Sensitive AC Hysteresigraph of Extended Driving Field Capability

An induction hysteresigraph using 50 Hz sine wave fields of 7 kOe maximum amplitude, generated by a solenoid-type multilayer coil, suitable for small amounts (down to tens of milligram) of magnetic materials is proposed. The changes in field and magnetization are detected by a field sensing coil and...

Full description

Saved in:
Bibliographic Details
Published inIEEE transactions on instrumentation and measurement Vol. 69; no. 4; pp. 1643 - 1651
Main Author Ercuta, Aurel
Format Journal Article
LanguageEnglish
Published New York IEEE 01.04.2020
The Institute of Electrical and Electronics Engineers, Inc. (IEEE)
Subjects
Online AccessGet full text
ISSN0018-9456
1557-9662
DOI10.1109/TIM.2019.2917237

Cover

More Information
Summary:An induction hysteresigraph using 50 Hz sine wave fields of 7 kOe maximum amplitude, generated by a solenoid-type multilayer coil, suitable for small amounts (down to tens of milligram) of magnetic materials is proposed. The changes in field and magnetization are detected by a field sensing coil and a compensated pick-up coil system , respectively, the as-induced signals being processed by two analog measuring channels ( channel H and channel M ), whose output signals reproduce the time evolution H(t) and M(t) of the two quantities. These signals are recorded via PC-assisted analog-to-digital conversion and then subjected to final numerical correction and calibration; apart from the demagnetizing field correction, the possible errors caused by the stray flux generated by the magnetized sample itself are also taken into account. In addition, instead of weak signals denoising via standard filtering or smoothing algorithms, reconstruction based on flexible combinations of transition-type fitting functions of time periodic argument is proposed. To prevent signal waveform distortions that can be caused by the frequency-dependent response of channel M , a thorough analysis is carried out in the time domain, by simulating the run of a 100 kHz bandwidth severe test signal, across the stages of this channel. This signal consists of sharp ac pulses, built as a digital replica of the electromotive force induced in a pick-up coil containing the sample, during its evolution along a steep-sided hysteresis loop; an original method, using a small number of parameters, is proposed to build the spectral expansion of the test signal.
Bibliography:ObjectType-Article-1
SourceType-Scholarly Journals-1
ObjectType-Feature-2
content type line 14
ISSN:0018-9456
1557-9662
DOI:10.1109/TIM.2019.2917237