Synchronized tumour tracking with electromagnetic transponders and kV x-ray imaging: evaluation based on a thorax phantom

Intrafractional organ motion remains a source of error in conformal radiotherapy of dynamic targets such as tumours of the lung or of the prostate. The purpose of this work was to devise a method for the continuous and routine measurement of intrafractional organ motion. The method consists of a com...

Full description

Saved in:
Bibliographic Details
Published inPhysics in medicine & biology Vol. 53; no. 14; pp. 3789 - 3805
Main Authors Rau, A W, Nill, S, Eidens, R S, Oelfke, U
Format Journal Article
LanguageEnglish
Published England IOP Publishing 21.07.2008
Subjects
Online AccessGet full text
ISSN0031-9155
1361-6560
DOI10.1088/0031-9155/53/14/006

Cover

More Information
Summary:Intrafractional organ motion remains a source of error in conformal radiotherapy of dynamic targets such as tumours of the lung or of the prostate. The purpose of this work was to devise a method for the continuous and routine measurement of intrafractional organ motion. The method consists of a combination of an electromagnetic (EM), internal marker-based tracking system with the on-board kilovoltage x-ray imaging system of a modern treatment machine. The EM system continuously tracks the target, while x-ray images can be acquired simultaneously if demand arises. An image processing algorithm has been developed to automatically localize and track the EM markers in the x-ray images. We have demonstrated simultaneous target tracking using the EM system and x-ray imaging of a mobile target inside a programmable thorax phantom. The target motion was very well reproduced by both systems. The comparability of the target locations reported by both systems was established (better than 0.25 mm up to target velocities of 3 cm s(-1)). One immediate use of the synchronized system was shown: the generation of a 4D cone beam computed tomography data set using the EM system for the measurement of motion. In conclusion, we have developed a system for the routine measurement of intrafractional motion that continuously provides the 3D position of the target with the ability to acquire images of the treatment field only when needed, thereby eliminating avoidable imaging dose to the patient.
Bibliography:ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Undefined-1
ObjectType-Feature-3
content type line 23
ISSN:0031-9155
1361-6560
DOI:10.1088/0031-9155/53/14/006