Evaluating the Effects of Dynamic Navigation on the Accuracy and Outcomes of the Autogenous Bone Ring Technique for Vertical Ridge Augmentation: A Pilot Randomized Controlled Trial

ABSTRACT Objectives Autogenous bone ring technique (BRT) is a one‐stage vertical augmentation approach with simultaneous implant placement. The aim of this study was to compare the accuracy and efficacy of autogenous BRT assisted by dynamic navigation (DN) with freehand approach (FA) for vertical ri...

Full description

Saved in:
Bibliographic Details
Published inClinical oral implants research Vol. 36; no. 5; pp. 650 - 661
Main Authors Chang, Yu‐chen, Zhu, Ning, Liu, Jiayu, Gao, Xianming, Chen, Gang, Zhang, Yu
Format Journal Article
LanguageEnglish
Published Denmark Wiley Subscription Services, Inc 01.05.2025
Subjects
Online AccessGet full text
ISSN0905-7161
1600-0501
1600-0501
DOI10.1111/clr.14412

Cover

More Information
Summary:ABSTRACT Objectives Autogenous bone ring technique (BRT) is a one‐stage vertical augmentation approach with simultaneous implant placement. The aim of this study was to compare the accuracy and efficacy of autogenous BRT assisted by dynamic navigation (DN) with freehand approach (FA) for vertical ridge augmentation. Materials and Methods Twenty‐four patients eligible for autogenous BRT were randomly assigned to DN or FA groups. Digital preoperative design was conducted for both groups. BRT surgeries were executed with or without the aid of DN in the two groups. Accuracy outcomes evaluated angular and linear deviations at the bone ring in the donor site (BR‐D), recipient site (BR‐R), and implant entry/apex between planned and actual positions revealed by cone‐beam computed tomography. Vertical augmentation‐related outcomes, surgical complications, and patient‐reported outcomes were assessed over 6 months. Results Twenty‐four patients underwent surgery while one was lost to follow‐up. The DN group showed significantly lower mean (SD) BR‐R angular (3.58 [2.07] vs. 8.77 [4.20]°) and entry deviation (1.43 [0.51] vs. 2.01 [0.70] mm). For BR‐D, the DN group had significantly lower angular (4.80 [2.62] vs. 12.97 [6.26]°), entry (1.45 [0.96] vs. 3.52 [1.54] mm), and apex deviation (1.28 [0.64] vs. 3.50 [1.47] mm) compared to the FA group. Implant angular deviation (3.74 [2.14] vs. 9.17 [4.39]°) and apex deviation (1.75 [0.44] vs. 2.35 [0.82] mm) was significantly lower in the DN group. In the FA group, one patient exhibited temporary lower lip hypoesthesia. No significant differences were observed in vertical bone gain, resorption, or patient‐reported outcomes. Conclusions Compared to FA, DN may improve the accuracy of autogenous BRT procedures for vertical ridge augmentation while minimizing invasiveness. Trail Registration This study was registered at the Chinese Clinical Trial Registry (https://www.chictr.org.cn; Registration No. ChiCTR2200065585; registration date: 2022/11/09).
Bibliography:Yu‐chen Chang and Ning Zhu contributed equally as the first authors.
Funding
This study was supported by the Program for New Clinical Techniques and Therapies of Peking University School and Hospital of Stomatology (PKUSSNCT‐22A01), and Beijing Natural Science Foundation (L232113).
ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
content type line 23
ISSN:0905-7161
1600-0501
1600-0501
DOI:10.1111/clr.14412