Risk Factors of Complications after CT-guided Percutaneous Needle Biopsy of Lumps Near Pulmonary Hilum
The factors influencing the incidence of common complications(pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complicat...
Saved in:
Published in | Journal of Huazhong University of Science and Technology. Medical sciences Vol. 35; no. 2; pp. 278 - 282 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
Heidelberg
Huazhong University of Science and Technology
01.04.2015
Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China |
Subjects | |
Online Access | Get full text |
ISSN | 1672-0733 1993-1352 |
DOI | 10.1007/s11596-015-1424-3 |
Cover
Abstract | The factors influencing the incidence of common complications(pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax(13 cases, 27.1%) and pulmonary hemorrhage(14 cases, 20.24%). ?2 test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases(17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases(60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases(41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases(70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation. Key words: biopsy, CT-guided; hilum; pneumothorax; pulmonary hemorrhage |
---|---|
AbstractList | The factors influencing the incidence of common complications(pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax(13 cases, 27.1%) and pulmonary hemorrhage(14 cases, 20.24%). ?2 test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases(17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases(60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases(41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases(70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation. Key words: biopsy, CT-guided; hilum; pneumothorax; pulmonary hemorrhage Summary The factors influencing the incidence of common complications (pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax (13 cases, 27.1%) and pulmonary hemorrhage (14 cases, 20.24%). χ 2 test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases (17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases (60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases (41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases (70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation. The factors influencing the incidence of common complications (pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax (13 cases, 27.1%) and pulmonary hemorrhage (14 cases, 20.24%). χ(2) test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases (17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases (60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases (41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases (70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation. The factors influencing the incidence of common complications (pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax (13 cases, 27.1%) and pulmonary hemorrhage (14 cases, 20.24%). χ(2) test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases (17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases (60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases (41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases (70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation.The factors influencing the incidence of common complications (pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax (13 cases, 27.1%) and pulmonary hemorrhage (14 cases, 20.24%). χ(2) test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases (17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases (60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases (41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases (70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation. |
Author | 尹中元 林振宇 王晔 李鹏程 沈楠 王琼 叶挺 邹枕玮 吴边 杨坤禹 伍钢 |
AuthorAffiliation | Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China |
AuthorAffiliation_xml | – name: Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China |
Author_xml | – sequence: 1 fullname: 尹中元 林振宇 王晔 李鹏程 沈楠 王琼 叶挺 邹枕玮 吴边 杨坤禹 伍钢 |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/25877365$$D View this record in MEDLINE/PubMed |
BookMark | eNp9kV1vFCEUholpYz_0B3hjiFcmBuVjgJlL3bTWZFMbU68Jw8DKdgamMJN2_72ss9XEi15ByPOcw3nPGTgKMVgA3hD8kWAsP2VCeCMQJhyRilaIvQCnpGkYIozTo3IXkiIsGTsBZzlvMeZS0OolOKG8lpIJfgrcD5_v4KU2U0wZRgdXcRh7b_TkY8hQu8kmuLpFm9l3toM3Npl50sHGOcNra7vewi8-jnm3d9fzMO6fdYI3cz_EoNMOXvl-Hl6BY6f7bF8fznPw8_LidnWF1t-_flt9XiNTYTkhIZ2rnJYtIdS5GstWOssdIYJS0zV121AqKqkFl9ZgZrCrbeekabFs6ooIdg4-LHUfdHA6bNQ2zimUjmra7u66x8dWWVrywhRTUuj3Cz2meD_bPKnBZ2P7fhlQlfwqilktZEHfHtC5HWynxuSHMp16SrIAcgFMijkn65Tx058Up6R9rwhW-52pZWeq_EHtd6ZYMcl_5lPx5xy6OLmwYWPTv0Gfk94dGv2KYXNfvL-dhKiYFBxz9huy3LNl |
CitedBy_id | crossref_primary_10_1007_s00330_016_4718_3 crossref_primary_10_1186_s12957_023_03211_6 crossref_primary_10_1177_0300060520983141 |
Cites_doi | 10.1378/chest.126.3.748 10.1126/science.1099314 10.1053/crad.2000.0964 10.2214/ajr.172.4.10587145 10.1259/bjr.75.897.750731 10.1148/radiology.198.3.8628859 10.1007/s00330-012-2644-6 10.1016/S0033-8389(05)70162-7 10.1136/thorax.58.11.920 10.1148/radiology.169.3.3055026 10.1148/radiology.198.2.8596834 10.1016/j.rmed.2008.09.010 10.1097/01.RVI.0000124951.24134.50 10.1378/chest.109.3.616 10.1148/radiol.13131265 10.3322/caac.20107 10.1080/02841850802294410 10.1159/000209966 10.1378/chest.121.5.1521 10.1097/01.RVI.0000071087.76348.C7 10.1148/radiology.212.1.r99jl33165 |
ContentType | Journal Article |
Copyright | Huazhong University of Science and Technology and Springer-Verlag Berlin Heidelberg 2015 Copyright © Wanfang Data Co. Ltd. All Rights Reserved. |
Copyright_xml | – notice: Huazhong University of Science and Technology and Springer-Verlag Berlin Heidelberg 2015 – notice: Copyright © Wanfang Data Co. Ltd. All Rights Reserved. |
DBID | 2RA 92L CQIGP W91 ~WA AAYXX CITATION CGR CUY CVF ECM EIF NPM 7X8 2B. 4A8 92I 93N PSX TCJ |
DOI | 10.1007/s11596-015-1424-3 |
DatabaseName | 维普期刊资源整合服务平台 中文科技期刊数据库-CALIS站点 中文科技期刊数据库-7.0平台 中文科技期刊数据库-医药卫生 中文科技期刊数据库- 镜像站点 CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic Wanfang Data Journals - Hong Kong WANFANG Data Centre Wanfang Data Journals 万方数据期刊 - 香港版 China Online Journals (COJ) China Online Journals (COJ) |
DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
DatabaseTitleList | MEDLINE MEDLINE - Academic |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Medicine |
DocumentTitleAlternate | Risk Factors of Complications after CT-guided Percutaneous Needle Biopsy of Lumps Near Pulmonary Hilum |
EISSN | 1993-1352 |
EndPage | 282 |
ExternalDocumentID | tjykdxxb_e201502021 25877365 10_1007_s11596_015_1424_3 664376505 |
Genre | Research Support, Non-U.S. Gov't Journal Article |
GrantInformation_xml | – fundername: the National Natural Science Foundation of China funderid: (81102074) |
GroupedDBID | -5E -5G -BR -Y2 -~C .86 .VR 06C 06D 0R~ 0VY 1N0 29K 29~ 2B. 2C~ 2J2 2KG 2KM 2LR 2RA 2~H 30V 4.4 408 40D 40E 53G 5GY 5VS 6NX 8TC 8UJ 92F 92I 92L 95- 95. 95~ 96X AAAVM AABHQ AAJKR AANXM AARHV AARTL AAYIU AAYQN AAYTO ABFTV ABJNI ABJOX ABKCH ABMNI ABNWP ABQBU ABTMW ACGFS ACHXU ACKNC ACOMO ACSNA ACUDM ADHIR ADINQ ADKPE ADURQ ADYFF ADZKW AEBTG AEGNC AEJHL AEKMD AEOHA AEPYU AETLH AEXYK AFWTZ AFZKB AGAYW AGDGC AGQMX AGWIL AGWZB AGYKE AHAVH AHBYD AHKAY AHYZX AIIXL AJBLW AJRNO ALMA_UNASSIGNED_HOLDINGS ALWAN AMKLP ARMRJ AZFZN B-. BA0 BGNMA CAG CCEZO CHBEP CIEJG COF CQIGP CS3 CSCUP CW9 D-I DPUIP EBS EJD ESBYG FA0 FEDTE FNLPD FRRFC FWDCC G-Y G-Z GGCAI GGRSB GJIRD GQ6 GQ7 HF~ HG6 HMJXF HRMNR HVGLF HZ~ IJ- IXD I~X I~Z J-C JBSCW JUIAU KOV M4Y MA- N2Q NDZJH NQJWS NU0 O9- O93 O9I O9J P9S PF0 QOR QOS R-E R89 R9I RIG ROL RPX RSV S.. S16 S1Z S27 S37 S3B SAP SCL SDH SHX SMD SNE SNX SOJ SPISZ SZ9 SZN T13 TCJ TSG TT1 TUC U2A U9L UG4 VC2 W48 W91 WK8 Z7U Z82 Z8V ZOVNA ~A9 ~WA ABQSL H13 AAYXX ADHKG AGQPQ CITATION CGR CUY CVF ECM EIF NPM 7X8 4A8 93N PSX |
ID | FETCH-LOGICAL-c407t-67ff4fa7b112ff807b7fe5f11622cd98b922647a657ec03c0f8edf7cb07984163 |
IEDL.DBID | AGYKE |
ISSN | 1672-0733 |
IngestDate | Thu May 29 04:06:47 EDT 2025 Fri Sep 05 06:48:42 EDT 2025 Thu Apr 03 06:58:38 EDT 2025 Wed Oct 01 00:36:00 EDT 2025 Thu Apr 24 23:04:08 EDT 2025 Fri Feb 21 02:37:17 EST 2025 Wed Feb 14 10:30:19 EST 2024 |
IsPeerReviewed | false |
IsScholarly | false |
Issue | 2 |
Keywords | biopsy pulmonary hemorrhage hilum CT-guided pneumothorax biopsy,CT-guided |
Language | English |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c407t-67ff4fa7b112ff807b7fe5f11622cd98b922647a657ec03c0f8edf7cb07984163 |
Notes | The factors influencing the incidence of common complications(pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near pulmonary hilum were investigated. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum was performed on 48 patients. The complications of pneumothorax and pneumorrhagia as well as the contributing factors were analyzed statistically. The major complications associated with CT-guided needle biopsy included pneumothorax(13 cases, 27.1%) and pulmonary hemorrhage(14 cases, 20.24%). ?2 test revealed that pneumothorax was associated with the lesion size and depth of needle penetration, and pulmonary hemorrhage with the depth of needle penetration and needle retention time with a significant P value. Pneumothorax was observed in 7 cases(17.5%) out of 40 cases with diameter of mass greater than 3 cm, and in 6 cases(60%) out of 10 cases with depth of needle penetration greater than 4 cm. Additionally, pulmonary hemorrhage was identified in 12 cases(41.4%) out of 29 cases with needle retention time longer than 15 min, and pulmonary hemorrhage in 7 cases(70%) out of 10 cases with depth of needle penetration greater than 4 cm. CT-guided percutaneous needle biopsy of lumps near pulmonary hilum is safe and effective. The key factors to prevent the complications include correct evaluation of lesion size, depth of needle penetration and the needle retention time before the operation. Key words: biopsy, CT-guided; hilum; pneumothorax; pulmonary hemorrhage guided needle hilum penetration retention biopsy contributing statistically puncture incidence 42-1679/R Zhong-yuan YIN , Zhen-yu LIN , Ye WANG , Peng-cheng LI , Nan SHEN ,Qiong WANG , Ting YE, Zhen-wei ZOU , Bian WU, Kun-yu YANG, Gang WU (Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China) ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
PMID | 25877365 |
PQID | 1674203867 |
PQPubID | 23479 |
PageCount | 5 |
ParticipantIDs | wanfang_journals_tjykdxxb_e201502021 proquest_miscellaneous_1674203867 pubmed_primary_25877365 crossref_citationtrail_10_1007_s11596_015_1424_3 crossref_primary_10_1007_s11596_015_1424_3 springer_journals_10_1007_s11596_015_1424_3 chongqing_primary_664376505 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2015-04-01 |
PublicationDateYYYYMMDD | 2015-04-01 |
PublicationDate_xml | – month: 04 year: 2015 text: 2015-04-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | Heidelberg |
PublicationPlace_xml | – name: Heidelberg – name: China |
PublicationSubtitle | Medical Sciences |
PublicationTitle | Journal of Huazhong University of Science and Technology. Medical sciences |
PublicationTitleAbbrev | J. Huazhong Univ. Sci. Technol. [Med. Sci.] |
PublicationTitleAlternate | Journal of Zuazhong University of Science and Technology: Medical Edition |
PublicationTitle_FL | Journal of Huazhong University of Science and Technology(Medical Science) |
PublicationYear | 2015 |
Publisher | Huazhong University of Science and Technology Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China |
Publisher_xml | – name: Huazhong University of Science and Technology – name: Cancer Center, Union Hospital, Tongji Medical College, Huazhong University of Science and Technology, Wuhan 430023, China |
References | Yeow, Su, Pan (CR9) 2004; 126 Yeow, Tsay, Cheung (CR12) 2003; 14 Chen, Chang, Cheung (CR4) 2008; 49 Richardson, Pointon, Manhire (CR19) 2002; 75 Biswajit, John, Rakesh (CR18) 2009; 103 Lee, Park, Lee (CR22) 2014; 271 Jemal, Bray, Center (CR1) 2011; 61 Kazerooni, Lim, Mikhail (CR13) 1996; 198 Choo, Park, Lee (CR21) 2013; 23 Yankelevitz, Vazquez, Henschke (CR23) 2000; 38 Laurent, Michel, Latrabe (CR15) 1999; 172 Charig, Phillips (CR6) 2000; 55 Westcott (CR2) 1988; 169 Paez, Jänne, Lee (CR3) 2004; 304 Klein, Salomon, Stewart (CR8) 1996; 198 Vallop, Chalida, Kobkul (CR17) 2009; 92 Saji, Nakamura, Tsuchida (CR11) 2002; 121 Cox, Chiles, McManus (CR14) 1999; 212 Bunyaviroch, Coleman (CR5) 2006; 47 Covey, Gandhi, Brody (CR10) 2004; 15 Manhire, Charig, Clelland (CR20) 2003; 58 Steil, Zerwas, Moos (CR7) 2009; 32 Kazerooni, Hartker, Whyte (CR16) 1996; 109 A Jemal (1424_CR1) 2011; 61 AM Covey (1424_CR10) 2004; 15 JY Choo (1424_CR21) 2013; 23 H Saji (1424_CR11) 2002; 121 JE Cox (1424_CR14) 1999; 212 T Bunyaviroch (1424_CR5) 2006; 47 KM Yeow (1424_CR9) 2004; 126 KM Yeow (1424_CR12) 2003; 14 C Biswajit (1424_CR18) 2009; 103 S Steil (1424_CR7) 2009; 32 EA Kazerooni (1424_CR13) 1996; 198 JG Paez (1424_CR3) 2004; 304 CM Richardson (1424_CR19) 2002; 75 F Laurent (1424_CR15) 1999; 172 JL Westcott (1424_CR2) 1988; 169 EA Kazerooni (1424_CR16) 1996; 109 DF Yankelevitz (1424_CR23) 2000; 38 SM Lee (1424_CR22) 2014; 271 A Manhire (1424_CR20) 2003; 58 MJ Charig (1424_CR6) 2000; 55 L Vallop (1424_CR17) 2009; 92 CM Chen (1424_CR4) 2008; 49 JS Klein (1424_CR8) 1996; 198 12761311 - J Vasc Interv Radiol. 2003 May;14 (5):581-8 22976917 - Eur Radiol. 2013 Mar;23 (3):712-9 16513615 - J Nucl Med. 2006 Mar;47(3):451-69 8617066 - Chest. 1996 Mar;109 (3):616-19 19420971 - Onkologie. 2009 May;32(5):254-8 21296855 - CA Cancer J Clin. 2011 Mar-Apr;61(2):69-90 15364752 - Chest. 2004 Sep;126(3):748-54 10587145 - AJR Am J Roentgenol. 1999 Apr;172(4):1049-53 8596834 - Radiology. 1996 Feb;198(2):371-5 12006438 - Chest. 2002 May;121(5):1521-6 19626814 - J Med Assoc Thai. 2009 Jul;92(7):939-46 24475839 - Radiology. 2014 Apr;271(1):291-300 11124077 - Clin Radiol. 2000 Dec;55(12 ):964-9 8628859 - Radiology. 1996 Mar;198(3):715-20 10405737 - Radiology. 1999 Jul;212(1):165-8 14586042 - Thorax. 2003 Nov;58(11):920-36 15126658 - J Vasc Interv Radiol. 2004 May;15(5):479-83 3055026 - Radiology. 1988 Dec;169(3):593-601 18651255 - Acta Radiol. 2008 Nov;49(9):991-4 10765389 - Radiol Clin North Am. 2000 Mar;38(2):267-79 15118125 - Science. 2004 Jun 4;304(5676):1497-500 12200241 - Br J Radiol. 2002 Sep;75(897):731-5 18977128 - Respir Med. 2009 Mar;103(3):449-55 |
References_xml | – volume: 126 start-page: 748 issue: 3 year: 2004 end-page: 754 ident: CR9 article-title: Risk factors of pneumothorax and bleeding: multivariate analysis of 660 CT-guided coaxial cutting needle lung biopsies publication-title: Chest doi: 10.1378/chest.126.3.748 – volume: 304 start-page: 1497 issue: 5676 year: 2004 end-page: 1500 ident: CR3 article-title: EGFR mutations in lung cancer: correlation with clinical response to geitinib therapy publication-title: Science doi: 10.1126/science.1099314 – volume: 55 start-page: 964 issue: 12 year: 2000 end-page: 969 ident: CR6 article-title: CT-guided cutting needle biopsy of lung lesions: safety and efficacy of an outpatient service publication-title: Clin Radiol doi: 10.1053/crad.2000.0964 – volume: 172 start-page: 1049 issue: 4 year: 1999 end-page: 1053 ident: CR15 article-title: Pneumothorax and chest tube placement after CT-guided transthoracic lung biopsy using a coaxial technique: incidence and risk factors publication-title: Am J Roentgenol doi: 10.2214/ajr.172.4.10587145 – volume: 75 start-page: 731 issue: 897 year: 2002 end-page: 735 ident: CR19 article-title: Percutaneous lung biopsies: a survey of UK practice based on 5444 biopsies publication-title: Br J Radiol doi: 10.1259/bjr.75.897.750731 – volume: 198 start-page: 715 issue: 3 year: 1996 end-page: 720 ident: CR8 article-title: Transthoracic needle biopsy with a coaxially placed 20-gauge automated cutting needle: results in 122 patients publication-title: Radiology doi: 10.1148/radiology.198.3.8628859 – volume: 23 start-page: 712 issue: 3 year: 2013 end-page: 719 ident: CR21 article-title: Percutaneous transthoracic needle biopsy of small (≤ 1 cm) lung nodules under C-arm cone-beam CT virtual navigation guidance publication-title: Eur Radiol doi: 10.1007/s00330-012-2644-6 – volume: 38 start-page: 267 issue: 2 year: 2000 end-page: 279 ident: CR23 article-title: Special techniques in transthoracic needle biopsy of pulmonary nodules publication-title: Radiol Clin North Am doi: 10.1016/S0033-8389(05)70162-7 – volume: 58 start-page: 920 issue: 11 year: 2003 end-page: 936 ident: CR20 article-title: Guidelines for radiologically guided lung biopsy publication-title: Thorax doi: 10.1136/thorax.58.11.920 – volume: 169 start-page: 593 issue: 3 year: 1988 end-page: 601 ident: CR2 article-title: Percutaneous transthoracic needle biopsy publication-title: Radiology doi: 10.1148/radiology.169.3.3055026 – volume: 92 start-page: 939 issue: 7 year: 2009 end-page: 946 ident: CR17 article-title: Adequacy and complications of CT-guided percutaneous biopsy: a study of 334 cases in Srinagarind hospital publication-title: J Med Assoc Thai – volume: 47 start-page: 451 issue: 3 year: 2006 end-page: 469 ident: CR5 article-title: PET evaluation of lung cancer publication-title: J Nucl Med – volume: 198 start-page: 371 issue: 2 year: 1996 end-page: 375 ident: CR13 article-title: Risk of pneumothorax in CT-guided transthoracic needle aspiration biopsy of the lung publication-title: Radiology doi: 10.1148/radiology.198.2.8596834 – volume: 103 start-page: 449 issue: 3 year: 2009 end-page: 455 ident: CR18 article-title: Risk assessment of pneumothorax and pulmonary haemorrhage complicating percutaneous co-axial cutting needle lung biopsy publication-title: Respir Med doi: 10.1016/j.rmed.2008.09.010 – volume: 15 start-page: 479 issue: 5 year: 2004 end-page: 483 ident: CR10 article-title: Factors associated with pneumothorax and pneumothorax requiring treatment after percutaneous lung biopsy in 443 consecutive patients publication-title: J Vasc Interv Radiol doi: 10.1097/01.RVI.0000124951.24134.50 – volume: 109 start-page: 616 issue: 3 year: 1996 end-page: 620 ident: CR16 article-title: Transthoracic needle aspiration in patients with severe emphysema: a study of lung transplant candidates publication-title: Chest doi: 10.1378/chest.109.3.616 – volume: 271 start-page: 291 issue: 1 year: 2014 end-page: 300 ident: CR22 article-title: C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients publication-title: Radiology doi: 10.1148/radiol.13131265 – volume: 61 start-page: 69 issue: 2 year: 2011 end-page: 90 ident: CR1 article-title: Global cancer statistics publication-title: CA Cancer J Clin doi: 10.3322/caac.20107 – volume: 49 start-page: 991 issue: 9 year: 2008 end-page: 994 ident: CR4 article-title: Computed tomography- guided core-needle biopsy specimens show epidermal growth factor receptor mutations in patients with non-small-cell lung cancer publication-title: Acta Radiol doi: 10.1080/02841850802294410 – volume: 32 start-page: 254 issue: 5 year: 2009 end-page: 258 ident: CR7 article-title: CT-guided percutaneous core needle biopsy in oncology outpatients: sensitivity, specificity, complications publication-title: Onkologie doi: 10.1159/000209966 – volume: 121 start-page: 1521 issue: 5 year: 2002 end-page: 1526 ident: CR11 article-title: The incidence and the risk of pneumothorax and chesttube placement after percutaneous CT-guided lung biopsy: the angle of the needle trajectory is a novel predictor publication-title: Chest doi: 10.1378/chest.121.5.1521 – volume: 14 start-page: 581 issue: 5 year: 2003 end-page: 588 ident: CR12 article-title: Factors affecting diagnostic accuracy of CT-guided coaxial cutting needle lung biopsy: retrospective analysis of 631 procedures publication-title: J Vasc Interv Radiol doi: 10.1097/01.RVI.0000071087.76348.C7 – volume: 212 start-page: 165 issue: 1 year: 1999 end-page: 168 ident: CR14 article-title: Transthoracic needle aspiration biopsy: variables that affect risk of pneumothorax publication-title: Radiology doi: 10.1148/radiology.212.1.r99jl33165 – volume: 38 start-page: 267 issue: 2 year: 2000 ident: 1424_CR23 publication-title: Radiol Clin North Am doi: 10.1016/S0033-8389(05)70162-7 – volume: 61 start-page: 69 issue: 2 year: 2011 ident: 1424_CR1 publication-title: CA Cancer J Clin doi: 10.3322/caac.20107 – volume: 169 start-page: 593 issue: 3 year: 1988 ident: 1424_CR2 publication-title: Radiology doi: 10.1148/radiology.169.3.3055026 – volume: 304 start-page: 1497 issue: 5676 year: 2004 ident: 1424_CR3 publication-title: Science doi: 10.1126/science.1099314 – volume: 172 start-page: 1049 issue: 4 year: 1999 ident: 1424_CR15 publication-title: Am J Roentgenol doi: 10.2214/ajr.172.4.10587145 – volume: 23 start-page: 712 issue: 3 year: 2013 ident: 1424_CR21 publication-title: Eur Radiol doi: 10.1007/s00330-012-2644-6 – volume: 198 start-page: 371 issue: 2 year: 1996 ident: 1424_CR13 publication-title: Radiology doi: 10.1148/radiology.198.2.8596834 – volume: 212 start-page: 165 issue: 1 year: 1999 ident: 1424_CR14 publication-title: Radiology doi: 10.1148/radiology.212.1.r99jl33165 – volume: 121 start-page: 1521 issue: 5 year: 2002 ident: 1424_CR11 publication-title: Chest doi: 10.1378/chest.121.5.1521 – volume: 126 start-page: 748 issue: 3 year: 2004 ident: 1424_CR9 publication-title: Chest doi: 10.1378/chest.126.3.748 – volume: 109 start-page: 616 issue: 3 year: 1996 ident: 1424_CR16 publication-title: Chest doi: 10.1378/chest.109.3.616 – volume: 47 start-page: 451 issue: 3 year: 2006 ident: 1424_CR5 publication-title: J Nucl Med – volume: 32 start-page: 254 issue: 5 year: 2009 ident: 1424_CR7 publication-title: Onkologie doi: 10.1159/000209966 – volume: 49 start-page: 991 issue: 9 year: 2008 ident: 1424_CR4 publication-title: Acta Radiol doi: 10.1080/02841850802294410 – volume: 271 start-page: 291 issue: 1 year: 2014 ident: 1424_CR22 publication-title: Radiology doi: 10.1148/radiol.13131265 – volume: 15 start-page: 479 issue: 5 year: 2004 ident: 1424_CR10 publication-title: J Vasc Interv Radiol doi: 10.1097/01.RVI.0000124951.24134.50 – volume: 103 start-page: 449 issue: 3 year: 2009 ident: 1424_CR18 publication-title: Respir Med doi: 10.1016/j.rmed.2008.09.010 – volume: 198 start-page: 715 issue: 3 year: 1996 ident: 1424_CR8 publication-title: Radiology doi: 10.1148/radiology.198.3.8628859 – volume: 55 start-page: 964 issue: 12 year: 2000 ident: 1424_CR6 publication-title: Clin Radiol doi: 10.1053/crad.2000.0964 – volume: 14 start-page: 581 issue: 5 year: 2003 ident: 1424_CR12 publication-title: J Vasc Interv Radiol doi: 10.1097/01.RVI.0000071087.76348.C7 – volume: 92 start-page: 939 issue: 7 year: 2009 ident: 1424_CR17 publication-title: J Med Assoc Thai – volume: 75 start-page: 731 issue: 897 year: 2002 ident: 1424_CR19 publication-title: Br J Radiol doi: 10.1259/bjr.75.897.750731 – volume: 58 start-page: 920 issue: 11 year: 2003 ident: 1424_CR20 publication-title: Thorax doi: 10.1136/thorax.58.11.920 – reference: 24475839 - Radiology. 2014 Apr;271(1):291-300 – reference: 10405737 - Radiology. 1999 Jul;212(1):165-8 – reference: 19420971 - Onkologie. 2009 May;32(5):254-8 – reference: 12761311 - J Vasc Interv Radiol. 2003 May;14 (5):581-8 – reference: 15126658 - J Vasc Interv Radiol. 2004 May;15(5):479-83 – reference: 10765389 - Radiol Clin North Am. 2000 Mar;38(2):267-79 – reference: 8617066 - Chest. 1996 Mar;109 (3):616-19 – reference: 12006438 - Chest. 2002 May;121(5):1521-6 – reference: 21296855 - CA Cancer J Clin. 2011 Mar-Apr;61(2):69-90 – reference: 18651255 - Acta Radiol. 2008 Nov;49(9):991-4 – reference: 22976917 - Eur Radiol. 2013 Mar;23 (3):712-9 – reference: 8596834 - Radiology. 1996 Feb;198(2):371-5 – reference: 19626814 - J Med Assoc Thai. 2009 Jul;92(7):939-46 – reference: 15364752 - Chest. 2004 Sep;126(3):748-54 – reference: 12200241 - Br J Radiol. 2002 Sep;75(897):731-5 – reference: 14586042 - Thorax. 2003 Nov;58(11):920-36 – reference: 11124077 - Clin Radiol. 2000 Dec;55(12 ):964-9 – reference: 8628859 - Radiology. 1996 Mar;198(3):715-20 – reference: 16513615 - J Nucl Med. 2006 Mar;47(3):451-69 – reference: 18977128 - Respir Med. 2009 Mar;103(3):449-55 – reference: 15118125 - Science. 2004 Jun 4;304(5676):1497-500 – reference: 3055026 - Radiology. 1988 Dec;169(3):593-601 – reference: 10587145 - AJR Am J Roentgenol. 1999 Apr;172(4):1049-53 |
SSID | ssj0057624 |
Score | 1.6448338 |
Snippet | The factors influencing the incidence of common complications(pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near... Summary The factors influencing the incidence of common complications (pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps... The factors influencing the incidence of common complications (pneumothorax and pulmonary hemorrhage) of CT-guided percutaneous needle biopsy of lumps near... |
SourceID | wanfang proquest pubmed crossref springer chongqing |
SourceType | Aggregation Database Index Database Enrichment Source Publisher |
StartPage | 278 |
SubjectTerms | Biopsy, Needle - adverse effects Biopsy, Needle - methods Female Humans Lung Neoplasms - pathology Male Medicine Medicine & Public Health Middle Aged Risk Factors Tomography, X-Ray Computed 保留时间 并发症 引导 活检 穿刺 肺出血 风险因素 |
Title | Risk Factors of Complications after CT-guided Percutaneous Needle Biopsy of Lumps Near Pulmonary Hilum |
URI | http://lib.cqvip.com/qk/85740A/201502/664376505.html https://link.springer.com/article/10.1007/s11596-015-1424-3 https://www.ncbi.nlm.nih.gov/pubmed/25877365 https://www.proquest.com/docview/1674203867 https://d.wanfangdata.com.cn/periodical/tjykdxxb-e201502021 |
Volume | 35 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
journalDatabaseRights | – providerCode: PRVAVX databaseName: SpringerLINK - Czech Republic Consortium customDbUrl: eissn: 1993-1352 dateEnd: 99991231 omitProxy: false ssIdentifier: ssj0057624 issn: 1672-0733 databaseCode: AGYKE dateStart: 19970101 isFulltext: true titleUrlDefault: http://link.springer.com providerName: Springer Nature – providerCode: PRVAVX databaseName: SpringerLink Journals (ICM) customDbUrl: eissn: 1993-1352 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0057624 issn: 1672-0733 databaseCode: U2A dateStart: 20020101 isFulltext: true titleUrlDefault: http://www.springerlink.com/journals/ providerName: Springer Nature |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1ba9swFD6sKYy97H7JuhUN-rTh4tiWZD-G0q5sbA8jge5J2LqkaYLtxTY0-_U7iqWk3Uahr0Y6si7nnE86N4CjTNGY2eclw3IZ2NDLIKOSBiOJ6gcZM6Jq423xnZ1Pky8X9MLFcTfe292bJDeSehfshprX3n6RUBIlQbwH-9TeTwawP_788-upF8CIoPtatjhSYGsSemPm_4jYlAqXVTn7hQPeVk3_4M0bttJNhE9p8nJ2QxmdPYGJn0bvg7I47triWP7-K8PjPef5FB47cErG_Wl6Bg90-RwefnPm9xdgfsybBXElekhlyC2HdLKpN05OJsGsmyutSK1XskPwqauuISWqyaUmxbyqm7Xti1Kxtp_zFam7JXJDvlqTyzl-fgnTs9PJyXngCjUEEu-DbcC4MYnJeYHgzZg05AU3mprRiEWRVFlaZDZcl-eMci3DWIYm1cpwWYQ8s2bP-BUMyqrUb4BwpSiCUG0kx5urSnMtVUJlrpmiaSHzIRxs90vUfUIOwaz1EaEmHULod1BIl-PcltpYil12Zru6AldX2NUV8RA-brt4enc0_uCPhUA2tLaVfhGFDeaIwjhlfAiv-_OyJRfRlPOY4d998jsunKRo7hrryJ2xXeP2ar1Q19eF0JF9qYoQoL29F9EDeGR79q5H72DQrjr9HlFVWxw6LjqEvWk0_gNvixeP |
linkProvider | Springer Nature |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1bb9MwFD6CTgJeGLdBGQMj7QmUKU1iO3mcpm2FXR5QJ40nK_GlK62S0CTSyq_fcRO3G6BJe43s4_hyzvnscwPYTRQNmX1eMiyVng299BIqqTeQqH6QMQOqlt4W52x4EX2_pJddHHflvN2dSXIpqdfBbqh57e0XCUVB5IWPYSMaxHHUg439458nh04AI4Jua9niSJ6tSeiMmf8jYlMqXBX5-DcOeFc1_YM3b9lKlxE-uUnz8S1ldLQJIzeN1gdlutfU2Z7881eGxwfO8wU878Ap2W9P00t4pPNX8OSsM7-_BvNjUk1JV6KHFIbccUgny3rj5GDkjZuJ0oqUei4bBJ-6aCqSo5qcaZJNirJa2L4oFUv7OZ2TspkhN6TzBbma4Oc3cHF0ODoYel2hBk_ifbD2GDcmMinPELwZE_s840ZTMxiwIJAqibPEhuvylFGupR9K38RaGS4znyfW7BluQS8vcv0OCFeKIgjVRnK8uao41VJFVKaaKRpnMu3D9mq_RNkm5BDMWh8RatI--G4HhexynNtSGzOxzs5sV1fg6gq7uiLsw5dVF0fvnsaf3bEQyIbWttIuorDBHIEfxoz34W17XlbkAhpzHjL8u69ux0UnKar7xtrtzti6cf1rMVXX15nQgX2pChCgvX8Q0U_wdDg6OxWn385PtuGZpdK6IX2AXj1v9A4irDr72HHUDSxNGZc |
linkToPdf | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwlV1Za9wwEBZtCqEvJb036aFCnlpEvLIl2Y8h7ZJeoZQs5E3IOjbbLLa7tiH77zuztncTWgJ9NdLIaEaabzQXIYeZE7HE56UgjWWYeskyYQUbW1A_cDC5cOtoizN5Ok2-XIiLvs9pPUS7Dy7JLqcBqzQVzVHlwtE28Q20MFrCQDThCYvvkwcJqGq0vqb8eLiKAUt3XW1hTYbdCQe35r9IYHGFy7KY_Yalbyupv5DnDa_pOtenCKaY3VBLkz3yqMeT9LgTgMfkni-ekN3vvcf8KQk_5_UV7bvq0DLQWzHkdN0inJ6cs1k7d97Ryi9tC3jRl21NC9BsC0_zeVnVK5wLF1mFn82SVu0CBNgsV_RyDp-fkenk0_nJKet7KzALJlzDpAohCUblgLdCSCOVq-BFGI8l59ZlaZ5hhq0yUihvo9hGIfUuKJtHKkNPZfyc7BRl4V8SqpwTgBt9sAqMTZcab10irPHSiTS3ZkQONhurq66GhpboMAR0KEYkGrZa274sOXbHWOhtQWXklAZOaeSUjkfk_WbKQO-Owe8G_mk4OegO6TZRY_4Fj-JUqhF50TF2Q46LVKlYwt99GDit-8Nd37XWYS8M28HNr9WVu77Otef4uMQBU-3_F9G3ZPfHx4n-9vns6wF5iES6wKFXZKdZtv41YKImf7OW-z8ecwES |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Risk+factors+of+complications+after+CT-guided+percutaneous+needle+biopsy+of+lumps+near+pulmonary+hilum&rft.jtitle=Journal+of+Huazhong+University+of+Science+and+Technology.+Medical+sciences&rft.au=Yin%2C+Zhong-Yuan&rft.au=Lin%2C+Zhen-Yu&rft.au=Wang%2C+Ye&rft.au=Li%2C+Peng-Cheng&rft.date=2015-04-01&rft.issn=1672-0733&rft.volume=35&rft.issue=2&rft.spage=278&rft_id=info:doi/10.1007%2Fs11596-015-1424-3&rft.externalDBID=NO_FULL_TEXT |
thumbnail_s | http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fimage.cqvip.com%2Fvip1000%2Fqk%2F85740A%2F85740A.jpg http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fwww.wanfangdata.com.cn%2Fimages%2FPeriodicalImages%2Ftjykdxxb-e%2Ftjykdxxb-e.jpg |