Synthesizing 4D Magnetic Resonance Angiography From 3D Time-of-Flight Using Deep Learning: A Feasibility Study

Objective and background This study aimed to develop a deep convolutional neural network (DCNN) model capable of generating synthetic 4D magnetic resonance angiography (MRA) from 3D time-of-flight (TOF) images, allowing estimation of temporal changes in arterial flow. TOF MRA provides static informa...

Full description

Saved in:
Bibliographic Details
Published inCureus Vol. 16; no. 5; p. e60803
Main Authors Wada, Akihiko, Akatsu, Toshiya, Ikenouchi, Yutaka, Suzuki, Michimasa, Akashi, Toshiaki, Hagiwara, Akifumi, Nishizawa, Mitsuo, Sano, Katsuhiro, Kamagata, Koji, Aoki, Shigeki
Format Journal Article
LanguageEnglish
Published United States Springer Science and Business Media LLC 21.05.2024
Springer Nature B.V
Cureus
Subjects
Online AccessGet full text
ISSN2168-8184
2168-8184
DOI10.7759/cureus.60803

Cover

Abstract Objective and background This study aimed to develop a deep convolutional neural network (DCNN) model capable of generating synthetic 4D magnetic resonance angiography (MRA) from 3D time-of-flight (TOF) images, allowing estimation of temporal changes in arterial flow. TOF MRA provides static information about arterial structures through maximum intensity projection (MIP) processing, but it does not capture the dynamic information of contrast agent circulation, which is lost during MIP processing. Considering the principles of TOF, it is hypothesized that dynamic information about arterial blood flow is latent within TOF signals. Although arterial spin labeling (ASL) can extract dynamic arterial information, ASL MRA has drawbacks, such as longer imaging times and lower spatial resolution than TOF MRA. This study's primary aim is to extend the utility of TOF MRA by training a machine-learning model on paired TOF and ASL data to extract latent dynamic information from TOF signals. Methods A DCNN combining a modified U-Net and a long-short-term memory (LSTM) network was trained on a dataset of 13 subjects (11 men and two women, aged 42-77 years) using paired 3D TOF MRA and 4D ASL MRA images. Subjects had no history of cerebral vessel occlusion or significant stenosis. The dataset was acquired using a 3T MRI system with a 32-channel head coil. Preprocessing involved resampling and intensity normalization of TOF and ASL images, followed by data augmentation and arterial mask generation. The model learned to extract flow information from TOF images and generate 8-phase 4D MRA images. The precision of flow estimation was evaluated using the coefficient of determination (R²) and Bland-Altman analysis. A board-certified neuroradiologist validated the quality of the images and the absence of significant stenosis in the major cerebral arteries. Results The generated 4D MRA images closely resembled the ground-truth ASL MRA data, with R² values of 0.92, 0.85, and 0.84 for the internal carotid artery (ICA), proximal middle cerebral artery (MCA), and distal MCA, respectively. Bland-Altman analysis revealed a systematic error of -0.06, with 95% agreement limits ranging from -0.18 to 0.12. Additionally, the model successfully identified flow abnormalities in a subject with left MCA stenosis, displaying a delayed peak and subsequent flattening distal to the stenosis, indicative of reduced blood flow. Visualization of the predicted arterial flow overlaid on the original TOF MRA images highlighted the spatial progression and dynamics of the flow. Conclusions The DCNN model effectively generated synthetic 4D MRA images from TOF images, demonstrating its potential to estimate temporal changes in arterial flow accurately. This non-invasive technique offers a promising alternative to conventional methods for visualizing and evaluating healthy and pathological flow dynamics. It has significant potential to improve the diagnosis and treatment of cerebrovascular diseases by providing detailed temporal flow information without the need for contrast agents or invasive procedures. The practical implementation of this model could enable the extraction of dynamic cerebral blood flow information from routine brain MRI examinations, contributing to the early diagnosis and management of cerebrovascular disorders.
AbstractList Objective and backgroundThis study aimed to develop a deep convolutional neural network (DCNN) model capable of generating synthetic 4D magnetic resonance angiography (MRA) from 3D time-of-flight (TOF) images, allowing estimation of temporal changes in arterial flow. TOF MRA provides static information about arterial structures through maximum intensity projection (MIP) processing, but it does not capture the dynamic information of contrast agent circulation, which is lost during MIP processing. Considering the principles of TOF, it is hypothesized that dynamic information about arterial blood flow is latent within TOF signals. Although arterial spin labeling (ASL) can extract dynamic arterial information, ASL MRA has drawbacks, such as longer imaging times and lower spatial resolution than TOF MRA. This study's primary aim is to extend the utility of TOF MRA by training a machine-learning model on paired TOF and ASL data to extract latent dynamic information from TOF signals.MethodsA DCNN combining a modified U-Net and a long-short-term memory (LSTM) network was trained on a dataset of 13 subjects (11 men and two women, aged 42-77 years) using paired 3D TOF MRA and 4D ASL MRA images. Subjects had no history of cerebral vessel occlusion or significant stenosis. The dataset was acquired using a 3T MRI system with a 32-channel head coil. Preprocessing involved resampling and intensity normalization of TOF and ASL images, followed by data augmentation and arterial mask generation. The model learned to extract flow information from TOF images and generate 8-phase 4D MRA images. The precision of flow estimation was evaluated using the coefficient of determination (R²) and Bland-Altman analysis. A board-certified neuroradiologist validated the quality of the images and the absence of significant stenosis in the major cerebral arteries.ResultsThe generated 4D MRA images closely resembled the ground-truth ASL MRA data, with R² values of 0.92, 0.85, and 0.84 for the internal carotid artery (ICA), proximal middle cerebral artery (MCA), and distal MCA, respectively. Bland-Altman analysis revealed a systematic error of -0.06, with 95% agreement limits ranging from -0.18 to 0.12. Additionally, the model successfully identified flow abnormalities in a subject with left MCA stenosis, displaying a delayed peak and subsequent flattening distal to the stenosis, indicative of reduced blood flow. Visualization of the predicted arterial flow overlaid on the original TOF MRA images highlighted the spatial progression and dynamics of the flow.ConclusionsThe DCNN model effectively generated synthetic 4D MRA images from TOF images, demonstrating its potential to estimate temporal changes in arterial flow accurately. This non-invasive technique offers a promising alternative to conventional methods for visualizing and evaluating healthy and pathological flow dynamics. It has significant potential to improve the diagnosis and treatment of cerebrovascular diseases by providing detailed temporal flow information without the need for contrast agents or invasive procedures. The practical implementation of this model could enable the extraction of dynamic cerebral blood flow information from routine brain MRI examinations, contributing to the early diagnosis and management of cerebrovascular disorders.
Objective and background This study aimed to develop a deep convolutional neural network (DCNN) model capable of generating synthetic 4D magnetic resonance angiography (MRA) from 3D time-of-flight (TOF) images, allowing estimation of temporal changes in arterial flow. TOF MRA provides static information about arterial structures through maximum intensity projection (MIP) processing, but it does not capture the dynamic information of contrast agent circulation, which is lost during MIP processing. Considering the principles of TOF, it is hypothesized that dynamic information about arterial blood flow is latent within TOF signals. Although arterial spin labeling (ASL) can extract dynamic arterial information, ASL MRA has drawbacks, such as longer imaging times and lower spatial resolution than TOF MRA. This study's primary aim is to extend the utility of TOF MRA by training a machine-learning model on paired TOF and ASL data to extract latent dynamic information from TOF signals. Methods A DCNN combining a modified U-Net and a long-short-term memory (LSTM) network was trained on a dataset of 13 subjects (11 men and two women, aged 42-77 years) using paired 3D TOF MRA and 4D ASL MRA images. Subjects had no history of cerebral vessel occlusion or significant stenosis. The dataset was acquired using a 3T MRI system with a 32-channel head coil. Preprocessing involved resampling and intensity normalization of TOF and ASL images, followed by data augmentation and arterial mask generation. The model learned to extract flow information from TOF images and generate 8-phase 4D MRA images. The precision of flow estimation was evaluated using the coefficient of determination (R²) and Bland-Altman analysis. A board-certified neuroradiologist validated the quality of the images and the absence of significant stenosis in the major cerebral arteries. Results The generated 4D MRA images closely resembled the ground-truth ASL MRA data, with R² values of 0.92, 0.85, and 0.84 for the internal carotid artery (ICA), proximal middle cerebral artery (MCA), and distal MCA, respectively. Bland-Altman analysis revealed a systematic error of -0.06, with 95% agreement limits ranging from -0.18 to 0.12. Additionally, the model successfully identified flow abnormalities in a subject with left MCA stenosis, displaying a delayed peak and subsequent flattening distal to the stenosis, indicative of reduced blood flow. Visualization of the predicted arterial flow overlaid on the original TOF MRA images highlighted the spatial progression and dynamics of the flow. Conclusions The DCNN model effectively generated synthetic 4D MRA images from TOF images, demonstrating its potential to estimate temporal changes in arterial flow accurately. This non-invasive technique offers a promising alternative to conventional methods for visualizing and evaluating healthy and pathological flow dynamics. It has significant potential to improve the diagnosis and treatment of cerebrovascular diseases by providing detailed temporal flow information without the need for contrast agents or invasive procedures. The practical implementation of this model could enable the extraction of dynamic cerebral blood flow information from routine brain MRI examinations, contributing to the early diagnosis and management of cerebrovascular disorders.
Objective and background This study aimed to develop a deep convolutional neural network (DCNN) model capable of generating synthetic 4D magnetic resonance angiography (MRA) from 3D time-of-flight (TOF) images, allowing estimation of temporal changes in arterial flow. TOF MRA provides static information about arterial structures through maximum intensity projection (MIP) processing, but it does not capture the dynamic information of contrast agent circulation, which is lost during MIP processing. Considering the principles of TOF, it is hypothesized that dynamic information about arterial blood flow is latent within TOF signals. Although arterial spin labeling (ASL) can extract dynamic arterial information, ASL MRA has drawbacks, such as longer imaging times and lower spatial resolution than TOF MRA. This study's primary aim is to extend the utility of TOF MRA by training a machine-learning model on paired TOF and ASL data to extract latent dynamic information from TOF signals. Methods A DCNN combining a modified U-Net and a long-short-term memory (LSTM) network was trained on a dataset of 13 subjects (11 men and two women, aged 42-77 years) using paired 3D TOF MRA and 4D ASL MRA images. Subjects had no history of cerebral vessel occlusion or significant stenosis. The dataset was acquired using a 3T MRI system with a 32-channel head coil. Preprocessing involved resampling and intensity normalization of TOF and ASL images, followed by data augmentation and arterial mask generation. The model learned to extract flow information from TOF images and generate 8-phase 4D MRA images. The precision of flow estimation was evaluated using the coefficient of determination (R²) and Bland-Altman analysis. A board-certified neuroradiologist validated the quality of the images and the absence of significant stenosis in the major cerebral arteries. Results The generated 4D MRA images closely resembled the ground-truth ASL MRA data, with R² values of 0.92, 0.85, and 0.84 for the internal carotid artery (ICA), proximal middle cerebral artery (MCA), and distal MCA, respectively. Bland-Altman analysis revealed a systematic error of -0.06, with 95% agreement limits ranging from -0.18 to 0.12. Additionally, the model successfully identified flow abnormalities in a subject with left MCA stenosis, displaying a delayed peak and subsequent flattening distal to the stenosis, indicative of reduced blood flow. Visualization of the predicted arterial flow overlaid on the original TOF MRA images highlighted the spatial progression and dynamics of the flow. Conclusions The DCNN model effectively generated synthetic 4D MRA images from TOF images, demonstrating its potential to estimate temporal changes in arterial flow accurately. This non-invasive technique offers a promising alternative to conventional methods for visualizing and evaluating healthy and pathological flow dynamics. It has significant potential to improve the diagnosis and treatment of cerebrovascular diseases by providing detailed temporal flow information without the need for contrast agents or invasive procedures. The practical implementation of this model could enable the extraction of dynamic cerebral blood flow information from routine brain MRI examinations, contributing to the early diagnosis and management of cerebrovascular disorders.Objective and background This study aimed to develop a deep convolutional neural network (DCNN) model capable of generating synthetic 4D magnetic resonance angiography (MRA) from 3D time-of-flight (TOF) images, allowing estimation of temporal changes in arterial flow. TOF MRA provides static information about arterial structures through maximum intensity projection (MIP) processing, but it does not capture the dynamic information of contrast agent circulation, which is lost during MIP processing. Considering the principles of TOF, it is hypothesized that dynamic information about arterial blood flow is latent within TOF signals. Although arterial spin labeling (ASL) can extract dynamic arterial information, ASL MRA has drawbacks, such as longer imaging times and lower spatial resolution than TOF MRA. This study's primary aim is to extend the utility of TOF MRA by training a machine-learning model on paired TOF and ASL data to extract latent dynamic information from TOF signals. Methods A DCNN combining a modified U-Net and a long-short-term memory (LSTM) network was trained on a dataset of 13 subjects (11 men and two women, aged 42-77 years) using paired 3D TOF MRA and 4D ASL MRA images. Subjects had no history of cerebral vessel occlusion or significant stenosis. The dataset was acquired using a 3T MRI system with a 32-channel head coil. Preprocessing involved resampling and intensity normalization of TOF and ASL images, followed by data augmentation and arterial mask generation. The model learned to extract flow information from TOF images and generate 8-phase 4D MRA images. The precision of flow estimation was evaluated using the coefficient of determination (R²) and Bland-Altman analysis. A board-certified neuroradiologist validated the quality of the images and the absence of significant stenosis in the major cerebral arteries. Results The generated 4D MRA images closely resembled the ground-truth ASL MRA data, with R² values of 0.92, 0.85, and 0.84 for the internal carotid artery (ICA), proximal middle cerebral artery (MCA), and distal MCA, respectively. Bland-Altman analysis revealed a systematic error of -0.06, with 95% agreement limits ranging from -0.18 to 0.12. Additionally, the model successfully identified flow abnormalities in a subject with left MCA stenosis, displaying a delayed peak and subsequent flattening distal to the stenosis, indicative of reduced blood flow. Visualization of the predicted arterial flow overlaid on the original TOF MRA images highlighted the spatial progression and dynamics of the flow. Conclusions The DCNN model effectively generated synthetic 4D MRA images from TOF images, demonstrating its potential to estimate temporal changes in arterial flow accurately. This non-invasive technique offers a promising alternative to conventional methods for visualizing and evaluating healthy and pathological flow dynamics. It has significant potential to improve the diagnosis and treatment of cerebrovascular diseases by providing detailed temporal flow information without the need for contrast agents or invasive procedures. The practical implementation of this model could enable the extraction of dynamic cerebral blood flow information from routine brain MRI examinations, contributing to the early diagnosis and management of cerebrovascular disorders.
Author Akatsu, Toshiya
Wada, Akihiko
Sano, Katsuhiro
Hagiwara, Akifumi
Ikenouchi, Yutaka
Nishizawa, Mitsuo
Kamagata, Koji
Suzuki, Michimasa
Akashi, Toshiaki
Aoki, Shigeki
AuthorAffiliation 1 Department of Radiology, Juntendo University School of Medicine, Tokyo, JPN
3 Department of Radiology, Juntendo University Urayasu Hospital, Chiba, JPN
2 Department of Radiology, Juntendo University Hospital, Tokyo, JPN
AuthorAffiliation_xml – name: 3 Department of Radiology, Juntendo University Urayasu Hospital, Chiba, JPN
– name: 1 Department of Radiology, Juntendo University School of Medicine, Tokyo, JPN
– name: 2 Department of Radiology, Juntendo University Hospital, Tokyo, JPN
Author_xml – sequence: 1
  fullname: Wada, Akihiko
– sequence: 2
  fullname: Akatsu, Toshiya
– sequence: 3
  fullname: Ikenouchi, Yutaka
– sequence: 4
  fullname: Suzuki, Michimasa
– sequence: 5
  fullname: Akashi, Toshiaki
– sequence: 6
  fullname: Hagiwara, Akifumi
– sequence: 7
  fullname: Nishizawa, Mitsuo
– sequence: 8
  fullname: Sano, Katsuhiro
– sequence: 9
  fullname: Kamagata, Koji
– sequence: 10
  fullname: Aoki, Shigeki
BackLink https://cir.nii.ac.jp/crid/1871147691543297152$$DView record in CiNii
https://www.ncbi.nlm.nih.gov/pubmed/38910733$$D View this record in MEDLINE/PubMed
BookMark eNqFkUFv1DAQhS1UREvpjTOyBAcOpNhx4sRc0KrLAtIiJNqeLduZZI2ydmonoPDr8TYFChdkyfbI38y8eX6Mjpx3gNBTSs6rqhSvzRRgiuec1IQ9QCc55XVW07o4unc_RmcxWk0KzmkpyuoROma1oKRi7AS5y9mNO4j2h3UdLtb4k-ocjNbgLxC9U84AXrnO-i6oYTfjTfB7zNb4yu4h82226W23G_F1PKSvAQa8BRVcit7gFd6ASp1tb8cZX45TMz9BD1vVRzi7O0_R9ebd1cWHbPv5_ceL1TYzTJRjxkij8jZpNbqtRN5qxYUhouAq17pgJmdpFg2gVMFTpEtTa5OSeNPqRhHDTlG21J3coObvqu_lEOxehVlSIg_WycU6eWtd4t8u_DDpPTQG3BjUnxyvrPz7xdmd7Pw3SSkVRHCRKry8qxD8zQRxlHsbDfS9cuBTH0YqWqZ1iz7_B_3qp-CSHweK1ZxVnCbq2X1Jv7X8-rsEvFoAE3yMAdr_jfhiwZ210tjDTuuK0qLigpYFy0USmLOf0oe4SQ
Cites_doi 10.3174/ajnr.A5033
10.1007/s10334-016-0589-5
10.3174/ajnr.A6047
10.1002/nbm.4519
10.1002/mrm.22220
10.3174/ajnr.A7441
10.1002/mrm.1910110105
10.1148/radiology.154.2.3966131
10.1097/RLI.0000000000000632
10.1002/mrm.29279
10.1002/mrm.1910400308
10.1177/0271678X17743240
10.1002/jmri.26570
10.1007/978-3-319-24574-4_28
10.1016/0730-725x(86)91059-3
10.2176/nmc.oa.2020-0336
10.2463/mrms.tn.2015-0081
10.1016/j.ejrad.2015.05.021
10.1162/neco.1997.9.8.1735
10.1016/j.pnmrs.2021.03.002
10.1002/mrm.1910140205
10.1002/mrm.1910310219
10.1002/mrm.29201
10.1002/jmri.23618
10.1148/radiology.161.3.3786718
10.2214/ajr.143.6.1157
10.3174/ajnr.A5223
10.1148/rg.2019180091
ContentType Journal Article
Copyright Copyright © 2024, Wada et al.
Copyright © 2024, Wada et al. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
Copyright © 2024, Wada et al. 2024 Wada et al.
Copyright_xml – notice: Copyright © 2024, Wada et al.
– notice: Copyright © 2024, Wada et al. This work is published under https://creativecommons.org/licenses/by/4.0/ (the “License”). Notwithstanding the ProQuest Terms and Conditions, you may use this content in accordance with the terms of the License.
– notice: Copyright © 2024, Wada et al. 2024 Wada et al.
DBID RYH
AAYXX
CITATION
NPM
3V.
7X7
7XB
8FI
8FJ
8FK
ABUWG
AFKRA
AZQEC
BENPR
CCPQU
DWQXO
FYUFA
GHDGH
K9.
M0S
PHGZM
PHGZT
PIMPY
PKEHL
PQEST
PQQKQ
PQUKI
PRINS
7X8
5PM
ADTOC
UNPAY
DOI 10.7759/cureus.60803
DatabaseName CiNii Complete
CrossRef
PubMed
ProQuest Central (Corporate)
Health & Medical Collection
ProQuest Central (purchase pre-March 2016)
Hospital Premium Collection
Hospital Premium Collection (Alumni Edition)
ProQuest Central (Alumni) (purchase pre-March 2016)
ProQuest Central (Alumni)
ProQuest Central UK/Ireland
ProQuest Central Essentials
ProQuest Central
ProQuest One Community College
ProQuest Central Korea
Health Research Premium Collection
Health Research Premium Collection (Alumni)
ProQuest Health & Medical Complete (Alumni)
ProQuest Health & Medical Collection
ProQuest Central Premium
ProQuest One Academic
Publicly Available Content Database
ProQuest One Academic Middle East (New)
ProQuest One Academic Eastern Edition (DO NOT USE)
ProQuest One Academic
ProQuest One Academic UKI Edition
ProQuest Central China
MEDLINE - Academic
PubMed Central (Full Participant titles)
Unpaywall for CDI: Periodical Content
Unpaywall
DatabaseTitle CrossRef
PubMed
Publicly Available Content Database
ProQuest One Academic Middle East (New)
ProQuest Central Essentials
ProQuest One Academic Eastern Edition
ProQuest Health & Medical Complete (Alumni)
ProQuest Central (Alumni Edition)
ProQuest One Community College
ProQuest Hospital Collection
Health Research Premium Collection (Alumni)
ProQuest Central China
ProQuest Hospital Collection (Alumni)
ProQuest Central
ProQuest Health & Medical Complete
Health Research Premium Collection
ProQuest One Academic UKI Edition
Health and Medicine Complete (Alumni Edition)
ProQuest Central Korea
ProQuest Central (New)
ProQuest One Academic
ProQuest One Academic (New)
ProQuest Central (Alumni)
MEDLINE - Academic
DatabaseTitleList Publicly Available Content Database
PubMed
MEDLINE - Academic

Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: UNPAY
  name: Unpaywall
  url: https://proxy.k.utb.cz/login?url=https://unpaywall.org/
  sourceTypes: Open Access Repository
– sequence: 3
  dbid: 7X7
  name: Health & Medical Collection
  url: https://search.proquest.com/healthcomplete
  sourceTypes: Aggregation Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
EISSN 2168-8184
ExternalDocumentID 10.7759/cureus.60803
PMC11190969
38910733
10_7759_cureus_60803
Genre Journal Article
GroupedDBID 53G
5VS
7X7
8FI
8FJ
ABUWG
ADBBV
AFKRA
ALIPV
ALMA_UNASSIGNED_HOLDINGS
AOIJS
BCNDV
BENPR
BPHCQ
BVXVI
CCPQU
FYUFA
HMCUK
HYE
KQ8
M48
PGMZT
PHGZM
PHGZT
PIMPY
PQQKQ
PROAC
RPM
RYH
UKHRP
AAYXX
CITATION
PUEGO
ADRAZ
NPM
3V.
7XB
8FK
AZQEC
DWQXO
K9.
PKEHL
PQEST
PQUKI
PRINS
7X8
5PM
ADTOC
UNPAY
ID FETCH-LOGICAL-c395t-30da2f957cbf792fba69c0946a2bb43c23661beeaa463c2b5c8bc30d6dfbda0c3
IEDL.DBID M48
ISSN 2168-8184
IngestDate Tue Aug 19 09:09:55 EDT 2025
Tue Sep 30 17:08:56 EDT 2025
Fri Sep 05 01:09:52 EDT 2025
Mon Jun 30 07:26:30 EDT 2025
Thu Apr 03 07:05:49 EDT 2025
Wed Oct 01 02:54:47 EDT 2025
Fri Jun 27 01:00:42 EDT 2025
IsDoiOpenAccess true
IsOpenAccess true
IsPeerReviewed true
IsScholarly true
Issue 5
Keywords deep convolutional network
neuro mri
u-net
lstm networks
asl mra
tof mra
deep neural network
Language English
License Copyright © 2024, Wada et al.
This is an open access article distributed under the terms of the Creative Commons Attribution License CC-BY 4.0., which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
cc-by
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c395t-30da2f957cbf792fba69c0946a2bb43c23661beeaa463c2b5c8bc30d6dfbda0c3
Notes ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
OpenAccessLink http://journals.scholarsportal.info/openUrl.xqy?doi=10.7759/cureus.60803
PMID 38910733
PQID 3073863761
PQPubID 2045583
ParticipantIDs unpaywall_primary_10_7759_cureus_60803
pubmedcentral_primary_oai_pubmedcentral_nih_gov_11190969
proquest_miscellaneous_3071515169
proquest_journals_3073863761
pubmed_primary_38910733
crossref_primary_10_7759_cureus_60803
nii_cinii_1871147691543297152
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2024-05-21
PublicationDateYYYYMMDD 2024-05-21
PublicationDate_xml – month: 05
  year: 2024
  text: 2024-05-21
  day: 21
PublicationDecade 2020
PublicationPlace United States
PublicationPlace_xml – name: United States
– name: Palo Alto
– name: Palo Alto (CA)
PublicationTitle Cureus
PublicationTitleAlternate Cureus
PublicationYear 2024
Publisher Springer Science and Business Media LLC
Springer Nature B.V
Cureus
Publisher_xml – name: Springer Science and Business Media LLC
– name: Springer Nature B.V
– name: Cureus
References Azarine A (ref21) 2019; 39
Arnoldner MA (ref10) 2015; 84
Ding J (ref24) 2022; 43
Oishi H (ref15) 2019; 40
Hu HH (ref14) 2017; 30
Ljungberg E (ref25) 2022; 88
Bi X (ref19) 2010; 63
Frahm J (ref5) 1989; 11
Wehrli FW (ref6) 1990; 14
Ljungberg E (ref18) 2021; 123
Bradley WG Jr (ref2) 1985; 154
Edelman RR (ref7) 1994; 31
ref26
Axel L (ref3) 1986; 4
Viswanath SE (ref20) 2012; 36
Guit GL (ref4) 1986; 161
Axel L (ref1) 1984; 143
Jezzard P (ref11) 2018; 38
Hochreiter S (ref30) 1997; 9
ref27
Buxton RB (ref9) 1998; 40
Katsuki M (ref16) 2021; 61
Edalati M (ref8) 2019; 50
Takano N (ref12) 2017; 38
Iryo Y (ref22) 2016; 15
Takano N (ref13) 2017; 38
Ronneberger O (ref28) 2015
(ref29) 2019; 54
van der Plas MC (ref23) 2021; 34
Kronthaler S (ref17) 2022; 88
References_xml – volume: 38
  year: 2017
  ident: ref12
  article-title: Usefulness of non-contrast-enhanced MR angiography using a silent scan for follow-up after Y-configuration stent-assisted coil embolization for basilar tip aneurysms
  publication-title: AJNR Am J Neuroradiol
  doi: 10.3174/ajnr.A5033
– volume: 30
  year: 2017
  ident: ref14
  article-title: Non-gadolinium dynamic angiography of the neurovasculature using arterial spin labeling MRI: preliminary experience in children
  publication-title: MAGMA
  doi: 10.1007/s10334-016-0589-5
– volume: 40
  year: 2019
  ident: ref15
  article-title: Usefulness of silent MR angiography for intracranial aneurysms treated with a flow-diverter device
  publication-title: AJNR Am J Neuroradiol
  doi: 10.3174/ajnr.A6047
– volume: 34
  year: 2021
  ident: ref23
  article-title: Time-encoded golden angle radial arterial spin labeling: simultaneous acquisition of angiography and perfusion data
  publication-title: NMR Biomed
  doi: 10.1002/nbm.4519
– volume: 63
  year: 2010
  ident: ref19
  article-title: Non-contrast-enhanced four-dimensional (4D) intracranial MR angiography: a feasibility study
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.22220
– volume: 43
  year: 2022
  ident: ref24
  article-title: Acceleration of brain susceptibility-weighted imaging with compressed sensitivity encoding: a prospective multicenter study
  publication-title: AJNR Am J Neuroradiol
  doi: 10.3174/ajnr.A7441
– volume: 11
  year: 1989
  ident: ref5
  article-title: Localized proton NMR spectroscopy in different regions of the human brain in vivo. Relaxation times and concentrations of cerebral metabolites
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.1910110105
– volume: 154
  year: 1985
  ident: ref2
  article-title: Blood flow: magnetic resonance imaging
  publication-title: Radiology
  doi: 10.1148/radiology.154.2.3966131
– volume: 54
  year: 2019
  ident: ref29
  article-title: Physicochemical and pharmacokinetic profiles of gadopiclenol: a new macrocyclic gadolinium chelate with high T1 relaxivity: erratum
  publication-title: Invest Radiol
  doi: 10.1097/RLI.0000000000000632
– volume: 88
  year: 2022
  ident: ref17
  article-title: On quantification errors of R2* and proton density fat fraction mapping in trabecularized bone marrow in the static dephasing regime
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.29279
– ident: ref27
– volume: 40
  year: 1998
  ident: ref9
  article-title: A general kinetic model for quantitative perfusion imaging with arterial spin labeling
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.1910400308
– volume: 38
  year: 2018
  ident: ref11
  article-title: Arterial spin labeling for the measurement of cerebral perfusion and angiography
  publication-title: J Cereb Blood Flow Metab
  doi: 10.1177/0271678X17743240
– volume: 50
  year: 2019
  ident: ref8
  article-title: Intravenous contrast-free standardized exercise perfusion imaging in diabetic feet with ulcers
  publication-title: J Magn Reson Imaging
  doi: 10.1002/jmri.26570
– year: 2015
  ident: ref28
  article-title: U-Net: convolutional networks for biomedical image segmentation
  publication-title: Lecture Notes in Computer Science
  doi: 10.1007/978-3-319-24574-4_28
– volume: 4
  year: 1986
  ident: ref3
  article-title: A time-of-flight method of measuring flow velocity by magnetic resonance imaging
  publication-title: Magn Reson Imaging
  doi: 10.1016/0730-725x(86)91059-3
– volume: 61
  year: 2021
  ident: ref16
  article-title: Usefulness of 3 Tesla ultrashort echo time magnetic resonance angiography (UTE-MRA, SILENT-MRA) for evaluation of the mother vessel after cerebral aneurysm clipping: case series of 19 patients
  publication-title: Neurol Med Chir (Tokyo)
  doi: 10.2176/nmc.oa.2020-0336
– volume: 15
  year: 2016
  ident: ref22
  article-title: Evaluation of intracranial vasculatures in healthy subjects with arterial-spin-labeling-based 4D-MR angiography at 3T
  publication-title: Magn Reson Med Sci
  doi: 10.2463/mrms.tn.2015-0081
– volume: 84
  year: 2015
  ident: ref10
  article-title: Imaging of posterior tibial tendon dysfunction--comparison of high-resolution ultrasound and 3T MRI
  publication-title: Eur J Radiol
  doi: 10.1016/j.ejrad.2015.05.021
– volume: 9
  year: 1997
  ident: ref30
  article-title: Long short-term memory
  publication-title: Neural Comput
  doi: 10.1162/neco.1997.9.8.1735
– volume: 123
  year: 2021
  ident: ref18
  article-title: Silent zero TE MR neuroimaging: current state-of-the-art and future directions
  publication-title: Prog Nucl Magn Reson Spectrosc
  doi: 10.1016/j.pnmrs.2021.03.002
– volume: 14
  year: 1990
  ident: ref6
  article-title: Time-of-flight effects in MR imaging of flow
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.1910140205
– volume: 31
  year: 1994
  ident: ref7
  article-title: Signal targeting with alternating radiofrequency (STAR) sequences: application to MR angiography
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.1910310219
– volume: 88
  year: 2022
  ident: ref25
  article-title: Motion corrected silent ZTE neuroimaging
  publication-title: Magn Reson Med
  doi: 10.1002/mrm.29201
– volume: 36
  year: 2012
  ident: ref20
  article-title: Central gland and peripheral zone prostate tumors have significantly different quantitative imaging signatures on 3 Tesla endorectal, in vivo T2-weighted MR imagery
  publication-title: J Magn Reson Imaging
  doi: 10.1002/jmri.23618
– ident: ref26
– volume: 161
  year: 1986
  ident: ref4
  article-title: Levotransposition of the aorta: identification of segmental cardiac anatomy using MR imaging
  publication-title: Radiology
  doi: 10.1148/radiology.161.3.3786718
– volume: 143
  year: 1984
  ident: ref1
  article-title: Blood flow effects in magnetic resonance imaging
  publication-title: AJR Am J Roentgenol
  doi: 10.2214/ajr.143.6.1157
– volume: 38
  year: 2017
  ident: ref13
  article-title: Non-contrast-enhanced silent scan MR angiography of intracranial anterior circulation aneurysms treated with a low-profile visualized intraluminal support device
  publication-title: AJNR Am J Neuroradiol
  doi: 10.3174/ajnr.A5223
– volume: 39
  year: 2019
  ident: ref21
  article-title: Four-dimensional flow MRI: principles and cardiovascular applications
  publication-title: Radiographics
  doi: 10.1148/rg.2019180091
SSID ssib046615957
ssj0001072070
Score 2.260354
Snippet Objective and background This study aimed to develop a deep convolutional neural network (DCNN) model capable of generating synthetic 4D magnetic resonance...
Objective and backgroundThis study aimed to develop a deep convolutional neural network (DCNN) model capable of generating synthetic 4D magnetic resonance...
SourceID unpaywall
pubmedcentral
proquest
pubmed
crossref
nii
SourceType Open Access Repository
Aggregation Database
Index Database
Publisher
StartPage e60803
SubjectTerms Aneurysms
Carotid arteries
Datasets
Machine learning
Medical imaging
Neural networks
Neurology
Neurosurgery
Radiology
Veins & arteries
SummonAdditionalLinks – databaseName: Health & Medical Collection
  dbid: 7X7
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3db9MwELfYkIAXxDeBDRkJeAuL7cROeEEVpZqQygtM6ltkO04XqThd22gqfz13idtRgfYSJbIdxb5z7ncfviPknRIpr0Eyxk5wF6cVbEWjnYirRCnHNLOsPy42_S7PL9Jvs2wWDG7rEFa5-yf2P-qqtWgjP0NezCVsB_Z5eRVj1Sj0roYSGkfkLgOoglytZurGxpIoDiw9xLsrlRVntlu5bv1RAk4SB5LoyDfN_0Dmv7GS9zu_1NtrvVj8JYgmj8jDgCDpaCD5Y3LH-Sfk3jT4yJ8S_2PrAdWtm98glWg6plM993hUkaKpHvNrODry8ybkqqaTVfuLijHFwyBxW8eTBerrtI8loGPnljTkYJ1_oiMKkDEE1G4pxiBun5GLydefX87jUFUhtqLINrFIKs3rIlPW1KrgtdGysKDkSc2NSYXlAkS2cU7rVMKTyWxuLAySVW0qnVjxnBz71ruXhGYJc5q5HDN8w_g6l3CfCVTp6hpkf0Te71a4XA7JM0pQOpAS5UCJsqdERE5h-UtYJbgyUOFYqmQB4E7wQgHAiMjJjjBl2GLr8oYhIvJ23wybAz0e2ru26_sgYGOyiMiLgY77D0EHLVasjEh-QOF9B0y8fdjim8s-ATfIhwJUP3jphz0z3DrBV7dP4DV5wAErYVACZyfkeLPq3ClgnY150zP0HwcP_xg
  priority: 102
  providerName: ProQuest
– databaseName: Unpaywall
  dbid: UNPAY
  link: http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3da9swED_aFLa97PvDXTs06PbmNJJs2epbaBrKIGWwBbonI8lyZpYpIYkZ6V-_k-2Eph3bXoyNJCOd7ny_830I4CThEStQM4aWMxtGOYqiVpaHeS9JLFXU0DpdbHQlLsfRp-v4eg9ONrkwt_z3SRLLU1MtbLXsCgQ2fB8OhHcjdeBgfPW5_82fG0dFGqLOiZqY9ntDdrTNvivLPwHJ-_GQDys3V-tfajq9pWyGT-BiM80mxuRHt1rprrm5U8HxX-t4Co9btEn6DXs8gz3rnsODUetPfwHuy9ohAlyWN6jBSDQgIzVxPq2R-N_6vhaHJX03Kdu61mS4mP0kfEB84kg4K8Lh1Nv2pI47IANr56St1zo5I32C8LINvl0TH6-4fgnj4cXX88uwPYEhNFzGq5D3csUKGSdGF4lkhVZCGjQIhWJaR9wwjupdW6tUJPBJxybVBgeJvNC56hn-Cjpu5uwbIHGPWkVt6quB4_giFXgfc2_-FQXihAA-bHYqmzeFNjI0UDzxsoZ4WU28AI5xGzOkEl4pmns0SoREIMiZTBCMBHC02eCsFcdl5j9kqcBvKQ3g_bYZBcl7R5Szs6ru48EdFTKA1w0_bCfinbn-dMsA0h1O2XbwRbp3W1z5vS7WjbpEopmIL_24Zaq_LvDwfzu-hUcMEZYPZWD0CDqrRWWPESGt9LtWQH4D9Y0PfA
  priority: 102
  providerName: Unpaywall
Title Synthesizing 4D Magnetic Resonance Angiography From 3D Time-of-Flight Using Deep Learning: A Feasibility Study
URI https://cir.nii.ac.jp/crid/1871147691543297152
https://www.ncbi.nlm.nih.gov/pubmed/38910733
https://www.proquest.com/docview/3073863761
https://www.proquest.com/docview/3071515169
https://pubmed.ncbi.nlm.nih.gov/PMC11190969
https://doi.org/10.7759/cureus.60803
UnpaywallVersion publishedVersion
Volume 16
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVAFT
  databaseName: Open Access Digital Library
  customDbUrl:
  eissn: 2168-8184
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0001072070
  issn: 2168-8184
  databaseCode: KQ8
  dateStart: 20150101
  isFulltext: true
  titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html
  providerName: Colorado Alliance of Research Libraries
– providerCode: PRVAFT
  databaseName: Open Access Digital Library
  customDbUrl:
  eissn: 2168-8184
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0001072070
  issn: 2168-8184
  databaseCode: KQ8
  dateStart: 20120101
  isFulltext: true
  titleUrlDefault: http://grweb.coalliance.org/oadl/oadl.html
  providerName: Colorado Alliance of Research Libraries
– providerCode: PRVAQN
  databaseName: PubMed Central
  customDbUrl:
  eissn: 2168-8184
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0001072070
  issn: 2168-8184
  databaseCode: RPM
  dateStart: 20120101
  isFulltext: true
  titleUrlDefault: https://www.ncbi.nlm.nih.gov/pmc/
  providerName: National Library of Medicine
– providerCode: PRVPQU
  databaseName: Health & Medical Collection
  customDbUrl:
  eissn: 2168-8184
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0001072070
  issn: 2168-8184
  databaseCode: 7X7
  dateStart: 20120101
  isFulltext: true
  titleUrlDefault: https://search.proquest.com/healthcomplete
  providerName: ProQuest
– providerCode: PRVPQU
  databaseName: ProQuest Central (NC Live)
  customDbUrl: http://www.proquest.com/pqcentral?accountid=15518
  eissn: 2168-8184
  dateEnd: 99991231
  omitProxy: true
  ssIdentifier: ssj0001072070
  issn: 2168-8184
  databaseCode: BENPR
  dateStart: 20120101
  isFulltext: true
  titleUrlDefault: https://www.proquest.com/central
  providerName: ProQuest
– providerCode: PRVFZP
  databaseName: Scholars Portal Journals: Open Access
  customDbUrl:
  eissn: 2168-8184
  dateEnd: 20250930
  omitProxy: true
  ssIdentifier: ssj0001072070
  issn: 2168-8184
  databaseCode: M48
  dateStart: 20121101
  isFulltext: true
  titleUrlDefault: http://journals.scholarsportal.info
  providerName: Scholars Portal
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwfV3db9MwED-tmzT2gvgmsFVGAt5SYjuxE15QoasmpFYTUKk8RU7ilEjFLW0jCH8953xUVBu8RIn8keTu7Pudfb4DeCm5z3LUjK7mTLt-hkMxUZq7mSelpoqmtD4uNpmKq5n_cR7Mj6DLNtoScHuraWfzSc02y8GvH9U7HPCIXwdSBtGbtNzocjsQCH54D05QJzEr35MW6NerLZ5kXp05jlERuqil_MYL_kYHZ3Bqt-5sLsMDVdUzRXEbCr3pTHmnNGtV_VTL5V-aanwP7rYQkwwbmbgPR9o8gNNJu4n-EMznyiDs2xa_UW0Rf0QmamHsWUZi1_JtAA5NhmZRtMGsyXiz-k74iNjTIu4qd8dLa9CT2tmAjLRekzZI6-ItGRLElK3HbUWsk2L1CGbjyy8frtw27YKb8ijYudzLFMujQKZJLiOWJ0pEKVqBQrEk8XnKOOr0RGulfIFPSZCGSYqNRJYnmfJS_hiOzcrop0ACj2pFdWhDgGP7PBR4H3Br8-U5ggMHXnUUjtdNdI0YrRLLlLhhSlwzxYELJH-MVMIrRRuP-lJEiP44iyQiEAfOO8bEnQjFdvYKBU6g1IEX-2IcPXZLRBm9Kus6FtFRETnwpOHj_kM6MXAgPODwvoKNzH1YYopvdYRuVCAR2obY6eu9MPz3B5_98-3P4YwhjrIOC4yew_FuU-oLxEG7pA89OZd9OHl_Ob3-1K8FHp9m0-vh1z8wvAg-
linkProvider Scholars Portal
linkToHtml http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV1Lb9QwEB61RaK9IJ4l0IKRKLfQxE7iBAmhFctqS7u90Ep7C07iLJG2zrIPVeFH8RuZyWPLCtRbL1EiPxR7ZjzfeMZjgLdSeDxHzWhrwbXtZSiKidLCzhwptavc1K2Pi43Og-Gl93Xsj7fgd3cWhsIquzWxXqizMqU98mPixTBAcXA_zX7adGsUeVe7KzQatjjV1TWabIuPJ32k7xHngy8Xn4d2e6uAnYrIX9rCyRTPI1-mSS4jnicqiFI0cgLFk8QTKReoshKtlfIC_Er8NExSbBRkeZIpJxXY7zbc84TjUa5-OZY3ezqO5ChCTXy9lH50nK7merV4HyAuExuab9sUxf9A7b-xmbsrM1PVtZpO_1J8g4fwoEWsrNew2CPY0uYx3B-1PvknYL5VBlHkoviFWpB5fTZSE0NHIxm5Biifh2Y9Myna3NhsMC-vmOgzOnxil7k9mNL-AKtjF1hf6xlrc75OPrAeQ4jaBvBWjGIeq6dweSfz_Qx2TGn0c2C-42rl6pAyimP7PAzw3RdkQuY5Yg0LjroZjmdNso4YjRyiRNxQIq4pYcEhTn-Ms4RPF01G15NBhGBS8EgioLHgoCNM3Ir0Ir5hQAverItRGMnDoowuV3UdAohuEFmw39Bx_SPkEKYbMi0INyi8rkCJvjdLTPGjTviN-ihCUxM7fbdmhlsH-OL2AbyG3eHF6Cw-Ozk_fQl7HHEaBURw9wB2lvOVPkSctUxe1czN4PtdS9MfbfY-Pw
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwtV3db5RAEJ-0Nam-GL9FW10T6xse7AILJsZcRNJarzHRJveGCywnybmc95Hm_NP865zh4-pF07e-EMgCYXdmmN_s_HYW4KUUHi_RM9pacG17BZpiprSwC0dK7So3d5vlYqOz4Pjc-zj2xzvwu18LQ7TK_p_Y_KiLOqc58gHpYhigObiDsqNFfI6Td7OfNu0gRZnWfjuNVkVO9foCw7fF25MYZX3EefLh6_tju9thwM5F5C9t4RSKl5Ev86yUES8zFUQ5BjyB4lnmiZwLdF-Z1kp5AV5lfh5mOT4UFGVWKCcX-N5duIEdFkQnk2N5Ob_jSI7m1HLtpfSjQb6a69XidYAYTWx5wV1TVf8DuP_yNG-uzEytL9R0-pcTTO7A7Q69smGrbndhR5t7sD_q8vP3wXxZG0SUi-oXekTmxWykJoaWSTJKE1BtD82GZlJ1dbJZMq9_MBEzWohi16WdTGmugDU8BhZrPWNd_dfJGzZkCFc7Mu-aEf9x_QDOr2W8H8KeqY1-DMx3XK1cHVJ1cXy-DAM89wWFk2WJuMOCo36E01lbuCPFgIckkbaSSBtJWHCIw5_iKOHRxfDR9WQQIbAUPJIIbiw46AWTdua9SC-V0YIXm2Y0TMq2KKPrVXMPgUU3iCx41Mpx8yGUHKbdMi0ItyS8uYGKfm-3mOp7U_wbfVOEYSe-9NVGGa7s4JOrO_Ac9tGO0k8nZ6dP4RZHyEbcCO4ewN5yvtKHCLmW2bNGtxl8u25j-gMIhEJ6
linkToUnpaywall http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV3da9swED_aFLa97PvDXTs06PbmNJJs2epbaBrKIGWwBbonI8lyZpYpIYkZ6V-_k-2Eph3bXoyNJCOd7ny_830I4CThEStQM4aWMxtGOYqiVpaHeS9JLFXU0DpdbHQlLsfRp-v4eg9ONrkwt_z3SRLLU1MtbLXsCgQ2fB8OhHcjdeBgfPW5_82fG0dFGqLOiZqY9ntDdrTNvivLPwHJ-_GQDys3V-tfajq9pWyGT-BiM80mxuRHt1rprrm5U8HxX-t4Co9btEn6DXs8gz3rnsODUetPfwHuy9ohAlyWN6jBSDQgIzVxPq2R-N_6vhaHJX03Kdu61mS4mP0kfEB84kg4K8Lh1Nv2pI47IANr56St1zo5I32C8LINvl0TH6-4fgnj4cXX88uwPYEhNFzGq5D3csUKGSdGF4lkhVZCGjQIhWJaR9wwjupdW6tUJPBJxybVBgeJvNC56hn-Cjpu5uwbIHGPWkVt6quB4_giFXgfc2_-FQXihAA-bHYqmzeFNjI0UDzxsoZ4WU28AI5xGzOkEl4pmns0SoREIMiZTBCMBHC02eCsFcdl5j9kqcBvKQ3g_bYZBcl7R5Szs6ru48EdFTKA1w0_bCfinbn-dMsA0h1O2XbwRbp3W1z5vS7WjbpEopmIL_24Zaq_LvDwfzu-hUcMEZYPZWD0CDqrRWWPESGt9LtWQH4D9Y0PfA
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Synthesizing+4D+Magnetic+Resonance+Angiography+From+3D+Time-of-Flight+Using+Deep+Learning%3A+A+Feasibility+Study&rft.jtitle=Cur%C4%93us+%28Palo+Alto%2C+CA%29&rft.au=Wada%2C+Akihiko&rft.au=Akatsu%2C+Toshiya&rft.au=Ikenouchi%2C+Yutaka&rft.au=Suzuki%2C+Michimasa&rft.date=2024-05-21&rft.issn=2168-8184&rft.eissn=2168-8184&rft.volume=16&rft.issue=5&rft.spage=e60803&rft_id=info:doi/10.7759%2Fcureus.60803&rft_id=info%3Apmid%2F38910733&rft.externalDocID=38910733
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=2168-8184&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=2168-8184&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=2168-8184&client=summon