An Adaptive Wearable Parallel Robot for the Treatment of Ankle Injuries

This paper presents the development of a novel adaptive wearable ankle robot for the treatments of ankle sprain through physical rehabilitation. The ankle robot has a bioinspired design, devised after a careful study of the improvement opportunities in the existing ankle robots. Robot design is adap...

Full description

Saved in:
Bibliographic Details
Published inIEEE/ASME transactions on mechatronics Vol. 19; no. 1; pp. 64 - 75
Main Authors Jamwal, Prashant K., Xie, Sheng Q., Hussain, Shahid, Parsons, John G.
Format Journal Article
LanguageEnglish
Published New York IEEE 01.02.2014
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text
ISSN1083-4435
1941-014X
DOI10.1109/TMECH.2012.2219065

Cover

More Information
Summary:This paper presents the development of a novel adaptive wearable ankle robot for the treatments of ankle sprain through physical rehabilitation. The ankle robot has a bioinspired design, devised after a careful study of the improvement opportunities in the existing ankle robots. Robot design is adaptable to subjects of varying physiological abilities and age groups. Ankle robot employs lightweight but powerful pneumatic muscle actuators (PMA) which mimics skeletal muscles in actuation. To address nonlinear characteristics of PMA, a fuzzy-based disturbance observer (FBDO) has been developed. Another instance of an adaptive fuzzy logic controller based on Mamdani inference has been developed and appended with the FBDO to compensate for the transient nature of the PMA. With the proposed control scheme, it is possible to simultaneously control four parallel actuators of the ankle robot and achieve three rotational degrees of freedom. To evaluate the robot design, the disturbance observer, and the adaptive fuzzy logic controller, experiments were performed. The ankle robot was used by a neurologically intact subject. The robot-human interaction was kept as active-passive while the robot was operated on predefined trajectories commonly adopted by the therapists. Trajectory tracking results are reported in the presence of an unpredicted human user intervention, use of compliant and nonlinear actuators, and parallel kinematic structure of the ankle robot.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ObjectType-Article-2
ObjectType-Feature-1
content type line 23
ISSN:1083-4435
1941-014X
DOI:10.1109/TMECH.2012.2219065