Evaluating the effect of low-density inhomogeneities: A comparative study of lithium fluoride detectors, radiochromic films, and collapsed cone algorithm in 6 MV photon beams
In recent years, there has been significant advancement in the development of physical simulators for dose evaluation. Many dosimetric studies employ solid materials, equivalent to human tissues, to evaluate dose distribution. This study aims to evaluate the effectiveness of inhomogeneity correction...
        Saved in:
      
    
          | Published in | Applied radiation and isotopes Vol. 202; p. 111032 | 
|---|---|
| Main Authors | , , , , , , , | 
| Format | Journal Article | 
| Language | English | 
| Published | 
            Elsevier Ltd
    
        01.12.2023
     | 
| Subjects | |
| Online Access | Get full text | 
| ISSN | 0969-8043 1872-9800 1872-9800  | 
| DOI | 10.1016/j.apradiso.2023.111032 | 
Cover
| Abstract | In recent years, there has been significant advancement in the development of physical simulators for dose evaluation. Many dosimetric studies employ solid materials, equivalent to human tissues, to evaluate dose distribution. This study aims to evaluate the effectiveness of inhomogeneity correction carried out by the Monaco/Elekta radiotherapy planning software. To achieve this goal, a physical simulator was created using cork boards to simulate lung tissue and solid water to represent other tissues. This simulator was combined with a dosimetric system that utilized lithium fluoride thermoluminescent detectors - RADOS MTS-N (LiF:Mg,Ti). The thermoluminescent detectors were positioned at various depths using a precisely drilled 2.0 mm thick acrylic plate, and they were placed at predefined positions. The irradiation of the simulator was conducted using an Elekta Synergy® Platform accelerator, employing a 6 MV photon beam with a field size of 15 × 15 cm2 and a source-surface distance (SSD) of 97.5 cm. A radiation dose of 200 cGy was applied for this study. In addition to the dosimetric assessment using thermoluminescent detectors, GAFCHROMIC™ EBT-3 Dosimetry Films were utilized to evaluate the dose at the same measurement points. The dose distribution data measured with the detectors were compared with the values provided by the planning system (TPS) and the inhomogeneity correction was verified. The results support the hypothesis that there is a lack of precision in the analytical simulations performed by the TPS, particularly in cases involving dose distribution at interfaces with varying densities.
•Built of a physical phantom using the combination of cork and solid water.•Study of radiological and physical properties of cork and solid water.•Dosimetry in a 6 MV photon beam with TLD MTS and radiochromic films.•Study of inhomogeneity correction of radiotherapy planning software. | 
    
|---|---|
| AbstractList | In recent years, there has been significant advancement in the development of physical simulators for dose evaluation. Many dosimetric studies employ solid materials, equivalent to human tissues, to evaluate dose distribution. This study aims to evaluate the effectiveness of inhomogeneity correction carried out by the Monaco/Elekta radiotherapy planning software. To achieve this goal, a physical simulator was created using cork boards to simulate lung tissue and solid water to represent other tissues. This simulator was combined with a dosimetric system that utilized lithium fluoride thermoluminescent detectors - RADOS MTS-N (LiF:Mg,Ti). The thermoluminescent detectors were positioned at various depths using a precisely drilled 2.0 mm thick acrylic plate, and they were placed at predefined positions. The irradiation of the simulator was conducted using an Elekta Synergy® Platform accelerator, employing a 6 MV photon beam with a field size of 15 × 15 cm2 and a source-surface distance (SSD) of 97.5 cm. A radiation dose of 200 cGy was applied for this study. In addition to the dosimetric assessment using thermoluminescent detectors, GAFCHROMIC™ EBT-3 Dosimetry Films were utilized to evaluate the dose at the same measurement points. The dose distribution data measured with the detectors were compared with the values provided by the planning system (TPS) and the inhomogeneity correction was verified. The results support the hypothesis that there is a lack of precision in the analytical simulations performed by the TPS, particularly in cases involving dose distribution at interfaces with varying densities.In recent years, there has been significant advancement in the development of physical simulators for dose evaluation. Many dosimetric studies employ solid materials, equivalent to human tissues, to evaluate dose distribution. This study aims to evaluate the effectiveness of inhomogeneity correction carried out by the Monaco/Elekta radiotherapy planning software. To achieve this goal, a physical simulator was created using cork boards to simulate lung tissue and solid water to represent other tissues. This simulator was combined with a dosimetric system that utilized lithium fluoride thermoluminescent detectors - RADOS MTS-N (LiF:Mg,Ti). The thermoluminescent detectors were positioned at various depths using a precisely drilled 2.0 mm thick acrylic plate, and they were placed at predefined positions. The irradiation of the simulator was conducted using an Elekta Synergy® Platform accelerator, employing a 6 MV photon beam with a field size of 15 × 15 cm2 and a source-surface distance (SSD) of 97.5 cm. A radiation dose of 200 cGy was applied for this study. In addition to the dosimetric assessment using thermoluminescent detectors, GAFCHROMIC™ EBT-3 Dosimetry Films were utilized to evaluate the dose at the same measurement points. The dose distribution data measured with the detectors were compared with the values provided by the planning system (TPS) and the inhomogeneity correction was verified. The results support the hypothesis that there is a lack of precision in the analytical simulations performed by the TPS, particularly in cases involving dose distribution at interfaces with varying densities. In recent years, there has been significant advancement in the development of physical simulators for dose evaluation. Many dosimetric studies employ solid materials, equivalent to human tissues, to evaluate dose distribution. This study aims to evaluate the effectiveness of inhomogeneity correction carried out by the Monaco/Elekta radiotherapy planning software. To achieve this goal, a physical simulator was created using cork boards to simulate lung tissue and solid water to represent other tissues. This simulator was combined with a dosimetric system that utilized lithium fluoride thermoluminescent detectors - RADOS MTS-N (LiF:Mg,Ti). The thermoluminescent detectors were positioned at various depths using a precisely drilled 2.0 mm thick acrylic plate, and they were placed at predefined positions. The irradiation of the simulator was conducted using an Elekta Synergy® Platform accelerator, employing a 6 MV photon beam with a field size of 15 × 15 cm2 and a source-surface distance (SSD) of 97.5 cm. A radiation dose of 200 cGy was applied for this study. In addition to the dosimetric assessment using thermoluminescent detectors, GAFCHROMIC™ EBT-3 Dosimetry Films were utilized to evaluate the dose at the same measurement points. The dose distribution data measured with the detectors were compared with the values provided by the planning system (TPS) and the inhomogeneity correction was verified. The results support the hypothesis that there is a lack of precision in the analytical simulations performed by the TPS, particularly in cases involving dose distribution at interfaces with varying densities. •Built of a physical phantom using the combination of cork and solid water.•Study of radiological and physical properties of cork and solid water.•Dosimetry in a 6 MV photon beam with TLD MTS and radiochromic films.•Study of inhomogeneity correction of radiotherapy planning software.  | 
    
| ArticleNumber | 111032 | 
    
| Author | Souza Castro, André Lima de Tavares e Silva, André Luiz Nolasco, Arnie Verde Rodrigues Gonçalves, Bruno Silveira, Anna Luiza Fraga da Calheiro, Daniel Silva Araújo, Fernanda da Silva Gonçalves Meira-Belo, Luiz Claudio  | 
    
| Author_xml | – sequence: 1 givenname: Anna Luiza Fraga da surname: Silveira fullname: Silveira, Anna Luiza Fraga da email: annaluiza_fraga@hotmail.com organization: Centro de Desenvolvimento da Tecnologia Nuclear, Belo Horizonte, MG, Brazil – sequence: 2 givenname: Fernanda da Silva Gonçalves surname: Araújo fullname: Araújo, Fernanda da Silva Gonçalves organization: Centro de Desenvolvimento da Tecnologia Nuclear, Belo Horizonte, MG, Brazil – sequence: 3 givenname: Daniel Silva surname: Calheiro fullname: Calheiro, Daniel Silva organization: Centro de Desenvolvimento da Tecnologia Nuclear, Belo Horizonte, MG, Brazil – sequence: 4 givenname: André Luiz orcidid: 0000-0002-8261-4115 surname: Tavares e Silva fullname: Tavares e Silva, André Luiz organization: Centro de Desenvolvimento da Tecnologia Nuclear, Belo Horizonte, MG, Brazil – sequence: 5 givenname: Bruno surname: Rodrigues Gonçalves fullname: Rodrigues Gonçalves, Bruno organization: Instituto de Radioterapia São Francisco, Belo Horizonte, MG, Brazil – sequence: 6 givenname: André Lima de surname: Souza Castro fullname: Souza Castro, André Lima de organization: Radiocare - Centro Especializado em Radioterapia, Belo Horizonte, MG, Brazil – sequence: 7 givenname: Arnie Verde surname: Nolasco fullname: Nolasco, Arnie Verde organization: Instituto de Radioterapia São Francisco, Belo Horizonte, MG, Brazil – sequence: 8 givenname: Luiz Claudio orcidid: 0000-0002-9531-9561 surname: Meira-Belo fullname: Meira-Belo, Luiz Claudio organization: Centro de Desenvolvimento da Tecnologia Nuclear, Belo Horizonte, MG, Brazil  | 
    
| BookMark | eNqFkU1uFDEQhS0UJCYJV0BesqAH2_1nsyKKkoAUxAbYWm67PO1Rt93Y7kFzG27AHXIyPAysWblk1feq6r1LdOGDB4ReUbKlhHZv91u1RGVcCltGWL2llJKaPUMbyntWCU7IBdoQ0YmKk6Z-gS5T2hNCGi7YBv26O6hpVdn5Hc4jYLAWdMbB4in8qAz45PIROz-GOezAg8sO0jt8g3WYFxULeACc8mqOfxiXR7fO2E5riM4ANpCLXIjpDT6tGPQYw-w0tm6ay5_ypghNk1oSnCoPWE27guZxLkNx9_Tz0ze8jCEHjwdQc7pGz62aErz8-16hr_d3X24_VI-fHz7e3jxWmgmWq4G3xhAOg6KtGpjtGFjNuRF8YHXftK2xVnAA0rT9MDBm9aBZS4ko5vVCqfoKvT7rLjF8XyFlObukoazqIaxJMt43rC8utqW1O7fqGFKKYOUS3aziUVIiTwnJvfyXkDwlJM8JFfD9GYRyyMFBlEk78BqMi8U1aYL7n8RvIKOkVg | 
    
| Cites_doi | 10.1016/S0927-796X(03)00034-2 10.1016/0360-3016(84)90454-1 10.14319/ijcto.0201.10 10.1016/j.meddos.2009.01.002 10.1016/j.radonc.2007.11.033 10.1017/S1460396914000508 10.29384/rbfm.2017.v11.n1.p28-34 10.1200/JGO.2015.001545 10.1118/1.3147204 10.1016/j.radphyschem.2019.108638 10.1016/S0360-3016(03)00337-7 10.4103/rpe.rpe_52_20  | 
    
| ContentType | Journal Article | 
    
| Copyright | 2023 Copyright © 2023. Published by Elsevier Ltd.  | 
    
| Copyright_xml | – notice: 2023 – notice: Copyright © 2023. Published by Elsevier Ltd.  | 
    
| DBID | AAYXX CITATION 7X8  | 
    
| DOI | 10.1016/j.apradiso.2023.111032 | 
    
| DatabaseName | CrossRef MEDLINE - Academic  | 
    
| DatabaseTitle | CrossRef MEDLINE - Academic  | 
    
| DatabaseTitleList | MEDLINE - Academic | 
    
| DeliveryMethod | fulltext_linktorsrc | 
    
| Discipline | Medicine Physics  | 
    
| EISSN | 1872-9800 | 
    
| ExternalDocumentID | 10_1016_j_apradiso_2023_111032 S0969804323003858  | 
    
| GroupedDBID | --- --K --M .55 .GJ .HR .~1 0R~ 1B1 1RT 1~. 1~5 23M 4.4 457 4G. 53G 5GY 5RE 5VS 7-5 71M 8P~ 9JN AACTN AAEDT AAEDW AAIAV AAIKJ AAKOC AALRI AAOAW AAQFI AAQXK AAXUO ABFNM ABJNI ABMAC ABNEU ABXDB ABYKQ ACDAQ ACFVG ACGFS ACNNM ACRLP ADBBV ADEZE ADMUD AEBSH AEKER AENEX AFKWA AFTJW AGHFR AGUBO AGYEJ AHHHB AHPSJ AIEXJ AIKHN AITUG AIVDX AJBFU AJOXV ALMA_UNASSIGNED_HOLDINGS AMFUW AMRAJ ASPBG AVWKF AXJTR AZFZN BBWZM BKOJK BLXMC CS3 EBS EFJIC EFLBG EJD EO8 EO9 EP2 EP3 F5P FDB FEDTE FGOYB FIRID FNPLU FYGXN G-Q GBLVA HMV HVGLF HZ~ IHE J1W KOM M38 M41 MO0 N9A NDZJH O-L O9- OAUVE OGIMB OZT P-8 P-9 P2P PC. Q38 R2- RIG RNS ROL RPZ SDF SDG SDP SES SEW SPC SPCBC SPD SPG SSQ SSZ T5K WH7 WUQ X7M XPP XUV ZA5 ZMT ~02 ~G- AATTM AAXKI AAYWO AAYXX ABWVN ACLOT ACRPL ACVFH ADCNI ADNMO AEIPS AEUPX AFJKZ AFPUW AGQPQ AIGII AIIUN AKBMS AKRWK AKYEP ANKPU APXCP CITATION EFKBS ~HD 7X8  | 
    
| ID | FETCH-LOGICAL-c292t-b85dd08eba15ab2f62efc88d98b237455dff98ee0457bb22fcbc2510911179aa3 | 
    
| IEDL.DBID | .~1 | 
    
| ISSN | 0969-8043 1872-9800  | 
    
| IngestDate | Thu Oct 02 06:35:42 EDT 2025 Sat Oct 25 05:24:56 EDT 2025 Fri Feb 23 02:35:05 EST 2024  | 
    
| IsPeerReviewed | true | 
    
| IsScholarly | true | 
    
| Keywords | Radiotherapy Inhomogeneities Dosimetry  | 
    
| Language | English | 
    
| LinkModel | DirectLink | 
    
| MergedId | FETCHMERGED-LOGICAL-c292t-b85dd08eba15ab2f62efc88d98b237455dff98ee0457bb22fcbc2510911179aa3 | 
    
| Notes | ObjectType-Article-1 SourceType-Scholarly Journals-1 ObjectType-Feature-2 content type line 23  | 
    
| ORCID | 0000-0002-9531-9561 0000-0002-8261-4115  | 
    
| PQID | 2874270045 | 
    
| PQPubID | 23479 | 
    
| ParticipantIDs | proquest_miscellaneous_2874270045 crossref_primary_10_1016_j_apradiso_2023_111032 elsevier_sciencedirect_doi_10_1016_j_apradiso_2023_111032  | 
    
| PublicationCentury | 2000 | 
    
| PublicationDate | December 2023 2023-12-00 20231201  | 
    
| PublicationDateYYYYMMDD | 2023-12-01 | 
    
| PublicationDate_xml | – month: 12 year: 2023 text: December 2023  | 
    
| PublicationDecade | 2020 | 
    
| PublicationTitle | Applied radiation and isotopes | 
    
| PublicationYear | 2023 | 
    
| Publisher | Elsevier Ltd | 
    
| Publisher_xml | – name: Elsevier Ltd | 
    
| References | (bib24) 2008 Tai (bib23) 2017; 4 Butson (bib3) 2003; 41 Kishore (bib14) 2020; 170 Wambersie (bib25) 1984; 10 Saxena, Higgins (bib19) 2010; 35 Castro, Thompson, Campos (bib4) 2017; 11 Dubey (bib7) 2021; 44 Kavousi (bib12) 2019; 16 Kamalian, Lev, Gupta (bib11) 2016; vol. 135 (bib1) 2004; 85 Scott (bib20) 1992 Zaghian (bib26) 2021; 11 Sera (bib21) 2021 Chaikh, Giraud, Balosso (bib5) 2014; 2 Khan, Gibbons (bib13) 2014 PAPANIKOLAOU, Nikos (bib16) 2004; 10 Yap (bib27) 2016; 2 Gray, Oliver, Johnston (bib8) 2009; 36 Rana, Pokharel (bib18) 2013; 1 Frank (bib28) 2003; 56 Morgan (bib15) 2008; 86 Sinousy (bib22) 2019; 16 Puchades (bib17) 2015; 14 Chaikh (10.1016/j.apradiso.2023.111032_bib5) 2014; 2 Wambersie (10.1016/j.apradiso.2023.111032_bib25) 1984; 10 Khan (10.1016/j.apradiso.2023.111032_bib13) 2014 Tai (10.1016/j.apradiso.2023.111032_bib23) 2017; 4 (10.1016/j.apradiso.2023.111032_bib24) 2008 Frank (10.1016/j.apradiso.2023.111032_bib28) 2003; 56 PAPANIKOLAOU (10.1016/j.apradiso.2023.111032_bib16) 2004; 10 Castro (10.1016/j.apradiso.2023.111032_bib4) 2017; 11 Saxena (10.1016/j.apradiso.2023.111032_bib19) 2010; 35 Kamalian (10.1016/j.apradiso.2023.111032_bib11) 2016; vol. 135 Zaghian (10.1016/j.apradiso.2023.111032_bib26) 2021; 11 Kavousi (10.1016/j.apradiso.2023.111032_bib12) 2019; 16 Butson (10.1016/j.apradiso.2023.111032_bib3) 2003; 41 Sera (10.1016/j.apradiso.2023.111032_bib21) 2021 Sinousy (10.1016/j.apradiso.2023.111032_bib22) 2019; 16 Yap (10.1016/j.apradiso.2023.111032_bib27) 2016; 2 Kishore (10.1016/j.apradiso.2023.111032_bib14) 2020; 170 Dubey (10.1016/j.apradiso.2023.111032_bib7) 2021; 44 Rana (10.1016/j.apradiso.2023.111032_bib18) 2013; 1 (10.1016/j.apradiso.2023.111032_bib1) 2004; 85 Morgan (10.1016/j.apradiso.2023.111032_bib15) 2008; 86 Puchades (10.1016/j.apradiso.2023.111032_bib17) 2015; 14 Scott (10.1016/j.apradiso.2023.111032_bib20) 1992 Gray (10.1016/j.apradiso.2023.111032_bib8) 2009; 36  | 
    
| References_xml | – volume: 86 start-page: 48 year: 2008 end-page: 54 ident: bib15 article-title: Clinical implications of the implementation of advanced treatment planning algorithms for thoracic treatments publication-title: Radiother. Oncol. – volume: 4 start-page: 124 year: 2017 end-page: 127 ident: bib23 article-title: Evaluating the impact of tissue heterogeneity corrections in a commercial treatment planning system (TPS), Prowess Panther publication-title: Int. J. Radiol. – volume: 85 start-page: 142 year: 2004 ident: bib1 article-title: Tissue inhomogeneity corrections for megavoltage photon beams publication-title: Radiation Therapy Committee Task Group – year: 1992 ident: bib20 publication-title: Photon, Electron, Proton and Neutron Interaction Data for Body Tissues: ICRU Report 46 – volume: 11 start-page: 143 year: 2021 ident: bib26 article-title: Investigation of collapsed-cone algorithm accuracy in small fields and heterogeneous environments publication-title: J. Biomed. Phys. & Eng. – year: 2021 ident: bib21 article-title: Computed Tomography – volume: 1 start-page: 63 year: 2013 ident: bib18 article-title: Verification of dose calculation algorithms in a multi-layer heterogeneous phantom using films publication-title: Gulf. J. Oncol. – volume: 10 start-page: 81 year: 1984 end-page: 86 ident: bib25 article-title: The role of the ICRU in quality assurance in radiation therapy publication-title: Int. J. Radiat. Oncol. Biol. Phys. – volume: 36 start-page: 3181 year: 2009 end-page: 3191 ident: bib8 article-title: The accuracy of the pencil beam convolution and anisotropic analytical algorithms in predicting the dose effects due to attenuation from immobilization devices and large air gaps publication-title: Med. Phys. – volume: 16 start-page: 285 year: 2019 end-page: 293 ident: bib12 article-title: Evaluation of dose calculation algorithms accuracy for eclipse, PCRT3D, and Monaco treatment planning systems using IAEA TPS commissioning tests in a Heterogeneous Phantom publication-title: Iranian J. Med. Phys. – volume: 10 start-page: 86 year: 2004 ident: bib16 article-title: Report of the AAPM Task Group No. 65: Tissue inhomogeneity corrections for megavoltage photon beams. publication-title: Medical Physics Publishing – volume: 2 start-page: 207 year: 2016 end-page: 215 ident: bib27 article-title: Global access to radiotherapy services: have we made progress during the past decade? publication-title: J. Global Oncol. – volume: 56 start-page: 1308 year: 2003 end-page: 1318 ident: bib28 article-title: Treatment planning for lung cancer: Traditional homogeneous point–dose prescription compared with heterogeneity-corrected dose–volume prescription publication-title: Int. J. Radiat. Oncol. Biol. Phys. – year: 2014 ident: bib13 article-title: Khan's the Physics of Radiation Therapy – volume: 44 start-page: 110 year: 2021 ident: bib7 article-title: Dosimetric evaluation of analytic anisotropic algorithm and Acuros XB algorithm using in-house developed heterogeneous thorax phantom and homogeneous slab phantom for stereotactic body radiation therapy technique publication-title: Radiat. Protect. Environ. – volume: 16 start-page: 180 year: 2019 ident: bib22 article-title: Dosimetric study of tissue heterogeneity correction for breast conformal radiotherapy publication-title: Iran J. Med. Phys. – volume: vol. 135 year: 2016 ident: bib11 publication-title: Computed Tomography Imaging and Angiography–Principles – volume: 170 year: 2020 ident: bib14 article-title: A study for the development of a low density heterogeneous phantom for dose verification in high energy photon beam publication-title: Radiat. Phys. Chem. – volume: 11 start-page: 28 year: 2017 end-page: 34 ident: bib4 article-title: Avaliação dosimétrica experimental de efeitos de inomogeneidade causados por vértebras torácicas publication-title: Revista Brasileira de Física Médica – volume: 2 year: 2014 ident: bib5 article-title: A method to quantify and assess the dosimetric and clinical impact resulting from the heterogeneity correction in radiotherapy for lung cancer publication-title: Int. J. Cancer Ther. Oncol. – volume: 14 start-page: 162 year: 2015 end-page: 170 ident: bib17 article-title: Dosimetric study of the AAA algorithm for the VMAT technique using an anthropomorphic phantom in the pelvic region publication-title: J. Radiother. Pract. – year: 2008 ident: bib24 article-title: Guide to the Risø TL/OSL Reader – volume: 41 start-page: 61 year: 2003 end-page: 120 ident: bib3 article-title: Radiochromic film for medical radiation dosimetry publication-title: Mater. Sci. Eng. – volume: 35 start-page: 19 year: 2010 end-page: 27 ident: bib19 article-title: Measurement and evaluation of inhomogeneity corrections and monitor unit verification for treatment planning publication-title: Med. Dosim. – volume: 85 start-page: 142 year: 2004 ident: 10.1016/j.apradiso.2023.111032_bib1 article-title: Tissue inhomogeneity corrections for megavoltage photon beams publication-title: Radiation Therapy Committee Task Group – volume: 41 start-page: 61 year: 2003 ident: 10.1016/j.apradiso.2023.111032_bib3 article-title: Radiochromic film for medical radiation dosimetry publication-title: Mater. Sci. Eng. doi: 10.1016/S0927-796X(03)00034-2 – volume: 11 start-page: 143 issue: 2 year: 2021 ident: 10.1016/j.apradiso.2023.111032_bib26 article-title: Investigation of collapsed-cone algorithm accuracy in small fields and heterogeneous environments publication-title: J. Biomed. Phys. & Eng. – volume: 1 start-page: 63 issue: 14 year: 2013 ident: 10.1016/j.apradiso.2023.111032_bib18 article-title: Verification of dose calculation algorithms in a multi-layer heterogeneous phantom using films publication-title: Gulf. J. Oncol. – volume: 16 start-page: 285 issue: 4 year: 2019 ident: 10.1016/j.apradiso.2023.111032_bib12 article-title: Evaluation of dose calculation algorithms accuracy for eclipse, PCRT3D, and Monaco treatment planning systems using IAEA TPS commissioning tests in a Heterogeneous Phantom publication-title: Iranian J. Med. Phys. – year: 1992 ident: 10.1016/j.apradiso.2023.111032_bib20 – volume: 10 start-page: 81 year: 1984 ident: 10.1016/j.apradiso.2023.111032_bib25 article-title: The role of the ICRU in quality assurance in radiation therapy publication-title: Int. J. Radiat. Oncol. Biol. Phys. doi: 10.1016/0360-3016(84)90454-1 – volume: 10 start-page: 86 year: 2004 ident: 10.1016/j.apradiso.2023.111032_bib16 article-title: Report of the AAPM Task Group No. 65: Tissue inhomogeneity corrections for megavoltage photon beams. Madison WI publication-title: Medical Physics Publishing – volume: 2 issue: 1 year: 2014 ident: 10.1016/j.apradiso.2023.111032_bib5 article-title: A method to quantify and assess the dosimetric and clinical impact resulting from the heterogeneity correction in radiotherapy for lung cancer publication-title: Int. J. Cancer Ther. Oncol. doi: 10.14319/ijcto.0201.10 – volume: 16 start-page: 180 issue: 1 year: 2019 ident: 10.1016/j.apradiso.2023.111032_bib22 article-title: Dosimetric study of tissue heterogeneity correction for breast conformal radiotherapy publication-title: Iran J. Med. Phys. – volume: 35 start-page: 19 issue: 1 year: 2010 ident: 10.1016/j.apradiso.2023.111032_bib19 article-title: Measurement and evaluation of inhomogeneity corrections and monitor unit verification for treatment planning publication-title: Med. Dosim. doi: 10.1016/j.meddos.2009.01.002 – volume: 86 start-page: 48 issue: 1 year: 2008 ident: 10.1016/j.apradiso.2023.111032_bib15 article-title: Clinical implications of the implementation of advanced treatment planning algorithms for thoracic treatments publication-title: Radiother. Oncol. doi: 10.1016/j.radonc.2007.11.033 – volume: 14 start-page: 162 issue: 2 year: 2015 ident: 10.1016/j.apradiso.2023.111032_bib17 article-title: Dosimetric study of the AAA algorithm for the VMAT technique using an anthropomorphic phantom in the pelvic region publication-title: J. Radiother. Pract. doi: 10.1017/S1460396914000508 – volume: 11 start-page: 28 issue: 1 year: 2017 ident: 10.1016/j.apradiso.2023.111032_bib4 article-title: Avaliação dosimétrica experimental de efeitos de inomogeneidade causados por vértebras torácicas publication-title: Revista Brasileira de Física Médica doi: 10.29384/rbfm.2017.v11.n1.p28-34 – year: 2021 ident: 10.1016/j.apradiso.2023.111032_bib21 – volume: vol. 135 year: 2016 ident: 10.1016/j.apradiso.2023.111032_bib11 – year: 2014 ident: 10.1016/j.apradiso.2023.111032_bib13 – volume: 2 start-page: 207 issue: 4 year: 2016 ident: 10.1016/j.apradiso.2023.111032_bib27 article-title: Global access to radiotherapy services: have we made progress during the past decade? publication-title: J. Global Oncol. doi: 10.1200/JGO.2015.001545 – volume: 36 start-page: 3181 issue: 7 year: 2009 ident: 10.1016/j.apradiso.2023.111032_bib8 article-title: The accuracy of the pencil beam convolution and anisotropic analytical algorithms in predicting the dose effects due to attenuation from immobilization devices and large air gaps publication-title: Med. Phys. doi: 10.1118/1.3147204 – volume: 170 year: 2020 ident: 10.1016/j.apradiso.2023.111032_bib14 article-title: A study for the development of a low density heterogeneous phantom for dose verification in high energy photon beam publication-title: Radiat. Phys. Chem. doi: 10.1016/j.radphyschem.2019.108638 – volume: 56 start-page: 1308 issue: 5 year: 2003 ident: 10.1016/j.apradiso.2023.111032_bib28 article-title: Treatment planning for lung cancer: Traditional homogeneous point–dose prescription compared with heterogeneity-corrected dose–volume prescription publication-title: Int. J. Radiat. Oncol. Biol. Phys. doi: 10.1016/S0360-3016(03)00337-7 – volume: 44 start-page: 110 issue: 2 year: 2021 ident: 10.1016/j.apradiso.2023.111032_bib7 article-title: Dosimetric evaluation of analytic anisotropic algorithm and Acuros XB algorithm using in-house developed heterogeneous thorax phantom and homogeneous slab phantom for stereotactic body radiation therapy technique publication-title: Radiat. Protect. Environ. doi: 10.4103/rpe.rpe_52_20 – year: 2008 ident: 10.1016/j.apradiso.2023.111032_bib24 – volume: 4 start-page: 124 issue: 1 year: 2017 ident: 10.1016/j.apradiso.2023.111032_bib23 article-title: Evaluating the impact of tissue heterogeneity corrections in a commercial treatment planning system (TPS), Prowess Panther publication-title: Int. J. Radiol.  | 
    
| SSID | ssj0004892 | 
    
| Score | 2.3679473 | 
    
| Snippet | In recent years, there has been significant advancement in the development of physical simulators for dose evaluation. Many dosimetric studies employ solid... | 
    
| SourceID | proquest crossref elsevier  | 
    
| SourceType | Aggregation Database Index Database Publisher  | 
    
| StartPage | 111032 | 
    
| SubjectTerms | Dosimetry Inhomogeneities Radiotherapy  | 
    
| Title | Evaluating the effect of low-density inhomogeneities: A comparative study of lithium fluoride detectors, radiochromic films, and collapsed cone algorithm in 6 MV photon beams | 
    
| URI | https://dx.doi.org/10.1016/j.apradiso.2023.111032 https://www.proquest.com/docview/2874270045  | 
    
| Volume | 202 | 
    
| hasFullText | 1 | 
    
| inHoldings | 1 | 
    
| isFullTextHit | |
| isPrint | |
| journalDatabaseRights | – providerCode: PRVESC databaseName: Baden-Württemberg Complete Freedom Collection (Elsevier) customDbUrl: eissn: 1872-9800 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0004892 issn: 0969-8043 databaseCode: GBLVA dateStart: 20110101 isFulltext: true titleUrlDefault: https://www.sciencedirect.com providerName: Elsevier – providerCode: PRVESC databaseName: Elsevier SD Complete Freedom Collection [SCCMFC] customDbUrl: eissn: 1872-9800 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0004892 issn: 0969-8043 databaseCode: ACRLP dateStart: 19950101 isFulltext: true titleUrlDefault: https://www.sciencedirect.com providerName: Elsevier – providerCode: PRVESC databaseName: Science Direct customDbUrl: eissn: 1872-9800 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0004892 issn: 0969-8043 databaseCode: .~1 dateStart: 19950101 isFulltext: true titleUrlDefault: https://www.sciencedirect.com providerName: Elsevier – providerCode: PRVESC databaseName: ScienceDirect customDbUrl: eissn: 1872-9800 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0004892 issn: 0969-8043 databaseCode: AIKHN dateStart: 19950101 isFulltext: true titleUrlDefault: https://www.sciencedirect.com providerName: Elsevier – providerCode: PRVLSH databaseName: Elsevier Journals customDbUrl: mediaType: online eissn: 1872-9800 dateEnd: 99991231 omitProxy: true ssIdentifier: ssj0004892 issn: 0969-8043 databaseCode: AKRWK dateStart: 19930101 isFulltext: true providerName: Library Specific Holdings  | 
    
| link | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV3NbtQwELaqViAuqBQQpVANEkeym3XsrMNtVbVaQNsLFPUW2bHdpNr8aJNVxYVn4Q14hz5ZPU6iAhLiwCVKrDhOMpPP48w3M4S8ZTOtLdYAZHrmNlw5HHTr5kCGmotYGcYpBievzuPlBft4yS93yMkYC4O0ygH7e0z3aD20TIe3OW2KYvrZGd-JwIxyUe_ewgh2NscqBpPv9zQPJnxhZDw5wLN_iRK-nshmI5G1M8Ei4ogeYUT_NkH9AdV-_jnbJ48HwxEW_b09ITumOiAPV4Nr_IA88FzOrH1Kfp4OGbyrK3DmHfSUDagtrOubQCNjvfsGRZXXZe3Ux_icqu9hAdl9JnDwaWd9n6LLi20Jdr2tN4U2oE3n__S37wAfq87yDUY2gy3WpWuTlQavXE1rcK8yINdXrmuXl25QiG9_rL5Ck9fO6ARlZNk-Ixdnp19OlsFQlyHIaEK7QAmudSiMkjMuFbUxNTYTQidC0WjOONfWJsIYZy3OlaLUZipzZlSIuDpPpIyek93KDf-CQKRwDWTCTCvGeOjUOorjLLaJnIWKGXZIpqMw0qZPv5GOvLTrdBRfiuJLe_EdkmSUWfqbIqVujvhn3zejkFP3laHrRFam3rYpVgVAFz3jL__j-kfkER71bJhXZLfbbM1rZ9N06tgr7THZW3z4tDy_AwIK-wA | 
    
| linkProvider | Elsevier | 
    
| linkToHtml | http://utb.summon.serialssolutions.com/2.0.0/link/0/eLvHCXMwpV3NbtQwELZKEdALgkJF-R0kjmQ3m9hZh1tVtVqg2wst6s2yY7tJtfnRJivUC8_CG_AOPBkeJ1EBCXHgEkWOf5LMZGac-WaGkDd0prXFGoBUz9yBKScH3b45kKFmPFGGsgiDk5enyeKcfrhgF1vkcIyFQVjlIPt7me6l9dAyHd7mtCmK6SdnfKccM8rFvXvrFrntZp7jDmzy9QbnQbmvjIy9A-z-S5jw1UQ2a4mwnQlWEUfxEcbR3zTUH7LaK6DjB-T-YDnCQX9zD8mWqXbJ3eXgG98ldzyYM2sfke9HQwrv6hKcfQc9ZgNqC6v6S6ARst5dQ1HldVk7_jE-qeo7OIDsJhU4-LyzfkzR5cWmBLva1OtCG9Cm87_627eAj1Vn-RpDm8EWq9K1yUqD566mNXhWGZCrSze0y0u3KCQ_vi0_Q5PXzuoEZWTZPibnx0dnh4tgKMwQZFEadYHiTOuQGyVnTKrIJpGxGec65SqK55QxbW3KjXHm4lypKLKZypwdFaJgnadSxntku3LLPyEQK9wEmTDTilIWOr6OkyRLbCpnoaKG7pPpSAzR9Pk3xAhMuxIj-QSST_Tk2yfpSDPxGycJpyT-Ofb1SGThPjP0ncjK1JtWYFkA9NFT9vQ_5n9F7i3Olifi5P3px2dkB6_00JjnZLtbb8wLZ-B06qVn4J_GEPyV | 
    
| openUrl | ctx_ver=Z39.88-2004&ctx_enc=info%3Aofi%2Fenc%3AUTF-8&rfr_id=info%3Asid%2Fsummon.serialssolutions.com&rft_val_fmt=info%3Aofi%2Ffmt%3Akev%3Amtx%3Ajournal&rft.genre=article&rft.atitle=Evaluating+the+effect+of+low-density+inhomogeneities%3A+A+comparative+study+of+lithium+fluoride+detectors%2C+radiochromic+films%2C+and+collapsed+cone+algorithm+in+6+MV+photon+beams&rft.jtitle=Applied+radiation+and+isotopes&rft.au=Silveira%2C+Anna+Luiza+Fraga+da&rft.au=Ara%C3%BAjo%2C+Fernanda+da+Silva+Gon%C3%A7alves&rft.au=Calheiro%2C+Daniel+Silva&rft.au=Tavares+E+Silva%2C+Andr%C3%A9+Luiz&rft.date=2023-12-01&rft.issn=1872-9800&rft.eissn=1872-9800&rft.volume=202&rft.spage=111032&rft_id=info:doi/10.1016%2Fj.apradiso.2023.111032&rft.externalDBID=NO_FULL_TEXT | 
    
| thumbnail_l | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/lc.gif&issn=0969-8043&client=summon | 
    
| thumbnail_m | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/mc.gif&issn=0969-8043&client=summon | 
    
| thumbnail_s | http://covers-cdn.summon.serialssolutions.com/index.aspx?isbn=/sc.gif&issn=0969-8043&client=summon |