Improving ungated steady‐state cardiac perfusion using transition bands

Purpose Although gated first‐pass contrast‐enhanced sequences are the clinical standard for cardiovascular MR perfusion, some patient conditions necessitate using ungated steady‐state sequences. However, through‐plane cardiac motion and blood flow into the left ventricle can disrupt the magnetizatio...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 94; no. 1; pp. 199 - 214
Main Authors Mendes, Jason K., Le, Johnathan V., Arai, Andrew E., Ranjan, Ravi, DiBella, Edward V. R., Adluru, Ganesh
Format Journal Article
LanguageEnglish
Published United States Wiley Subscription Services, Inc 01.07.2025
John Wiley and Sons Inc
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.30467

Cover

More Information
Summary:Purpose Although gated first‐pass contrast‐enhanced sequences are the clinical standard for cardiovascular MR perfusion, some patient conditions necessitate using ungated steady‐state sequences. However, through‐plane cardiac motion and blood flow into the left ventricle can disrupt the magnetization steady state of the tissue, and perfusion quantification based on a steady‐state assumption will contain errors. The tissue magnetization steady‐state disruption can be eliminated with a proposed sequence modification that simultaneously excites transition bands with no change in the sequence resolution or timing parameters. Theory and Methods The proposed sequence modification simultaneously excites two transition bands adjacent to the imaged region. The transition bands experience the same consistent excitation history as the imaged slices. Thus, any tissue that moves into an imaged slice location from a transition band location will not disrupt the magnetization steady state. Gradient dephasing and radiofrequency spoiling are used to null the transition band signal so that it does not contribute to the reconstructed images. Transition bands were added to a two‐dimensional ungated steady‐state radial FLASH (fast low‐angle shot) sequence with simultaneous multiband imaging on a PRISMA 3T MRI scanner. Phantom, normal canine, and human subject data are presented. Results Transition bands reduce the amount of tissue magnetization disruption to the steady state without adding artifacts to the imaged slices. Myocardial blood flow maps from a selected normal canine study and a normal human subject show good uniformity and consistency to literature values for all slices. Perfusion estimates with the proposed method also demonstrate good consistency with saturation‐recovery methods commonly used for myocardial perfusion imaging. Conclusion We have demonstrated that the proposed transition bands can reduce quantification errors resulting from blood flow into the left ventricle and through‐plane cardiac and respiratory motion. There is no loss of image‐acquisition efficiency, and temporal resolution is unchanged with this technique.
Bibliography:Ganesh Adluru and Edward DiBella equally share the role of senior author.
Jason Mendes and Johnathan Le contributed equally to this work.
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.30467