Perfluorobutane-enhanced ultrasonography with a Kupffer phase: improved diagnostic sensitivity for hepatocellular carcinoma

Objectives To evaluate the diagnostic accuracy of perfluorobutane contrast-enhanced ultrasonography (CEUS) for hepatocellular carcinoma (HCC) and to explore how accuracy can be improved compared to conventional diagnostic criteria in at-risk patients. Methods A total of 123 hepatic nodules (≥ 1 cm)...

Full description

Saved in:
Bibliographic Details
Published inEuropean radiology Vol. 32; no. 12; pp. 8507 - 8517
Main Authors Hwang, Jeong Ah, Jeong, Woo Kyoung, Kang, Hyo-Jin, Lee, Eun Sun, Park, Hyun Jeong, Lee, Jeong Min
Format Journal Article
LanguageEnglish
Published Berlin/Heidelberg Springer Berlin Heidelberg 01.12.2022
Springer Nature B.V
Subjects
Online AccessGet full text
ISSN1432-1084
0938-7994
1432-1084
DOI10.1007/s00330-022-08900-6

Cover

More Information
Summary:Objectives To evaluate the diagnostic accuracy of perfluorobutane contrast-enhanced ultrasonography (CEUS) for hepatocellular carcinoma (HCC) and to explore how accuracy can be improved compared to conventional diagnostic criteria in at-risk patients. Methods A total of 123 hepatic nodules (≥ 1 cm) from 123 at-risk patients who underwent perfluorobutane CEUS between 2013 and 2020 at three institutions were retrospectively analyzed. Ninety-three percent of subjects had pathological results, except benign lesions stable in follow-up images. We evaluated presence of arterial phase hyperenhancement (APHE), washout time and degree, and Kupffer phase (KP) defects. KP defects are defined as hypoenhancing lesions relative to the liver in KP. HCC was diagnosed in two ways: (1) Liver Imaging Reporting and Data System (LI-RADS) criteria defined as APHE and late (≥ 60 s)/mild washout, and (2) APHE and Kupffer (AK) criteria defined as APHE and KP defect. We explored grayscale features that cause misdiagnosis of HCC and reflected in the adjustment. Diagnostic performance was compared using McNemar’s test. Results There were 77 HCCs, 15 non-HCC malignancies, and 31 benign lesions. An ill-defined margin without hypoechoic halo on grayscale applied as a finding that did not suggest HCC. Regarding diagnosis of HCC, sensitivity of AK criteria (83.1%; 95% confidence interval [CI]: 72.9–90.7%) was higher than that of LI-RADS criteria (75.3%; 95% CI: 64.2–84.4%; p = 0.041). Specificity was 91.3% (95% CI: 79.2–97.6%) in both groups. Conclusion On perfluorobutane CEUS, diagnostic criteria for HCC using KP defect with adjustment by grayscale findings had higher diagnostic performance than conventional criteria without losing specificity. Key Points • Applying Kupffer phase defect instead of late/mild washout and adjusting with grayscale findings can improve the diagnostic performance of perfluorobutane-enhanced US for HCC. • Adjustment with ill-defined margins without a hypoechoic halo for features unlikely to be HCC decreases false positives for HCC diagnosis using the perfluorobutane-enhanced US. • After adjustment with grayscale findings, the sensitivity and accuracy of the APHE and Kupffer criteria were higher than those of the LI-RADS criteria; specificity was 91.3% for both.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:1432-1084
0938-7994
1432-1084
DOI:10.1007/s00330-022-08900-6