Effect of Cataract Grade according to Wide-Field Fundus Images on Measurement of Macular Thickness in Cataract Patients

To investigate the effects of cataract grade based on wide-field fundus imaging on macular thickness measured by spectral domain optical coherence tomography (SD-OCT) and its signal-to-noise ratio (SNR). Two hundred cataract patients (200 eyes) with preoperative measurements by wide-field fundus ima...

Full description

Saved in:
Bibliographic Details
Published inKorean journal of ophthalmology Vol. 32; no. 3; pp. 172 - 181
Main Authors Kim, Mingue, Eom, Youngsub, Song, Jong Suk, Kim, Hyo Myung
Format Journal Article
LanguageEnglish
Published Korea (South) The Korean Ophthalmological Society 01.06.2018
대한안과학회
Subjects
Online AccessGet full text
ISSN1011-8942
2092-9382
2092-9382
DOI10.3341/kjo.2017.0067

Cover

More Information
Summary:To investigate the effects of cataract grade based on wide-field fundus imaging on macular thickness measured by spectral domain optical coherence tomography (SD-OCT) and its signal-to-noise ratio (SNR). Two hundred cataract patients (200 eyes) with preoperative measurements by wide-field fundus imaging and macular SD-OCT were enrolled. Cataract severity was graded from 1 to 4 according to the degree of macular obscuring by cataract artifact in fundus photo images. Cataract grade based on wide-field fundus image, the Lens Opacity Classification System III, macular thickness, and SD-OCT SNR were compared. All SD-OCT B-scan images were evaluated to detect errors in retinal layer segmentation. Cataract grade based on wide-field fundus imaging was positively correlated with grade of posterior subcapsular cataracts (rho = 0.486, p < 0.001), but not with nuclear opalescence or cortical cataract using the Lens Opacity Classification System III. Cataract grade was negatively correlated with total macular thickness (rho = -0.509, p < 0.001) and SD-OCT SNR (rho = -0.568, p < 0.001). SD-OCT SNR was positively correlated with total macular thickness (rho = 0.571, p < 0.001). Of 200 eyes, 97 (48.5%) had segmentation errors on SD-OCT. As cataract grade increased and SD-OCT SNR decreased, the percentage of eyes with segmentation errors on SD-OCT increased. All measurements of macular thickness in eyes without segmentation errors were significantly greater than those of eyes with segmentation errors. Posterior subcapsular cataracts had profound effects on cataract grade based on wide-field fundus imaging. As cataract grade based on wide-field fundus image increased, macular thickness tended to be underestimated due to segmentation errors in SD-OCT images. Segmentation errors in SD-OCT should be considered when evaluating macular thickness in eyes with cataracts.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 23
ISSN:1011-8942
2092-9382
2092-9382
DOI:10.3341/kjo.2017.0067