Diagnostic Performance of an Advanced Modeled Iterative Reconstruction Algorithm for Low-Contrast Detectability with a Third-Generation Dual-Source Multidetector CT Scanner: Potential for Radiation Dose Reduction in a Multireader Study
To assess the effect of radiation dose reduction on low-contrast detectability by using an advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) algorithm in a contrast-detail phantom with a third-generation dual-source multidetector computed tomography (CT) scan...
Saved in:
| Published in | Radiology Vol. 275; no. 3; pp. 735 - 745 |
|---|---|
| Main Authors | , , , |
| Format | Journal Article |
| Language | English |
| Published |
United States
01.06.2015
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 0033-8419 1527-1315 1527-1315 |
| DOI | 10.1148/radiol.15142005 |
Cover
| Abstract | To assess the effect of radiation dose reduction on low-contrast detectability by using an advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) algorithm in a contrast-detail phantom with a third-generation dual-source multidetector computed tomography (CT) scanner.
A proprietary phantom with a range of low-contrast cylindrical objects, representing five contrast levels (range, 5-20 HU) and three sizes (range, 2-6 mm) was fabricated with a three-dimensional printer and imaged with a third-generation dual-source CT scanner at various radiation dose index levels (range, 0.74-5.8 mGy). Image data sets were reconstructed by using different section thicknesses (range, 0.6-5.0 mm) and reconstruction algorithms (filtered back projection [FBP] and ADMIRE with a strength range of three to five). Eleven independent readers blinded to technique and reconstruction method assessed all data sets in two reading sessions by measuring detection accuracy with a two-alternative forced choice approach (first session) and by scoring the total number of visible object groups (second session). Dose reduction potentials based on both reading sessions were estimated. Results between FBP and ADMIRE were compared by using both paired t tests and analysis of variance tests at the 95% significance level.
During the first session, detection accuracy increased with increasing contrast, size, and dose index (diagnostic accuracy range, 50%-87%; interobserver variability, ±7%). When compared with FBP, ADMIRE improved detection accuracy by 5.2% on average across the investigated variables (P < .001). During the second session, a significantly increased number of visible objects was noted with increasing radiation dose index, section thickness, and ADMIRE strength over FBP (up to 80% more visible objects, P < .001). Radiation dose reduction potential ranged from 56% to 60% and from 4% to 80% during the two sessions, respectively.
Low-contrast detectability performance increased with increasing object size, object contrast, dose index, section thickness, and ADMIRE strength. Compared with FBP, ADMIRE allows a substantial radiation dose reduction while preserving low-contrast detectability. Online supplemental material is available for this article. |
|---|---|
| AbstractList | To assess the effect of radiation dose reduction on low-contrast detectability by using an advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) algorithm in a contrast-detail phantom with a third-generation dual-source multidetector computed tomography (CT) scanner.PURPOSETo assess the effect of radiation dose reduction on low-contrast detectability by using an advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) algorithm in a contrast-detail phantom with a third-generation dual-source multidetector computed tomography (CT) scanner.A proprietary phantom with a range of low-contrast cylindrical objects, representing five contrast levels (range, 5-20 HU) and three sizes (range, 2-6 mm) was fabricated with a three-dimensional printer and imaged with a third-generation dual-source CT scanner at various radiation dose index levels (range, 0.74-5.8 mGy). Image data sets were reconstructed by using different section thicknesses (range, 0.6-5.0 mm) and reconstruction algorithms (filtered back projection [FBP] and ADMIRE with a strength range of three to five). Eleven independent readers blinded to technique and reconstruction method assessed all data sets in two reading sessions by measuring detection accuracy with a two-alternative forced choice approach (first session) and by scoring the total number of visible object groups (second session). Dose reduction potentials based on both reading sessions were estimated. Results between FBP and ADMIRE were compared by using both paired t tests and analysis of variance tests at the 95% significance level.MATERIALS AND METHODSA proprietary phantom with a range of low-contrast cylindrical objects, representing five contrast levels (range, 5-20 HU) and three sizes (range, 2-6 mm) was fabricated with a three-dimensional printer and imaged with a third-generation dual-source CT scanner at various radiation dose index levels (range, 0.74-5.8 mGy). Image data sets were reconstructed by using different section thicknesses (range, 0.6-5.0 mm) and reconstruction algorithms (filtered back projection [FBP] and ADMIRE with a strength range of three to five). Eleven independent readers blinded to technique and reconstruction method assessed all data sets in two reading sessions by measuring detection accuracy with a two-alternative forced choice approach (first session) and by scoring the total number of visible object groups (second session). Dose reduction potentials based on both reading sessions were estimated. Results between FBP and ADMIRE were compared by using both paired t tests and analysis of variance tests at the 95% significance level.During the first session, detection accuracy increased with increasing contrast, size, and dose index (diagnostic accuracy range, 50%-87%; interobserver variability, ±7%). When compared with FBP, ADMIRE improved detection accuracy by 5.2% on average across the investigated variables (P < .001). During the second session, a significantly increased number of visible objects was noted with increasing radiation dose index, section thickness, and ADMIRE strength over FBP (up to 80% more visible objects, P < .001). Radiation dose reduction potential ranged from 56% to 60% and from 4% to 80% during the two sessions, respectively.RESULTSDuring the first session, detection accuracy increased with increasing contrast, size, and dose index (diagnostic accuracy range, 50%-87%; interobserver variability, ±7%). When compared with FBP, ADMIRE improved detection accuracy by 5.2% on average across the investigated variables (P < .001). During the second session, a significantly increased number of visible objects was noted with increasing radiation dose index, section thickness, and ADMIRE strength over FBP (up to 80% more visible objects, P < .001). Radiation dose reduction potential ranged from 56% to 60% and from 4% to 80% during the two sessions, respectively.Low-contrast detectability performance increased with increasing object size, object contrast, dose index, section thickness, and ADMIRE strength. Compared with FBP, ADMIRE allows a substantial radiation dose reduction while preserving low-contrast detectability. Online supplemental material is available for this article.CONCLUSIONLow-contrast detectability performance increased with increasing object size, object contrast, dose index, section thickness, and ADMIRE strength. Compared with FBP, ADMIRE allows a substantial radiation dose reduction while preserving low-contrast detectability. Online supplemental material is available for this article. To assess the effect of radiation dose reduction on low-contrast detectability by using an advanced modeled iterative reconstruction (ADMIRE; Siemens Healthcare, Forchheim, Germany) algorithm in a contrast-detail phantom with a third-generation dual-source multidetector computed tomography (CT) scanner. A proprietary phantom with a range of low-contrast cylindrical objects, representing five contrast levels (range, 5-20 HU) and three sizes (range, 2-6 mm) was fabricated with a three-dimensional printer and imaged with a third-generation dual-source CT scanner at various radiation dose index levels (range, 0.74-5.8 mGy). Image data sets were reconstructed by using different section thicknesses (range, 0.6-5.0 mm) and reconstruction algorithms (filtered back projection [FBP] and ADMIRE with a strength range of three to five). Eleven independent readers blinded to technique and reconstruction method assessed all data sets in two reading sessions by measuring detection accuracy with a two-alternative forced choice approach (first session) and by scoring the total number of visible object groups (second session). Dose reduction potentials based on both reading sessions were estimated. Results between FBP and ADMIRE were compared by using both paired t tests and analysis of variance tests at the 95% significance level. During the first session, detection accuracy increased with increasing contrast, size, and dose index (diagnostic accuracy range, 50%-87%; interobserver variability, ±7%). When compared with FBP, ADMIRE improved detection accuracy by 5.2% on average across the investigated variables (P < .001). During the second session, a significantly increased number of visible objects was noted with increasing radiation dose index, section thickness, and ADMIRE strength over FBP (up to 80% more visible objects, P < .001). Radiation dose reduction potential ranged from 56% to 60% and from 4% to 80% during the two sessions, respectively. Low-contrast detectability performance increased with increasing object size, object contrast, dose index, section thickness, and ADMIRE strength. Compared with FBP, ADMIRE allows a substantial radiation dose reduction while preserving low-contrast detectability. Online supplemental material is available for this article. |
| Author | Solomon, Justin Mileto, Achille Samei, Ehsan Ramirez-Giraldo, Juan Carlos |
| Author_xml | – sequence: 1 givenname: Justin surname: Solomon fullname: Solomon, Justin – sequence: 2 givenname: Achille surname: Mileto fullname: Mileto, Achille – sequence: 3 givenname: Juan Carlos surname: Ramirez-Giraldo fullname: Ramirez-Giraldo, Juan Carlos – sequence: 4 givenname: Ehsan surname: Samei fullname: Samei, Ehsan |
| BackLink | https://www.ncbi.nlm.nih.gov/pubmed/25751228$$D View this record in MEDLINE/PubMed |
| BookMark | eNp1kk1vEzEQhi1URD_gzA35yGVb27vOrrlVSSmVUlE14bya2LOtkWMX29sqv5k_gfNRDkicRpae950Zz3tKjnzwSMhHzs45b7qLCMYGd84lbwRj8g054VK0Fa-5PCInjNV11TVcHZPTlH4yxhvZte_IsZCt5EJ0J-T3zMKDDylbTe8wDiGuwWukYaDg6aV53r4MvQ0GXak3GSNk-4z0HnXwKcdRZxsK6R5CtPlxTYsFnYeXahp8jpAynWFGnWFlnc0b-lIgCnT5aKOprtHv_IrBbARXLcIYS_Pb0WVrdrJiNl3ShQZfyC_0LmT02YLbtbkv2x_UIW1HModprC8tdi4RwWCkizyazXvydgCX8MOhnpEfX6-W02_V_Pv1zfRyXmmh2lzJFQB0XHUAjDUSzEopiaCMbgYpWKsEdBNpdMdl02pVD9iayVAUteRcCVWfkc9736cYfo2Ycr-2SaNz4DGMqeeTTnRKMCEL-umAjqs1mv4p2jXETf96oAJc7AEdQ0oRh78IZ_02Av0-Av1rBIpC_qPQNu9-qZzDuv_q_gCUQ7wk |
| CitedBy_id | crossref_primary_10_1016_j_ejmp_2015_09_013 crossref_primary_10_1016_j_acra_2018_09_021 crossref_primary_10_1002_jmrs_387 crossref_primary_10_1016_j_ejrad_2020_109426 crossref_primary_10_1007_s00247_019_04532_z crossref_primary_10_12688_f1000research_147345_1 crossref_primary_10_1002_mp_13284 crossref_primary_10_1002_mp_13286 crossref_primary_10_1097_RCT_0000000000001037 crossref_primary_10_1016_j_radphyschem_2025_112537 crossref_primary_10_1097_MD_0000000000014947 crossref_primary_10_2214_AJR_19_22053 crossref_primary_10_1097_RCT_0000000000000626 crossref_primary_10_1118_1_4939257 crossref_primary_10_1007_s00431_023_05194_8 crossref_primary_10_1016_j_ejrad_2016_04_012 crossref_primary_10_1177_0284185117738548 crossref_primary_10_1177_0284185119890088 crossref_primary_10_1016_j_ejmp_2021_05_025 crossref_primary_10_1016_j_clinimag_2018_02_007 crossref_primary_10_1088_1361_6560_abeea5 crossref_primary_10_1002_mp_16300 crossref_primary_10_1002_acm2_13149 crossref_primary_10_1177_0284185117703152 crossref_primary_10_1007_s00330_016_4601_2 crossref_primary_10_1002_acm2_12974 crossref_primary_10_1259_bjr_20170632 crossref_primary_10_6009_jjrt_2021_JSRT_77_2_220 crossref_primary_10_1016_j_diii_2019_04_006 crossref_primary_10_1117_1_JMI_5_3_035504 crossref_primary_10_2214_AJR_17_18566 crossref_primary_10_1002_acm2_13032 crossref_primary_10_1007_s00330_021_07810_3 crossref_primary_10_1371_journal_pone_0256564 crossref_primary_10_1093_rpd_ncaa034 crossref_primary_10_3390_diagnostics11061000 crossref_primary_10_1097_RLI_0000000000000925 crossref_primary_10_1148_radiol_2017161966 crossref_primary_10_1259_bjr_20170927 crossref_primary_10_1002_acm2_13719 crossref_primary_10_1371_journal_pone_0240184 crossref_primary_10_1007_s00330_022_09206_3 crossref_primary_10_1177_0284185118820699 crossref_primary_10_1016_j_ejrad_2016_02_021 crossref_primary_10_1016_j_ejrad_2019_108703 crossref_primary_10_1177_0284185117740931 crossref_primary_10_3390_diagnostics13111862 crossref_primary_10_1007_s00062_018_0740_y crossref_primary_10_1259_dmfr_20170423 crossref_primary_10_3174_ajnr_A4502 crossref_primary_10_1097_RLI_0000000000000216 crossref_primary_10_1016_j_jcct_2020_01_010 crossref_primary_10_14316_pmp_2016_27_4_196 crossref_primary_10_1007_s00330_023_09491_6 crossref_primary_10_2214_AJR_16_16940 crossref_primary_10_1118_1_4923172 crossref_primary_10_1016_j_acra_2016_12_017 crossref_primary_10_1016_j_ejmp_2020_06_004 crossref_primary_10_1002_mp_12125 crossref_primary_10_1002_mp_13845 crossref_primary_10_3174_ajnr_A6258 crossref_primary_10_3390_diagnostics11010118 crossref_primary_10_1007_s00261_017_1140_5 crossref_primary_10_1093_rpd_ncab020 crossref_primary_10_1055_s_0041_1730095 crossref_primary_10_1007_s00330_017_4825_9 crossref_primary_10_1007_s10554_020_01807_7 crossref_primary_10_1002_mp_15382 crossref_primary_10_1007_s00261_018_1687_9 crossref_primary_10_1259_bjr_20190675 crossref_primary_10_1002_mp_13123 crossref_primary_10_1016_j_crad_2017_09_006 crossref_primary_10_3390_diagnostics11030410 crossref_primary_10_1002_acm2_12765 crossref_primary_10_1002_mp_13763 crossref_primary_10_5114_pjr_2022_121433 crossref_primary_10_1016_j_ejrad_2018_07_027 crossref_primary_10_1097_RCT_0000000000000947 crossref_primary_10_1118_1_4967478 crossref_primary_10_1371_journal_pone_0176227 crossref_primary_10_3390_diagnostics14010096 crossref_primary_10_1117_1_JMI_3_3_033501 crossref_primary_10_1016_j_ejrad_2016_11_002 crossref_primary_10_3348_jksr_2021_0104 crossref_primary_10_1016_j_radi_2023_05_005 crossref_primary_10_1007_s00330_019_06359_6 crossref_primary_10_1088_1361_6560_ad11a3 crossref_primary_10_1007_s00330_017_5113_4 crossref_primary_10_1148_radiol_2017161736 crossref_primary_10_3390_diagnostics11122376 crossref_primary_10_1007_s00256_019_03206_z crossref_primary_10_1016_j_clinimag_2020_01_017 crossref_primary_10_1007_s00330_016_4687_6 crossref_primary_10_1007_s40134_022_00399_5 crossref_primary_10_1016_j_ejrad_2019_02_037 crossref_primary_10_1097_HP_0000000000001022 crossref_primary_10_1088_1361_6498_ace729 crossref_primary_10_1118_1_4927722 crossref_primary_10_1148_radiol_2018180137 crossref_primary_10_1007_s00330_020_06808_7 crossref_primary_10_32628_IJSRST24114201 crossref_primary_10_1148_radiol_2015150892 crossref_primary_10_1016_j_acra_2018_01_014 crossref_primary_10_1016_j_ejro_2016_06_001 crossref_primary_10_1097_PRS_0000000000007017 crossref_primary_10_1016_j_acra_2025_03_001 crossref_primary_10_1002_mp_13937 crossref_primary_10_1016_j_acra_2020_03_040 crossref_primary_10_1016_j_crad_2018_04_015 crossref_primary_10_1093_rpd_ncab058 crossref_primary_10_12688_f1000research_150773_1 crossref_primary_10_1097_RTI_0000000000000806 crossref_primary_10_2214_AJR_21_26654 crossref_primary_10_17946_JRST_2024_47_3_175 crossref_primary_10_4103_jmp_jmp_155_23 crossref_primary_10_1016_j_acra_2020_03_044 crossref_primary_10_1097_RLI_0000000000000312 crossref_primary_10_1016_j_acra_2016_05_016 crossref_primary_10_1016_j_diii_2020_01_002 crossref_primary_10_1016_j_oooo_2020_11_018 crossref_primary_10_1016_j_ejro_2022_100418 crossref_primary_10_1007_s00234_020_02406_y crossref_primary_10_1002_acm2_12435 crossref_primary_10_1088_2057_1976_aa99ea crossref_primary_10_1007_s00330_017_5243_8 crossref_primary_10_1097_RLI_0000000000000668 crossref_primary_10_1016_j_zemedi_2016_04_002 crossref_primary_10_1016_j_jcmg_2016_09_030 crossref_primary_10_1118_1_4903899 crossref_primary_10_1016_j_ijcard_2018_06_112 crossref_primary_10_1007_s00330_016_4383_6 |
| Cites_doi | 10.2214/AJR.12.9382 10.1016/j.ejmp.2012.01.003 10.1097/RLI.0000000000000037 10.1088/0031-9155/52/14/003 10.1118/1.4791645 10.1109/42.222670 10.1364/JOSAA.16.000633 10.1118/1.2988161 10.1118/1.4752209 10.1016/0730-4862(84)90042-8 10.1118/1.3560428 10.1118/1.594559 10.1118/1.4901670 10.1118/1.594534 10.1118/1.1513158 10.1364/JOSAA.14.002420 10.1118/1.4725171 10.1118/1.2789499 10.1118/1.4893497 |
| ContentType | Journal Article |
| Copyright | RSNA, 2015 |
| Copyright_xml | – notice: RSNA, 2015 |
| DBID | AAYXX CITATION CGR CUY CVF ECM EIF NPM 7X8 |
| DOI | 10.1148/radiol.15142005 |
| DatabaseName | CrossRef Medline MEDLINE MEDLINE (Ovid) MEDLINE MEDLINE PubMed MEDLINE - Academic |
| DatabaseTitle | CrossRef MEDLINE Medline Complete MEDLINE with Full Text PubMed MEDLINE (Ovid) MEDLINE - Academic |
| DatabaseTitleList | MEDLINE - Academic MEDLINE |
| Database_xml | – sequence: 1 dbid: NPM name: PubMed url: https://proxy.k.utb.cz/login?url=http://www.ncbi.nlm.nih.gov/entrez/query.fcgi?db=PubMed sourceTypes: Index Database – sequence: 2 dbid: EIF name: MEDLINE url: https://proxy.k.utb.cz/login?url=https://www.webofscience.com/wos/medline/basic-search sourceTypes: Index Database |
| DeliveryMethod | fulltext_linktorsrc |
| Discipline | Medicine |
| EISSN | 1527-1315 |
| EndPage | 745 |
| ExternalDocumentID | 25751228 10_1148_radiol_15142005 |
| Genre | Journal Article |
| GroupedDBID | --- .55 .GJ 123 18M 1CY 1KJ 29P 2WC 34G 39C 4.4 53G 5RE 6NX 6PF 7FM AAEJM AAQQT AAWTL AAYXX ABDPE ABHFT ABOCM ACFQH ACGFO ACJAN ADBBV AENEX AENYM AFFNX AJJEV AJWWR ALMA_UNASSIGNED_HOLDINGS BAWUL CITATION CS3 DIK DU5 E3Z EBS EJD F5P F9R GX1 H13 J5H KO8 L7B LMP LSO MJL MV1 N4W OK1 P2P R.V RKKAF RXW SJN TAE TR2 TRS TWZ W8F WH7 WOQ X7M YQI YQJ ZGI ZVN ZXP ACRZS AFOSN CGR CUY CVF ECM EIF NPM ZKG 7X8 |
| ID | FETCH-LOGICAL-c297t-5baaa8198aa0045adb995ea9dc4f520792a865dc81547c93fe7d6fa8135119293 |
| ISSN | 0033-8419 1527-1315 |
| IngestDate | Wed Oct 01 14:52:43 EDT 2025 Thu Apr 03 07:09:11 EDT 2025 Wed Oct 01 04:01:29 EDT 2025 Thu Apr 24 22:48:38 EDT 2025 |
| IsPeerReviewed | true |
| IsScholarly | true |
| Issue | 3 |
| Language | English |
| License | RSNA, 2015 |
| LinkModel | OpenURL |
| MergedId | FETCHMERGED-LOGICAL-c297t-5baaa8198aa0045adb995ea9dc4f520792a865dc81547c93fe7d6fa8135119293 |
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23 |
| PMID | 25751228 |
| PQID | 1682892025 |
| PQPubID | 23479 |
| PageCount | 11 |
| ParticipantIDs | proquest_miscellaneous_1682892025 pubmed_primary_25751228 crossref_primary_10_1148_radiol_15142005 crossref_citationtrail_10_1148_radiol_15142005 |
| ProviderPackageCode | CITATION AAYXX |
| PublicationCentury | 2000 |
| PublicationDate | 2015-06-00 2015-Jun 20150601 |
| PublicationDateYYYYMMDD | 2015-06-01 |
| PublicationDate_xml | – month: 06 year: 2015 text: 2015-06-00 |
| PublicationDecade | 2010 |
| PublicationPlace | United States |
| PublicationPlace_xml | – name: United States |
| PublicationTitle | Radiology |
| PublicationTitleAlternate | Radiology |
| PublicationYear | 2015 |
| References | r2 r3 r4 r5 r6 r7 r8 r9 r10 r20 r12 r11 r14 r13 r16 r15 r18 r17 r19 r1 |
| References_xml | – ident: r5 doi: 10.2214/AJR.12.9382 – ident: r1 doi: 10.1016/j.ejmp.2012.01.003 – ident: r2 doi: 10.1097/RLI.0000000000000037 – ident: r14 doi: 10.1088/0031-9155/52/14/003 – ident: r8 doi: 10.1118/1.4791645 – ident: r7 doi: 10.1109/42.222670 – ident: r9 doi: 10.1364/JOSAA.16.000633 – ident: r17 doi: 10.1118/1.2988161 – ident: r12 doi: 10.1118/1.4752209 – ident: r3 doi: 10.1016/0730-4862(84)90042-8 – ident: r4 – ident: r15 doi: 10.1118/1.3560428 – ident: r13 doi: 10.1118/1.594559 – ident: r19 doi: 10.1118/1.4901670 – ident: r16 doi: 10.1118/1.594534 – ident: r11 doi: 10.1118/1.1513158 – ident: r10 doi: 10.1364/JOSAA.14.002420 – ident: r18 doi: 10.1118/1.4725171 – ident: r6 doi: 10.1118/1.2789499 – ident: r20 doi: 10.1118/1.4893497 |
| SSID | ssj0014587 |
| Score | 2.5377204 |
| Snippet | To assess the effect of radiation dose reduction on low-contrast detectability by using an advanced modeled iterative reconstruction (ADMIRE; Siemens... |
| SourceID | proquest pubmed crossref |
| SourceType | Aggregation Database Index Database Enrichment Source |
| StartPage | 735 |
| SubjectTerms | Algorithms Contrast Media Equipment Design Image Processing, Computer-Assisted Models, Theoretical Multidetector Computed Tomography - instrumentation Phantoms, Imaging Radiation Dosage |
| Title | Diagnostic Performance of an Advanced Modeled Iterative Reconstruction Algorithm for Low-Contrast Detectability with a Third-Generation Dual-Source Multidetector CT Scanner: Potential for Radiation Dose Reduction in a Multireader Study |
| URI | https://www.ncbi.nlm.nih.gov/pubmed/25751228 https://www.proquest.com/docview/1682892025 |
| Volume | 275 |
| hasFullText | 1 |
| inHoldings | 1 |
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVBFR databaseName: Free Medical Journals customDbUrl: eissn: 1527-1315 dateEnd: 20241102 omitProxy: true ssIdentifier: ssj0014587 issn: 0033-8419 databaseCode: DIK dateStart: 20090101 isFulltext: true titleUrlDefault: http://www.freemedicaljournals.com providerName: Flying Publisher |
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwnV3db9MwELe2ISFeEN8rDHRIPCBVLouTNAlvVTcYH0VT20l7q5zYYZPaBHWpEPuX-Se4s500HZs0eInaqD63uV_tO9_d7xh740UqVLHc52h9pDxIw5RLpSMu0yRPtRJ-pshRHH3rH50En0_D063tvVbW0qpKe9nltXUl_6NVvId6pSrZf9BsIxRv4GvUL15Rw3i9lY4PbJ4cca4etwoAKLRfdAd1dH9kmt0oOpV3NN_kc66ZY7uD-fdyeV6dLUzO4dfyJyfOqqW8qHA5oiCD5fL-5QrhqNfnUnFLWG0EHKzknE9MGKBrKnqVGYbChlNcPaRp7-UPusdlRclJtmayOyZaBDuekubHRCJbp15KK2dpEq1NsuNG-JmGbsQDJvhuUbo6k4uaTtzWOurKlvJQ3fq8wfFYLlD8Jf94TodyNv60wsc2lMt52TgaE7nQJt_h8KzOXnJHJF64TuWql33f53Hg1mbtVnoRcc-3taT1ViBsFxeHeb-1sEeWVMXZCJGlwPx7-wmopGJpnkEPbamAzuzWO22dXXBlA27SIm2ReDyzAma1gG12R-CeRY1JDj59aWJkQRhbRlj34xxxFQp4d-UbbNpcNzhSxqCaPmD3nScEAwvrh2xLF4_Y3ZHL9XjMfq_RDS10Q5mDLKBGNzh0Q4Nu2EQ3NOgGFAFtdMMGuoHQDRKuohta6IYNdMNwCg7d76HBtpmmwTYQtqHBNpwXOEUL22Cw_YSdfDicDo-4a03CM5FEFQ9TKSUa07GU5BRJlSZJqGWisiAPxX6UCBn3Q5XF6KFEWeLnOlL9HEeYuD2a2E_ZTlEWepdBlHt9nNDzcuUHaZYmGbkYvohFlmqdRB3Wq5U3yxxvP7WPQXxcD5cOe9sM-GEpa27-6OsaDTPcVihWKAtdri5mXp-OYgR6RB32zMKkESYoVitE_Pz2E71g99Z_zD22gxjQL9Gar9JXBtR_AI9XAkY |
| linkProvider | Flying Publisher |
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Diagnostic+Performance+of+an+Advanced+Modeled+Iterative+Reconstruction+Algorithm+for+Low-Contrast+Detectability+with+a+Third-Generation+Dual-Source+Multidetector+CT+Scanner%3A+Potential+for+Radiation+Dose+Reduction+in+a+Multireader+Study&rft.jtitle=Radiology&rft.au=Solomon%2C+Justin&rft.au=Mileto%2C+Achille&rft.au=Ramirez-Giraldo%2C+Juan+Carlos&rft.au=Samei%2C+Ehsan&rft.date=2015-06-01&rft.issn=0033-8419&rft.eissn=1527-1315&rft.volume=275&rft.issue=3&rft.spage=735&rft.epage=745&rft_id=info:doi/10.1148%2Fradiol.15142005&rft.externalDBID=n%2Fa&rft.externalDocID=10_1148_radiol_15142005 |
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0033-8419&client=summon |
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0033-8419&client=summon |
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0033-8419&client=summon |