Investigation on 10/350 Crowbar Pulse Current Circuit

Structure of main air discharging switch and a crowbar TVS (triggered vacuum switch) are designed and their triggering characteristics are investigated. The experimental results showed that for TVS the operating voltage range is from 1.3 kV to 120 kV, its maximum delay time is 400 ns and its jitter...

Full description

Saved in:
Bibliographic Details
Published inPlasma science & technology Vol. 12; no. 4; pp. 494 - 498
Main Author 姚学玲 陈景亮 孙伟
Format Journal Article
LanguageEnglish
Published IOP Publishing 01.08.2010
Subjects
Online AccessGet full text
ISSN1009-0630
DOI10.1088/1009-0630/12/4/21

Cover

More Information
Summary:Structure of main air discharging switch and a crowbar TVS (triggered vacuum switch) are designed and their triggering characteristics are investigated. The experimental results showed that for TVS the operating voltage range is from 1.3 kV to 120 kV, its maximum delay time is 400 ns and its jitter is 4-10 ns. Based on these results the crowbar 10/350μs (i.e., with a front time of 10μs and a duration of 350 μs) pulse current circuit and its controlling circuit are designed. With a 10μF stored capacitor C and a 6 μF waveform forming induction, a pulse current is generated with a maximum of 100 kA, front time of 10 ns and duration of 350μs. This pulse waveform can be used for testing SPD (surge protective devices).
Bibliography:crowbar circuit, triggered vacuum switch, triggering characteristics, 10/350 μs pulse current waveform
TN7
TG146.21
34-1187/TL
ObjectType-Article-2
SourceType-Scholarly Journals-1
ObjectType-Feature-1
content type line 23
ISSN:1009-0630
DOI:10.1088/1009-0630/12/4/21