Fully automatic segmentation of arbitrarily shaped fiducial markers in cone-beam CT projections

Radio-opaque fiducial markers of different shapes are often implanted in or near abdominal or thoracic tumors to act as surrogates for the tumor position during radiotherapy. They can be used for real-time treatment adaptation, but this requires a robust, automatic segmentation method able to handle...

Full description

Saved in:
Bibliographic Details
Published inPhysics in medicine & biology Vol. 62; no. 4; pp. 1327 - 1341
Main Authors Bertholet, J, Wan, H, Toftegaard, J, Schmidt, M L, Chotard, F, Parikh, P J, Poulsen, P R
Format Journal Article
LanguageEnglish
Published England IOP Publishing 21.02.2017
Subjects
Online AccessGet full text
ISSN0031-9155
1361-6560
1361-6560
DOI10.1088/1361-6560/aa52f7

Cover

Abstract Radio-opaque fiducial markers of different shapes are often implanted in or near abdominal or thoracic tumors to act as surrogates for the tumor position during radiotherapy. They can be used for real-time treatment adaptation, but this requires a robust, automatic segmentation method able to handle arbitrarily shaped markers in a rotational imaging geometry such as cone-beam computed tomography (CBCT) projection images and intra-treatment images. In this study, we propose a fully automatic dynamic programming (DP) assisted template-based (TB) segmentation method. Based on an initial DP segmentation, the DPTB algorithm generates and uses a 3D marker model to create 2D templates at any projection angle. The 2D templates are used to segment the marker position as the position with highest normalized cross-correlation in a search area centered at the DP segmented position. The accuracy of the DP algorithm and the new DPTB algorithm was quantified as the 2D segmentation error (pixels) compared to a manual ground truth segmentation for 97 markers in the projection images of CBCT scans of 40 patients. Also the fraction of wrong segmentations, defined as 2D errors larger than 5 pixels, was calculated. The mean 2D segmentation error of DP was reduced from 4.1 pixels to 3.0 pixels by DPTB, while the fraction of wrong segmentations was reduced from 17.4% to 6.8%. DPTB allowed rejection of uncertain segmentations as deemed by a low normalized cross-correlation coefficient and contrast-to-noise ratio. For a rejection rate of 9.97%, the sensitivity in detecting wrong segmentations was 67% and the specificity was 94%. The accepted segmentations had a mean segmentation error of 1.8 pixels and 2.5% wrong segmentations.
AbstractList Radio-opaque fiducial markers of different shapes are often implanted in or near abdominal or thoracic tumors to act as surrogates for the tumor position during radiotherapy. They can be used for real-time treatment adaptation, but this requires a robust, automatic segmentation method able to handle arbitrarily shaped markers in a rotational imaging geometry such as cone-beam computed tomography (CBCT) projection images and intra-treatment images. In this study, we propose a fully automatic dynamic programming (DP) assisted template-based (TB) segmentation method. Based on an initial DP segmentation, the DPTB algorithm generates and uses a 3D marker model to create 2D templates at any projection angle. The 2D templates are used to segment the marker position as the position with highest normalized cross-correlation in a search area centered at the DP segmented position. The accuracy of the DP algorithm and the new DPTB algorithm was quantified as the 2D segmentation error (pixels) compared to a manual ground truth segmentation for 97 markers in the projection images of CBCT scans of 40 patients. Also the fraction of wrong segmentations, defined as 2D errors larger than 5 pixels, was calculated. The mean 2D segmentation error of DP was reduced from 4.1 pixels to 3.0 pixels by DPTB, while the fraction of wrong segmentations was reduced from 17.4% to 6.8%. DPTB allowed rejection of uncertain segmentations as deemed by a low normalized cross-correlation coefficient and contrast-to-noise ratio. For a rejection rate of 9.97%, the sensitivity in detecting wrong segmentations was 67% and the specificity was 94%. The accepted segmentations had a mean segmentation error of 1.8 pixels and 2.5% wrong segmentations.
Radio-opaque fiducial markers of different shapes are often implanted in or near abdominal or thoracic tumors to act as surrogates for the tumor position during radiotherapy. They can be used for real-time treatment adaptation, but this requires a robust, automatic segmentation method able to handle arbitrarily shaped markers in a rotational imaging geometry such as cone-beam computed tomography (CBCT) projection images and intra-treatment images. In this study, we propose a fully automatic dynamic programming (DP) assisted template-based (TB) segmentation method. Based on an initial DP segmentation, the DPTB algorithm generates and uses a 3D marker model to create 2D templates at any projection angle. The 2D templates are used to segment the marker position as the position with highest normalized cross-correlation in a search area centered at the DP segmented position. The accuracy of the DP algorithm and the new DPTB algorithm was quantified as the 2D segmentation error (pixels) compared to a manual ground truth segmentation for 97 markers in the projection images of CBCT scans of 40 patients. Also the fraction of wrong segmentations, defined as 2D errors larger than 5 pixels, was calculated. The mean 2D segmentation error of DP was reduced from 4.1 pixels to 3.0 pixels by DPTB, while the fraction of wrong segmentations was reduced from 17.4% to 6.8%. DPTB allowed rejection of uncertain segmentations as deemed by a low normalized cross-correlation coefficient and contrast-to-noise ratio. For a rejection rate of 9.97%, the sensitivity in detecting wrong segmentations was 67% and the specificity was 94%. The accepted segmentations had a mean segmentation error of 1.8 pixels and 2.5% wrong segmentations.Radio-opaque fiducial markers of different shapes are often implanted in or near abdominal or thoracic tumors to act as surrogates for the tumor position during radiotherapy. They can be used for real-time treatment adaptation, but this requires a robust, automatic segmentation method able to handle arbitrarily shaped markers in a rotational imaging geometry such as cone-beam computed tomography (CBCT) projection images and intra-treatment images. In this study, we propose a fully automatic dynamic programming (DP) assisted template-based (TB) segmentation method. Based on an initial DP segmentation, the DPTB algorithm generates and uses a 3D marker model to create 2D templates at any projection angle. The 2D templates are used to segment the marker position as the position with highest normalized cross-correlation in a search area centered at the DP segmented position. The accuracy of the DP algorithm and the new DPTB algorithm was quantified as the 2D segmentation error (pixels) compared to a manual ground truth segmentation for 97 markers in the projection images of CBCT scans of 40 patients. Also the fraction of wrong segmentations, defined as 2D errors larger than 5 pixels, was calculated. The mean 2D segmentation error of DP was reduced from 4.1 pixels to 3.0 pixels by DPTB, while the fraction of wrong segmentations was reduced from 17.4% to 6.8%. DPTB allowed rejection of uncertain segmentations as deemed by a low normalized cross-correlation coefficient and contrast-to-noise ratio. For a rejection rate of 9.97%, the sensitivity in detecting wrong segmentations was 67% and the specificity was 94%. The accepted segmentations had a mean segmentation error of 1.8 pixels and 2.5% wrong segmentations.
Author Toftegaard, J
Poulsen, P R
Schmidt, M L
Bertholet, J
Chotard, F
Parikh, P J
Wan, H
Author_xml – sequence: 1
  givenname: J
  surname: Bertholet
  fullname: Bertholet, J
  email: jennbe@rm.dk
  organization: Aarhus University Hospital Department of Oncology, Aarhus, Denmark
– sequence: 2
  givenname: H
  surname: Wan
  fullname: Wan, H
  organization: Washington University School of Medicine Department of Radiation Oncology, St Louis, MO, USA
– sequence: 3
  givenname: J
  surname: Toftegaard
  fullname: Toftegaard, J
  organization: Aarhus University Hospital Department of Oncology, Aarhus, Denmark
– sequence: 4
  givenname: M L
  surname: Schmidt
  fullname: Schmidt, M L
  organization: Aarhus University Hospital Department of Oncology, Aarhus, Denmark
– sequence: 5
  givenname: F
  surname: Chotard
  fullname: Chotard, F
  organization: Polytech Nantes , Nantes, France
– sequence: 6
  givenname: P J
  surname: Parikh
  fullname: Parikh, P J
  organization: Washington University School of Medicine Department of Radiation Oncology, St Louis, MO, USA
– sequence: 7
  givenname: P R
  surname: Poulsen
  fullname: Poulsen, P R
  organization: Aarhus University Hospital Department of Oncology, Aarhus, Denmark
BackLink https://www.ncbi.nlm.nih.gov/pubmed/28114115$$D View this record in MEDLINE/PubMed
BookMark eNp9kD1v3SAUhlGUqrlJu2eqWCpliBsO2BiP1VXzIUXKks4I40PCrW1csIf778uVkwxVm4kj9LzvgeeUHI9hRELOgX0DptQVCAmFrCS7Mqbirj4im7erY7JhTEDRQFWdkNOUdowBKF5-JCdcAZQA1Ybo66Xv99QscxjM7C1N-DTgOOc5jDQ4amLr52iiz1R6NhN21Plusd70dDDxF8ZE_UhtfljRohno9pFOMezQHhrSJ_LBmT7h55fzjPy8_vG4vS3uH27utt_vCyuknAtkpamZMJw5pRoLCI4DWMurpm0aLpRkpuuQyVLWtSh5haarwElnuVI1WHFGLtbevPv3gmnWg08W-96MGJakQUmQIIRgGf3ygi7tgJ2eos8f2etXKRmQK2BjSCmi09avQrII32tg-mBfH1Trg2q92s9B9lfwtfudyNc14sOkd2GJY7akp6HVkusy87zWU-cyd_kP7r-1fwCAsKFn
CODEN PHMBA7
CitedBy_id crossref_primary_10_1016_j_ijrobp_2018_04_016
crossref_primary_10_1088_1361_6560_acc77c
crossref_primary_10_1111_1754_9485_13285
crossref_primary_10_1088_1361_6560_ad154a
crossref_primary_10_1088_2057_1976_acb550
crossref_primary_10_1088_1361_6560_aaae8b
crossref_primary_10_1002_mp_14501
crossref_primary_10_1002_mp_15617
crossref_primary_10_1002_mp_12860
crossref_primary_10_1002_mp_13519
crossref_primary_10_1088_1361_6560_ab2ba8
crossref_primary_10_3389_fonc_2023_1112481
crossref_primary_10_1016_j_radonc_2019_04_014
Cites_doi 10.1118/1.3658566
10.1016/j.ijrobp.2012.07.2367
10.1088/0031-9155/59/11/2787
10.1118/1.3555295
10.1088/0031-9155/61/6/2552
10.1118/1.4771931
10.1016/j.radonc.2016.07.015
10.1088/0031-9155/59/8/1935
10.1016/j.ijrobp.2011.12.007
10.1118/1.3684959
10.1118/1.4904023
10.1118/1.4881335
10.1016/j.ijrobp.2012.12.017
ContentType Journal Article
Copyright 2017 Institute of Physics and Engineering in Medicine
Copyright_xml – notice: 2017 Institute of Physics and Engineering in Medicine
DBID AAYXX
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
DOI 10.1088/1361-6560/aa52f7
DatabaseName CrossRef
Medline
MEDLINE
MEDLINE (Ovid)
MEDLINE
MEDLINE
PubMed
MEDLINE - Academic
DatabaseTitle CrossRef
MEDLINE
Medline Complete
MEDLINE with Full Text
PubMed
MEDLINE (Ovid)
MEDLINE - Academic
DatabaseTitleList
MEDLINE - Academic
MEDLINE
Database_xml – sequence: 1
  dbid: NPM
  name: PubMed
  url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed
  sourceTypes: Index Database
– sequence: 2
  dbid: EIF
  name: MEDLINE
  url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search
  sourceTypes: Index Database
DeliveryMethod fulltext_linktorsrc
Discipline Medicine
Biology
Physics
DocumentTitleAlternate Fully automatic segmentation of arbitrarily shaped fiducial markers in cone-beam CT projections
EISSN 1361-6560
EndPage 1341
ExternalDocumentID 28114115
10_1088_1361_6560_aa52f7
pmbaa52f7
Genre Research Support, Non-U.S. Gov't
Journal Article
GrantInformation_xml – fundername: Kræftens Bekæmpelse
  funderid: https://doi.org/10.13039/100008363
– fundername: Varian Medical Systems
  funderid: https://doi.org/10.13039/100007210
GroupedDBID ---
-DZ
-~X
123
1JI
4.4
5B3
5RE
5VS
5ZH
7.M
7.Q
AAGCD
AAJIO
AAJKP
AALHV
AATNI
ABCXL
ABHWH
ABJNI
ABLJU
ABQJV
ABVAM
ACAFW
ACGFS
ACHIP
AEFHF
AENEX
AFYNE
AKPSB
ALMA_UNASSIGNED_HOLDINGS
AOAED
ASPBG
ATQHT
AVWKF
AZFZN
CBCFC
CEBXE
CJUJL
CRLBU
CS3
DU5
EBS
EDWGO
EJD
EMSAF
EPQRW
EQZZN
F5P
HAK
IHE
IJHAN
IOP
IZVLO
KOT
LAP
M45
N5L
N9A
NT-
NT.
P2P
PJBAE
R4D
RIN
RNS
RO9
ROL
RPA
SY9
TN5
UCJ
W28
XPP
AAYXX
ADEQX
AEINN
CITATION
CGR
CUY
CVF
ECM
EIF
NPM
7X8
ID FETCH-LOGICAL-c366t-e04a703a20f889c1e1f211cc259b9923860adde0646773425ead51f6fc28871c3
IEDL.DBID IOP
ISSN 0031-9155
1361-6560
IngestDate Fri Sep 05 13:59:25 EDT 2025
Thu Jan 02 23:10:36 EST 2025
Wed Oct 01 00:30:30 EDT 2025
Thu Apr 24 23:12:42 EDT 2025
Wed Aug 21 03:40:41 EDT 2024
Thu Jan 07 13:50:37 EST 2021
IsPeerReviewed true
IsScholarly true
Issue 4
Language English
LinkModel DirectLink
MergedId FETCHMERGED-LOGICAL-c366t-e04a703a20f889c1e1f211cc259b9923860adde0646773425ead51f6fc28871c3
Notes Institute of Physics and Engineering in Medicine
PMB-104753.R1
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
PMID 28114115
PQID 1861613330
PQPubID 23479
PageCount 15
ParticipantIDs pubmed_primary_28114115
crossref_primary_10_1088_1361_6560_aa52f7
iop_journals_10_1088_1361_6560_aa52f7
proquest_miscellaneous_1861613330
crossref_citationtrail_10_1088_1361_6560_aa52f7
ProviderPackageCode CITATION
AAYXX
PublicationCentury 2000
PublicationDate 2017-02-21
PublicationDateYYYYMMDD 2017-02-21
PublicationDate_xml – month: 02
  year: 2017
  text: 2017-02-21
  day: 21
PublicationDecade 2010
PublicationPlace England
PublicationPlace_xml – name: England
PublicationTitle Physics in medicine & biology
PublicationTitleAbbrev PMB
PublicationTitleAlternate Phys. Med. Biol
PublicationYear 2017
Publisher IOP Publishing
Publisher_xml – name: IOP Publishing
References 12
13
Fledelius W (2) 2014; 59
1
3
4
Wan H (10) 2016; 61
5
6
7
Wan H (11) 2014; 59
8
9
References_xml – ident: 1
  doi: 10.1118/1.3658566
– ident: 6
  doi: 10.1016/j.ijrobp.2012.07.2367
– volume: 59
  start-page: 2787
  issn: 0031-9155
  year: 2014
  ident: 2
  publication-title: Phys. Med. Biol.
  doi: 10.1088/0031-9155/59/11/2787
– ident: 7
  doi: 10.1118/1.3555295
– volume: 61
  start-page: 2552
  issn: 0031-9155
  year: 2016
  ident: 10
  publication-title: Phys. Med. Biol.
  doi: 10.1088/0031-9155/61/6/2552
– ident: 4
  doi: 10.1118/1.4771931
– ident: 9
  doi: 10.1016/j.radonc.2016.07.015
– volume: 59
  start-page: 1935
  issn: 0031-9155
  year: 2014
  ident: 11
  publication-title: Phys. Med. Biol.
  doi: 10.1088/0031-9155/59/8/1935
– ident: 12
  doi: 10.1016/j.ijrobp.2011.12.007
– ident: 5
  doi: 10.1118/1.3684959
– ident: 3
  doi: 10.1118/1.4904023
– ident: 8
  doi: 10.1118/1.4881335
– ident: 13
  doi: 10.1016/j.ijrobp.2012.12.017
SSID ssj0011824
Score 2.3003798
Snippet Radio-opaque fiducial markers of different shapes are often implanted in or near abdominal or thoracic tumors to act as surrogates for the tumor position...
SourceID proquest
pubmed
crossref
iop
SourceType Aggregation Database
Index Database
Enrichment Source
Publisher
StartPage 1327
SubjectTerms Algorithms
Automation
Breath Holding
Computer Simulation
Cone-Beam Computed Tomography - methods
Fiducial Markers
Humans
Image Processing, Computer-Assisted - methods
image-guided radiotherapy
Imaging, Three-Dimensional - methods
marker segmentation
ROC Curve
Title Fully automatic segmentation of arbitrarily shaped fiducial markers in cone-beam CT projections
URI https://iopscience.iop.org/article/10.1088/1361-6560/aa52f7
https://www.ncbi.nlm.nih.gov/pubmed/28114115
https://www.proquest.com/docview/1861613330
Volume 62
hasFullText 1
inHoldings 1
isFullTextHit
isPrint
journalDatabaseRights – providerCode: PRVIOP
  databaseName: IOP Science Platform
  customDbUrl:
  eissn: 1361-6560
  dateEnd: 99991231
  omitProxy: false
  ssIdentifier: ssj0011824
  issn: 0031-9155
  databaseCode: IOP
  dateStart: 19560101
  isFulltext: true
  titleUrlDefault: https://iopscience.iop.org/
  providerName: IOP Publishing
link http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV1Nb9QwEB21RaBeKJSPLpTKSHDgkN3YThxHnKqKqkIqcGilHpAs27FhBZuNNsmh_HrGiXelIlohblE0sR3bM37j8TwDvClKYwqWoyIZxtFBMVVidJklArFIXmoh-TDS55_E2WX28Sq_2oL3m1yYZRNN_xQfR6LgsQvjgTg5o1zQJHDGzLTOmS-24R6XCIxD9t7nL5sQAgLnkYKZ0ySQoMcY5d9KuLEmbWO9t8PNYdk53YOv6waPp01-TPvOTO2vP7gc__OPHsHDCEfJ8Sj6GLZcvQ_3xwsqr_fhwXkMvePL4ayobZ-ACm7rNdF9txz4Xknrvi1iClNNlp7olZmHbP45SrXfdeMq4udVHzbnySIcB1q1ZF4T9MRdYpxekJMLEneEghI8hcvTDxcnZ0m8pyGxXIgucWmm0XBolnopS0sd9ehWWouelSkRQEqRBiuK4EcUBUcjgbM3p154y9DEUcufwU6NVR4A4Zl0wrs8D8R8qa0kjhzzubdlSJqlcgKz9UgpG0nMw10aP9UQTJdShb5UoS_V2JcTeLf5ohkJPO6QfYtDpKIWt3fIHd2QaxZGCaYyFGSFaio_gdfr-aNQXUMMRtdu2WORUiDG5pynE3g-TqxNs5hE5xQR-ot_bMZL2GUBZIQEe3oIO92qd68QInXmaFCF36cxBQ8
linkProvider IOP Publishing
linkToPdf http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV1Lb9QwEB7RIqpeChQoy6MYCQ4cspvYieMcUWFVHi09tFJvxnZsuiqbjTbJof31jBPvSkVQIXGLoknseDzjbzKezwBv8kLrnGZoSJoyDFB0GWlVpBFHLJIVigvWa_romB-epZ_Ps_NwzmlfC7Oog-sf4-VAFDwMYdgQJyYJ40nkOWMmSmXU5ZO6dBtwt-cp8RV8307WaQQEzwMNM0siT4Qe8pR_esuNdWkD2_475OyXnul9-L7q9LDj5HLctXpsrn_jc_yPr3oAOwGWkveD-EO4Y6tduDccVHm1C1tHIQWPN_s9o6Z5BNKHr1dEde2i530ljf0xD6VMFVk4opZ65qv6ZyjVXKjalsTNys7_pCdzvy1o2ZBZRTAit5G2ak4OTkn4M-SN4TGcTT-eHhxG4byGyDDO28jGqUIHomjshChMYhOH4aUxGGHpAoGk4LH3pgiCeJ4zdBY4i7PEcWcourrEsCewWWGTT4GwVFjubJZ5gr7YlAK1R13mTOGLZxMxgslKW9IEMnN_psZP2SfVhZB-PKUfTzmM5wjerZ-oByKPW2TfoppksObmFrn9G3L1XEtOZYqCNJeowBG8Xs0hiWbrczGqsosOXyk4Ym3GWDyCvWFyrbtFBQapiNSf_WM3XsHWyYep_Prp-Mtz2KYed_ia--QFbLbLzr5E1NTq_d4yfgGIRQpw
openUrl ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Fully+automatic+segmentation+of+arbitrarily+shaped+fiducial+markers+in+cone-beam+CT+projections&rft.jtitle=Physics+in+medicine+%26+biology&rft.au=Bertholet%2C+J&rft.au=Wan%2C+H&rft.au=Toftegaard%2C+J&rft.au=Schmidt%2C+M+L&rft.date=2017-02-21&rft.pub=IOP+Publishing&rft.issn=0031-9155&rft.eissn=1361-6560&rft.volume=62&rft.issue=4&rft.spage=1327&rft.epage=1341&rft_id=info:doi/10.1088%2F1361-6560%2Faa52f7&rft.externalDocID=pmbaa52f7
thumbnail_l http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0031-9155&client=summon
thumbnail_m http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0031-9155&client=summon
thumbnail_s http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0031-9155&client=summon