Simplified Structural Textile Respiration Sensor Based on Capacitive Pressure Sensing Method
We propose a simplified structural textile capacitive respiration sensor (TCRS) for respiration monitoring system. The TCRS is fabricated with conductive textile and Polyester, and it has a simple layered architecture. We derive the respiration by the distance changes between two textile plates in t...
Saved in:
Published in | IEEE sensors journal Vol. 14; no. 9; pp. 3245 - 3251 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
New York
IEEE
01.09.2014
The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Subjects | |
Online Access | Get full text |
ISSN | 1530-437X 1558-1748 |
DOI | 10.1109/JSEN.2014.2327991 |
Cover
Abstract | We propose a simplified structural textile capacitive respiration sensor (TCRS) for respiration monitoring system. The TCRS is fabricated with conductive textile and Polyester, and it has a simple layered architecture. We derive the respiration by the distance changes between two textile plates in the TCRS, which measures the force from the abdominal diameter changes with the respiratory movement. To evaluate the reliability of TCRS, both linearity test and comparison test were carried out. Three times of tensile experiment were performed to confirm the linearity of change in capacitance by the distance change. The result shows that the coefficient of determination (R 2 ) of proposed TCRS is 0.9933. For comparative study, 16 subjects were participating in the experiment. As a result, the proposed respiratory rate detection system using TCRS successfully measures respiration compared with nasal airflow detection (R = 0.9846, p <; 0.001). In Bland-Altman analysis, the upper limit agreement is 0.5018 respirations per minute and lower limit of the agreement is -0.5049 respirations per minute. From these results, we confirmed that the TCRS could be used for monitoring of unconscious persons, avoiding the uncomfortness of subjects. Monitoring respiration using TCRS offers a promising possibility of convenient measurement of respiration rates. In particular, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. |
---|---|
AbstractList | We propose a simplified structural textile capacitive respiration sensor (TCRS) for respiration monitoring system. The TCRS is fabricated with conductive textile and Polyester, and it has a simple layered architecture. We derive the respiration by the distance changes between two textile plates in the TCRS, which measures the force from the abdominal diameter changes with the respiratory movement. To evaluate the reliability of TCRS, both linearity test and comparison test were carried out. Three times of tensile experiment were performed to confirm the linearity of change in capacitance by the distance change. The result shows that the coefficient of determination (R 2 ) of proposed TCRS is 0.9933. For comparative study, 16 subjects were participating in the experiment. As a result, the proposed respiratory rate detection system using TCRS successfully measures respiration compared with nasal airflow detection (R = 0.9846, p <; 0.001). In Bland-Altman analysis, the upper limit agreement is 0.5018 respirations per minute and lower limit of the agreement is -0.5049 respirations per minute. From these results, we confirmed that the TCRS could be used for monitoring of unconscious persons, avoiding the uncomfortness of subjects. Monitoring respiration using TCRS offers a promising possibility of convenient measurement of respiration rates. In particular, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. We propose a simplified structural textile capacitive respiration sensor (TCRS) for respiration monitoring system. The TCRS is fabricated with conductive textile and Polyester, and it has a simple layered architecture. We derive the respiration by the distance changes between two textile plates in the TCRS, which measures the force from the abdominal diameter changes with the respiratory movement. To evaluate the reliability of TCRS, both linearity test and comparison test were carried out. Three times of tensile experiment were performed to confirm the linearity of change in capacitance by the distance change. The result shows that the coefficient of determination ([Formula Omitted]) of proposed TCRS is 0.9933. For comparative study, 16 subjects were participating in the experiment. As a result, the proposed respiratory rate detection system using TCRS successfully measures respiration compared with nasal airflow detection ([Formula Omitted], [Formula Omitted]). In Bland-Altman analysis, the upper limit agreement is 0.5018 respirations per minute and lower limit of the agreement is -0.5049 respirations per minute. From these results, we confirmed that the TCRS could be used for monitoring of unconscious persons, avoiding the uncomfortness of subjects. Monitoring respiration using TCRS offers a promising possibility of convenient measurement of respiration rates. In particular, this technology offers a potentially inexpensive implementation that could extend applications to consumer home-healthcare and mobile-healthcare products. [PUBLICATION ABSTRACT] |
Author | Hangsik Shin Se Dong Min Yonghyeon Yun |
Author_xml | – sequence: 1 givenname: Se Dong surname: Min fullname: Min, Se Dong – sequence: 2 givenname: Yonghyeon surname: Yun fullname: Yun, Yonghyeon – sequence: 3 givenname: Hangsik surname: Shin fullname: Shin, Hangsik |
BookMark | eNp9kEtPwzAQhC1UJNrCD0BcInFOsWM7To5QlZfKQ6RIHJAsN1mDqzQJtoPg35O0FQcOnHZHmtnRfiM0qOoKEDomeEIITs9us9n9JMKETSIaiTQle2hIOE9CIlgy6HeKQ0bFywEaObfCmKSCiyF6zcy6KY02UASZt23uW6vKYAFf3pQQPIFrjFXe1FWQQeVqG1wo13k7PVWNyo03nxA8WnCutbDxmOotuAP_XheHaF-r0sHRbo7R8-VsMb0O5w9XN9PzeZhTnvpQCcyAKM3yRPNcp1hrESdaLSnlCelUQiMWLQtRFGnMVEp0zDXVPFawpIwLOkan27uNrT9acF6u6tZWXaXsGBBKGBasc5GtK7e1cxa0bKxZK_stCZY9RNlDlD1EuYPYZcSfTPfxBoe3ypT_Jk-2SQMAv01xQgXjlP4AlxiCZQ |
CODEN | ISJEAZ |
CitedBy_id | crossref_primary_10_3390_s20143927 crossref_primary_10_1109_JSEN_2020_3000923 crossref_primary_10_3390_s20216233 crossref_primary_10_3390_electronics8050479 crossref_primary_10_1016_j_infrared_2015_09_005 crossref_primary_10_1109_JSEN_2022_3188490 crossref_primary_10_3390_polym15030503 crossref_primary_10_1088_1361_665X_aa782d crossref_primary_10_3390_s24206513 crossref_primary_10_1007_s12283_023_00410_y crossref_primary_10_3390_s18041190 crossref_primary_10_3390_s20164500 crossref_primary_10_3390_mi11121103 crossref_primary_10_3390_s20185446 crossref_primary_10_1177_0040517520915846 crossref_primary_10_32604_iasc_2021_015198 crossref_primary_10_1021_acssensors_2c01628 crossref_primary_10_3390_bios12121069 crossref_primary_10_3390_pr12122644 crossref_primary_10_7498_aps_69_20200987 crossref_primary_10_1007_s12221_017_6629_6 crossref_primary_10_3390_nano12091495 crossref_primary_10_1002_adma_201504366 crossref_primary_10_1109_JSEN_2018_2887303 crossref_primary_10_3390_s21165605 crossref_primary_10_1109_JSEN_2018_2887107 crossref_primary_10_1109_ACCESS_2017_2775180 crossref_primary_10_1109_LSP_2017_2699924 crossref_primary_10_1177_0040517516654108 crossref_primary_10_3390_s21124174 crossref_primary_10_1109_JSEN_2020_3040995 crossref_primary_10_1016_j_smhl_2020_100106 crossref_primary_10_1142_S0218126621300087 crossref_primary_10_4108_eetpht_10_5163 crossref_primary_10_1109_JSEN_2019_2917617 crossref_primary_10_1177_00405175241261401 crossref_primary_10_1109_JSEN_2017_2695565 crossref_primary_10_1002_smll_201901124 crossref_primary_10_3390_s21041119 crossref_primary_10_3390_s22176708 crossref_primary_10_1108_IJCST_05_2021_0061 crossref_primary_10_1109_TIM_2021_3087839 crossref_primary_10_1002_admt_201700136 crossref_primary_10_1088_1361_665X_aca6bc crossref_primary_10_1002_adma_201901958 crossref_primary_10_1002_admt_201900485 crossref_primary_10_1016_j_nanoen_2025_110699 crossref_primary_10_1088_1361_6439_ab2f24 crossref_primary_10_3390_s22103954 crossref_primary_10_3390_s23115155 crossref_primary_10_1007_s13534_025_00456_w crossref_primary_10_3390_s21186042 crossref_primary_10_1149_1945_7111_ab6827 crossref_primary_10_1021_acssensors_0c00210 crossref_primary_10_1109_JSEN_2019_2939567 crossref_primary_10_3390_s22031251 crossref_primary_10_1016_j_snb_2019_127270 crossref_primary_10_1109_JSEN_2020_3008474 crossref_primary_10_1016_j_sna_2020_112425 crossref_primary_10_3390_jsan8020032 crossref_primary_10_1016_j_sna_2024_115701 crossref_primary_10_1039_D4AY01127A crossref_primary_10_1007_s00542_020_04889_4 crossref_primary_10_1039_D0TC05526C crossref_primary_10_1088_0960_1317_26_10_105020 crossref_primary_10_1109_RBME_2020_3043623 crossref_primary_10_3390_bios12050339 crossref_primary_10_1007_s10853_018_3171_x crossref_primary_10_1016_j_sna_2023_114393 crossref_primary_10_1109_JSEN_2016_2561242 crossref_primary_10_1109_ACCESS_2024_3509676 crossref_primary_10_1109_JSEN_2023_3282746 crossref_primary_10_3390_s18072144 crossref_primary_10_1002_admt_201700237 crossref_primary_10_1109_ACCESS_2020_2995861 |
Cites_doi | 10.1109/IEMBS.2006.260648 10.1114/1.1540636 10.1016/j.intcom.2005.07.001 10.1109/JSEN.2010.2082524 10.1109/TBME.2006.884641 10.1089/153056203322502632 10.1109/9780470544228 10.1109/TBME.2007.910679 10.1109/ISSMDBS.2006.360082 10.1097/01.BRS.0000106490.82936.89 10.1136/bmj.313.7069.1375 10.1136/bmj.316.7149.1959 10.1136/bmj.313.7069.1377 10.1016/j.sna.2007.10.069 10.1109/BSN.2006.27 10.1109/IEMBS.1999.803832 10.1109/JSEN.2008.2010356 |
ContentType | Journal Article |
Copyright | Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) Sep 2014 |
Copyright_xml | – notice: Copyright The Institute of Electrical and Electronics Engineers, Inc. (IEEE) Sep 2014 |
DBID | 97E RIA RIE AAYXX CITATION 7SP 7U5 8FD L7M |
DOI | 10.1109/JSEN.2014.2327991 |
DatabaseName | IEEE All-Society Periodicals Package (ASPP) 2005–Present IEEE All-Society Periodicals Package (ASPP) 1998–Present IEEE/IET Electronic Library CrossRef Electronics & Communications Abstracts Solid State and Superconductivity Abstracts Technology Research Database Advanced Technologies Database with Aerospace |
DatabaseTitle | CrossRef Solid State and Superconductivity Abstracts Technology Research Database Advanced Technologies Database with Aerospace Electronics & Communications Abstracts |
DatabaseTitleList | Solid State and Superconductivity Abstracts |
Database_xml | – sequence: 1 dbid: RIE name: IEEE Xplore Digital Library url: https://proxy.k.utb.cz/login?url=https://ieeexplore.ieee.org/ sourceTypes: Publisher |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Geography Engineering |
EISSN | 1558-1748 |
EndPage | 3251 |
ExternalDocumentID | 3393401111 10_1109_JSEN_2014_2327991 6837453 |
Genre | orig-research |
GrantInformation_xml | – fundername: Soonchunhyang University Research Fund grantid: 20120676 – fundername: Chonnam National University. funderid: 10.13039/501100002456 |
GroupedDBID | -~X 0R~ 29I 4.4 5GY 5VS 6IK 97E AAJGR AARMG AASAJ AAWTH ABAZT ABQJQ ABVLG ACGFO ACGFS ACIWK AENEX AETIX AGQYO AGSQL AHBIQ AIBXA AJQPL AKJIK AKQYR ALMA_UNASSIGNED_HOLDINGS ATWAV BEFXN BFFAM BGNUA BKEBE BPEOZ CS3 EBS EJD F5P HZ~ H~9 IFIPE IPLJI JAVBF LAI M43 O9- OCL P2P RIA RIE RNS TWZ ZY4 AAYXX CITATION RIG 7SP 7U5 8FD L7M |
ID | FETCH-LOGICAL-c359t-a704e1af4c8f5cf90ff768fab335810ff83242bd7dd964a91f65f3f56aeb34573 |
IEDL.DBID | RIE |
ISSN | 1530-437X |
IngestDate | Mon Jun 30 07:09:18 EDT 2025 Tue Jul 01 02:46:05 EDT 2025 Thu Apr 24 23:06:29 EDT 2025 Wed Aug 27 03:06:22 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 9 |
Keywords | respiration measurement non-invasive monitoring wearable sensor Capacitive sensor conductive textile |
Language | English |
License | https://ieeexplore.ieee.org/Xplorehelp/downloads/license-information/IEEE.html |
LinkModel | DirectLink |
MergedId | FETCHMERGED-LOGICAL-c359t-a704e1af4c8f5cf90ff768fab335810ff83242bd7dd964a91f65f3f56aeb34573 |
Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 14 |
ORCID | 0000-0002-3353-0310 |
PQID | 1551314074 |
PQPubID | 75733 |
PageCount | 7 |
ParticipantIDs | crossref_primary_10_1109_JSEN_2014_2327991 ieee_primary_6837453 crossref_citationtrail_10_1109_JSEN_2014_2327991 proquest_journals_1551314074 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2014-09-01 |
PublicationDateYYYYMMDD | 2014-09-01 |
PublicationDate_xml | – month: 09 year: 2014 text: 2014-09-01 day: 01 |
PublicationDecade | 2010 |
PublicationPlace | New York |
PublicationPlace_xml | – name: New York |
PublicationTitle | IEEE sensors journal |
PublicationTitleAbbrev | JSEN |
PublicationYear | 2014 |
Publisher | IEEE The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
Publisher_xml | – name: IEEE – name: The Institute of Electrical and Electronics Engineers, Inc. (IEEE) |
References | ref13 ref12 ref15 ref14 ref20 ref22 ref10 ref21 ref2 ref17 dittmar (ref16) 2003 lymeris (ref7) 2004; 108 ref19 ref8 ref9 paradiso (ref11) 2005; 117 ref4 ref3 ref6 khaltaev (ref18) 2005; 31 ref5 leavitt (ref1) 2001; 3 |
References_xml | – ident: ref21 doi: 10.1109/IEMBS.2006.260648 – ident: ref10 doi: 10.1114/1.1540636 – volume: 3 start-page: 2 year: 2001 ident: ref1 article-title: Medscape's response to the institute of medicine report: Crossing the quality chasm: A new health system for the 21st century publication-title: MedGenMed – ident: ref9 doi: 10.1016/j.intcom.2005.07.001 – ident: ref13 doi: 10.1109/JSEN.2010.2082524 – ident: ref20 doi: 10.1109/TBME.2006.884641 – ident: ref22 doi: 10.1089/153056203322502632 – ident: ref19 doi: 10.1109/9780470544228 – ident: ref8 doi: 10.1109/TBME.2007.910679 – ident: ref15 doi: 10.1109/ISSMDBS.2006.360082 – volume: 108 year: 2004 ident: ref7 publication-title: Wearable eHealth Systems for Personalised Health Management State of the Art and Future Challenges – ident: ref17 doi: 10.1097/01.BRS.0000106490.82936.89 – ident: ref3 doi: 10.1136/bmj.313.7069.1375 – ident: ref5 doi: 10.1136/bmj.316.7149.1959 – ident: ref4 doi: 10.1136/bmj.313.7069.1377 – ident: ref12 doi: 10.1016/j.sna.2007.10.069 – ident: ref6 doi: 10.1109/BSN.2006.27 – start-page: 2165 year: 2003 ident: ref16 article-title: Knitted bioclothes for health monitoring publication-title: Conf Proc Annu Int Conf IEEE Eng Med Biol Soc – ident: ref2 doi: 10.1109/IEMBS.1999.803832 – volume: 117 start-page: 9 year: 2005 ident: ref11 article-title: Wearable healthcare systems, new frontiers of e-textile publication-title: Studies Health Technol Informat – ident: ref14 doi: 10.1109/JSEN.2008.2010356 – volume: 31 start-page: 55 year: 2005 ident: ref18 article-title: WHO strategy for prevention and control of chronic obstructive pulmonary disease publication-title: Exp Lung Res |
SSID | ssj0019757 |
Score | 2.406593 |
Snippet | We propose a simplified structural textile capacitive respiration sensor (TCRS) for respiration monitoring system. The TCRS is fabricated with conductive... |
SourceID | proquest crossref ieee |
SourceType | Aggregation Database Enrichment Source Index Database Publisher |
StartPage | 3245 |
SubjectTerms | Capacitance Capacitive sensors Diseases Force Monitoring Monitoring systems Textiles |
Title | Simplified Structural Textile Respiration Sensor Based on Capacitive Pressure Sensing Method |
URI | https://ieeexplore.ieee.org/document/6837453 https://www.proquest.com/docview/1551314074 |
Volume | 14 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NSwMxEB20F_XgVxWrVXLwJG6bdie7m6NKRYR6sBZ6EJZNNkFRWtF60F_vJJsWvxBvG0h2Ay_JzNuZvAE4zAqFMWYmkmTcIpRcRFkmZKS15VnBiy4X7jZy_yq5GOLlSIwW4Hh-F8YY45PPTMs9-lh-OdGv7ldZOyE2hSJehEVaZtVdrXnEQKZe1ZM2MI8wTkchgtnhsn056F25JC5skfuQStn5YoN8UZUfJ7E3L-dr0J9NrMoqeWi9TlVLv3_TbPzvzNdhNfiZ7KRaGBuwYMabsPJJfXATlkIB9Lu3OtwO7l1quSWHlA28pKyT42A3dHTTscGuQ0CeQGQDIr6TZ3ZK5q9k1D4jc6t9BhKr7ho-G9-HvsH6vj71FgzPezdnF1EovBDpWMhpVKQcTaewqDMrtJXcWmIltlCxU0ujVubcMFWmZSkTLGTHJsLGViQFUXMUabwNtfFkbHaAodZIJFPKMlVI7E4pnSjVRdWVaC1PGsBnUOQ6qJK74hiPuWcnXOYOvdyhlwf0GnA0H_JUSXL81bnu0Jh3DEA0oDnDOw-b9iX3xW6IcKa4-_uoPVh2765SzJpQIzjMPvkkU3XgF-MHdRHdfw |
linkProvider | IEEE |
linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwjV1NTxsxEB2l4ZD2QIEUNZBSH3pCbOJkx7vrIyBQCCQHkkg5VFqtvbZArZKKhkP76xl7nagfCHFbS7Zs6dmeeeuZNwBfskJhjJmJJBm3CCUXUZYJGWlteVbwos-Fy0YejZPBDIdzMa_BySYXxhjjg89Mx336t_xyqR_dr7JuQmwKRfwGtgSxiqzK1tq8GcjU63rSEeYRxuk8vGH2uOwOJxdjF8aFHXIgUil7f1khX1blv7vYG5jL9zBaL62KK_nWeVypjv79j2rja9e-A9vB02Sn1dbYhZpZ7MG7P_QH96ARSqDf_WrC18m9Cy635JKyiReVdYIcbEqXN10c7DY8yROMbELUd_nAzsgAloza52RwtY9BYlW24YPxfWgONvIVqj_A7PJiej6IQumFSMdCrqIi5Wh6hUWdWaGt5NYSL7GFip1eGrUy54ipMi1LmWAhezYRNrYiKYico0jjfagvlgvzERhqjUQzpSxThcTvlNKJUn1UfYnW8qQFfA1FroMuuSuP8T33_ITL3KGXO_TygF4LjjdDflSiHC91bjo0Nh0DEC1or_HOw7H9mftyN0Q5Uzx4ftRnaAymo5v85mp8fQhv3TxVwFkb6gSN-UQeykod-Y35BESD4NI |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Simplified+Structural+Textile+Respiration+Sensor+Based+on+Capacitive+Pressure+Sensing+Method&rft.jtitle=IEEE+sensors+journal&rft.au=Min%2C+Se+Dong&rft.au=Yun%2C+Yonghyeon&rft.au=Shin%2C+Hangsik&rft.date=2014-09-01&rft.pub=The+Institute+of+Electrical+and+Electronics+Engineers%2C+Inc.+%28IEEE%29&rft.issn=1530-437X&rft.eissn=1558-1748&rft.volume=14&rft.issue=9&rft.spage=3245&rft_id=info:doi/10.1109%2FJSEN.2014.2327991&rft.externalDBID=NO_FULL_TEXT&rft.externalDocID=3393401111 |
thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=1530-437X&client=summon |
thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=1530-437X&client=summon |
thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=1530-437X&client=summon |