Reliability and Agreement of Keratometry Measurements Obtained With Eye Surface Profilometry and Partial Coherence Interferometry
The aim of this study was to assess the repeatability of keratometry parameters obtained using the Eye Surface Profiler (ESP) system and their agreement with the IOL Master 500 device. Seventy-one eyes of 71 healthy participants were evaluated. Three repeated measurements were performed using the ES...
Saved in:
Published in | Cornea Vol. 43; no. 3; p. 343 |
---|---|
Main Authors | , , |
Format | Journal Article |
Language | English |
Published |
United States
01.03.2024
|
Subjects | |
Online Access | Get more information |
ISSN | 1536-4798 |
DOI | 10.1097/ICO.0000000000003348 |
Cover
Abstract | The aim of this study was to assess the repeatability of keratometry parameters obtained using the Eye Surface Profiler (ESP) system and their agreement with the IOL Master 500 device.
Seventy-one eyes of 71 healthy participants were evaluated. Three repeated measurements were performed using the ESP system. Simulated keratometry in the flat (SimKf) and steep (SimKs) meridians, astigmatism, and axis were obtained. The same parameters were measured using the IOL Master 500 device. The J0 and J45 vector components of the astigmatism were calculated. The intrasession repeatability was analyzed using within-subject SD (Sw) and intraclass correlation coefficient (ICC). Agreement was assessed using paired statistical tests and the Bland-Altman method.
The Sw was 0.07 mm, 0.04 mm, 0.51 D, 0.33 D, and 0.22 D, and the ICC was 0.96, 0.98, 0.74, 0.61, and 0.55 for SimKf, SimKs, astigmatism, J0, and J45, respectively. The mean difference and limits of agreement when comparing the ESP system with the IOL Master 500 device were 0.37 mm (0.08/0.66) for SimKf ( P < 0.001), 0.18 mm (0.00/0.35) for SimKs ( P < 0.001), -0.93 D (-2.42/0.56) for astigmatism ( P < 0.001), 0.51 D (-0.22/1.24) for J0 ( P < 0.001), and 0.06 D (-0.48/0.60) for J45 ( P = 0.09).
The ESP system provides consistent values for simulated keratometry, showing moderate consistency for astigmatism parameters. Contact lens practitioners should be aware that the ESP system and IOL Master 500 device provide different simulated keratometry from a clinically viewpoint. |
---|---|
AbstractList | The aim of this study was to assess the repeatability of keratometry parameters obtained using the Eye Surface Profiler (ESP) system and their agreement with the IOL Master 500 device.
Seventy-one eyes of 71 healthy participants were evaluated. Three repeated measurements were performed using the ESP system. Simulated keratometry in the flat (SimKf) and steep (SimKs) meridians, astigmatism, and axis were obtained. The same parameters were measured using the IOL Master 500 device. The J0 and J45 vector components of the astigmatism were calculated. The intrasession repeatability was analyzed using within-subject SD (Sw) and intraclass correlation coefficient (ICC). Agreement was assessed using paired statistical tests and the Bland-Altman method.
The Sw was 0.07 mm, 0.04 mm, 0.51 D, 0.33 D, and 0.22 D, and the ICC was 0.96, 0.98, 0.74, 0.61, and 0.55 for SimKf, SimKs, astigmatism, J0, and J45, respectively. The mean difference and limits of agreement when comparing the ESP system with the IOL Master 500 device were 0.37 mm (0.08/0.66) for SimKf ( P < 0.001), 0.18 mm (0.00/0.35) for SimKs ( P < 0.001), -0.93 D (-2.42/0.56) for astigmatism ( P < 0.001), 0.51 D (-0.22/1.24) for J0 ( P < 0.001), and 0.06 D (-0.48/0.60) for J45 ( P = 0.09).
The ESP system provides consistent values for simulated keratometry, showing moderate consistency for astigmatism parameters. Contact lens practitioners should be aware that the ESP system and IOL Master 500 device provide different simulated keratometry from a clinically viewpoint. |
Author | Piñero, David P Martínez-Plaza, Elena Molina-Martín, Ainhoa |
Author_xml | – sequence: 1 givenname: Elena surname: Martínez-Plaza fullname: Martínez-Plaza, Elena organization: University of Valladolid, Valladolid, Spain; and – sequence: 2 givenname: Ainhoa surname: Molina-Martín fullname: Molina-Martín, Ainhoa organization: Group of Optics and Visual Perception, Department of Optics, Pharmacology and Anatomy, University of Alicante, Alicante, Spain – sequence: 3 givenname: David P orcidid: 0000-0002-1546-4807 surname: Piñero fullname: Piñero, David P organization: Department of Ophthalmology, Vithas Medimar International Hospital, Alicante, Spain |
BackLink | https://www.ncbi.nlm.nih.gov/pubmed/37487176$$D View this record in MEDLINE/PubMed |
BookMark | eNpNUEtPAjEYbIxGHvoPjOkfANttt2WPZINIxEB8xCPp46vU7HZJtxz26D8XBRPnMod5JDMDdB6aAAjdUDKmpJB3i3I1Jv_AGJ-coT7NmRhxWUx6aNC2nwdBSpFdoh6TfCKpFH309QyVV9pXPnVYBYunHxGghpBw4_AjRJWaGlLs8BOodh9_pRavdFI-gMXvPm3xrAP8so9OGcDr2DhfnTI_hWsVk1cVLpstRAgHyyIkiA7i0XSFLpyqWrg-8RC93c9ey4fRcjVflNPlyLA8O8wglAAXLnfaCmuBU2p04bjgjBZaGqOJzAgtuCAiN9o4ntPMMaUtdxK0yYbo9ti72-sa7GYXfa1it_n7IvsGP4lkyg |
CitedBy_id | crossref_primary_10_1111_opo_13279 |
ContentType | Journal Article |
Copyright | Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved. |
Copyright_xml | – notice: Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved. |
DBID | CGR CUY CVF ECM EIF NPM |
DOI | 10.1097/ICO.0000000000003348 |
DatabaseName | Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed |
DatabaseTitle | MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) |
DatabaseTitleList | MEDLINE |
Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
DeliveryMethod | no_fulltext_linktorsrc |
Discipline | Medicine |
EISSN | 1536-4798 |
ExternalDocumentID | 37487176 |
Genre | Journal Article |
GrantInformation_xml | – fundername: European Commission grantid: European Union-NextGenerationEU |
GroupedDBID | --- .-D .Z2 01R 0R~ 1J1 40H 4Q1 4Q2 4Q3 53G 5GY 5RE 5VS 71W 77Y 7O~ 8L- AAAAV AAAXR AAGIX AAHPQ AAIQE AAMOA AAMTA AAQKA AARTV AASCR AASOK AAUEB AAXQO AAYEP ABASU ABBUW ABDIG ABJNI ABPXF ABVCZ ABXRP ABXVJ ABZAD ABZZY ACDDN ACDOF ACEWG ACGFO ACGFS ACILI ACLDA ACNCT ACNWC ACWDW ACWRI ACXJB ACXNZ ACZKN ADGGA ADHPY AE6 AENEX AFBFQ AFDTB AFMBP AFSOK AFUWQ AGINI AHOMT AHQNM AHVBC AIJEX AINUH AJCLO AJIOK AJNWD AJZMW AKCTQ AKULP ALKUP ALMA_UNASSIGNED_HOLDINGS ALMTX AMJPA AMKUR AMNEI AOHHW AOQMC BOYCO BQLVK C45 CGR CS3 CUY CVF DIWNM DU5 E.X EBS ECM EEVPB EIF ERAAH EX3 F2K F2L F2M F2N F5P FCALG FL- GNXGY GQDEL H0~ HLJTE HZ~ IKREB IKYAY IN~ IPNFZ JK3 K8S KD2 KMI L-C N9A NPM N~7 N~B O9- OAG OAH OL1 OLG OLH OLU OLV OLY OLZ OPUJH OVD OVDNE OVIDH OVLEI OVOZU OWV OWW OWY OWZ OXXIT P2P RIG RLZ S4R S4S TEORI TSPGW V2I VVN W3M WOQ WOW X3V X3W YFH ZB8 ZFV |
ID | FETCH-LOGICAL-c3526-4010e46f5fbd6dde411cb9f464319b7ccb07201946065cbcf4512f3abd4f7ebc2 |
IngestDate | Mon Jul 21 05:59:51 EDT 2025 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 3 |
Language | English |
License | Copyright © 2023 Wolters Kluwer Health, Inc. All rights reserved. |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c3526-4010e46f5fbd6dde411cb9f464319b7ccb07201946065cbcf4512f3abd4f7ebc2 |
ORCID | 0000-0002-1546-4807 |
PMID | 37487176 |
ParticipantIDs | pubmed_primary_37487176 |
PublicationCentury | 2000 |
PublicationDate | 2024-03-01 |
PublicationDateYYYYMMDD | 2024-03-01 |
PublicationDate_xml | – month: 03 year: 2024 text: 2024-03-01 day: 01 |
PublicationDecade | 2020 |
PublicationPlace | United States |
PublicationPlace_xml | – name: United States |
PublicationTitle | Cornea |
PublicationTitleAlternate | Cornea |
PublicationYear | 2024 |
SSID | ssj0007762 |
Score | 2.4207969 |
Snippet | The aim of this study was to assess the repeatability of keratometry parameters obtained using the Eye Surface Profiler (ESP) system and their agreement with... |
SourceID | pubmed |
SourceType | Index Database |
StartPage | 343 |
SubjectTerms | Astigmatism - diagnosis Contact Lenses Eye Humans Interferometry Reproducibility of Results |
Title | Reliability and Agreement of Keratometry Measurements Obtained With Eye Surface Profilometry and Partial Coherence Interferometry |
URI | https://www.ncbi.nlm.nih.gov/pubmed/37487176 |
Volume | 43 |
hasFullText | |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3JTsMwELUKSIgLYt-RD9yQoUncLEcoIBYVegDBDcWbQIIElXKgN36Eb2W8JDWbWHKIothxoszLeGYy84zQhmilSZSojGSpUISmeU7SUHIiWMS5oLGMhHYUO6fx4QU9vmpdNRqvXtbSU59t8cGXdSX_kSqcA7nqKtk_SLYeFE7AMcgX9iBh2P9Kxjqf2PJsWxalHXCeZfV3_0TTJZf3st973uwMI4GPm2dMhwPA0LzUMdj9Zwnao6dy-MC7ZgFvd40pI9A3NeGFG0dHayKISvZsJ9-0bZe9QtZKXtMTmJ_we4UckO5dPshtFpkshn3MgkHE62o01W1xU9Z9ure6aTeQth7HpOC7mjQXqwjpMFlrS1b6NdbBvNRXwJanyQEt8rRpZFs-aXnLHnzUPrPsk27TNcV-d5DVw72RvKbYAbc1_rn1A_d21TSCRkAP62VVdSzIzfMJzCNVMWaWbH_1OBNovBrig9tizJfzKTTp_A68Y0E0jRqymEHjHZdZMYtePCxhED2usYRLhT0sYR9LuMIS1ljCgCXssIR9LJkBHZZwjSX8Hktz6OJg_7x9SNzyHITrRRUIeOZNSWPVUkzEMEvSIOAsUxRs3CBjCeesmYB5mVHwkVuccUXBuFRRzgRViWQ8nEejRVnIRYSDMGQhXJ1zEcLMDWZpngoYvJkJeGKVLKEF-_KuHywHy3X1Wpe_bVlBE0MIrqIxBR-9XAMLss_WjSDfANv-cnk |
linkProvider | National Library of Medicine |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Reliability+and+Agreement+of+Keratometry+Measurements+Obtained+With+Eye+Surface+Profilometry+and+Partial+Coherence+Interferometry&rft.jtitle=Cornea&rft.au=Mart%C3%ADnez-Plaza%2C+Elena&rft.au=Molina-Mart%C3%ADn%2C+Ainhoa&rft.au=Pi%C3%B1ero%2C+David+P&rft.date=2024-03-01&rft.eissn=1536-4798&rft.volume=43&rft.issue=3&rft.spage=343&rft_id=info:doi/10.1097%2FICO.0000000000003348&rft_id=info%3Apmid%2F37487176&rft_id=info%3Apmid%2F37487176&rft.externalDocID=37487176 |