Augmented ε-Constraint Algorithm Applied to Multi-objective Optimization Programs of Residential Micro-CHP Systems

Micro-combined heat and power systems (Micro-CHP) are expected to play a major role in reducing carbon dioxide emission, increasing the primary energy and economic saving in the future. In this paper, the optimal planning of a residential Micro-CHP system for a single-family house situated in Iran i...

Full description

Saved in:
Bibliographic Details
Published inProcess integration and optimization for sustainability Vol. 6; no. 4; pp. 1143 - 1161
Main Authors Teymoori H., Fatemeh, Safari, Amir, Kamalinasab, Mostafa
Format Journal Article
LanguageEnglish
Published Singapore Springer Nature Singapore 01.12.2022
Springer Nature B.V
Subjects
Online AccessGet full text
ISSN2509-4238
2509-4246
2509-4246
DOI10.1007/s41660-022-00254-2

Cover

More Information
Summary:Micro-combined heat and power systems (Micro-CHP) are expected to play a major role in reducing carbon dioxide emission, increasing the primary energy and economic saving in the future. In this paper, the optimal planning of a residential Micro-CHP system for a single-family house situated in Iran is investigated. In order to achieve this target, a new mixed-integer linear programming model is developed. Mathematical modeling and optimization were carried out for the Micro-CHP system using natural gas, at the residential building level and for three different operating strategies, cost-driven, primary energy driven, and carbon emission driven. Three competing objective functions are simultaneously minimized using an augmented ε-constraint optimization algorithm. This work has multiple novelties, containing the consideration of some economic and technical constraints previously neglected, such as the energy, economic, and environmental effects of replacing conventional energy systems with a residential Micro-CHP system and the effects of integrating an electrical heating element for storing thermal energy (electrical heating element can act as a power sink when required). A detailed case study on a residential building situated in Tabriz city, Iran, was carried out by applying the developed model and the optimum strategies and optimal sizes for Micro-CHP, axillary boiler, and other equipment are obtained. Results have shown that the optimal values of CSR, PESR, and ERR, in the augmented ε-constraint method, were 12.46%, 1.19%, and 88.38%, respectively. In this case, the obtained result for a nominal capacity of Micro-CHP and boiler was 3.6 kW and 1.05 kW, respectively. Finally, the payback period was obtained for 2 years. Furthermore, to understand the influence of key parameters on the planning of the Micro-CHP system, the sensitivity analysis has been performed on energy prices. Sensitivity analysis of electricity price indicated that, by increasing the electricity price, the overall annual cost-saving value clearly increases, while increasing gas prices significantly reduces the profitability index.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:2509-4238
2509-4246
2509-4246