Assessment of high-frequency steady-state visual evoked potentials from below-the-hairline areas for a brain-computer interface based on Depth-of-Field

•Distinguishable high-frequency SSVEP was elicited from hairless areas using a Depth-of-Field setup.•SSVEP measured from below-the-hairline areas could be modulated by eye focusing mechanism.•BCI proposed achieved effective communication with binary choice.•BCI proposed uses comfortable stimuli (hig...

Full description

Saved in:
Bibliographic Details
Published inComputer methods and programs in biomedicine Vol. 184; p. 105271
Main Authors Floriano, Alan, Delisle-Rodriguez, Denis, Diez, Pablo F., Bastos-Filho, Teodiano Freire
Format Journal Article
LanguageEnglish
Published Ireland Elsevier B.V 01.02.2020
Subjects
Online AccessGet full text
ISSN0169-2607
1872-7565
1872-7565
DOI10.1016/j.cmpb.2019.105271

Cover

More Information
Summary:•Distinguishable high-frequency SSVEP was elicited from hairless areas using a Depth-of-Field setup.•SSVEP measured from below-the-hairline areas could be modulated by eye focusing mechanism.•BCI proposed achieved effective communication with binary choice.•BCI proposed uses comfortable stimuli (high-frequency range), practical electrodes placement and does not require a calibration phase by users. Recently, a promising Brain-Computer Interface based on Steady-State Visual Evoked Potential (SSVEP-BCI) was proposed, which composed of two stimuli presented together in the center of the subject’s field of view, but at different depth planes (Depth-of-Field setup). Thus, users were easily able to select one of them by shifting their eye focus. However, in that work, EEG signals were collected through electrodes placed on occipital and parietal regions (hair-covered areas), which demanded a long preparation time. Also, that work used low-frequency stimuli, which can produce visual fatigue and increase the risk of photosensitive epileptic seizures. In order to improve the practicality and visual comfort, this work proposes a BCI based on Depth-of-Field using the high-frequency SSVEP response measured from below-the-hairline areas (behind-the-ears). Two high-frequency stimuli (31 Hz and 32 Hz) were used in a Depth-of-Field setup to study the SSVEP response from behind-the-ears (TP9 and TP10). Multivariate Spectral F-test (MSFT) method was used to verify the elicited response. Afterwards, a BCI was proposed to command a mobile robot in a virtual reality environment. The commands were recognized through Temporally Local Multivariate Synchronization Index (TMSI) method. The data analysis reveal that the focused stimuli elicit distinguishable SSVEP response when measured from hairless areas, in spite of the fact that the non-focused stimulus is also present in the field of view. Also, our BCI shows a satisfactory result, reaching average accuracy of 91.6% and Information Transfer Rate (ITR) of 5.3 bits/min. These findings contribute to the development of more safe and practical BCI.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0169-2607
1872-7565
1872-7565
DOI:10.1016/j.cmpb.2019.105271