Internal Magnetic Configuration Measured by ECE Imaging on EAST Tokamak
ECE imaging (electron cyclotron emission imaging) is an important diagnostic which can give 2D imaging of temperature fluctuation in the core of tokamak. A method based on ECE imaging is introduced which can give the information of the position of magnetic axis and the structure of internal magnetic...
Saved in:
Published in | Plasma science & technology Vol. 15; no. 12; pp. 1189 - 1193 |
---|---|
Main Author | |
Format | Journal Article |
Language | English |
Published |
01.12.2013
|
Subjects | |
Online Access | Get full text |
ISSN | 1009-0630 |
DOI | 10.1088/1009-0630/15/12/05 |
Cover
Abstract | ECE imaging (electron cyclotron emission imaging) is an important diagnostic which can give 2D imaging of temperature fluctuation in the core of tokamak. A method based on ECE imaging is introduced which can give the information of the position of magnetic axis and the structure of internal magnetic surface for EAST tokamak. The EFIT equilibrium reconstruction is not reliable due to the absence of important core diagnostic at the initial phase for EAST, so the information given by ECE imaging could help to improve the accuracy of EFIT equilibrium reconstruction. |
---|---|
AbstractList | ECE imaging (electron cyclotron emission imaging) is an important diagnostic which can give 2D imaging of temperature fluctuation in the core of tokamak. A method based on ECE imaging is introduced which can give the information of the position of magnetic axis and the structure of internal magnetic surface for EAST tokamak. The EFIT equilibrium reconstruction is not reliable due to the absence of important core diagnostic at the initial phase for EAST, so the information given by ECE imaging could help to improve the accuracy of EFIT equilibrium reconstruction. ECE imaging (electron cyclotron emission imaging) is an important diagnostic which can give 2D imaging of temperature fluctuation in the core of tokamak. A method based on ECE imaging is introduced which can give the information of the position of magnetic axis and the structure of internal magnetic surface for EAST tokamak. The EFIT equilibrium reconstruction is not reliable due to the absence of important core diagnostic at the initial phase for EAST, so the information given by ECE imaging could help to improve the accuracy of EFIT equilibrium reconstruction. |
Author | 徐明 闻一之 谢锦林 俞昌旋 高炳西 徐小圆 刘万东 胡立群 孙有文 钱金平 万宝年 |
AuthorAffiliation | CAS Key Laboratory of Plasma Physics, University of Science and Technology of China,Hefei 230026, China Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China |
Author_xml | – sequence: 1 fullname: 徐明 闻一之 谢锦林 俞昌旋 高炳西 徐小圆 刘万东 胡立群 孙有文 钱金平 万宝年 |
BookMark | eNp9kLFOwzAQhj0UibbwAkxmYwk5x3HijFUUSqVWDJTZchwnhCZ2a6cDb09Kqw4MTCfd_d_p7puhibFGI_RA4JkA5yEByAJIKISEhSQKgU3Q9Nq8RTPvvwBYnHE6RcuVGbQzssMb2Rg9tArn1tRtc3RyaK3BGy390ekKl9-4yAu86mXTmgaPo2LxvsVbu5O93N2hm1p2Xt9f6hx9vBTb_DVYvy1X-WIdKArJEFQQExKnpNJKEsnrirFKZWXKa0V5BopKgDriJI2YgrpMxoN5EktVaogyRoHO0dN5797Zw1H7QfStV7rrpNH26AVJOEuTiNNojPJzVDnrvdO1UO3w-9TgZNsJAuLkS5zUiJMaQZggkQA2otEfdO_aXrrv_6HHC_RpTXMYJV2pePwoS1JGfwBxWnqZ |
CitedBy_id | crossref_primary_10_1063_1_4959162 crossref_primary_10_1088_2058_6272_aa750d |
Cites_doi | 10.1088/0741-3335/39/11/001 10.1063/1.872025 10.13182/FST08-A1675 10.1063/1.1610781 10.1103/PhysRevLett.96.195004 10.1088/0029-5515/30/6/006 10.1088/1009-0630/13/2/08 10.1063/1.1316748 10.1088/0741-3335/52/1/015008 10.13182/FST48-968 10.1364/AO.49.000E20 10.1063/1.2352727 10.1063/1.2967342 10.1063/1.1790050 10.1088/0029-5515/25/11/007 10.1103/PhysRevLett.107.045004 10.1088/0029-5515/46/8/005 10.1103/PhysRevLett.106.075003 10.1103/PhysRevLett.96.195003 10.1088/1674-1056/18/3/052 |
ContentType | Journal Article |
DBID | 2RA 92L CQIGP W92 ~WA AAYXX CITATION 7U5 8FD H8D L7M |
DOI | 10.1088/1009-0630/15/12/05 |
DatabaseName | 维普期刊资源整合服务平台 中文科技期刊数据库-CALIS站点 中文科技期刊数据库-7.0平台 中文科技期刊数据库-工程技术 中文科技期刊数据库- 镜像站点 CrossRef Solid State and Superconductivity Abstracts Technology Research Database Aerospace Database Advanced Technologies Database with Aerospace |
DatabaseTitle | CrossRef Aerospace Database Solid State and Superconductivity Abstracts Technology Research Database Advanced Technologies Database with Aerospace |
DatabaseTitleList | Aerospace Database |
DeliveryMethod | fulltext_linktorsrc |
Discipline | Physics |
DocumentTitleAlternate | Internal Magnetic Configuration Measured by ECE Imaging on EAST Tokamak |
EndPage | 1193 |
ExternalDocumentID | 10_1088_1009_0630_15_12_05 48179675 |
GroupedDBID | 02O 042 123 1JI 1WK 2B. 2C. 2RA 4.4 5B3 5VR 5VS 5ZH 7.M 7.Q 92E 92I 92L 92Q 93N AAGCD AAJIO AAJKP AALHV AATNI ABHWH ABQJV ACAFW ACGFS ACHIP AEFHF AENEX AFUIB AFYNE AHSEE AKPSB ALMA_UNASSIGNED_HOLDINGS BBWZM CCEZO CCVFK CEBXE CHBEP CJUJL CQIGP CRLBU CS3 CW9 DU5 EBS EDWGO EJD EMSAF EPQRW EQZZN FA0 HAK IJHAN IOP IZVLO JCGBZ KNG KOT LAP M45 N5L N9A NS0 NT- NT. P2P PJBAE Q02 R4D RIN RNS RO9 ROL RPA RW3 S3P SY9 T37 TCJ TGP W28 W92 ~WA -SA -S~ AAYXX ACARI ADEQX AERVB AGQPQ AOAED ARNYC CAJEA CITATION Q-- U1G U5K 7U5 8FD AEINN H8D L7M |
ID | FETCH-LOGICAL-c306t-d0411471deca1a8fd55dc9b78fc3890c3a00f281725c0fb6630864acbe0295303 |
ISSN | 1009-0630 |
IngestDate | Fri Sep 05 08:14:00 EDT 2025 Thu Apr 24 22:54:11 EDT 2025 Tue Jul 01 03:44:28 EDT 2025 Wed Feb 14 10:38:19 EST 2024 |
IsPeerReviewed | true |
IsScholarly | true |
Issue | 12 |
Language | English |
License | http://iopscience.iop.org/info/page/text-and-data-mining http://iopscience.iop.org/page/copyright |
LinkModel | OpenURL |
MergedId | FETCHMERGED-LOGICAL-c306t-d0411471deca1a8fd55dc9b78fc3890c3a00f281725c0fb6630864acbe0295303 |
Notes | MHD instability, internal magnetic configuration, ECE imaging XU Ming , WEN Yizhi , XIE Jinlin , YU Changxuan, GAO Bingxi , XU Xiaoyuan LIU Wandong , HU Liqun, SUN Youwen , QIAN Jinping WAN Baonian 1CAS Key Laboratory of Plasma Physics, University of Science and Technology of China, Hefei 230026, China 2Institute of Plasma Physics, Chinese Academy of Sciences, Hefei 230031, China 34-1187/TL ECE imaging (electron cyclotron emission imaging) is an important diagnostic which can give 2D imaging of temperature fluctuation in the core of tokamak. A method based on ECE imaging is introduced which can give the information of the position of magnetic axis and the structure of internal magnetic surface for EAST tokamak. The EFIT equilibrium reconstruction is not reliable due to the absence of important core diagnostic at the initial phase for EAST, so the information given by ECE imaging could help to improve the accuracy of EFIT equilibrium reconstruction. ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
PQID | 1685762832 |
PQPubID | 23500 |
PageCount | 5 |
ParticipantIDs | proquest_miscellaneous_1685762832 crossref_citationtrail_10_1088_1009_0630_15_12_05 crossref_primary_10_1088_1009_0630_15_12_05 chongqing_primary_48179675 |
ProviderPackageCode | CITATION AAYXX |
PublicationCentury | 2000 |
PublicationDate | 2013-12-01 |
PublicationDateYYYYMMDD | 2013-12-01 |
PublicationDate_xml | – month: 12 year: 2013 text: 2013-12-01 day: 01 |
PublicationDecade | 2010 |
PublicationTitle | Plasma science & technology |
PublicationTitleAlternate | Plasma Science & Technology |
PublicationYear | 2013 |
References | 12 13 15 16 18 Zhang P (19) 2008; 79 Xu X Y (10) 2009; 18 Hartfuss H J (17) 1997; 39 Lao L L (1) 1985; 25 Maget P (14) 2006; 46 4 Luhmann N C (5) 2008; 53 6 8 Lao L L (2) 1990; 30 Xu M (7) 2011; 13 9 Xu X Y (11) 2010; 52 Lao L L (3) 2005; 48 20 |
References_xml | – volume: 39 start-page: 1693 issn: 0741-3335 year: 1997 ident: 17 publication-title: Plasma Physics and Controlled Fusion doi: 10.1088/0741-3335/39/11/001 – ident: 20 doi: 10.1063/1.872025 – volume: 53 start-page: 335 issn: 1536-1055 year: 2008 ident: 5 publication-title: Fusion Science and Technology doi: 10.13182/FST08-A1675 – ident: 4 doi: 10.1063/1.1610781 – ident: 9 doi: 10.1103/PhysRevLett.96.195004 – volume: 30 start-page: 1035 issn: 0029-5515 year: 1990 ident: 2 publication-title: Nuclear Fusion doi: 10.1088/0029-5515/30/6/006 – volume: 13 start-page: 167 issn: 1009-0630 year: 2011 ident: 7 publication-title: Plasma Science and Technology doi: 10.1088/1009-0630/13/2/08 – ident: 15 doi: 10.1063/1.1316748 – volume: 52 start-page: 015008 issn: 0741-3335 year: 2010 ident: 11 publication-title: Plasma Physics and Controlled Fusion doi: 10.1088/0741-3335/52/1/015008 – volume: 48 start-page: 968 issn: 1536-1055 year: 2005 ident: 3 publication-title: Fusion Sci. Technol doi: 10.13182/FST48-968 – ident: 6 doi: 10.1364/AO.49.000E20 – ident: 18 doi: 10.1063/1.2352727 – volume: 79 start-page: 10F103 year: 2008 ident: 19 publication-title: Review of Scientific Instruments doi: 10.1063/1.2967342 – ident: 16 doi: 10.1063/1.1790050 – volume: 25 start-page: 1611 issn: 0029-5515 year: 1985 ident: 1 publication-title: Nuclear Fusion doi: 10.1088/0029-5515/25/11/007 – ident: 13 doi: 10.1103/PhysRevLett.107.045004 – volume: 46 start-page: 797 issn: 0029-5515 year: 2006 ident: 14 publication-title: Nuclear Fusion doi: 10.1088/0029-5515/46/8/005 – ident: 12 doi: 10.1103/PhysRevLett.106.075003 – ident: 8 doi: 10.1103/PhysRevLett.96.195003 – volume: 18 start-page: 1153 issn: 1674-1056 year: 2009 ident: 10 publication-title: Chinese Physics doi: 10.1088/1674-1056/18/3/052 |
SSID | ssj0054983 |
Score | 1.9344801 |
Snippet | ECE imaging (electron cyclotron emission imaging) is an important diagnostic which can give 2D imaging of temperature fluctuation in the core of tokamak. A... ECE imaging (electron cyclotron emission imaging) is an important diagnostic which can give 2D imaging of temperature fluctuation in the core of tokamak. A... |
SourceID | proquest crossref chongqing |
SourceType | Aggregation Database Enrichment Source Index Database Publisher |
StartPage | 1189 |
SubjectTerms | Cyclotrons Diagnostic systems EAST装置 Emission Fluctuation Imaging Reconstruction Tokamak devices Two dimensional 二维成像 托卡马克 欧洲 测量 温度波动 磁场位形 辐射成像 |
Title | Internal Magnetic Configuration Measured by ECE Imaging on EAST Tokamak |
URI | http://lib.cqvip.com/qk/84262X/201312/48179675.html https://www.proquest.com/docview/1685762832 |
Volume | 15 |
hasFullText | 1 |
inHoldings | 1 |
isFullTextHit | |
isPrint | |
journalDatabaseRights | – providerCode: PRVIOP databaseName: IOP Science Platform issn: 1009-0630 databaseCode: IOP dateStart: 19990101 customDbUrl: isFulltext: true dateEnd: 99991231 titleUrlDefault: https://iopscience.iop.org/ omitProxy: false ssIdentifier: ssj0054983 providerName: IOP Publishing |
link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwELfQEIIXxKfo-JCReItC4yROnccJFcakwiQ6qTxZtpN01dYUWCLB_nruHDtNGSDGSxS5yUXy_XqfvjtCXpWJykSR6DDnkzJMU6NDoXkVAjbSpALEVBkWJ88-ZIcn6dGCL7YBfVtd0ujX5vK3dSX_w1VYA75ilew1ONsThQW4B_7CFTgM13_isQvnnQcztayxGtEW8K2WrWPrrAsAWhtzitPl124mUR1MDz7Ng_nmTK3V2dBAPQZreq0CX-2DwGiuRN8XbXfi3mk9m9ix0uvz6vJ01T_VpT6OVtiMo5curUvy18vvrUOmCzqwZHCAo5OTNqeSuZSKF6R8CJh4IBbBi8kHKpaxbiriFfENIs9GEhxxvMfWFwybxEZ8q7J8mv4XTdafL7SZdSGwIXMukZJkXLJYYrPbm_Eky3DWxfuPx15ng5MsulIM92VXXgU0xv3amPExi8c46PA2qKZ6-RW2edec2dXm1kSZ3yN3nW9BDzqg3Cc3yvoBuWXP-JqLh-Sdhwv1cKE7cKEeLlT_oAAX6uBC4SeEC3VweURO3k7nbw5DN0cjNOAQNmERpeD1TlhRGsWUqArOC5PriagMmKuRSVQUVbEAU5abqNJgg4KfmyqjyyjOOdg4j8levanLJ4RGBRg9Gq5xlafw58-BclSxFKzGEl8ekf1-a-SXrl-KTIF0Do7piDC_V9K4DvQ4COVc_plfIxL073h6f3v6pWeBBDGJuS9Vl5v2QrJMgGeNc7n2r0XxKbmzxf8zstd8a8vnYIY2-oVF0E-Lvnxe |
linkProvider | IOP Publishing |
openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Internal+Magnetic+Configuration+Measured+by+ECE+Imaging+on+EAST+Tokamak&rft.jtitle=Plasma+science+%26+technology&rft.au=Xu%2C+Ming&rft.au=Wen%2C+Yizhi&rft.au=Xie%2C+Jinlin&rft.au=Yu%2C+Changxuan&rft.date=2013-12-01&rft.issn=1009-0630&rft.volume=15&rft.issue=12&rft.spage=1189&rft.epage=1193&rft_id=info:doi/10.1088%2F1009-0630%2F15%2F12%2F05&rft.externalDBID=n%2Fa&rft.externalDocID=10_1088_1009_0630_15_12_05 |
thumbnail_s | http://utb.summon.serialssolutions.com/2.0.0/image/custom?url=http%3A%2F%2Fimage.cqvip.com%2Fvip1000%2Fqk%2F84262X%2F84262X.jpg |