Inter‐Rater Reliability of Ultrasound Imaging of the Trunk Musculature Among Novice Raters

Objective The purpose of this study was to determine the inter‐rater reliability of ultrasound imaging for assessing trunk muscle morphologic characteristics at rest and while contracted among different pairs of novice raters. The secondary purpose was to compare 3 different measurement techniques f...

Full description

Saved in:
Bibliographic Details
Published inJournal of ultrasound in medicine Vol. 30; no. 3; pp. 347 - 356
Main Authors Teyhen, Deydre S., George, Steven Z., Dugan, Jessica L., Williamson, Jared, Neilson, Brett D., Childs, John D.
Format Journal Article
LanguageEnglish
Published England American Institute of Ultrasound in Medicine 01.03.2011
Subjects
Online AccessGet full text
ISSN0278-4297
1550-9613
1550-9613
DOI10.7863/jum.2011.30.3.347

Cover

More Information
Summary:Objective The purpose of this study was to determine the inter‐rater reliability of ultrasound imaging for assessing trunk muscle morphologic characteristics at rest and while contracted among different pairs of novice raters. The secondary purpose was to compare 3 different measurement techniques for assessing lateral abdominal muscle thickness. Methods A single‐group repeated measures reliability study was conducted on 21 healthy participants (mean ± SD, 21.5 ± 4.4 years; 5 female and 16 male) without low back pain. Ultrasound images of the transversus abdominis, internal oblique, rectus abdominis, and lumbar multifidus muscles were obtained by different pairs of novice raters in a counterbalanced order. All raters received a standardized training program before obtaining measurements. Results The intraclass correlation coefficient (1, 3) point estimates ranged from 0.86 to 0.94; the standard error of the measurement ranged from 0.04 to 0.16 cm for the thickness values and 0.67 cm2 for the cross‐sectional area of the rectus abdominis muscle. There was no meaningful difference between the different measurement techniques used to analyze the lateral abdominal muscles. Conclusions Good to excellent reliability was obtained for all measures by novice raters. Minimal differences in reliability were noted between the different measurement techniques to assess lateral abdominal muscle thickness.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ObjectType-Article-2
ObjectType-Feature-1
ISSN:0278-4297
1550-9613
1550-9613
DOI:10.7863/jum.2011.30.3.347