Fast design of local N-gram-specific absorption rate-optimized radiofrequency pulses for parallel transmit systems

Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under c...

Full description

Saved in:
Bibliographic Details
Published inMagnetic resonance in medicine Vol. 67; no. 3; pp. 824 - 834
Main Authors Sbrizzi, Alessandro, Hoogduin, Hans, Lagendijk, Jan J., Luijten, Peter, Sleijpen, Gerard L. G., van den Berg, Cornelis A. T.
Format Journal Article
LanguageEnglish
Published Hoboken Wiley Subscription Services, Inc., A Wiley Company 01.03.2012
Subjects
Online AccessGet full text
ISSN0740-3194
1522-2594
1522-2594
DOI10.1002/mrm.23049

Cover

More Information
Summary:Designing multidimensional radiofrequency pulses for clinical application must take into account the local specific absorption rate (SAR) as controlling the global SAR does not guarantee suppression of hot spots. The maximum peak SAR, averaged over an N grams cube (local NgSAR), must be kept under certain safety limits. Computing the SAR over a three‐dimensional domain can require several minutes and implementing this computation in a radiofrequency pulse design algorithm could slow down prohibitively the numerical process. In this article, a fast optimization algorithm is designed acting on a limited number of control points, which are strategically selected locations from the entire domain. The selection is performed by comparing the largest eigenvalues and the corresponding eigenvectors of the matrices which locally describe the tissue's amount of heating. The computation complexity is dramatically reduced. An additional critical step to accelerate the computations is to apply a multi shift conjugate gradient algorithm. Two transmit array setups are studied: a two channel 3 T birdcage body coil and a 12‐channel 7 T transverse electromagnetic (TEM) head coil. In comparison with minimum power radiofrequency pulses, it is shown that a reduction of 36.5% and 35%, respectively, in the local NgSAR can be achieved within short, clinically feasible, computation times. Magn Reson Med, 2012. © 2011 Wiley Periodicals, Inc.
Bibliography:ark:/67375/WNG-2P4HCS09-C
ArticleID:MRM23049
istex:FF1F8E1DDF66757CF70A9F9BF2023720DAA5B5D1
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:0740-3194
1522-2594
1522-2594
DOI:10.1002/mrm.23049