Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity

Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to esta...

Full description

Saved in:
Bibliographic Details
Published inActa ophthalmologica (Oxford, England) Vol. 93; no. 2; pp. 154 - 161
Main Authors Koefoed, Vilhelm F., Baste, Valborg, Roumes, Corinne, Høvding, Gunnar
Format Journal Article
LanguageEnglish
Published England Wiley Subscription Services, Inc 01.03.2015
Subjects
Online AccessGet full text
ISSN1755-375X
1755-3768
1755-3768
DOI10.1111/aos.12487

Cover

Abstract Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Methods Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18–25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV‐1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland–Altman technique was used to analyse the agreement between ICS obtained by the different test methods. Results A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was −0.15 (95% percentile 0.45), compared with −0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV‐1000E. The mean difference between ICSFACT85 and ICSCSV was −0.43 (95% CI −0.56 to −0.30, p < 0.00) with limits of agreement (LoA) within −2.10 and 1.22. The regression line on the difference of average was near to zero (R2 = 0.03). Conclusion The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.
AbstractList This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03). The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.
Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Methods Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18–25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV‐1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland–Altman technique was used to analyse the agreement between ICS obtained by the different test methods. Results A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was −0.15 (95% percentile 0.45), compared with −0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV‐1000E. The mean difference between ICSFACT85 and ICSCSV was −0.43 (95% CI −0.56 to −0.30, p < 0.00) with limits of agreement (LoA) within −2.10 and 1.22. The regression line on the difference of average was near to zero (R2 = 0.03). Conclusion The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.
This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods.PURPOSEThis study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods.Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods.METHODSMilitary recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods.A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03).RESULTSA total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT 85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p<0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2=0.03).The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.CONCLUSIONThe results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.
Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults with normal uncorrected visual acuity. Based on these results, the index of contrast sensitivity (ICS) is calculated, aiming to establish ICS reference values for this population and to evaluate the possible usefulness of ICS as a tool to compare the degree of agreement between different CS test methods. Methods Military recruits with best eye uncorrected visual acuity 0.00 LogMAR or better, normal colour vision and age 18-25 years were included in a study to record contrast sensitivity using Optec 6500 (FACT) at spatial frequencies of 1.5, 3, 6, 12 and 18 cpd in photopic and mesopic light and CSV-1000E at spatial frequencies of 3, 6, 12 and 18 cpd in photopic light. Index of contrast sensitivity was calculated based on data from the three tests, and the Bland-Altman technique was used to analyse the agreement between ICS obtained by the different test methods. Results A total of 180 recruits were included. Contrast sensitivity frequency data for all tests were highly skewed with a marked ceiling effect for the photopic tests. The median ICS for Optec 6500 at 85 cd/m2 was -0.15 (95% percentile 0.45), compared with -0.00 (95% percentile 1.62) for Optec at 3 cd/m2 and 0.30 (95% percentile 1.20) FOR CSV-1000E. The mean difference between ICSFACT85 and ICSCSV was -0.43 (95% CI -0.56 to -0.30, p < 0.00) with limits of agreement (LoA) within -2.10 and 1.22. The regression line on the difference of average was near to zero (R2 = 0.03). Conclusion The results provide reference CS and ICS values in a young, adult population with normal visual acuity. The agreement between the photopic tests indicated that they may be used interchangeably. There was little agreement between the mesopic and photopic tests. The mesopic test seemed best suited to differentiate between candidates and may therefore possibly be useful for medical selection purposes.
Author Baste, Valborg
Høvding, Gunnar
Roumes, Corinne
Koefoed, Vilhelm F.
Author_xml – sequence: 1
  givenname: Vilhelm F.
  orcidid: 0000-0001-7844-4881
  surname: Koefoed
  fullname: Koefoed, Vilhelm F.
  organization: University of Bergen
– sequence: 2
  givenname: Valborg
  surname: Baste
  fullname: Baste, Valborg
  organization: University of Bergen
– sequence: 3
  givenname: Corinne
  surname: Roumes
  fullname: Roumes, Corinne
  organization: Institut de Recherche Biomédicale des Armées
– sequence: 4
  givenname: Gunnar
  surname: Høvding
  fullname: Høvding, Gunnar
  organization: University of Bergen
BackLink https://www.ncbi.nlm.nih.gov/pubmed/25056525$$D View this record in MEDLINE/PubMed
BookMark eNp90U1r3DAQBmBRUrrJtof-gSDoJYFuItv6sI9hSdJCIIek0JuRrVFWiy2l-sjifx9tdpvDQqvL6PDMMMx7go6ss4DQ14JcFPldShcuipLW4gM6LgRji0rw-uj9z37P0EkIa0J4wTn9hGYlI4yzkh0ju3Q2ehkiDmCDiebFxAmPIEPyoHA34bhxWBmtwYONOEKmI8SVUwEbi1cgh7iavuPJJfuEpUpDDHhj4gpb50c54BcTUi6yT3nyZ_RRyyHAl32do18314_LH4u7-9ufy6u7RU_LSixqDaKuCJVKqErIThBWaNJ1De2Z5I2mGkpeA5eK8qakoOqKU626hhFCaEmrOTrbzX327k_KO7ejCT0Mg7TgUmgLzkRVUtbwTL8d0LVL3ubttopRxishsjrdq9SNoNpnb0bpp_bvJTM434HeuxA86HdSkHabUptTat9SyvbywPYmymjeojDD_zo2ZoDp36Pbq_uHXccrrqSj2g
CitedBy_id crossref_primary_10_1038_s41598_024_52836_4
crossref_primary_10_1111_opo_13037
crossref_primary_10_1177_14771535211049816
crossref_primary_10_1186_s12886_022_02621_6
crossref_primary_10_1002_1348_9585_12279
crossref_primary_10_3928_1081597X_20240723_04
crossref_primary_10_1016_j_ajo_2019_07_001
crossref_primary_10_3758_s13414_016_1219_z
crossref_primary_10_1038_srep46706
crossref_primary_10_1093_milmed_usab071
crossref_primary_10_3341_jkos_2021_62_5_638
crossref_primary_10_1186_s12886_020_01549_z
crossref_primary_10_3389_fpsyg_2021_772661
crossref_primary_10_1097_ICL_0000000000000371
crossref_primary_10_4103_joco_joco_147_21
crossref_primary_10_3389_fpsyg_2018_00899
crossref_primary_10_3390_diagnostics14131377
crossref_primary_10_3390_technologies12070108
crossref_primary_10_1038_s41598_022_17448_w
crossref_primary_10_1111_aos_13673
Cites_doi 10.1111/j.1475-1313.1992.tb00397.x
10.1136/bjo.88.1.11
10.1371/journal.pone.0040239
10.1097/OPX.0b013e318264097b
10.1016/j.visres.2010.05.021
10.1016/S0042-6989(02)00038-X
10.1097/01.opx.0000216100.93302.2d
10.1177/001872088502700602
10.1111/j.1475-1313.2010.00815.x
10.1097/00006324-199503000-00006
10.1177/096228029900800204
10.1016/j.ajo.2008.09.032
10.1007/s00417-007-0662-x
10.3928/1081-597X-19980701-14
10.1016/S0039-6257(02)00350-8
10.1111/j.1475-1313.2011.00851.x
10.1080/13882350802632401
10.1016/j.jcrs.2009.10.048
10.1097/00006324-198201000-00020
10.1016/0042-6989(83)90210-9
10.1111/j.1755-3768.2011.02379.x
10.1097/00004397-200343020-00004
10.1016/j.neuro.2010.06.004
10.1097/00004397-200343020-00006
10.1111/j.1755-3768.2011.02323.x
ContentType Journal Article
Copyright 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd
2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
Copyright © 2015 Acta Ophthalmologica Scandinavica Foundation
Copyright_xml – notice: 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd
– notice: 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
– notice: Copyright © 2015 Acta Ophthalmologica Scandinavica Foundation
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7TK
7X8
DOI 10.1111/aos.12487
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
Neurosciences Abstracts
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
Neurosciences Abstracts
MEDLINE - Academic
DatabaseTitleList MEDLINE

MEDLINE - Academic
Neurosciences Abstracts
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 1755-3768
EndPage 161
ExternalDocumentID 3592872901
25056525
10_1111_aos_12487
AOS12487
Genre article
Research Support, Non-U.S. Gov't
Journal Article
GrantInformation_xml – fundername: Norwegian Centre of Maritime Medicine
– fundername: Royal Norwegian Navy
GroupedDBID ---
.3N
.55
.GA
.Y3
05W
0R~
10A
1OC
23M
24P
31~
33P
36B
3SF
4.4
50Y
50Z
51W
51X
52M
52N
52O
52P
52R
52S
52T
52U
52V
52W
52X
53G
5GY
5HH
5LA
5VS
66C
702
7PT
8-0
8-1
8-3
8-4
8-5
8UM
930
A01
A03
AAESR
AAEVG
AAHHS
AAHQN
AAIPD
AAMNL
AANLZ
AAONW
AASGY
AAXRX
AAYCA
AAZKR
ABCUV
ABDBF
ABEML
ABJNI
ABPVW
ABQWH
ABXGK
ACAHQ
ACCFJ
ACCZN
ACGFS
ACGOF
ACMXC
ACNCT
ACPOU
ACPRK
ACSCC
ACUHS
ACXBN
ACXQS
ADBBV
ADBTR
ADEOM
ADIZJ
ADKYN
ADMGS
ADOZA
ADXAS
ADZMN
ADZOD
AEEZP
AEIGN
AEIMD
AENEX
AEQDE
AEUQT
AEUYR
AFBPY
AFFPM
AFGKR
AFPWT
AFRAH
AFWVQ
AFZJQ
AHBTC
AHMBA
AIACR
AITYG
AIURR
AIWBW
AJBDE
ALAGY
ALMA_UNASSIGNED_HOLDINGS
ALUQN
ALVPJ
AMBMR
AMYDB
ASPBG
ATUGU
AVWKF
AZBYB
AZFZN
AZVAB
BAFTC
BAWUL
BFHJK
BHBCM
BMXJE
BROTX
BRXPI
BY8
C45
CAG
COF
CS3
D-6
D-7
D-E
D-F
DCZOG
DIK
DPXWK
DR2
DRFUL
DRMAN
DRSTM
E3Z
EAD
EAP
EBC
EBD
EBS
EJD
EMB
EMK
EMOBN
ESX
EX3
F00
F01
F04
F5P
FIJ
FUBAC
G-S
GODZA
H.X
HF~
HGLYW
HZI
HZ~
IPNFZ
IX1
J0M
K48
KBYEO
LATKE
LC2
LC3
LEEKS
LH4
LITHE
LOXES
LP6
LP7
LUTES
LW6
LYRES
MEWTI
MK4
MRFUL
MRMAN
MRSTM
MSFUL
MSMAN
MSSTM
MXFUL
MXMAN
MXSTM
N04
N05
N9A
NF~
O66
O9-
OIG
OK1
OVD
P2W
P2X
P2Z
P4B
P4D
P6G
PQQKQ
Q.N
Q11
QB0
R.K
RIWAO
RJQFR
ROL
RX1
SUPJJ
SV3
TEORI
TR2
TUS
UB1
V9Y
W8V
W99
WBKPD
WHWMO
WIH
WIJ
WIK
WIN
WOHZO
WOW
WQJ
WRC
WVDHM
WXI
WXSBR
X7M
XG1
~IA
~WT
AAYXX
AEYWJ
AGHNM
AGYGG
CITATION
AAMMB
AEFGJ
AGXDD
AIDQK
AIDYY
CGR
CUY
CVF
ECM
EIF
NPM
1OB
7TK
7X8
ID FETCH-LOGICAL-c4237-8fe78304ad7d37ab7051f0bb94c5a69f4fe268e6ad46924ed8364fdb950004243
IEDL.DBID DR2
ISSN 1755-375X
1755-3768
IngestDate Thu Sep 04 21:02:23 EDT 2025
Wed Aug 13 07:04:45 EDT 2025
Mon Jul 21 05:49:31 EDT 2025
Tue Jul 01 00:24:39 EDT 2025
Thu Apr 24 23:06:20 EDT 2025
Wed Jan 22 16:55:35 EST 2025
IsPeerReviewed true
IsScholarly true
Issue 2
Keywords photopic vision
visual quality
mesopic vision
contrast sensitivity
medical selection
visual function
Language English
License 2014 Acta Ophthalmologica Scandinavica Foundation. Published by John Wiley & Sons Ltd.
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c4237-8fe78304ad7d37ab7051f0bb94c5a69f4fe268e6ad46924ed8364fdb950004243
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ORCID 0000-0001-7844-4881
PMID 25056525
PQID 1655456377
PQPubID 1036384
PageCount 8
ParticipantIDs proquest_miscellaneous_1657324596
proquest_journals_1655456377
pubmed_primary_25056525
crossref_primary_10_1111_aos_12487
crossref_citationtrail_10_1111_aos_12487
wiley_primary_10_1111_aos_12487_AOS12487
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate March 2015
PublicationDateYYYYMMDD 2015-03-01
PublicationDate_xml – month: 03
  year: 2015
  text: March 2015
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
– name: Malden
PublicationTitle Acta ophthalmologica (Oxford, England)
PublicationTitleAlternate Acta Ophthalmol
PublicationYear 2015
Publisher Wiley Subscription Services, Inc
Publisher_xml – name: Wiley Subscription Services, Inc
References 2004; 88
1995; 72
2010; 31
1982; 59
2007; 245
2010; 36
2002; 73
2011; 31
2013; 91
2008
2008; 10
1999; 8
1992; 12
1985; 27
2002; 47
2006; 83
2002; 42
2002; 46
1994; 35
2012; 7
2012; 89
2003; 43
2009; 148
2010; 50
1998; 14
1983; 23
e_1_2_6_10_1
e_1_2_6_19_1
e_1_2_6_13_1
e_1_2_6_14_1
e_1_2_6_11_1
e_1_2_6_12_1
e_1_2_6_18_1
e_1_2_6_15_1
e_1_2_6_16_1
Grimson JM (e_1_2_6_17_1) 2002; 73
Pomerance GN (e_1_2_6_27_1) 1994; 35
e_1_2_6_21_1
e_1_2_6_20_1
Swamy S (e_1_2_6_29_1) 2002; 46
e_1_2_6_9_1
e_1_2_6_8_1
e_1_2_6_5_1
e_1_2_6_4_1
Miller M (e_1_2_6_23_1) 2008
e_1_2_6_7_1
e_1_2_6_6_1
e_1_2_6_25_1
e_1_2_6_24_1
e_1_2_6_3_1
e_1_2_6_2_1
e_1_2_6_22_1
Wachler BSB (e_1_2_6_30_1) 1998; 14
e_1_2_6_28_1
e_1_2_6_26_1
References_xml – volume: 7
  start-page: e40239
  year: 2012
  article-title: Night myopia studied with an adaptive optics visula analyzer
  publication-title: PLoS One
– volume: 27
  start-page: 637
  year: 1985
  end-page: 642
  article-title: Contrast sensitivity predicts age‐related differences in highway‐sign discriminability
  publication-title: Hum Factors
– volume: 8
  start-page: 135
  year: 1999
  end-page: 160
  article-title: Measuring agreement in method comparison studies
  publication-title: Stat Methods Med Res
– volume: 47
  start-page: 533
  year: 2002
  end-page: 546
  article-title: Night vision disturbances after corneal refractive surgery
  publication-title: Surv Ophthalmol
– volume: 23
  start-page: 689
  year: 1983
  end-page: 699
  article-title: Contrast sensitivity throughout adulthood
  publication-title: Vision Res
– volume: 88
  start-page: 11
  year: 2004
  end-page: 16
  article-title: The usefulness of Vistech and FACT contrast sensitivity charts for cataract and refractive surgery outcomes research
  publication-title: Br J Ophthalmol
– volume: 83
  start-page: 290
  year: 2006
  end-page: 298
  article-title: Measuring contrast sensitivity under different lighting conditions: comparison of three tests
  publication-title: Optom Vis Sci
– volume: 72
  start-page: 186
  year: 1995
  end-page: 191
  article-title: Visual acuity changes throughout adulthood in normal, healthy eyes: seeing beyond 6/6
  publication-title: Optom Vis Sci
– volume: 50
  start-page: 2348
  year: 2010
  end-page: 2361
  article-title: Vision and driving
  publication-title: Vision Res
– volume: 31
  start-page: 330
  year: 2011
  end-page: 338
  article-title: Statistical methods for conducting agreement (comparison of clinical tests) and precision (repeatability or reproducibility) studies in optometry and ophthalmology
  publication-title: Ophthalmic Physiol Opt
– volume: 12
  start-page: 275
  year: 1992
  end-page: 280
  article-title: Clinical contrast sensitivity chart evaluation
  publication-title: Ophthalmic Physiol Opt
– volume: 89
  start-page: 1172
  year: 2012
  end-page: 1181
  article-title: Reliability of the CSV‐1000 in adults and children
  publication-title: Optom Vis Sci
– volume: 148
  start-page: 4
  year: 2009
  end-page: 6
  article-title: Correlation, agreement, and Bland‐Altman analysis: statistical analysis of method comparison studies
  publication-title: Am J Ophthalmol
– volume: 43
  start-page: 5
  year: 2003
  end-page: 15
  article-title: Contrast sensitivity and functional vision
  publication-title: Int Ophthalmol Clin
– volume: 59
  start-page: 105
  year: 1982
  end-page: 109
  article-title: Contrast sensitivity predicts pilots' performance in aircraft simulators
  publication-title: Am J Optom Physiol Opt
– volume: 14
  start-page: 463
  year: 1998
  end-page: 466
  article-title: Normalized contrast sensitivity values
  publication-title: J Refract Surg
– volume: 31
  start-page: 758
  year: 2010
  end-page: 761
  article-title: Comparison of the VCTS‐6500 and the CSV‐1000 tests for visual contrast sensitivity testing
  publication-title: Neurotoxicology
– year: 2008
– volume: 10
  start-page: 57
  year: 2008
  end-page: 66
  article-title: The historical evolution of visual acuity measurement
  publication-title: Vis Impair Res
– volume: 73
  start-page: 28
  year: 2002
  end-page: 35
  article-title: Contrast sensitivity: establishing normative data for use in screening prospective naval pilots
  publication-title: Aviat Space Environ Med
– volume: 31
  start-page: 123
  year: 2011
  end-page: 136
  article-title: Statistical guidelines for clinical studies of human vision
  publication-title: Ophthalmic Physiol Opt
– volume: 91
  start-page: 312
  year: 2013
  end-page: 317
  article-title: Age‐related change in contrast sensitivity among Australian male adults: Florey Adult Male Ageing Study
  publication-title: Acta Ophthalmol
– volume: 36
  start-page: 547
  year: 2010
  end-page: 552
  article-title: Contrast sensitivity measurement with 2 contrast sensitivity tests in normal eyes and eyes with cataract
  publication-title: J Cataract Refract Surg
– volume: 35
  start-page: 3357
  year: 1994
  end-page: 3361
  article-title: Test‐retest reliability of the CSV‐1000 contrast test and its relationship to glaucoma therapy
  publication-title: Invest Ophthalmol Vis Sci
– volume: 46
  start-page: 7
  year: 2002
  end-page: 22
  article-title: Contrast sensitivity in IAF aircrew
  publication-title: Ind J Aerospace Med
– volume: 91
  start-page: 176
  year: 2013
  end-page: 182
  article-title: Sine wave mesopic contrast sensitivity – defining the normal range in a young population
  publication-title: Acta Ophthalmol
– volume: 42
  start-page: 1205
  year: 2002
  end-page: 1210
  article-title: Using a single test to measure human contrast sensitivity from early childhood to maturity
  publication-title: Vision Res
– volume: 43
  start-page: 31
  year: 2003
  end-page: 42
  article-title: Contrast sensitivity and limits of vision
  publication-title: Int Ophthalmol Clin
– volume: 245
  start-page: 1805
  year: 2007
  end-page: 1814
  article-title: Measuring contrast sensitivity in normal subjects with OPTEC 6500: influence of age and glare
  publication-title: Graefes Arch Clin Exp Ophthalmol
– ident: e_1_2_6_10_1
  doi: 10.1111/j.1475-1313.1992.tb00397.x
– ident: e_1_2_6_26_1
  doi: 10.1136/bjo.88.1.11
– ident: e_1_2_6_5_1
  doi: 10.1371/journal.pone.0040239
– ident: e_1_2_6_21_1
  doi: 10.1097/OPX.0b013e318264097b
– volume-title: Encyclopedia of educational psychology
  year: 2008
  ident: e_1_2_6_23_1
– ident: e_1_2_6_24_1
  doi: 10.1016/j.visres.2010.05.021
– ident: e_1_2_6_2_1
  doi: 10.1016/S0042-6989(02)00038-X
– ident: e_1_2_6_7_1
  doi: 10.1097/01.opx.0000216100.93302.2d
– ident: e_1_2_6_12_1
  doi: 10.1177/001872088502700602
– volume: 46
  start-page: 7
  year: 2002
  ident: e_1_2_6_29_1
  article-title: Contrast sensitivity in IAF aircrew
  publication-title: Ind J Aerospace Med
– ident: e_1_2_6_4_1
  doi: 10.1111/j.1475-1313.2010.00815.x
– ident: e_1_2_6_11_1
  doi: 10.1097/00006324-199503000-00006
– ident: e_1_2_6_6_1
  doi: 10.1177/096228029900800204
– ident: e_1_2_6_8_1
  doi: 10.1016/j.ajo.2008.09.032
– ident: e_1_2_6_19_1
  doi: 10.1007/s00417-007-0662-x
– volume: 14
  start-page: 463
  year: 1998
  ident: e_1_2_6_30_1
  article-title: Normalized contrast sensitivity values
  publication-title: J Refract Surg
  doi: 10.3928/1081-597X-19980701-14
– volume: 35
  start-page: 3357
  year: 1994
  ident: e_1_2_6_27_1
  article-title: Test‐retest reliability of the CSV‐1000 contrast test and its relationship to glaucoma therapy
  publication-title: Invest Ophthalmol Vis Sci
– ident: e_1_2_6_13_1
  doi: 10.1016/S0039-6257(02)00350-8
– ident: e_1_2_6_22_1
  doi: 10.1111/j.1475-1313.2011.00851.x
– ident: e_1_2_6_9_1
  doi: 10.1080/13882350802632401
– ident: e_1_2_6_20_1
  doi: 10.1016/j.jcrs.2009.10.048
– volume: 73
  start-page: 28
  year: 2002
  ident: e_1_2_6_17_1
  article-title: Contrast sensitivity: establishing normative data for use in screening prospective naval pilots
  publication-title: Aviat Space Environ Med
– ident: e_1_2_6_16_1
  doi: 10.1097/00006324-198201000-00020
– ident: e_1_2_6_25_1
  doi: 10.1016/0042-6989(83)90210-9
– ident: e_1_2_6_28_1
  doi: 10.1111/j.1755-3768.2011.02379.x
– ident: e_1_2_6_15_1
  doi: 10.1097/00004397-200343020-00004
– ident: e_1_2_6_14_1
  doi: 10.1016/j.neuro.2010.06.004
– ident: e_1_2_6_3_1
  doi: 10.1097/00004397-200343020-00006
– ident: e_1_2_6_18_1
  doi: 10.1111/j.1755-3768.2011.02323.x
SSID ssj0061664
Score 2.2151546
Snippet Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy,...
This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy, young adults...
Purpose This study reports contrast sensitivity (CS) reference values obtained by two different test methods in a strictly selected population of healthy,...
SourceID proquest
pubmed
crossref
wiley
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 154
SubjectTerms Adolescent
Adult
Color Vision - physiology
contrast sensitivity
Contrast Sensitivity - physiology
Dark Adaptation - physiology
Female
Healthy Volunteers
Humans
Male
medical selection
mesopic vision
Mesopic Vision - physiology
Military Personnel
Ophthalmology
photopic vision
Vision Tests - methods
Visual Acuity - physiology
visual function
visual quality
Young Adult
Title Contrast sensitivity measured by two different test methods in healthy, young adults with normal visual acuity
URI https://onlinelibrary.wiley.com/doi/abs/10.1111%2Faos.12487
https://www.ncbi.nlm.nih.gov/pubmed/25056525
https://www.proquest.com/docview/1655456377
https://www.proquest.com/docview/1657324596
Volume 93
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVEBS
  databaseName: EBSCOhost Academic Search Ultimate
  customDbUrl: https://search.ebscohost.com/login.aspx?authtype=ip,shib&custid=s3936755&profile=ehost&defaultdb=asn
  eissn: 1755-3768
  dateEnd: 20240930
  omitProxy: true
  ssIdentifier: ssj0061664
  issn: 1755-375X
  databaseCode: ABDBF
  dateStart: 20080201
  isFulltext: true
  titleUrlDefault: https://search.ebscohost.com/direct.asp?db=asn
  providerName: EBSCOhost
– providerCode: PRVBFR
  databaseName: Free Medical Journals
  customDbUrl:
  eissn: 1755-3768
  dateEnd: 20240930
  omitProxy: true
  ssIdentifier: ssj0061664
  issn: 1755-375X
  databaseCode: DIK
  dateStart: 20080101
  isFulltext: true
  titleUrlDefault: http://www.freemedicaljournals.com
  providerName: Flying Publisher
– providerCode: PRVWIB
  databaseName: Wiley Online Library - Core collection (SURFmarket)
  issn: 1755-375X
  databaseCode: DR2
  dateStart: 19970101
  customDbUrl:
  isFulltext: true
  eissn: 1755-3768
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0061664
  providerName: Wiley-Blackwell
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3NS8MwFA_Dg3jx-2M6RxQPHuxY1yRt8TTEMRUV1MEOQknaFIazk7VV5l_vS9IW5weIpxaSNGnee8kvycvvIXQkAWTYEpRXSL9tEVswS4BNWW5EJG0zDxZz2sv3hvUH5HJIhzV0Wt6FMfwQ1Yabsgw9XisD5yL9ZOR8krZgcvLUTXLbofqI9q6ijmI209RRMDtSMCI6LFiFlBdPVXJ-LvoGMOfxqp5weivosWyq8TN5auWZaIXvX1gc__kvq2i5AKK4azRnDdVkso4Wr4uj9g2UKN6qKU8znCofdxNkAj-bLcUIixnO3ia4jK-SYYCsGTbxqFM8SrC5YDk7wTM1nmDN85Fite2LE4WTx_h1lObw4GEOX95Eg975w1nfKoIzWKHypLG8WLqe0yY8ciPH5cIF647bQvgkpJz5MYllB0TNeAQL8A6RkecwEkfCVxEYSIc4W2ghmSRyB2FCZSgcEcYeCxWdGrc5kZIJ15FEQPE6Oi7FFIQFc7kKoDEOyhUM9F-g-6-ODqusL4au46dMjVLWQWGxkMKoApOOC8kHVTLYmjpA4Ymc5DqPCwCU-tCkbaMjVS0aStIOhcZqSf9efdC9vdcvu3_PuoeWAKlR4_zWQAvZNJf7gIYy0QS1v7hqauX_ADXyB54
linkProvider Wiley-Blackwell
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1LT9wwEB7xkAoXCi0ttNC6VQ89NKvdjR-J1AuCoi0FKvGQ9lJFduJIKyCLSALa_vrO2EkEfUiop0SyHTu2P_uzPf4G4INFkjGw2HmNjfsBHxgZGMRUoDJuRV9GuJhzVr7HcnTOD8ZiPAef27swXh-i23AjZLjxmgBOG9L3UK6nZQ9np0jNwyKdzxEs90468Sg5kE48CudHgTAS40ZXiOx4uqQPZ6M_KOZDxuqmnP2n8KMtrLc0uejVlemlP3_Tcfzfv1mFlYaLsh3fedZgzhbP4MlRc9r-HAqSrrrRZcVKMnP3fibYld9VzJiZsepuyloXKxVD1lox75K6ZJOC-TuWs09sRkMKc1IfJaOdX1YQVb5kt5OyxodOa_zyOpzvfznbHQWNf4YgJWOaIMqtisI-15nKQqWNQoDnfWNingot45zndoitLXWGa_Aht1kUSp5nJiYnDHzIwxewUEwLuwGMC5ua0KR5JFNSVNMDza2VRoWWG0y-CR_bdkrSRrycfGhcJu0iBusvcfW3Ce-7qNdeseNvkbbaxk4a0GKIFMQnQ4XB77pghBudoejCTmsXRyEHFTEW6aXvJF0ujk2KocDCuqb-d_bJzvdT9_Lq8VHfwtLo7OgwOfx6_O01LCNxE94WbgsWqpvabiM5qswbh4FfZaIKwQ
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1db9MwFL0aRap4YYyN0a1sZuKBB1K1jT8S8VQBVfnYhrZV6gNSZCeOVK1LqyYBdb-eazuJGDAJ8ZRItmPH9rGP7etzAV5pJBkDjZ1X6bDv0YHinkJMeSKhmvV5gIs5a-V7xidT-mnGZlvwtr4L4_Qhmg03gww7XhuAr5L0F5DLZd7DySkQD-Ah5bi6MozootGO4gNutaNwemSIIjarZIWMGU-T9O5k9AfDvEtY7Ywz3oZvdVmdocl1ryxUL779TcbxP3_mCTyumCgZua6zA1s6ewrt0-qsfRcyI1y1lnlBcmPk7rxMkBu3p5gQtSHFjyWpHawUBDlrQZxD6pzMM-JuWG7ekI0ZUIgV-siJ2fclmSHKC_J9npf4kHGJX96D6fjD1buJV3ln8GJjSuMFqRaB36cyEYkvpBII77SvVEhjJnmY0lQPsa25THAFPqQ6CXxO00SFxgUDHVL_GbSyZaafA6FMx8pXcRrw2OipyYGkWnMlfE0VJu_A67qZoriSLjceNBZRvYTB-ots_XXgpIm6cnodf4vUrds6qiCLIZwZNukLDH7ZBCPYzAmKzPSytHEEMlAWYpH2XR9pcrFckg0ZFta29P3ZR6PzS_ty8O9Rj6H99f04-vLx7PMhPELWxpwhXBdaxbrUL5AZFerIIuAnRZoJcA
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Contrast+sensitivity+measured+by+two+different+test+methods+in+healthy%2C+young+adults+with+normal+visual+acuity&rft.jtitle=Acta+ophthalmologica+%28Oxford%2C+England%29&rft.au=Koefoed%2C+Vilhelm+F.&rft.au=Baste%2C+Valborg&rft.au=Roumes%2C+Corinne&rft.au=H%C3%B8vding%2C+Gunnar&rft.date=2015-03-01&rft.issn=1755-375X&rft.eissn=1755-3768&rft.volume=93&rft.issue=2&rft.spage=154&rft.epage=161&rft_id=info:doi/10.1111%2Faos.12487&rft.externalDBID=n%2Fa&rft.externalDocID=10_1111_aos_12487
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1755-375X&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1755-375X&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1755-375X&client=summon