with 2 contrast sensitivity tests in normal eyes and eyes with cataract publication-title: J Cataract Refract Surg – volume: 35 start-page: 3357 year: 1994 end-page: 3361 article-title: Test‐retest reliability of the CSV‐1000 contrast test and its relationship to glaucoma therapy publication-title: Invest Ophthalmol Vis Sci – volume: 46 start-page: 7 year: 2002 end-page: 22 article-title: Contrast sensitivity in IAF aircrew publication-title: Ind J Aerospace Med – volume: 91 start-page: 176 year: 2013 end-page: 182 article-title: Sine wave mesopic contrast sensitivity – defining the normal range in a young population publication-title: Acta Ophthalmol – volume: 42 start-page: 1205 year: 2002 end-page: 1210 article-title: Using a single test to measure human contrast sensitivity from early childhood to maturity publication-title: Vision Res – volume: 43 start-page: 31 year: 2003 end-page: 42 article-title: Contrast sensitivity and limits of vision publication-title: Int Ophthalmol Clin – volume: 245 start-page: 1805 year: 2007 end-page: 1814 article-title: Measuring contrast sensitivity in normal subjects with OPTEC 6500: influence of age and glare publication-title: Graefes Arch Clin Exp Ophthalmol – ident: e_1_2_6_10_1 doi: 10.1111/j.1475-1313.1992.tb00397.x – ident: e_1_2_6_26_1 doi: 10.1136/bjo.88.1.11 – ident: e_1_2_6_5_1 doi: 10.1371/journal.pone.0040239 – ident: e_1_2_6_21_1 doi: 10.1097/OPX.0b013e318264097b – volume-title: Encyclopedia of educational psychology year: 2008 ident: e_1_2_6_23_1 – ident: e_1_2_6_24_1 doi: 10.1016/j.visres.2010.05.021 – ident: e_1_2_6_2_1 doi: 10.1016/S0042-6989(02)00038-X – ident: e_1_2_6_7_1 doi: 10.1097/01.opx.0000216100.93302.2d – ident: e_1_2_6_12_1 doi: 10.1177/001872088502700602 – volume: 46 start-page: 7 year: 2002 ident: e_1_2_6_29_1 article-title: Contrast sensitivity in IAF aircrew publication-title: Ind J Aerospace Med – ident: e_1_2_6_4_1 doi: 10.1111/j.1475-1313.2010.00815.x – ident: e_1_2_6_11_1 doi: 10.1097/00006324-199503000-00006 – ident: e_1_2_6_6_1 doi: 10.1177/096228029900800204 – ident: e_1_2_6_8_1 doi: 10.1016/j.ajo.2008.09.032 – ident: e_1_2_6_19_1 doi: 10.1007/s00417-007-0662-x – volume: 14 start-page: 463 year: 1998 ident: e_1_2_6_30_1 article-title: Normalized contrast sensitivity values publication-title: J Refract Surg doi: 10.3928/1081-597X-19980701-14 – volume: 35 start-page: 3357 year: 1994 ident: e_1_2_6_27_1 article-title: Test‐retest reliability of the CSV‐1000 contrast test and its relationship to glaucoma therapy publication-title: Invest Ophthalmol Vis Sci – ident: e_1_2_6_13_1 doi: 10.1016/S0039-6257(02)00350-8 – ident: e_1_2_6_22_1 doi: 10.1111/j.1475-1313.2011.00851.x – ident: e_1_2_6_9_1 doi: 10.1080/13882350802632401 – ident: e_1_2_6_20_1 doi: 10.1016/j.jcrs.2009.10.048 – volume: 73 start-page: 28 year: 2002 ident: e_1_2_6_17_1 article-title: Contrast sensitivity: establishing normative data for use in screening prospective naval pilots publication-title: Aviat Space Environ Med – ident: e_1_2_6_16_1 doi: 10.1097/00006324-198201000-00020 – ident: e_1_2_6_25_1 doi: 10.1016/0042-6989(83)90210-9 – ident: e_1_2_6_28_1 doi: 10.1111/j.1755-3768.2011.02379.x – ident: e_1_2_6_15_1 doi: 10.1097/00004397-200343020-00004 – ident: e_1_2_6_14_1 doi: 10.1016/j.neuro.2010.06.004 – ident: e_1_2_6_3_1 doi: 10.1097/00004397-200343020-00006 – ident: e_1_2_6_18_1 doi: 10.1111/j.1755-3768.2011.02323.x |
SSID | ssj0061664 |
Score | 2.2151546 |
Snippet | Purpose
This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy,... This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults... Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy,... |
SourceID | proquest pubmed crossref wiley |
SourceType | Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 154 |
SubjectTerms | Adolescent Adult Color Vision - physiology contrast sensitivity Contrast Sensitivity - physiology Dark Adaptation - physiology Female Healthy Volunteers Humans Male medical selection mesopic vision Mesopic Vision - physiology Military Personnel Ophthalmology photopic vision Vision Tests - methods Visual Acuity - physiology visual function visual quality Young Adult |
Title | Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity |
URI | https://onlinelibrary.wiley.com/doi/abs/10.1111%2Faos.12487 https://www.ncbi.nlm.nih.gov/pubmed/25056525 https://www.proquest.com/docview/1655456377 https://www.proquest.com/docview/1657324596 |
Volume | 93 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
journalDatabaseRights | – providerCode: PRVEBS databaseName: EBSCOhost Academic Search Ultimate customDbUrl: https://search.ebscohost.com/login.aspx?authtype=ip,shib&custid=s3936755&profile=ehost&defaultdb=asn eissn: 1755-3768 dateEnd: 20240930 omitProxy: true ssIdentifier: ssj0061664 issn: 1755-375X databaseCode: ABDBF dateStart: 20080201 isFulltext: true titleUrlDefault: https://search.ebscohost.com/direct.asp?db=asn providerName: EBSCOhost – providerCode: PRVBFR databaseName: Free Medical Journals customDbUrl: eissn: 1755-3768 dateEnd: 20240930 omitProxy: true ssIdentifier: ssj0061664 issn: 1755-375X databaseCode: DIK dateStart: 20080101 isFulltext: true titleUrlDefault: http://www.freemedicaljournals.com providerName: Flying Publisher – providerCode: PRVWIB databaseName: Wiley Online Library - Core collection (SURFmarket) issn: 1755-375X databaseCode: DR2 dateStart: 19970101 customDbUrl: isFulltext: true eissn: 1755-3768 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0061664 providerName: Wiley-Blackwell |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3NS8MwFA_Dg3jx-2M6RxQPHuxY1yRt8TTEMRUV1MEOQknaFIazk7VV5l_vS9IW5weIpxaSNGnee8kvycvvIXQkAWTYEpRXSL9tEVswS4BNWW5EJG0zDxZz2sv3hvUH5HJIhzV0Wt6FMfwQ1Yabsgw9XisD5yL9ZOR8krZgcvLUTXLbofqI9q6ijmI209RRMDtSMCI6LFiFlBdPVXJ-LvoGMOfxqp5weivosWyq8TN5auWZaIXvX1gc__kvq2i5AKK4azRnDdVkso4Wr4uj9g2UKN6qKU8znCofdxNkAj-bLcUIixnO3ia4jK-SYYCsGTbxqFM8SrC5YDk7wTM1nmDN85Fite2LE4WTx_h1lObw4GEOX95Eg975w1nfKoIzWKHypLG8WLqe0yY8ciPH5cIF647bQvgkpJz5MYllB0TNeAQL8A6RkecwEkfCVxEYSIc4W2ghmSRyB2FCZSgcEcYeCxWdGrc5kZIJ15FEQPE6Oi7FFIQFc7kKoDEOyhUM9F-g-6-ODqusL4au46dMjVLWQWGxkMKoApOOC8kHVTLYmjpA4Ymc5DqPCwCU-tCkbaMjVS0aStIOhcZqSf9efdC9vdcvu3_PuoeWAKlR4_zWQAvZNJf7gIYy0QS1v7hqauX_ADXyB54 |
linkProvider | Wiley-Blackwell |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT9wwEB7xkAoXCi0ttNC6VQ89NKvdjR-J1AuCoi0FKvGQ9lJFduJIKyCLSALa_vrO2EkEfUiop0SyHTu2P_uzPf4G4INFkjGw2HmNjfsBHxgZGMRUoDJuRV9GuJhzVr7HcnTOD8ZiPAef27swXh-i23AjZLjxmgBOG9L3UK6nZQ9np0jNwyKdzxEs90468Sg5kE48CudHgTAS40ZXiOx4uqQPZ6M_KOZDxuqmnP2n8KMtrLc0uejVlemlP3_Tcfzfv1mFlYaLsh3fedZgzhbP4MlRc9r-HAqSrrrRZcVKMnP3fibYld9VzJiZsepuyloXKxVD1lox75K6ZJOC-TuWs09sRkMKc1IfJaOdX1YQVb5kt5OyxodOa_zyOpzvfznbHQWNf4YgJWOaIMqtisI-15nKQqWNQoDnfWNingot45zndoitLXWGa_Aht1kUSp5nJiYnDHzIwxewUEwLuwGMC5ua0KR5JFNSVNMDza2VRoWWG0y-CR_bdkrSRrycfGhcJu0iBusvcfW3Ce-7qNdeseNvkbbaxk4a0GKIFMQnQ4XB77pghBudoejCTmsXRyEHFTEW6aXvJF0ujk2KocDCuqb-d_bJzvdT9_Lq8VHfwtLo7OgwOfx6_O01LCNxE94WbgsWqpvabiM5qswbh4FfZaIKwQ |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1db9MwFL0aRap4YYyN0a1sZuKBB1K1jT8S8VQBVfnYhrZV6gNSZCeOVK1LqyYBdb-eazuJGDAJ8ZRItmPH9rGP7etzAV5pJBkDjZ1X6bDv0YHinkJMeSKhmvV5gIs5a-V7xidT-mnGZlvwtr4L4_Qhmg03gww7XhuAr5L0F5DLZd7DySkQD-Ah5bi6MozootGO4gNutaNwemSIIjarZIWMGU-T9O5k9AfDvEtY7Ywz3oZvdVmdocl1ryxUL779TcbxP3_mCTyumCgZua6zA1s6ewrt0-qsfRcyI1y1lnlBcmPk7rxMkBu3p5gQtSHFjyWpHawUBDlrQZxD6pzMM-JuWG7ekI0ZUIgV-siJ2fclmSHKC_J9npf4kHGJX96D6fjD1buJV3ln8GJjSuMFqRaB36cyEYkvpBII77SvVEhjJnmY0lQPsa25THAFPqQ6CXxO00SFxgUDHVL_GbSyZaafA6FMx8pXcRrw2OipyYGkWnMlfE0VJu_A67qZoriSLjceNBZRvYTB-ots_XXgpIm6cnodf4vUrds6qiCLIZwZNukLDH7ZBCPYzAmKzPSytHEEMlAWYpH2XR9pcrFckg0ZFta29P3ZR6PzS_ty8O9Rj6H99f04-vLx7PMhPELWxpwhXBdaxbrUL5AZFerIIuAnRZoJcA |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Contrast+sensitivity+measured+by+two+different+test+methods+in+healthy%2C+young+adults+with+normal+visual+acuity&rft.jtitle=Acta+ophthalmologica+%28Oxford%2C+England%29&rft.au=Koefoed%2C+Vilhelm+F.&rft.au=Baste%2C+Valborg&rft.au=Roumes%2C+Corinne&rft.au=H%C3%B8vding%2C+Gunnar&rft.date=2015-03-01&rft.issn=1755-375X&rft.eissn=1755-3768&rft.volume=93&rft.issue=2&rft.spage=154&rft.epage=161&rft_id=info:doi/10.1111%2Faos.12487&rft.externalDBID=n%2Fa&rft.externalDocID=10_1111_aos_12487 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1755-375X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1755-375X&client=summon |