High stability adaptive microgrid control method using fuzzy logic

•Reactive power sharing between parallel inverters on a microgrid is simulated.•A P–f and P &Q–V droop control method provides reduced reactive power sharing error.•A first fuzzy logic controller (FLC) provides an adaptive gain coefficient for P–V droop.•A second FLC with integrator compensates...

Full description

Saved in:
Bibliographic Details
Published inSustainable cities and society Vol. 25; pp. 57 - 64
Main Authors Fattahi, Javad, Schriemer, Henry, Bacque, Ben, Orr, Ray, Hinzer, Karin, Haysom, Joan E.
Format Journal Article
LanguageEnglish
Published Elsevier Ltd 01.08.2016
Subjects
Online AccessGet full text
ISSN2210-6707
2210-6715
DOI10.1016/j.scs.2016.03.003

Cover

More Information
Summary:•Reactive power sharing between parallel inverters on a microgrid is simulated.•A P–f and P &Q–V droop control method provides reduced reactive power sharing error.•A first fuzzy logic controller (FLC) provides an adaptive gain coefficient for P–V droop.•A second FLC with integrator compensates reactive power error through P &Q coupling.•Root locus and time domain analysis show high stability and fast dynamic response. Appropriate control strategies for power sharing between multiple generation units operating in parallel are required to create a stable AC microgrid bus. In this paper, we explore the droop control strategy, implemented by power electronics units, to maintain a stable AC bus voltage without the need for a separate (central) communication layer. In particular, our suggested control method is based on adaptive fuzzy logic control (FLC). Fundamentally in low voltage microgrids, due to the effects of feeder and line impedance, the droop control method is subject to real and reactive power coupling and steady-state reactive power sharing errors, and in particular for complex microgrid configurations, the reactive power sharing poses certain challenges. To improve the reactive power sharing equalization, an enhanced FLC strategy has been utilized to calculate a droop coefficient for reactive power control. A second FLC is implemented in an integrator controller, where the reactive power error has been compensated through the injection of small real power disturbances. Root locus analysis of a representative microgrid with three inverters has been undertaken to confirm that stable solutions are feasible. Implementation of a set of gain values into time domain analysis demonstrates excellent voltage and frequency stability on the main bus, as well as equalized real and reactive power sharing between inverters to within ±5W and ±10 VAR, respectively.
ISSN:2210-6707
2210-6715
DOI:10.1016/j.scs.2016.03.003