Segmentation of non-viable myocardium in delayed enhancement magnetic resonance images

To evaluate six algorithms for segmenting non-viable left ventricular (LV) myocardium in delayed enhancement (DE) magnetic resonance imaging (MRI). Twenty-three patients with known chronic ischemic heart disease underwent DE-MRI. DE images were first manually thresholded using an interactive region-...

Full description

Saved in:
Bibliographic Details
Published inInternational Journal of Cardiovascular Imaging Vol. 21; no. 2-3; pp. 303 - 311
Main Authors Kolipaka, Arunark, Chatzimavroudis, George P., White, Richard D., O’Donnell, Thomas P., Setser, Randolph M.
Format Journal Article
LanguageEnglish
Published United States Springer Nature B.V 01.04.2005
Subjects
Online AccessGet full text
ISSN1569-5794
1573-0743
DOI10.1007/s10554-004-5806-z

Cover

More Information
Summary:To evaluate six algorithms for segmenting non-viable left ventricular (LV) myocardium in delayed enhancement (DE) magnetic resonance imaging (MRI). Twenty-three patients with known chronic ischemic heart disease underwent DE-MRI. DE images were first manually thresholded using an interactive region-filling tool to isolate non-viable myocardium. Then, six thresholding algorithms, based on the image intensity characteristics of either LV blood pool (BP), viable LV myocardium, or both, were applied to each image. For the Mean-2SD(BP) algorithm, thresholds were equal to the mean BP intensity minus twice its standard deviation. For the Mean + 2SD(Semi), Mean + 3SD(Semi), Mean + 2SD(Auto), and Mean + 3SD(Auto) algorithms, thresholds equaled the mean intensity of viable myocardium plus twice (or thrice, as denoted by the name) the standard deviation of intensity (subscripts denote how these values were determined: automatic or semi-automatic). For the Minimum Intensity algorithm, the threshold equaled the minimum intensity between the BP and LV myocardium mean intensities. Percent Scar was defined as the ratio of non-viable to total myocardial pixels in each image. Agreement between each algorithm and manual thresholding was assessed using Bland-Altman analysis. Mean Percent Scar was 25 +/- 16% by manual thresholding. Five of the six algorithms demonstrated mean bias within +/-3% (all except Mean+2SD(Auto)); however, limits of agreement (LoA) were large in general (range 12-36%). The best overall agreement was demonstrated by the Mean + 2SD(Semi) (bias, 0%; LoA, 12%) and Mean + 3SD(Semi)(bias, -3%; LoA, 14%) algorithms. On average, five of the six algorithms proved satisfactory for clinical implementation; however, in some images, manual correction of automatic results was necessary.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ISSN:1569-5794
1573-0743
DOI:10.1007/s10554-004-5806-z