Quantitative analysis of MRI signal abnormalities of brain white matter with high reproducibility and accuracy

Purpose To assess the reproducibility and accuracy compared to radiologists of three automated segmentation pipelines for quantitative magnetic resonance imaging (MRI) measurement of brain white matter signal abnormalities (WMSA). Materials and Methods WMSA segmentation was performed on pairs of who...

Full description

Saved in:
Bibliographic Details
Published inJournal of magnetic resonance imaging Vol. 15; no. 2; pp. 203 - 209
Main Authors Wei, Xingchang, Warfield, Simon K., Zou, Kelly H., Wu, Ying, Li, Xiaoming, Guimond, Alexandre, Mugler III, John P., Benson, Randall R., Wolfson, Leslie, Weiner, Howard L., Guttmann, Charles R.G.
Format Journal Article
LanguageEnglish
Published New York Wiley Subscription Services, Inc., A Wiley Company 01.02.2002
Subjects
Online AccessGet full text
ISSN1053-1807
1522-2586
1522-2586
DOI10.1002/jmri.10053

Cover

More Information
Summary:Purpose To assess the reproducibility and accuracy compared to radiologists of three automated segmentation pipelines for quantitative magnetic resonance imaging (MRI) measurement of brain white matter signal abnormalities (WMSA). Materials and Methods WMSA segmentation was performed on pairs of whole brain scans from 20 patients with multiple sclerosis (MS) and 10 older subjects who were positioned and imaged twice within 30 minutes. Radiologist outlines of WMSA on 20 sections from 16 patients were compared with the corresponding results of each segmentation method. Results The segmentation method combining expectation‐maximization (EM) tissue segmentation, template‐driven segmentation (TDS), and partial volume effect correction (PVEC) demonstrated the highest accuracy (the absolute value of the Z‐score was 0.99 for both groups of subjects), as well as high interscan reproducibility (repeatability coefficient was 0.68 mL in MS patients and 1.49 mL in aging subjects). Conclusion The addition of TDS to the EM segmentation and PVEC algorithms significantly improved the accuracy of WMSA volume measurements, while also improving measurement reproducibility. J. Magn. Reson. Imaging 2002;15:203–209. © 2002 Wiley‐Liss, Inc.
Bibliography:ark:/67375/WNG-4R1LWVBX-Q
ArticleID:JMRI10053
istex:F963CC62D296B6ABDC68103262740F6EEC672406
National Institutes of Health - No. P41 RR13218-01
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ObjectType-Undefined-3
ISSN:1053-1807
1522-2586
1522-2586
DOI:10.1002/jmri.10053