A novel inconsistency condition for 2-port vector network analyzer calibration
An inconsistency condition for 2‐port vector network analyzer (VNA) calibration is presented.This inconsistency condition discussed the use of Reciprocal device and Line or Thru for calibration of 2‐port VNA. Mathematical analysis is carried out. The experimental results are compared with well known...
Saved in:
| Published in | Microwave and optical technology letters Vol. 54; no. 10; pp. 2372 - 2375 |
|---|---|
| Main Author | |
| Format | Journal Article |
| Language | English |
| Published |
Hoboken
Wiley Subscription Services, Inc., A Wiley Company
01.10.2012
|
| Subjects | |
| Online Access | Get full text |
| ISSN | 0895-2477 1098-2760 |
| DOI | 10.1002/mop.27072 |
Cover
| Summary: | An inconsistency condition for 2‐port vector network analyzer (VNA) calibration is presented.This inconsistency condition discussed the use of Reciprocal device and Line or Thru for calibration of 2‐port VNA. Mathematical analysis is carried out. The experimental results are compared with well known calibration algorithms like Thru‐Short‐Delay, Thru‐Reflect‐Line, Short‐Open‐Load‐ Reciprocal, and Thru‐Short‐Match. © 2012 Wiley Periodicals, Inc. Microwave Opt Technol Lett 54:2372–2375, 2012; View this article online at wileyonlinelibrary.com. DOI 10.1002/mop.27072 |
|---|---|
| Bibliography: | ark:/67375/WNG-Z5Q6F171-H istex:4BC7A141F53CBDDE5B8A48A4AFE81C068D0770A9 ArticleID:MOP27072 |
| ISSN: | 0895-2477 1098-2760 |